Solid Phase Extraction Solutions
SPE
SPE_Cover.indd 2 11/7/2008 1:46:41 PM
i 608-836-1551 • 800-445-7661 • www.gilson.com Solid Phase Extraction Solutions ii
Introduction
Gilson offers the broadest array of SPE instruments on the market today, including the
GX-271 ASPEC™, the GX-274 ASPEC™, the SPE 215 and virtually any other Gilson instrument
that accommodates the Code 300 Series Racks. These systems are ideal for pharmaceutical, food &
beverage, clinical, forensic and environmental applications.
Fundamental to Gilson’s automated Solid Phase Extraction (SPE) system is our Mobile Rack and
Positive Pressure technology. The Mobile Rack technology allows you to automate your entire SPE
and Liquid Handling process from the initial condition to the fi nal transfer. Gilson’s SPE instruments
utilize Positive Pressure to ensure more reproducible fl ow rates and recoveries, less sample to sample
contamination and higher precision.
TRILUTION® LH provides an intuitive interface for creating SPE and liquid handling protocols/applications
to condition cartridges, load the sample, wash the cartridge, elute the analyte of interest and transfer the
eluent to a fi nal sample vessel or inject it
directly onto an HPLC or LC/MS system.
Available with a single probe,
multiple probe, or spannable
multiple probe instrument, Gilson
has an SPE and liquid handling
instrument solution to fi t your needs.
Solid Phase Extraction System Features . . . . . . . . . . 1–2
GX-271 ASPEC™ . . . . . . . . . . . . . . . . . . . . . . . . 3–4
GX-274 ASPEC™ . . . . . . . . . . . . . . . . . . . . . . . . 5–6
SPE 215 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–8
TRILUTION® LH . . . . . . . . . . . . . . . . . . . . . . . . . 9–10
Code 300 Series Racks . . . . . . . . . . . . . . . . . . . . .11
Automating SPE . . . . . . . . . . . . . . . . . . . . . . . .12
All of Gilson’s SPE and Liquid
Handling instruments are controlled
via TRILUTION® LH software.
TRILUTION LH was designed
with you, the user, in mind. The
graphical interfaces decrease the
learning curve while increasing
your effi ciency. TRILUTION LH allows
you to concentrate on the science,
not the software.
As is the case with all Gilson
instruments, the SPE and liquid
handling instruments are extremely
versatile, modular and robust. Gilson’s SPE instruments are versatile enough to adapt as your science changes and
robust enough to guarantee a low cost of ownership and a workhorse instrument for years to come.
GX-271 ASPECTM with406 Single Syringe Pump
SPE 215 with 849 Multiple Injection Module
1 608-836-1551 • 800-445-7661 • www.gilson.com Solid Phase Extraction Solutions 2
Solid Phase Extraction System Features
GX-274 ASPEC TM with two 406 Dual Syringe Pumps
The 406 Single and Dual Syringe Pumps
deliver Positive Pressure via a gas cylinder
or the syringes. (To achieve more accurate
fl ow rates, use the syringes for the air push.)
Optional peripherals such as injectors,
on-bed solvent reservoirs, three-way valves
and peristaltic pumps extend the capabilities
of your instrument and allow you to tailor
the instrument to meet your specifi c needs.
Compatible with the most common and
widely accepted SPE cartridges and
96-well extraction plates, the Gilson
instruments are capable of utilizing
1, 3 and 6 mL SPE cartridges as well
as 96-well extraction plates.
On-bed rinse stations minimize
carryover and cross-contamination
concerns.
Pressure is constantly monitored and recorded
through pressure sensing modules to immediately
identify a change in performance, cartridge failure
or plugged solvent lines.
Gilson’s newest and most powerful SPE and liquid
handling software yet, TRILUTION® LH allows complete
control of the entire system.
Mobile Rack
technology allows
the user to perform
typical liquid
handling tasks as
well as SPE tasks
from the same
bed layout.
Positive Pressure
elutions guarantee
more reproducible
results, higher
percent recoveries
and more consistent
fl ow rates.
3 608-836-1551 • 800-445-7661 • www.gilson.com Solid Phase Extraction Solutions 4
GX-271 ASPEC™
SPE is the technique of
choice for sample clean-
up, sample prep and trace
analyte enrichment due
to its inherent versatility,
selectivity, speed and low
solvent usage. Gilson’s
GX-271 ASPEC is the ideal
solution to automate
solid phase extraction for
pharmaceutical, food &
beverage, clinical, forensic or
environmental applications.
