specifications for teck tm repair clamps ... - cambridge brass · the cambridge brass repair clamp...

2
SPECIFICATIONS FOR TECK TM REPAIR CLAMPS SERIES 425, 825 1625 - STANDARD SERIES 435, 835, 1635 - TAPPED OUTLET CAMBRIDGE BRASS INC. WATERWORKS BRASS MANUFACTURERS 140 Orion Place, Cambridge, Ontario, N1R 5V1, Canada www.cambridgebrass.com Phone: 519-621-5520 Canada Toll Free: 1-800-265-6638 U.S. Toll Free: 1-800-724-3906 Fax: 519-621-8038 © 2017Cambridge Brass Inc. FEBRURARY2017CAMB2017 24 hr emergency service

Upload: others

Post on 21-Aug-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SPECIFICATIONS FOR TECK TM REPAIR CLAMPS ... - Cambridge Brass · The Cambridge Brass repair clamp shall have a 20 gauge type 304 stainless steel band. The band shall be a minimum

S P E C I F I C A T I O N S F O R T E C K T M R E P A I R C L A M P SS E R I E S 4 2 5 , 8 2 5 1 6 2 5 - S T A N D A R DS E R I E S 4 3 5 , 8 3 5 , 1 6 3 5 - T A P P E D O U T L E T

C A M B R I D G E B R A S S I N C . WAT E RWO R K S B R A S S M A N U FAC T U R E R S140 Orion Place, Cambridge, Ontario, N1R 5V1, Canadawww.cambridgebrass.comPhone: 519-621-5520 Canada Toll Free: 1-800-265-6638U.S. Toll Free: 1-800-724-3906 Fax: 519-621-8038

© 2017Cambridge Brass Inc. FEBRURARY2017CAMB2017

24 hremergency

service

Page 2: SPECIFICATIONS FOR TECK TM REPAIR CLAMPS ... - Cambridge Brass · The Cambridge Brass repair clamp shall have a 20 gauge type 304 stainless steel band. The band shall be a minimum

FEATURES:• SS304 used for all metal parts to prevent corrosion• TECK™ fingers ease installation without removing nuts• NSF certified, NBR standard with flat gasket and finger joint. Also available with grid gasket with taper joint.• Made to standard pipe sizes, custom sizes available upon request• Available widths 8”, 12”, 16”, 20”, 24” and 32”• 20 gauge Type 304 stainless steel band for corrosion resistance• Economical means of repairing pin hole leaks, punctures and splits in pipe • Available with side outlet 3/4” to 2”, AWWA and FIP

SPECIFICATIONS:The gasket shall be nitrile to resist water, chemicals and con-taminants.

The repair clamp shall have all metal parts made of 304 SS. Stainless steel bot be fully passivated. TECK™ fingers and studs shall be welded to the bracket. Brackets shall be welded directly to the band. Nuts shall have captive (attached) swivel washers which pass through the TECK™ bracket while on the stud for simple installation, without lifter bar. Nuts shall be fluoropolymer coated to prevent galling.

The Cambridge Brass repair clamp shall have a 20 gauge type 304 stainless steel band. The band shall be a minimum of 8” in width.

Recommended bolt torque - 60 ft./lbs.NBR gasket certified to Standard NSF 61.

Ph: (800)-265-6638 (CDN) * (800) 724-3906 (US) * www.cambridgebrass.com

P R O D U C T S P E C I F I C A T I O N S F O R T E C K T M R E PA I R C L A M P S

S E R I E S 4 2 5 , 4 3 5 , 8 2 5 , 8 3 5 , 1 6 2 5 & 1 6 3 5Nuts with captive

washer are 304 stainless steel fluropolymer coatedLugs are

304 stainless steel Teck™ brackets, easy to assemble

Nuts and washer are 304 stainless steel fluropolymer coated

Gasket compounded to resist water, chemicals and contaminants

Finger or taper style gaskets Lugs are304 stainless steel lifter plate with fingers

FEATURES:• SS304 used for all metal parts to prevent corrosion• Lifter plate option available. Accepted industry-wide• NSF certified, NBR standard with flat gasket and finger joint. Also available with grid gasket with taper joint.• Made to standard pipe sizes, custom sizes available upon request• Available widths 8”, 12”, 16”, 20”, 24” and 32”• 20 gauge Type 304 stainless steel band for corrosion resistance• Economical means of repairing pin hole leaks, punctures and splits in pipe • Available with side outlet 3/4” to 2”, AWWA and FIP

SPECIFICATIONS:The gasket shall be nitrile to resist water, chemicals and contaminants.

The repair clamp shall have all metal parts made of 304 SS. Stainless steel to be fully passivated. LP brackets and studs shall be welded to the bracket. Brackets shall be welded directly to the band. Nuts shall be fluoropolymer coated to prevent galling.

Lifter bar design - no loose parts for assembly.

The Cambridge Brass repair clamp shall have a 20 gauge type 304 stainless steel band. The band shall be a minimum of 8” in width.

Recommended bolt torque - 60 ft./bls.NBR gasket certified to Standard NSF 61.

Studs are 304 stainless steel

Teck™ Fingers design Lifter Plate design

Band is stainless steel 20 gauge