Specification Sheet Part # ATL-150-24 Q max (Watts) 150 Copyright © 2019-2020. All rights reserved. Custom Thermoelectric 11941 Industrial Park Road, STE 5, Bishopville, MD 21813 Tel. 443-926-9135 FAX: 443-926-9137 WEB: www.customthermoelectric.com E-mail: [email protected] All technical information and data in this document is based on tests and measurements and is believed to be accurate and reliable. Product testing by the purchaser is recommended in order to confirm expected results for specific applications. Materials and specifications are subject to change without notice. REV. 3-30-2020 The ATL-150-24 is a thermoelectric based liquid chiller. Six 40x40mm Peltier devices cool a single water block with 3 TECs mounted to each side. The thermoelectric devices are then cooled by a pair of high quality high fin density skived aluminum heat sinks. Air to Liquid (ATL) chillers are used when objects must be cooled with a liquid based recirculation system. Liquid cooling systems are compact and highly efficient. Features: Compact and lightweight. Can be mounted in any orientation. No fluorocarbons or compressor. Virtually maintenance free. Simple quick installation. Includes mounting gasket. Specification Part # ATL-150-24 Description Air to Liquid Assembly Cooling Capacity 150 Watts Input Voltage 24 Volts DC Working Range -10 to 70°C TEC Current (running) 8.2 amps TEC Current (start) 9.8 amps Fan Current 0.35 amps Fan Current NA Weight 3.1 Kg (6.83 lbs) Connectors 1/8-27 NPT, female 2X WIRING DIAGRAM Position Description 1 TEC + 2 TEC - 3 Fan + 4 Fan - Volts 24 1 2 3 4

Upload: others

Post on 11-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Specification Sheet...Specification Sheet Thermal Performance Graph How to use the graph: On the horizontal axis is the desired delta T in Celsius. This is the difference in temperature

Specification Sheet

Part #

ATL-150-24Qmax (Watts)

150

Copyright © 2019-2020. All rights reserved. Custom Thermoelectric 11941 Industrial Park Road, STE 5, Bishopville, MD 21813Tel. 443-926-9135 FAX: 443-926-9137 WEB: www.customthermoelectric.com E-mail: [email protected] technical information and data in this document is based on tests and measurements and is believed to be accurate and reliable. Product testing by the purchaser is recommended in order to confirm expected results for specific applications. Materials and specifications are subject to change without notice. REV. 3-30-2020

The ATL-150-24 is a thermoelectric based liquid chiller. Six 40x40mm Peltier devices cool a single water block with 3 TECs mounted to each side. The thermoelectric devices are then cooled by a pair of high quality high fin density skived aluminum heat sinks. Air to Liquid (ATL) chillers are used when objects must be cooled with a liquid based recirculation system. Liquid cooling systems are compact and highly efficient.Features:

• Compact and lightweight.• Can be mounted in any orientation.• No fluorocarbons or compressor.• Virtually maintenance free.• Simple quick installation.• Includes mounting gasket.

SpecificationPart # ATL-150-24Description Air to Liquid AssemblyCooling Capacity 150 WattsInput Voltage 24 Volts DCWorking Range -10 to 70°CTEC Current (running) 8.2 ampsTEC Current (start) 9.8 ampsFan Current 0.35 ampsFan Current NAWeight 3.1 Kg (6.83 lbs)Connectors 1/8-27 NPT, female 2X

WIRING DIAGRAM

Position Description1 TEC +2 TEC -3 Fan +4 Fan -

Volts

24

1 2 3 4

Page 2: Specification Sheet...Specification Sheet Thermal Performance Graph How to use the graph: On the horizontal axis is the desired delta T in Celsius. This is the difference in temperature

Specification SheetThermal Performance Graph

How to use the graph:On the horizontal axis is the desired delta T in Celsius. This is the difference in temperature between the desired liquid temperature and the ambient outside temperature, Delta T = Tambient-Tout.

On the vertical axis is the required heat pumping in watts.There ia a diagonal line that represent an outside ambient air temperature of 30C (77F).

Example:You have a high power LED circuit board (PCB) that generates 80 watts of heat that must be removed or else the LED circuit will destroy itself. The ambient temperature is 30C. The circuit is mounted to a liquid exchanger (water block) and you are recirculating the water between the water block and this chiller in a closed loop water path. You would like to keep the circuit board at 25C or below. Does this ATL device have the capacity to do this? The desired delta T is 30C - 25C = 5C. The heat load (heat to be removed) is 80 watts. Look at the left hand vertical axis and locate the 80 watts line. Follow a horizontal line at this point so that it intersects with the 30C ambient diagonal line. At the intersection point, draw a vertical line down to the horizontal axis. If you read the bottom horizontal axis where this line intersects, you should find a value around ~21.8C. This means that you could reach a 21.8C delta T while pumping (removing) 80 watts. You only need a 5C delta T, so this device has the capacity to to get the job done easily. The maximum amount of heat that can be removed at a 5C delta T would be ~135 watts.

Copyright © 2020. All rights reserved. Custom Thermoelectric 11941 Industrial Park Road, STE 5, Bishopville, MD 21813Tel. 443-926-9135 FAX: 443-926-9137 WEB: www.customthermoelectric.com E-mail: [email protected] technical information and data in this document is based on tests and measurements and is believed to be accurate and reliable. Product testing by the purchaser is recommended in order to confirm expected results for specific applications. Materials and specifications are subject to change without notice.

Page 3: Specification Sheet...Specification Sheet Thermal Performance Graph How to use the graph: On the horizontal axis is the desired delta T in Celsius. This is the difference in temperature

Specification SheetDimensioned Drawings

Copyright © 2020. All rights reserved. Custom Thermoelectric 11941 Industrial Park Road, STE 5, Bishopville, MD 21813Tel. 443-926-9135 FAX: 443-926-9137 WEB: www.customthermoelectric.com E-mail: [email protected] technical information and data in this document is based on tests and measurements and is believed to be accurate and reliable. Product testing by the purchaser is recommended in order to confirm expected results for specific applications. Materials and specifications are subject to change without notice.