Automated Solid Phase Extraction, Liquid Handling and on-line injection capabilities
608-836-1551 • 800-445-7661 • www.gilson.com
° Operate in both Batch and Sequential mode to increase throughput and efficiency.
° On-bed reservoirs allow access up to four solvents without taking up a valuable rack position.
° Accommodates 1, 3 and 6 mL SPE cartridges.
° Mobile Rack technology enables use as both an SPE instrument as well as a liquid handling instrument.
° Multiple rinse stations with optional rinse pump allows multiple rinsing parameters depending on the application need.
° The 406 Single and Dual Syringe Pumps are equipped with pressure sensing modules that monitor pressure and can be used to handle error conditions such as high cartridge pressure or clogged liquid lines.
° 406 Single and Dual Syringe Pumps enable air pushes from both syringes and external air sources.
° Eluted product can be fractionated by moving to different collection tubes for applications such as buffer or pH step gradients.
° GX Direct Injection Module can be integrated for performing on-line injections onto HPLC or LC/MS systems.
° Positive Pressure achieved via Gilson’s unique and innovative Sealing Cap design.
° Modular design allows the use of Code 20, Code 200, Code 34X and Code 37X Series racks.
Designed with today’s laboratory in mind, the GX Series of
instruments have large cartridge capacities while minimizing the
amount of linear bench space consumed. System performance is
constantly monitored by a pressure sensing module. Carryover
and contamination concerns are minimized through the use of
Gilson’s revolutionary jet wash rinse stations. The combination of
throughput with the ability
to run unattended
makes this instrument
an ideal choice for SPE,
sample prep, sample
clean-up and
GPC/SPE
applications.
1 mL3 mL6 mL
GX-271 ASPEC TM with406 Single Syringe Pump
On-bed injection capabilities
Mobile Racks allow access to both SPE cartridges as well as collection vials
GX-271 ASPEC with on-bed solvent reservoirs
406 Single Syringe Pump
System Overview
Cartridge Types 1, 3, 6 mL Cartridges
Air Push Modes Syringe or Gas Cylinder Valve
On-bed Options Reservoirs, Direct Injection Module
Dimensions (w x d x h) 59.6 x 53.9 x 57 cm (23.5 x 21.25 x 22.46 in)
Cartridge Capacities* 108 – 1 mL cartridges 60 – 3 mL cartridges 45 – 6 mL cartridges*Assumes 3 tray positions used for SPE Mobile Racks.
5 608-836-1551 • 800-445-7661 • www.gilson.com Solid Phase Extraction Solutions 6
GX-274 ASPEC™
Gilson’s multiple probe
instruments give you the
ability to maximize your
effi ciency and throughput
by unattended, parallel
processing of samples.
Simply place the samples
on the instrument, and the
SPE cartridges in the
Mobile Racks, then fi ll
any solvent reservoirs.
Next create your sample list.
Then simply press run ...
... its that easy.
Increased throughput through parallel processing
System Overview
Cartridge Types 1, 3, 6 mL Cartridges
Air Push Modes Syringe or Gas Cylinder Valve
On-Bed Options Reservoirs, Four Probe Off Bed Solvent Transfer Port
Dimensions (w x d x h) 59.6 x 53.9 x 57 cm (23.5 x 21.25 x 22.46 in)
Cartridge Capacities* 108 – 1 mL cartridges 60 – 3 mL cartridges 24 – 6 mL cartridges*Assumes 3 tray positions used for SPE Mobile Racks.
608-836-1551 • 800-445-7661 • www.gilson.com
° Four probe Z-arm increases throughput and efficiency.
° On-bed reservoirs allow access of up to four solvents without taking up a position on the tray.
° On-bed transfer ports allow access to two additional large volume solvent reservoirs without taking up any on-bed rack positions. Extend this capability through the use of a VALVEMATE® II.
° Modular design allows the use of Code 146, 200, 34X and 37X Series racks.
° The 406 Dual Syringe Pumps are equipped with four independent pressure sensing modules that monitor pressure on each of the fluid
paths and can be used to handle error conditions such as high cartridge pressure or clogged liquid lines.
° Accommodates 1, 3 and 6 mL SPE cartridges.
° Mobile Rack technology enables use as both an SPE instrument as well as a liquid handling instrument.
° Positive Pressure elution ensures better reproducibility and higher precision.
The GX-274 ASPECTM is a high-throughput, four probe instrument
capable of processing up to four samples in parallel, increasing both the
throughput and effi ciency of your cartridge-based applications. Based
on Positive Pressure elutions this instrument processes samples with
Gilson’s innovative Sealing Cap technology, where each cartridge is
sealed, run and monitored individually. The two 406 Dual Syringe Pumps
allow the user to transfer liquids, process up to four samples in parallel
and monitor each fl uid path individually.
1 mL3 mL6 mL
Collection vessel access
Process four samples in parallel
GX-274 ASPEC TM
° Positive Pressure elution achieved via Gilson’s Sealing Cap technology.
° Eluted product can be fractionated by moving to different collection tubes.
° SPE process can be performed in either Batch or Sequential mode to increase throughput and efficiency.
VALVEMATE® II Valve Actuator
GX-274 ASPEC TM
with two 406 Dual Syringe Pumps
7 608-836-1551 • 800-445-7661 • www.gilson.com Solid Phase Extraction Solutions 8
SPE 215 System
What else can you do with
your Gilson SPE system?
Due to Gilson’s modular
design, you have the ability
to match your instrument
to your exact needs.
Peripherals such as
on-bed injectors,
on-bed solvent transfer
ports, on-bed rinse pumps
and on-board solvent
reservoirs allow you
to customize your
instrument to meet
your specifi c needs.
High-throughput Solid Phase Extraction and sample purifi cation
The SPE 215 System is an easy-to-use, powerful, sample
preparation solution for your laboratory. This instrument uses
Gilson’s Integrated Sealing Foot design to achieve Positive
Pressure elutions. Gilson’s multiple probe technology provides
the high throughput capability and the ability to increase
and improve your laboratory’s output and results. Dual Rail™
technology provides accurate and even pressure across all
eight syringes allowing for the selection of four or eight probes.
The integration of these technologies provides you with a
solid SPE solution and results in increased productivity and
effi ciency in your laboratory.
608-836-1551 • 800-445-7661 • www.gilson.com
System Overview
Cartridge Types 1, 3 mL Cartridges, 96-well extraction plate
Air Push Modes Syringe or Gas Cylinder from Solenoid Valve
On-bed Options Reservoirs, On-line Injection via 849 Multiple Injection Module
Dimensions (w x d x h) 97.8 x 61 x 64 cm (38.5 x 24 x 25.2 in)
Cartridge Capacities* 288 – 1 mL cartridges (tabless) 144 – 3 mL cartridges 3 – 96-well extraction plates*Assumes 3 tray positions used for SPE Mobile Racks.
° Mobile Rack technology enables use as both an SPE instrument as well as a liquid handling instrument.
° Accommodates 1 and 3 mL cartridges or 96-well extraction plates.
° Can be operated in both Batch and Sequential mode to increase throughput and efficiency.
° Four or eight probe configurations to increase throughput and efficiency.
° Positive Pressure ensures better reproducibility and higher precision.
° Positive Pressure achieved via Gilson’s Integrated Sealing Foot design for both cartridges and plates.
3 mL 1 mL 96-well extraction plates
SPE 215 with 849 Multiple Injection Module
SPE 215 Mobile RacksGilson’s Integrated Sealing Foot design
9 608-836-1551 • 800-445-7661 • www.gilson.com Solid Phase Extraction Solutions 10608-836-1551 • 800-445-7661 • www.gilson.com
TRILUTION® LH Software
Complete control for automated
Solid Phase Extraction (SPE)
applications.
Our latest software
package, TRILUTION® LH,
is Gilson’s most
easy-to-use and most
powerful SPE and liquid
handling software yet.
Designed with the user
in mind, the software
is extremely fl exible
allowing you to focus
on the science rather
than the software.
The complete software solution for your Liquid Handling and SPE applications
This intuitive software offers
easy-to-use capabilities for the
every day user.
° User-friendly graphical interfaceminimizes the learning curve while maximizing efficiency.
° One software package to control all liquid handling and SPE instruments maximizes the utility of the hardware.
° Drag-and-drop functionality enables you to quickly and easily set up instrument configurations and define bed layouts.
° The Application Run screen provides complete control over your run; from set up to application run, to simulation and the modification of your run.
° Import/Export functionality allows you to transfer methods from one system to another quickly and easily.
° Over 70 Gilson-supplied tasks make programming methods and creating applications quick and easy.
Wait TaskTips Rinse Task
Mix With Tips Task
SPE Evaporate
Task
SPE Wash Task
SPE Load Task
Dispense Random
Task
Derivatize Task
Add Task
SPE Elute Task
SPE Dry TaskSPE Condition
Task
° Sample list editor makes building your application easier than ever with spreadsheet data entry and functionalities such as copy down and increment.
° Graphical task pages organize data entry, allowing the user to quickly create and modify task properties.
° Simulation mode allows the user to test and verify methods and applications prior to running the instrument.
° Dynamic, graphical property pages ensure quick and easy data entry and variable creation, while eliminating the need to create long variable lists giving you the ultimate flexibility with minimal effort.
° Manual Control pages allow you to perform routine tasks, troubleshoot the instrument and set up the instrument prior to running your applications.
Simulation in Application Run screen
Method in Method BuilderM h d i M h d B ild
Bed Layout in Method Builder
SS Dispense Task property page
GX-271 Manual Control page
Custom Task Builder
ProcessorIntel® Pentium® 4 (2.8 GHz)
Fixed Drive80 GB, Available space: 4 GB (6 GB at install)
Computer RecommendationsVideo Card1024 x 768 with 24 bit True Color
RAM1 GB
Additional DriveDVD/CD-RW
Serial Ports 2
Operating SystemMicrosoft® Windows® XP Professional SP2 or later, Microsoft® Windows® 2000 SP4
Microsoft, Windows, Word, and Excel are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries
11 608-836-1551 • 800-445-7661 • www.gilson.com Solid Phase Extraction Solutions 12
Whether looking for high-
throughput, pre-injection clean-
up or simple sample prep before
injection, users can customize
their Gilson-based systems with
the Code 300 Series Mobile Racks.
The robustness of Gilson’s liquid
handlers when combined with
Mobile Rack technology provides
a customized solution for any of
their SPE/purifi cation needs.
Code 300 Series Racks
The Code 300 Series Racks now allow virtually all of Gilson’s existing
instruments to perform SPE, fi ltration and liquid handling tasks.
Combine all the features and functionality of Gilson’s liquid handlers
and the time tested Mobile Rack technology to customize your
instrument to your specifi c application needs.
° The Code 300 racks accommodate 1, 3 and 6 mL cartridges.
° The Code 300 Series Racks can be used on any Gilson instrument that accommodates a Code 200 Series Rack, effectively transforming automated liquid handling instruments into solid phase extraction systems.
° Compatible with single probe, multiple probe or spannable multiple probe instruments.
SPE Process
Analyte Interferences
Conditioning Loading Sample Washing Eluting
traction Solutionsxtraction Solutions
Extend the capabilities of your Liquid Handling instrument
Why automate SPE?
Automating SPE increases throughput
and improves reproducibility, while
minimizing the exposure to harmful
chemicals. Gilson’s instruments are
designed to be workhorse instruments
that can be set up quickly. The
application can be started while the
researcher works on other tasks and
the instrument will fi nish effortlessly.
This minimizes the cost of labor
typically associated with manual
SPE processes, and allows SPE to
be performed without a researcher
present. With single, four probe and
eight probe parallel processing units,
you decide which instrument provides
the throughput needed for your
application.
Code 306 and 301 Racks
System Overview
Cartridge Types 1, 3 and 6 mL Cartridges.
Instrument All instruments capable of using Code 200 Series RacksCompatibility
Rack Code 300 Rack Code 300: 1 mL cartridge w/ 96-well deep microplate collectionOptions Rack Code 301: 1 mL cartridge w/ 96-well shallow microplate collection Rack Code 302: 1 mL cartridge w/ 48 12x32 mm vials (2 mL) Rack Code 303: 3 mL cartridge w/ 48 12x32 mm vials (2 mL) Rack Code 304: 3 mL cartridge w/ 48 12x75 mm tubes (5 mL) Rack Code 305: 3 mL cartridge w/ 32 15x45 mm vials (4 mL) Rack Code 306: 6 mL cartridge w/ 20 12x75 mm tubes (5 mL) Rack Code 307: 6 mL cartridge w/ 20 15x45 mm vials (4 mL)
GX-271ASPEC
GX-274ASPEC
SPE215
Gilson’s Automated SPE SolutionsDesigned to Run Unattended
(20+ hours / day)
SPE Samples Processed per Day(Assuming a 10 min run time)
Sam
ple
s P
rocessed
480
960
120
Gilson, Inc. World Headquarters | 3000 Parmenter Street | P.O. Box 620027 | Middleton, WI 53562-0027, USA | Tel: 608-836-1551 or 800-445-7661 | Fax: 608-831-4451
Gilson S.A.S. | 19, avenue des Entrepreneurs | BP 145, F-95400 VILLIERS LE BEL, FRANCE
www.gilson.com | [email protected] | [email protected] | [email protected]
©2008 Gilson, Inc. | LT303017-05 | Printed in the USA. | Specifications subject to change without notice.
SPE_Cover.indd 1 11/7/2008 1:46:39 PM