Specification for Flue Options
49241
12/0
3
IKO
N
Supplied By www.heating spares.co Tel. 0161 620 6677
SAUNIER DUVAL SAUNIER DUVAL – STANDARD EFFICIENCY COMBIS, SYSTEM BOILERS & WATER HEATER
32
HORIZONTAL TELESCOPIC TOP REAR OPTIONS
Thema Classic Iso max Opalia Water Heater
L = Flue length, measured from outside wall face to centreline of flue outlet.
If L is between 425mm and 630mm then only the horizontaltelescopic top flue, A2004500, is required.
If L is greater than 630mm then extensions are required.
If L is less than 425mm then use the horizontal top flue,86285H, which can be cut to suit a minimum wall thickness of75mm.
X = Wall thickness
Z = Distance from centre line of flue outlet to inside wall face.
For each additional 90° or 2 x 45° bends fitted the maximumflue length must be reduced by 1m.
The maximum flue length with extensions must not beexceeded (refer to L in table below).
L
X Z
MODEL L MAX WITH SIDE X MM ZEXTENSIONS MIN MAX
1
F24e 3.5m 242 446 184mm
F30e 3.5m 194 398 232mm
F35e 2.5m 194 398 232mm
F24e PLUS 3.5m 194 398 232mm
F30e PLUS 3.5m 194 398 232mm
F18e SB 3.5m 242 446 184mm
F30e SB 3.5m 194 398 232mm
Isomax 3.5m 192 396 234mm
Opalia x13 3.0m 292 496 134mm
1 Horizontal telescopic top flueA2004500
HORIZONTAL ACCESSORIES
2 90° Bend85092H
3 45° Bend85093H
4 1m Extension 85091H
6 Deflector terminaland guard08537300
W = 0.5m max.Flueing examples using extensions and bends.Many others are also possible.
A
A4
1
4
2
1
1
4
2
4
334
W
W
x13F28eF24e, F30e, F35eF24e PLUS, F30e PLUS
F18e SB, F30e SB
Contents
Standard Efficiency Combis, System Boilersand Water HeaterHorizontal Telescopic Top Rear Options
Horizontal Telescopic Top Side Options
Elevated Horizontal Telescopic Top Flue Options
Vertical Flue Options
Twin Flue Options -
Rear Flue Options F30e, F35e, F30e SB, F24e PLUS and F30e PLUS
High Efficiency Condensing BoilersHorizontal Flue Options
Vertical Flue Options
Twin Flue Options
Accessories
Wall Hung Cast Iron BoilerHorizontal Flue Options models 40 - 80 -
Vertical Flue Options models 40 - 80
Easi-Vent Flue Options models 40 - 80
Flue Options
Horizontal Flue Options model 100/120
Vertical Flue Options model 100/120
Flue Options Accessories model 100/120
Vertical Flue Accessories model 100/120Fanned Flue Terminal Positions
Training and Support to help you
22
22
21
20
19
16
1514
18
17
13
12
11
10
87
9
6
5
4
23
3
Supplied By www.heating spares.co Tel. 0161 620 66774
SAUNIER DUVAL – STANDARD EFFICIENCY COMBIS, SYSTEM BOILERS & WATER HEATER
5
ELEVATED HORIZONTAL TELESCOPIC TOP FLUE OPTIONS
L1 = Measured from the vertical flue centre line to the outsidewall face.
L2 = Measured from the top of the boiler to the horizontal fluecentre line (max 0.5m).
L = L1 + L2 = The maximum flue length with extensions,measured from the top of the boiler to the outside wall face.
If more than 1 x 90° or 2 x 45° bends are needed then foradditional 90° bend or 2 x 45° bends fitted the maximum fluelength must be reduced by 1m.
The maximum flue length with extensions must not beexceeded (refer to L in table below).
X = Wall thickness
Y = Distance from the side of the boiler to the inside wall face.
Z = Distance from centre line of flue outlet to the side or rearof the boiler.
1 Horizontaltelescopic top flueA2004500
SIDE
REAR
MODEL L MAX WITH SIDE X MM REAR X MM SIDE Z REAR Z DESCRIPTION PARTEXTENSIONS MIN MAX MIN MAX OF PARTS NUMBER
1 Horizontal A2004500telescopic top flue
2 90° Bend 85092H4 1m Extension 85091H5 Adaptor 85095H
elevated flue
1 2
4
5
F24e 3.5m 201 435 242 476 205mm 184mm
F30e 3.5m 181 415 194 398 225mm 232mm
F35e 2.5m 181 415 194 398 225mm 232mm
F24e PLUS 3.5m 181 415 194 398 225mm 232mm
F30e PLUS 3.5m 181 415 194 398 225mm 232mm
F18e SB 3.5m 201 435 242 476 205mm 184mm
F30e SB 3.5m 181 415 194 398 225mm 232mm
Isomaxleft 3.5m 315 509 192 426 131mm 234mm
right 3.5m 0 171 192 426 469mm 234mm
Opalia x13 3.0m 211 445 292 526 195mm 134mm
L1
L1
L2
X Y Z
X Z
L2
20 mm
ELEVATED HORIZONTAL ACCESSORIES
2 90° Bend85092H
3 45° Bend85093H
5 Adaptor elevated flue85095H 6 Deflector terminal
and guard08537300
4 1m Extension85091H
14
2
2 1 3
1
D
5
4
3
45
4
5
W
WW
W= 0.5m maxFlueing examples using extensions and bends
L= Flue length, measured from outside wall face to centre lineof flue outlet
If L is between 425mm and 630mm then only the horizontaltelescopic top flue, A2004500, is required.
If L is greater than 630mm then extensions are required.
If L is less than 425mm then use the horizontal top flue,86285H, which can be cut to suit minimum wall thickness of75mm.
X= Wall thickness
Z= Distance from centre line of flue outlet to inside wall face.
For each additional 90° or 2 x 45° bends fitted the maximumflue length must be reduced by 1m.
The maximum flue length with extensions must not beexceeded (refer to L in table below).
L
X
20min
Y
MODEL L MAX WITH SIDE X MM ZEXTENSIONS MIN MAX
1
F24e 3.5m 201 405 205mm
F30e 3.5m 181 385 225mm
F35e 2.5m 181 385 225mm
F24e PLUS 3.5m 181 385 225mm
F30e PLUS 3.5m 181 385 225mm
F18e SB 3.5m 201 405 205mm
F30e SB 3.5m 181 385 225mm
Isomaxleft 3.5m 275 479 131mm
right 3.5m 0 141 469mm
Opalia x13 3.0m 211 415 195mm
1 Horizontal telescopic top flueA2004500
HORIZONTAL ACCESSORIES
2 90° Bend85092H
3 45° Bend85093H
4 1m Extension 85091H
6 Deflector terminaland guard08537300
W = 0.5m max.Flueing examples using extensions and bends.
A
2
2
4
HORIZONTAL TELESCOPIC TOP SIDE OPTIONS
Z
W
WA
A
4
3
4
4
4 3A
Supplied By www.heating spares.co Tel. 0161 620 66776
SAUNIER DUVAL – STANDARD EFFICIENCY COMBIS, SYSTEM BOILERS & WATER HEATER
7
TWIN FLUE OPTIONS
CL
= =CL
L1
115mm
115mm
262mm
300mm
ISOMAX ONLYALL MODELS
120mm 120mm
L1L2
L2
850mm
950mm
L= L1 + L2 Maximum available combined flue length (L1 air inlet and L2 flue outlet), measured from top of the boiler (not including the terminal)
For each 90° or 2 x 45° bends fitted the maximum flue lengthmust be reduced by 1m.
MODEL L = L1 air + L2 flue DESCRIPTION OF PARTMax combined flue length PARTS REQUIRED NUMBER
P Twin flue adaptor 085677002 1m Extension 085390004 Vertical roof terminal 085103007 45° Bend 08538800M Twin pipe to concentric 08511800
adaptor
OPTION 1
4
7
P
M
2
2
F24e 38m
F30e 30m
F35e 14m
F24e PLUS 30m
F30e PLUS 30m
F18e SB 38m
F30e SB 30m
Isomax 25m
MODEL L = L1 air + L2 flue DESCRIPTION OF PARTS PARTMax combined flue length PARTS REQUIRED NUMBER
1 Twin flue kit 085679002 1m Extension 085390004 Vertical roof terminal 085103005 Single pipe adaptor 085119006 90° Bend 08538700
OPTION 2
4
2
1
5
1
6
2
F24e 38m
F30e 30m
F35e 14m
F24e PLUS 30m
F30e PLUS 30m
F18e SB 38m
F30e SB 30m
Isomax 25m
VERTICAL FLUE OPTIONS
1195 mm
540 mm
L
L = Flue length, measured from the top of the boiler to theunderside of the roof flashing
If flue length is greater than 3m the condensate trap must befitted. Flue must allow condensate to run back to the boilerwhen trap is fitted.
For each 90° or 2 x 45° bends fitted the maximum flue lengthmust be reduced by 1m.
The maximum flue length must with extensions must not beexceeded (refer to L in table below).
1 Vertical flueadaptor includingcondensate trap08509800
2 Verticalroofterminal08510300
MODEL L MAX WITH DESCRIPTION OF PARTS PARTEXTENSIONS NUMBER
1 Vertical flue adaptor 085098002 Vertical roof terminal 085103003 1m Extension 085099004 Fixing bracket 08512000or 5 Flat roof flashing 085107006 Adjustable pipe 08510000
2
1
3
3
6
VERTICAL FLUE ACCESSORIES
3 1m Extension08509900
6 Adjustable pipe 0 to 270mm08510000(must be used with 1mExtension 08509900)
8 45° Bend08510200
4 Fixing bracket (3 off)08512000
5 Flat roof flashing08510700
7 Pitched roof flashing08510500
J 90° Bend08510100
1
J
2
33
3J
1
8
2
3
3 8
F24e 12.54m
F30e 8.54m
F35e 6.54m
F24e PLUS 8.54m
F30e PLUS 8.54m
F18e SB 12.54m
F30e SB 8.54m
Isomax 12.04m
Supplied By www.heating spares.co Tel. 0161 620 6677
SAUNIER DUVAL – STANDARD EFFICIENCY COMBIS, SYSTEM BOILERS & WATER HEATER
98
MODEL L MAX WITH SIDE X MM DESCRIPTION PART NUMBEREXTENSIONS MIN MAX
A20097F30e 1.5m 75 540
F35e 1.5m 75 540
F24e PLUS 1.5m 75 540
F30e PLUS 1.5m 75 540
F30e SB 1.5m 75 540
1 Rear flue kit
REAR FLUE OPTIONS F30e, F35e, F30e SB, F24e PLUSand F30e PLUS
L = Flue length, measured from the rear of the boiler tooutside wall face.
To achieve the max flue length of 1.5m an extension must beused (85091H).
X = Wall thickness
Y = 115mm
The maximum flue length with extensions must not beexceeded (refer to L in table below).
TWIN FLUE ACCESSORIES
4 Vertical roofterminal08510300
2 1m Extension08539000
M Twin pipe toconcentricadaptor08511800
N Concentrichorizontal terminal08584900
3 Fixing bracket(3off)08511700
K 90° Bend08538700
7 45° Bend08538800
5 Single pipeadaptor08511900
J Pitched roofflashing08510500
6 Flat roofflashing08510700 P Twin flue adaptor
08567700
R Twin terminals08511500
Air inlet and flue outlet terminals must beinstalled so that they are exposed to external air.
If L2 flue outlet is greater than 3m thecondensate trap must be fitted.
1 Twin Flue kit 08567900
Twin flue adaptor andtwin terminals
Condensate trap
MODEL L = L1 air + L2 flue DESCRIPTION OF PARTMax combined flue length PARTS REQUIRED NUMBER
P Twin flue adaptor 085677002 1m Extension 08539000K 90° Bend 08538700M Twin pipe to concentric
adaptor 08511800N Concentric horizontal
terminal 08584900
OPTION 3
F24e 38m
F30e 30m
F35e 14m
F24e PLUS 30m
F30e PLUS 30m
F18e SB 38m
F30e SB 30m
Isomax 25m
K
P
M
N
2
2
2
MODEL L = L1 air + L2 flue DESCRIPTION OF PARTS PARTMax combined flue length PARTS REQUIRED NUMBER
1 Twin flue kit 085679002 1m Extension 08539000
OPTION 4
F24e 38m
F30e 30m
F35e 14m
F24e PLUS 30m
F30e PLUS 30m
F18e SB 38m
F30e SB 30m
Isomax 25m
1
1
1
12
2
2
2
L
X
Y
Supplied By www.heating spares.co Tel. 0161 620 66771110
VERTICAL FLUE OPTIONS
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(M) PARTS REQUIRED NUMBER
A Vertical Flue Adaptor Kit A2024900B Roof Terminal 08510300C 1m Extension Pipe
(as required) 08509900
STRAIGHT2
3
1
NOTE: Total length ofroof terminal (08510300)is 1195mm. Maximumlength of section insideroof space is approx.500mm (assumingthickness of roof = 75mm)
*Plus the Terminal assembly
ALL 8m*
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(M) PARTS REQUIRED NUMBER
A Vertical Flue Adaptor Kit A2024900B Roof Terminal 08510300C 1m Extension Pipe
(as required) 085099004 90˚ Bends
(as required) 08510100
90˚ BENDS2
3
1
NOTE: Total length ofroof terminal (08510300)is 1195mm. Maximumlength of section insideroof space is approx.500mm (assumingthickness of roof = 75mm)
ALL 8m*
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(M) PARTS REQUIRED NUMBER
A Vertical Flue Adaptor Kit A2024900B Roof Terminal 08510300C 1m Extension Pipe
(as required) 085099004 45˚ Bends
(as required) 08510200
45˚ BENDS
2
3
4
3
4
1
NOTE: Total length ofroof terminal (08510300)is 1195mm. Maximumlength of section insideroof space is approx.500mm (assumingthickness of roof = 75mm)
ALL 8m*
44
SAUNIER DUVAL – HIGH EFFICIENCY CONDENSING BOILERS
ENVIROPLUS
MODEL MAX LENGTH OF DESCRIPTION OF PARTSTANDARD PACK PARTS REQUIRED NUMBER
A Standard Horizontal Flue Kit A2024800
STANDARD HORIZONTAL FLUE
MODEL MAX FLUE DESCRIPTION OF PARTLENGTH (m) PARTS REQUIRED NUMBER
A Standard Horizontal Flue Kit A2024800B 1m Extension Pipe
(as required) 08545200C 90° Bends (as required) 08545400
STANDARD HORIZONTALEXTENDED FLUE
A
A
2
*For each 90˚ bend fitted the maximumflue length must be reduced by 1 metre
3
MODEL MAX FLUE DESCRIPTION OF PARTLENGTH (m) PARTS REQUIRED NUMBER
A Standard Horizontal Flue Kit A2024800B 1m Extension Pipe
(as required) 08545200C 90° Bends (as required) 08545400
STANDARD HORIZONTALELEVATED FLUE
A
2
2
*For each 90˚ bend fitted the maximumflue length must be reduced by 1 metre
3
ALL 755mm
ALL 3.5m*
ALL 3.5m*
HORIZONTAL FLUE OPTIONS
Enviro PLUSF28e, F28e SB
SEDBUK ‘A’ Rated
*For each 90˚ bend or 2 x 45˚ bends fitted the maximum flue length must bereduced by 1 metre
*For each 90˚ bend or 2 x 45˚ bends fitted the maximum flue length must bereduced by 1 metre
Supplied By www.heating spares.co Tel. 0161 620 66771312
ACCESSORIES
TWIN FLUE ACCESSORIES
VERTICAL FLUE ACCESSORIESHORIZONTAL ACCESSORIES
90˚ BEND08545400
1 METRE PIPE EXTENSION08545200
1 METRE PIPEEXTENSION08509900
FIXING BRACKET 125¢08512000
SINGLE PIPE TOTERMINAL ADAPTOR08511900
TWIN PIPE TOCONCENTRIC ADAPTOR08511800 HORIZONTAL FLUE
TERMINALS08511500
FIXING BRACKET 80¢08511700
FLAT ROOFWEATHER COLLAR08510700
45˚ BEND08538800
90˚ BEND08538700
PITCHED ROOFWEATHER COLLAR08510500
1 METRE OUTLETEXTENSION PIPE08547800
0.5 METRE FLUEEXTENSION PIPE08547600
CONCENTRIC HORIZONTALTERMINAL08584900
0.5 METRE AIREXTENSION PIPE08547200
0-270mm ADJUSTABLE PIPEmust be used with 0850990008510000
FIXINGBRACKET08512000
PITCHED ROOFWEATHER COLLAR08510500 90˚ BEND
08510100
FLAT ROOFWEATHER COLLAR08510700
45˚ BEND08510200
SAUNIER DUVAL – HIGH EFFICIENCY COMBI & SYSTEM CONDENSING BOILERS
TWIN FLUE OPTIONS
MODEL MAX FLUE DESCRIPTION OF PARTLENGTH (m) PARTS REQUIRED NUMBER
A Twin Flue Adaptor Kit A20250002 Roof Terminal 085103003 Horizontal Twin Flue Terminals 085115004 1m Extension Pipe 085478005 90° Bends (as required)* 085387006 45° Bends (as required)* 085388007 Single Pipe to Terminal Adaptor 085119008 Twin Pipe to Concentric Adaptor 085118009 Concentric Horizontal Terminal 08584900
NOTE: Maximum 20 metres combined air and flue ducting.(eg. 10 metres air + 10 metres flue = 20 metres).
Total length of roof terminal (08510300) is 1195mm.Maximum length of section inside roof space is approx 500mm(assuming thickness of roof = 75mm).
*Plus the Terminal assembly and a maximum of4 x 90˚ bends or alternatively 8 x 45˚ bends.
ALL 20 metres
FLUE OPTIONS FLUE OPTIONS
FLUE OPTIONS
FLUE OPTIONS
ROOF TERMINAL08510300
TERMINAL
FITTINGS PACK
VERTICAL FLUE ADAPTOR KITA2024900
STANDARD HORIZONTAL FLUE KITA2024800
TWIN FLUE ADAPTOR KITA2025000
11
2
444
4
4
55
6
78
5
4
33
2
2
1
4
4
5
8
9
Supplied By www.heating spares.co Tel. 0161 620 66771514
HORIZONTAL FLUE OPTIONS models 40-80FF
MODEL MAX FLUE X (MAX) DESCRIPTION OF PARTLENGTH (m) (m) PARTS REQUIRED NUMBER
A Terminal Pack (Bend) 2000448486B 1m Flue / Air Duct Kit 2000448490
orB 2m Flue / Air Duct Kit 2000448491
orB 3m Flue / Air Duct Kit 2000448485C Flue Bend Kit (2 Required) 438130
2x90˚BENDS
A
2
NOTE: Max. flue length doesnot include flue bends.
3
3
X
MODEL MAX FLUE X (MAX) DESCRIPTION OF PARTLENGTH (m) (m) PARTS REQUIRED NUMBER
A Terminal Pack (Bend) 2000448486B 1m Flue / Air Duct Kit 2000448490
orB 2m Flue / Air Duct Kit 2000448491
orB 3m Flue / Air Duct Kit 2000448485C Flue Bend Kit (1 Required) 438130
2x45˚BENDS
A
2
NOTE: Max. flue length doesnot include flue bends.
3
3
X
MODEL MAX FLUE X (MAX) DESCRIPTION OF PARTLENGTH (m) (m) PARTS REQUIRED NUMBER
A Terminal Pack (Bend) 2000448486B 1m Flue / Air Duct Kit 2000448490
orB 2m Flue / Air Duct Kit 2000448491
orB 3m Flue / Air Duct Kit 2000448485C Flue Bend Kit (1 Required) 438130
1x90˚BEND
A
2
NOTE: Max. flue length doesnot include flue bends.
3
X
40FF 3m 1m
50FF 3m 1m
60FF 3m 1m
80FF 1.5m 0.5m
40FF 3m 1m
50FF 3m 1m
60FF 3m 1m
80FF 1.5m 0.5m
40FF 3m 2.7m
50FF 3m 2.7m
60FF 3m 2.7m
80FF 3m 2.2m
SAUNIER DUVAL – WALL HUNG CAST IRON BOILERS
HORIZONTAL FLUE OPTIONS models 40-80FF
Xeon Cast-iron
MODEL MAX LENGTH OF DESCRIPTION OF PARTSTANDARD PACK PART REQUIRED NUMBER
40FF 510mm
50FF 510mm
60FF 510mm
Standard Flue Pack 900858(Complete with Flue / Air Duct)
80FF 510mm
MODEL MAX FLUE DESCRIPTION OF PARTLENGTH (m) PARTS REQUIRED NUMBER
40FF 3m A Terminal Pack 2000448473
50FF 3m B 1m Flue / Air Duct Kit 2000448490or
60FF 3m B 2m Flue / Air Duct Kit 2000448491
or80FF 3m B 3m Flue / Air Duct Kit 2000448485
STANDARD HORIZONTAL FLUE
EXTENDED HORIZONTAL FLUE
STRAIGHT
2
A
MODEL MAX FLUE DESCRIPTION OF PARTLENGTH (m) PARTS REQUIRED NUMBER
A Terminal Pack (Bend) 2000448486B 1m Flue / Air Duct Kit 2000448490
orB 2m Flue / Air Duct Kit 2000448491
orB 3m Flue / Air Duct Kit 2000448485C Flue Bend Kit (1 Required) 438130
1x90˚BEND
3
A
2NOTE : Max flue length does notinclude flue bend.
MODEL MAX FLUE DESCRIPTION OF PARTLENGTH (m) PARTS REQUIRED NUMBER
A Terminal Pack (Bend) 2000448486B 1m Flue / Air Duct Kit 2000448490
or B 2m Flue / Air Duct Kit 2000448491
orB 3m Flue / Air Duct Kit 2000448485C Flue Bend Kit (2 Required) 438130
2x90˚BENDSA
2
NOTE : Max flue lengthdoes not include fluebends.
3
40FF 3m
50FF 3m
60FF 3m
80FF 3m
40FF 3m
50FF 3m
60FF 3m
80FF 1.2m
40, 50, 60, 80
Supplied By www.heating spares.co Tel. 0161 620 66771716
EASI-VENT VERTICAL FLUE OPTIONS models 40-80FF
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(MM) X+Y+Z PARTS REQUIRED NUMBER
A Easi-Vent Vertical FlueTerminal Kit 2000448495
B 1m Flue / Air Duct 2000448490
or
B 2m Flue / Air Duct 2000448491
or
B 3m Flue / Air Duct 2000448485
STRAIGHT 1
2
NOTE: Max. FlueLength does notinclude Terminal.(120mm High)X(Min.) = 500mm
X
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(MM) X+Y+Z PARTS REQUIRED NUMBER
A Easi-Vent Vertical FlueTerminal Kit 2000448495
B 1m Flue / Air Duct 2000448490
or
B 2m Flue / Air Duct 2000448491
or
B 3m Flue / Air Duct 2000448485
3 Flue Bend Kit (2 Required) 438130
2x90˚BENDS1
2
33
NOTE: Max. FlueLength does notinclude Terminal(120mm High) orFlue Bends.X(Min.) = 39mmY(Min.) = 0mmY(Max.) = 1000mmZ(Min.) = 500mm
Z
YX
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(MM) X+Y+Z PARTS REQUIRED NUMBER
A Easi-Vent Vertical FlueTerminal Kit 2000448495
B 1m Flue / Air Duct 2000448490
orB 2m Flue / Air Duct 2000448491
orB 3m Flue / Air Duct 2000448485
3 Flue Bend Kit (1 Required) 438130
2x45˚BENDS 1
2
32
3
NOTE: Max. FlueLength does notinclude Terminal(120mm High) orFlue Bends.X(Min.) = 39mmY(Min.) = 0mmZ(Min.) = 500mm
Z
YX
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(MM) X+Y+Z PARTS REQUIRED NUMBER
A Easi-Vent Vertical FlueTerminal Kit 2000448495
B 1m Flue / Air Duct or 2000448490
B 2m Flue / Air Duct or 2000448491
B 3m Flue / Air Duct 2000448485
3 Flue Bend Kit (1 Required) 438130
1x90˚BEND 1
2
32
NOTE: Max. FlueLength does notinclude Terminal(120mm High) orFlue Bend.Y(Min.) = 39mmZ(Min.) = 500mm
Z
Y
40FF 3m
50FF 3m
60FF 3m
80FF 3m
40FF 1.5m
50FF 1.5m
60FF 1.5m
80FF 1.5m
40FF 1.5m
50FF 1.5m
60FF 1.5m
80FF 1.5m
40FF 1.5m
50FF 1.5m
60FF 1.5m
80FF 1.5m
SAUNIER DUVAL – WALL HUNG CAST IRON BOILERS
VERTICAL FLUE OPTIONS models 40-80FF
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(MM) X+Y+Z PARTS REQUIRED NUMBER
A Vertical Flue Kit 2000448451B Vertical Flue Terminal 2000448494C 1m Flue / Air Duct 2000448490
orC 2m Flue / Air Duct 2000448491
orC 3m Flue / Air Duct 2000448485
STRAIGHT2
3
1X
NOTE: Max. FlueLength does notinclude Terminal. X(Min.) = 39mm
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(MM) X+Y+Z PARTS REQUIRED NUMBER
A Vertical Flue Kit 2000448451B Vertical Flue Terminal 2000448494C 1m Flue / Air Duct 2000448490
orC 2m Flue / Air Duct 2000448491
orC 3m Flue / Air Duct 20004484854 Flue Bend Kit (2 Required) 438130
2x90˚BENDS2
3
1
44
X
Z
Y
NOTE: Max. FlueLength does notinclude Terminal orFlue Bends.X(Min.) = 39mmY(Max.) =1000mmY(Min.) = 0mmZ(Min.) = 0mm
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(MM) X+Y+Z PARTS REQUIRED NUMBER
A Vertical Flue Kit 2000448451B Vertical Flue Terminal 2000448494C 1m Flue / Air Duct 2000448490
orC 2m Flue / Air Duct 2000448491
orC 3m Flue / Air Duct 20004484854 Flue Bend Kit (1 Required) 438130
2x45˚BENDS
2
3
1
43 4
X
Z
Y
NOTE: Max. FlueLength does notinclude Terminal orFlue Bends. X(Min.) = 39mmY(Min.) = 0mmZ(Min.) = 0mm
40FF 3m
50FF 3m
60FF 3m
80FF 3m
40FF 1.5m
50FF 1.5m
60FF 1.5m
80FF 1m
40FF 3m
50FF 3m
60FF 3m
80FF 2m
Supplied By www.heating spares.co Tel. 0161 620 667718
SAUNIER DUVAL – WALL HUNG CAST IRON BOILERS
19
HORIZONTAL FLUE OPTIONS model 100/120FF only
MODEL MAX LENGTH OF DESCRIPTION OF PARTSTANDARD PACK PARTS REQUIRED NUMBER
100/120FF 510mm Standard Flue Pack 2000448901(Complete with Flue / Air Duct Kit)
MODEL MAX FLUE DESCRIPTION OF PARTLENGTH (m) PARTS REQUIRED NUMBER
A Elbow / Terminal Pack 2000448465
B 1m Flue / Air Duct Kit or 2000448488
B 2m Flue / Air Duct Kit or 2000448489
B 3m Flue / Air Duct Kit 2000448484
STANDARD HORIZONTAL FLUE
EXTENDED HORIZONTAL FLUE
STRAIGHT
A
2
A
MODEL MAX FLUE DESCRIPTION OF PARTLENGTH (m) PARTS REQUIRED NUMBER
A Elbow / Terminal Pack 2000448465
B Flue Support Kit 448697
C 1m Flue / Air Duct Kit or 2000448488
C 2m Flue / Air Duct Kit 2000448489
D 90° Flue Bend 448695
1x90˚BEND
X
B
C
D
A
NOTE: Max. Flue Lengthdoes not include Flue Bend.X(Max.) = 1500mm
MODEL MAX FLUE DESCRIPTION OF PARTLENGTH (m) PARTS REQUIRED NUMBER
A Elbow / Terminal Pack 2000448465
B 1m Flue / Air Duct Kit 2000448488
C 90° Flue Bend 448695
1x90˚BEND
B C
1
A
MODEL MAX FLUE DESCRIPTION OF PARTLENGTH (m) PARTS REQUIRED NUMBER
A Elbow / Terminal Pack 2000448465
B 1m Flue / Air Duct Kit 2000448488
C 45° Flue Bend 448696
2x45˚BENDS
B
1 A
NOTE: Max. Flue Length does notinclude Flue Bends.
100/120FF 2m
100/120FF 2m
100/120FF 1m
100/120FF 1m
C
NOTE: Max. Flue Length does not include Flue Bend.
FLUE OPTIONS models 40-80FF
STANDARD FLUE PACK 900858
FOAM SEAL
FLUE DUCTTERMINAL ASSEMBLY
VERTICAL FLUE TERMINAL2000448494
TERMINAL
EASI-VENT VERTICAL FLUE PACK2000448495
VERTICAL FLUE PACK2000448451
TERMINAL FITTINGSPACK
AIR DUCTADAPTOR
FLUE DUCTCONNECTOR
PILOTSHIELD
FLUE DUCTADAPTOR
ROOF PLATE
PIPE CLIP
FITTINGSPACK
RESTRICTOR70 & 80FF
RESTRICTOR30 & 60FF
TERMINAL KIT2000448473
TERMINALFITTINGSPACK
FLUE BEND KIT438130
45° FLUE BENDS (2)
FITTINGS PACK
AIR DUCTTRANSITION
FLUE DUCTTRANSITION
1M EXTENSION KIT 20004484902M EXTENSION KIT 20004484913M EXTENSION KIT 2000448485
AIR DUCT
FLUE DUCTFITTINGSPACK
FLUE BEND TERMINAL KIT2000448486
TERMINALFITTINGSPACK
VERTICAL FLUESTANDARD VERTICAL FLUEFLAT ROOF - Part Number 2000208596*PITCHED ROOF - FOR TILES Part Number 2000208600*
FOR SLATE Part Number 2000208595*EASI-VENT VERTICAL FLUEFLAT ROOF - RITE VENT Part Number 015203*
SELKIRK Part Number 2803804*PITCHED ROOF - RITE VENT Part Number 015103*
SELKIRK Part Number 2803504*
*Note: With appropriate storm collars
WEATHER COLLARS HORIZONTAL FLUEAND VERTICAL FLUE
FLUE COLLAR443286
FIRE STOP PLATE2000208592 CEILING
COLLAR2000208590
CEILINGPLATE2000208593
WALL BAND2000208594
ACCESSORIES
FLUECONNECTOR447994
WALLLINER900862
SUPPORTASSEMBLY2000208591
Supplied By www.heating spares.co Tel. 0161 620 66772120
STANDARD FLUE PACK 2000448901
VERTICAL FLUE TERMINAL2000448494
VERTICAL FLUE KIT2000448455
1M EXTENSION KIT 20004484882M EXTENSION KIT 20004484893M EXTENSION KIT 2000448484
45° FLUE BEND KIT448696
FLUE SUPPORT KIT448697
ELBOW/TERMINAL KIT2000448465
FLUEELBOW TERMINAL
ASSEMBLYFITTINGSPACK
TERMINAL
FLUEELBOW
FLUE DUCT
TERMINAL
45° FLUEBENDS
AIR DUCTADAPTOR
FLUE DUCTADAPTOR
PIPE CLIP
ROOF PLATEFITTINGSPACK
SUPPORTSPIGOT GASKET
SUPPORTSPIGOT
FLUE DUCTCONNECTOR
SUPPORTSPIGOT
FLUE DUCTCONNECTOR
SUPPORTSPIGOT GASKET
AIR DUCT
FLUE DUCT FITTINGS PACK
FITTINGS PACK
90° FLUE BEND KIT448695
90° FLUEBENDS
FITTINGS PACK
VERTICAL FLUESTANDARD VERTICAL FLUE
FLAT ROOF - Part Number 2000208596*
PITCHED ROOF-FOR TILES Part Number 2000208600*-FOR SLATE Part Number 2000208595*
*Note: With appropriate storm collars
WEATHER COLLARS HORIZONTAL FLUE
ADJUSTABLEWALL BAND2000208639
PIPE CLIP447974
CEILING COLLAR2000208638
FIRE STOPPLATE2000208641
WALL LINER900861
SUPPORT ASSEMBLY2000208640
CEILING PLATE2000448694
FLUE ELBOW KIT2000448466
FLUEELBOW
FITTINGSPACK
ACCESSORIES
FLUE OPTIONS ACCESSORIES model 100/120FF only
SAUNIER DUVAL – WALL HUNG CAST IRON BOILER
VERTICAL FLUE OPTIONS model 100/120FF only
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(MM) X+Y+Z PARTS REQUIRED NUMBER
A Vertical Flue Kit 2000448455
B Vertical Flue Terminal 2000448494
C 1m Flue / Air Duct Kit or 2000448488
C 2m Flue / Air Duct Kit 2000448489
STRAIGHT
2
3
1
X
NOTE: Max. Flue Lengthdoes not includeTerminal.X(Min.) = 105mm
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(MM) X+Y+Z PARTS REQUIRED NUMBER
A Vertical Flue Kit 2000448455
B Vertical Flue Terminal 2000448494
C 1m Flue / Air Duct Kit 2000448488
D 90° Flue Bend 448695
E Boiler Elbow Kit 2000448466
1x90˚BEND& BOILERELBOW
NOTE: Max. FlueLength does notinclude Terminal,Flue Bends or Boiler Elbow. X(Min.) = 29mmY(Max.) = 30mm
X Y
2
3
54
1
MODEL MAX FLUE LENGTH DESCRIPTION OF PART(MM) X+Y+Z PARTS REQUIRED NUMBER
A Vertical Flue Kit 2000448455
B Vertical Flue Terminal 2000448494
C 1m Flue / Air Duct Kit or 2000448488
C 2m Flue / Air Duct Kit 2000448489
D 45° Flue Bend 448696
2x45˚BENDS
NOTE: Max. FlueLength does notinclude Terminalor Flue Bends. X(Min.) = 102mmY(Min.) = 27mm Z(Min.) = 30mm
X
Z
Y
2
3
44
1
100/120FF 1985mm
100/120FF 1m
100/120FF 1.5m
Supplied By www.heating spares.co Tel. 0161 620 667722
SAUNIER DUVAL – WALL HUNG CAST IRON BOILER
23
FIRESTOP PLATE - 2000208641Manufactured fromgalvanised steel and fittedwith spacer lugs whichensure that a distance of50mm is maintained betweenthe inner liner of the flue andany combustible material.
CEILING PLATE - 2 PIECE -2000448694Manufactured fromgalvanised steel and shouldbe used on the under side ofthe floor joists where the fluepasses through the floor orroof in a non-vertical plane.
CEILING COLLAR - 2000208638Used if required as a ceilingtrim immediately below the ceiling to make a neatinstallation.
SUPPORT ASSEMBLY -2000208640Manufacture from galvanisedsteel and incorporates a firestop feature fitted withspacer lugs and supportcollar. This item should beused to support the flue at thetop of each floor joist andprovide a fire stop feature.
TYPICAL ARRANGEMENT
VERTICAL FLUE ACCESSORIES model 100/120FF only TRAINING AND SUPPORT TO HELP YOU
WEATHERCOLLAR
CEILING PLATE
WALL BAND
SUPPORTASSEMBLY
FIRE STOP
CEILING COLLAR
The more you know about boilers, the faster and
more efficient you become at installing them. So to
help you to improve your knowledge of Saunier
Duval in particular, and boilers in general, we now
offer technically based courses across the UK.
Each of the one-day courses has been designed to help Corgi
registered installers, and they can be tailored to suit your
requirements, whether individually or as part of a group.
The three courses are:
Basic/Performance Boilers/System (Thema Classic Range),together with specific installation information.
Advanced Combination Boiler, Isomax.
High Efficiency Condensing Boilers, based around theEnviroPLUS range, to help where preserving the environment is a primary concern.
All the courses cover installation practices, flue options, system
design, commissioning, servicing and fault finding.
They are based in Scotland, Dublin, Manchester, Derby, Norwich,
South Wales, London, Exeter and Bournemouth, so that wherever
you are in the country, you will find one close to you.
For more information, callSaunier Duval Training Services on
01773 596174
3
1
2
Training on self-diagnosticsis included on all courses.
Purpose designed lectureroom with appliances tohand.
5
4
Instruction given on theremoval of all components.
Commissioning instruction.
Investment in regional train-ing facilities cuts down ontravelling time for installers.
3
2
1
1
2
3
4
5
MINIMUM SITING DIMENSIONS FOR THE POSITIONING OF FLUE TERMINALS MMHORIZONTAL FLUESA Directly below, above or horizontally to
an opening, air brick, opening windows, air vent, or any other ventilation opening 300
B Below gutter, drain/soil pipe 75C Below eaves 200D Below a balcony or car port 200E From vertical drain pipes and soil pipes 150F From internal/external corners or to a
boundary alongside the terminal 300G Above adjacent ground or balcony level 300H From surface or a boundary facing the
terminal 600I Facing terminals 1200J From opening (door/window) in car port
into dwelling 1200K Vertical from a terminal 1500L Horizontal from a terminal 300
MINIMUM SITING DIMENSIONS FOR THE POSITIONING OF FLUE TERMINALS MMVERTICAL FLUESM From adjacent wall to flue 300N From another terminal 600P From adjacent opening window 1000Q Above roof level 300
FANNED FLUE TERMINAL POSITIONS all models/ranges