source strength source strength removal rate removal rate ventilation and iaq

52
Source Strength Removal Rate Ventilation and IAQ

Upload: darrell-blake-reynolds

Post on 27-Dec-2015

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

SourceStrengthSource

Strength RemovalRate

RemovalRate

Ventilation and IAQ

Page 2: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Random air leaks do not provide effective fresh air through a home

Depends on temperature difference, wind, exhaust

Page 3: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Random air leaks do not provide effective fresh air through a home

Where are the holes?

Page 4: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Random air leaks do not provide effective fresh air through a home

Where are the holes?

Page 5: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Random air leaks do not provide effective fresh air through home

Where are the holes?

Page 6: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Random air leaks do not provide effective fresh air through home

Where are the holes?

Page 7: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Ventilation Basics

How does ventilation work ?

How much ventilation do I need in my climate ?

Page 8: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Ventilation is not a cure-allLimit and control pollutants at the source

carbon monoxide asthma triggers moisture allergens particles radon VOCs chemicals

etc. etc. etc.

Page 9: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Limit moisture sources

Cook with lids

Keep bathroom doors closed until moisture is removed

No indoor clothes lines

Limit indoor plants

Page 10: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Capture & Remove moisture at source:ShowersCookingLaundry

Page 11: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Ventilation Examples1,500 Sq Ft House70 degrees indoor air temperature85% outdoor relative humidity

Let’s look at what happens at …1. 30 degrees outdoor temp ?2. 50 degrees outdoor temp ?3. What happens if we double the indoor moisture load?

Page 12: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Ventilation (Air Changes Per Hour) VS

Indoor Relative Humidity (%)

0

20

40

60

80

100

0.1 0.3 0.5 0.7 0.9 1.1 1.3 1.6 1.7 1.9

I

nd

oor

Rel a

tive H

um

i dit

y

( %)

1,500 ft sq house700 F indoor temp85 % outdoor RH

300 F outside temp typical moisture load

.35 AC/h

based on G. Tsongas

l l .35 l l l l l l l l l l l l l

Ventilation: Air Changes per Hour (AC/h)

Extreme Ventilation Makes Little Difference

Page 13: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Ventilation (Air Changes per hour) VS

Indoor Relative Humidity (%)

0

20

40

60

80

100

I

nd

oor

Rel a

tive H

um

i dit

y

(%)

1,500 ft sq house700 F indoor temp85 % outdoor RH

500 F outside temp typical moisture load

.35 AC/h

based on G. Tsongas

l l .35 l l l l l l l l l l l l Ventilation: Air Changes per Hour (AC/h)

Page 14: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Ventilation (Air Changes Per Hour) VS

Indoor Relative Humidity (%)

0

20

40

60

80

100

I

nd

oor

Rel a

tive H

um

i dit

y

( %)

1,500 ft sq house700 F indoor temp85 % outdoor RH

300 F outside temp typical moisture load 2 X moisture load

500 F outside temp typical moisture load 2 X moisture load

.35 AC/h

based on G. Tsongas

l l .35 l l l l l l l l l l l l l Ventilation: Air Changes per Hour (AC/h)

Page 15: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Drying Potential of Outside Air:

The colder the outside air, the more drying effect when this air

is warmed inside

Warm, humid air has much less drying potential

(can cause problems)

Page 16: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Good News for Energy & Comfort

When it’s cold outside: need less air exchange

When it’s mild outside: need more exchange

Page 17: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Exhaust Moisture at the Source

Page 18: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Fan & Light Switch

Fan delay time1 to 60 minutes

Page 19: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

If double pane windows are getting foggy on the room side, condensation

& mold growth are on the way…

Page 20: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Comfort, Moisture, Noise, Pollen, Dust, Odors, Security

Open Windows for Ventilation?

Page 21: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Ventilation Systems

1. Central Exhaust2. Multi-port Exhaust3. Heat Recovery Ventilator

(balanced)

Page 22: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Dry air in

Exhaust Fan

Dry air in

Wet air out

Central Exhaust

Page 23: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Manual and Automatic Controls

Page 24: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Should operate 24 hours per day

Page 25: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

2 Speed Whole House Fresh Air Fan Low speed 24/7 continuous fresh air

High speed for odors moisture VOCs particles etc.

Fan off delay timer

Super Quiet

Page 26: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Motion Sensor turns fan to high speed

24/7 Low Speed CFM Setting

Fan off delay timer

Page 27: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

24/7 Low Speed CFM Setting

Fan off delay timer

Page 28: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ
Page 29: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Air Inlets Built Into Window Frame

Page 30: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Through-the-Wall Fresh Air Vent

Page 31: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Ventilation Systems

• Central Exhaust• Multi-port Exhaust• Heat Recovery Ventilator (balanced)

Page 32: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Air out thru roof

Air out from rooms in home

Exhaust fan in Box

Unit suspendedin attic

Page 33: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ
Page 34: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ
Page 35: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ
Page 36: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Bedro

om

Cen

tral

Zo

ne

Bathroom

Bedro

om

Page 37: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Bathroom exhaust grill

about 20 CFMContinuous

65 -80 CFMHigh Speed

Page 38: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Bedroom exhaust grill

about 10 CFMeach room continuous

Page 39: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Ventilation Systems

• Central Exhaust• Multi-port Exhaust• Heat Recovery Ventilator (balanced)

Page 40: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ
Page 41: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Heat Recovery Ventilation

Stale Moist Exhaust From

House

TemperedFresh Air

Into House

OutsideFresh Airto House

Stale HouseAir Exhaust

Page 42: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Outside Air

Supply Air

Return Air

Exhaust Air

Defrost Damper

Page 43: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ
Page 44: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Airborne Mold Sampling

EPA, ACGIH* and other peer reviewed guidelines do not recommend airborne mold sampling as part of an investigation or remediation…

*American Congress of Governmental Industrial Hygienists

Page 45: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

It is very unlikely that airborne mold samples will provide evidence

that cannot be more easily and reliably obtained by

a thorough inspection

Airborne Mold Sampling

Page 46: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Airborne Sampling can produce False Negatives . . but not False Positives

“Absence of Evidence is NOT Evidence of Absence”

Page 47: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Consensus is that traditional methods used to identify increased mold

exposure do not reliably predict increased health risks.

California Department of Public Health Statement on Building Dampness, Mold, and Health, September 2011

Page 48: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

Current practices for collection, analysis, and interpretation of environmental samples for mold…

cannot be used to quantify health risks posed by dampness and mold in buildings or to guide health-based actions.

California Department of Public Health Statement on Building Dampness, Mold, and Health, September 2011

Page 49: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

California Department of Public Health Statement on Building Dampness, Mold, and Health, September 2011

Current consensus does not justify the differentiation of some molds (such as Stachybotrys species) as “toxic molds”

Page 50: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

California Department of Public Health Statement on Building Dampness, Mold, and Health, September 2011

The only types of evidence that have been related consistently to adverse health effects are:

current or past water damage, damp materials, visible mold, mold odor.

But not the number or type of mold spores nor the presence of other markers of mold in indoor air or dust.

Page 51: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

The most effective tool for locating mold growth and building dampness: a detailed site inspection,

understanding moisture dynamics,

building science fundamentals.

(Light, 2009)

Page 52: Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ

One set of investigations based on detailed building inspection, Parallel investigations based on mold testing.

Results indicated that extensive collection of air and surface samples failed to identify mold growth in addition to that observed using visual indicators.

Moreover, the inspector using visual cues located hidden mold growth undetected by sampling in half of the cases (6 of 12).

(Light, 2009)

12 cases where opposing experts evaluated the same water damaged site: