NOTICE: Particulars are believed to be correct and subject to revision without prior notice. Interested parties must inspect vessel to check on suitability of the Compan y’s equipment. Company has exerciseddue diligence to ensure that the data contained herein is reasonably accurate. However, the Company does not warrant the accuracy or completeness of the data. In no event shall the Company be liable forany damages whatsoever arising out of the use or inability to use the data contained herein.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
LCT Krishnan700 HP Landing Craft TankerPrincipal Part iculars
Built / Rebuilt : 1996 / 2010Flag : IndonesiaClassification : BKI
Dimensions
Length Overall : 42.63 mBreadth : 9.50 mDraft (loaded) : 1.80 m
DWT : 500 TonsGRT/ NRT : 353 / 106 Tons
Propulsion
Main Engines : 2 x 350 HP CUMMINS MTA -855 MGenerators : 2 x 150 HP CUMMINS 4 BT-3.9 & Perkins M200 + 1 unit port generatorPropellers / Rudders : Twin Screw Fixed Pitch 360° / Open Propellers
Speed and Consumption
Maximum Speed : 9 KnotsConsumption : 4.0 Tons / DayEconomical Speed : 8 Knots
Consumption : 3.3 Tons / DayType of Fuel : Marine Gas Oil
Cargo Capacit ies
Max Deck Space : 185 m (24 m X 7.7 m) + 35 m
(7 m x 5 m)
Ramp Door : Opening 6.1 meters, 40 tons m2 loading capacity
Deck Strength : 2.5 tons/ m2
Cargo Railing : ProvidedFuel Oil : 300 m
3
Potable Water : 140 m3
Freezer Space : 10 m3
Cooler Space : 10 m3
Discharge Rates
Fuel Oil : 73 m3/ Hr @ 40 mPotable Water : 73 m3/ Hr @ 40 m
Equipment
Tugger Winch : 5 TonsGangway : ProvidedDynamo : 7.5 HP TantungPilot Ladder : ProvidedFresh Water Maker : 1.5 tons / dayCrane : 5 Tons
Accommodation
Officer : 2 x 1 BerthsCrew : 2 x 3 BerthsPassenger/Crew : 3 x 1 BerthsTotal : 11 Berths Note: Can Accommodate 5 Additional PAX Excluding Crew with Crew Rotations
-
8/17/2019 Specs LCT Krishnan.186223528
2/4
NOTICE: Particulars are believed to be correct and subject to revision without prior notice. Interested parties must inspect vessel to check on suitability of the Compan y’s equipment. Company has exerciseddue diligence to ensure that the data contained herein is reasonably accurate. However, the Company does not warrant the accuracy or completeness of the data. In no event shall the Company be liable forany damages whatsoever arising out of the use or inability to use the data contained herein.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Radio And Navigat ion Equipment
SSB : Furuno TRP 1562 HF / SSBVHF : ICOM M-45Echo Sounder : Data Marine 3000Radar : Koden MD-3605, Furuno 1721 Mark 2 / Furuno 1832 Model 1832Weather Fax : Navtex Receiver ICS Nav 5 c/w AntennaGPS : Samyung SPR 1400 GPS Navigator AIS : Frequency 156.025 Mhz-162.025 Mhz, Prov idedCompass : Saura MR-150 Auto Pi lo t : Samyung SAS7Computer + Printer : ProvidedSatellite Phone + Email : Provided
Fire Fighting Equipment
Fire Pump : Southern Cross 150 cu. Meters / hourFire Monitor : Caccialanza A3V – 2,000 liters / hour
Safety Equipment
Vessel built to comply with SOLAS Regulations
-
8/17/2019 Specs LCT Krishnan.186223528
3/4
NOTICE: Particulars are believed to be correct and subject to revision without prior notice. Interested parties must inspect vessel to check on suitability of the Compan y’s equipment. Company has exerciseddue diligence to ensure that the data contained herein is reasonably accurate. However, the Company does not warrant the accuracy or completeness of the data. In no event shall the Company be liable forany damages whatsoever arising out of the use or inability to use the data contained herein.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-
8/17/2019 Specs LCT Krishnan.186223528
4/4
NOTICE: Particulars are believed to be correct and subject to revision without prior notice. Interested parties must inspect vessel to check on suitability of the Compan y’s equipment. Company has exerciseddue diligence to ensure that the data contained herein is reasonably accurate. However, the Company does not warrant the accuracy or completeness of the data. In no event shall the Company be liable forany damages whatsoever arising out of the use or inability to use the data contained herein.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -