specialist in specific proteins supplier of optimized solution for liquid clinical chemistry
DESCRIPTION
Specialist in Specific Proteins Supplier of optimized solution for liquid clinical chemistry. Company History. 1993 founded by Dr Gilbert Ameryckx as LTD 2003 CE registration for all products 2005 certification for ISO 9001-2000 2005 certification for ISO 13485 - PowerPoint PPT PresentationTRANSCRIPT
Meeting LABIMMUN/DIAGAM. 01.12.11.
Specialist in Specific ProteinsSupplier of optimized solution for
liquid clinical chemistry
Meeting LABIMMUN/DIAGAM. 01.12.11.
Company History
1993 founded by Dr Gilbert Ameryckx as LTD 2003 CE registration for all products 2005 certification for ISO 9001-2000 2005 certification for ISO 13485 2009 certification for ISO 9001-2008 2008 member of the European BIO & Diagnostic Cluster BIOWIN and
WallDX 2009 foundation of nanoQ, LTD sister Company specialized in the
synthesis and coating of metallic nanoparticles 2010 implementation of the standard 15185 in the establishment of
technical records
Meeting LABIMMUN/DIAGAM. 01.12.11.
HUMAN RESSOURCES
Ph.D.
Post Graduates
Graduates
Sales and MarketingR+DQA/QCProduction
22%
26%
18%
34%
34%
22%
18%
26%
23%
23%
39%
39%
38%
38%
Qualifications distribution Functions distribution
Meeting LABIMMUN/DIAGAM. 01.12.11.
Manufactured Products: specific proteinsAlbuminAlpha1-glycoprotein acidAlpha1-antitrypsinAlpha2-macroglobulinAntithrombin IIIApolipoprotein A1Apolipoprotein BASOCeruloplasminC3C4
CRP XL "Wide Range“CRP XSRhumatoid FactorFerritinFibrinogenHaptoglobinIgA, IgG, IgMLipoprotein (a) (Lpa)MicroalbuminPrealbuminTransferrin
Meeting LABIMMUN/DIAGAM. 01.12.11.
Available for opened analyzers
AdviaAerosetAlcyonArchitectAU seriesCobas MiraCobas 6000Cobas 8000CXDXC
Fusion FS 5.1Hitachi seriesKonelab seriesIntegra seriesModularSelectraTargaVistaVitros 5600…and more…
Meeting LABIMMUN/DIAGAM. 01.12.11.
Strenghts: some exemples
CRP XLRF
MICROALBUMIN
Meeting LABIMMUN/DIAGAM. 01.12.11.
Strenghts: CRP XL Principle:
Immunoturbidimetry with ready to
use reagent, calibrator and control
Measuring range:0.8 – 300 mg/l
Accuracy:standardized on ERM-DA474
Bar-codes available for: Modular, Hitachi, AU, Konelab…
ModularCRPXL calibration curve
0
100
200
300
400
500
600
700
800
900
1000
0 5 10 15 20 25 30
concentration mg/dl
mO
DU
340
nm
10 µl E+180 µl R1+26 µl R2
Source: CPTXLHMODE/ACN704/GA/04/04/2008. Gilly
Meeting LABIMMUN/DIAGAM. 01.12.11.
Strenghts: RF Principle:
Immunoturbidimetry (with colloidal
gold particles) with ready to use
reagent, calibrator and control
Measuring range:1.2 – 120 KIU/l
Accuracy:Standardized on WHO W1066
Bar-codes available for: Modular, Hitachi, AU, Konelab…
-------- : DIAGAM (colloidal gold particles)
-------- : Latex based methods
Source: RFCOLHMODE/JOCKER/SQ/03/04/07. BAUDUIN.
ModularRheumatoid Factor Calibration curve
0
500
1000
1500
2000
2500
0 20 40 60 80 100 120
Concentration IU/mlmO
DU 60
0 nm
3 µl S+150 µl R1+100 µl R2
Meeting LABIMMUN/DIAGAM. 01.12.11.
Strenghts: MICROALBUMIN Principle:
Immunoturbidimetry with ready to
use reagent, calibrator and control
Measuring range:3.6 – 500 MG/l
Accuracy:Standardized on ERM-DA470k
Bar-codes available for: Modular, Hitachi, AU, Konelab… Source: MATURHMOD ACN005 E/AR/14/04/2009
ModularMicroalbumin calibration curve
0
2000
4000
6000
8000
10000
12000
0 50 100 150 200 250 300
Concentration mg/L
O.D
. 340
nm
15 µl S+250 µl R1+50 µl R2
Meeting LABIMMUN/DIAGAM. 01.12.11.
R+D Products and TechnologyCYSTATIN C & D DIMERS
METALLIC NANOPARTICLES
COATING