WiFi Ready Mute Operation Silver ion Filter Anti Cold Air Sleep Mode Cold Catalyst Filter 12 Grades Indoor Fan Speeds Self Diagnosis Function Two-way Draining Connection Indoor and Outdoor Anticorrosive Coating GoldFin Double Level Air Flaps High Density Filter Turbo Operation Refrigerant Leakege Detect GENERAL FEATURES SOPHIA WALL-MOUNTED SERIES SPLIT AIR CONDITIONER WITH HEAT PUMP Submittal Data Sheet CH-SR09SPH-115VI (INDOOR UNIT) CH-SR09SPH-115VO (OUTDOOR UNIT) INDOOR SPECIFICATION OUTDOOR SPECIFICATION Sound Preassure level Refrigerant type Refrigerant precharge Additional charge for each ft Job Name:_________________________________________________________________________ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ : n o i t a c o L Engineer:______________________________________________________________________ Submitted to:_____________________________________________________________________ Submitted by:_____________________________________________________________________ Reference:_________________________________________________________________________ Date:______________________________________________________________________________ Approval:__________________________________________________________________________ Unit #:_____________________________________________________________________________ Drawing #:_________________________________________________________________________ This warranty should be registered on our the web-site www.cooperandhunter.us The warranty is only valid when installed by a Licensed HVAC Technician. A war- Warranty applies only to products remaining in their original installation location. EFFICIENCY Cooling Heating SEER 25 15 10.5/8.6 4.10 HSPF4/HSPF5 EER COP SYSTEM PERFORMANCE 9,000 Btu/h 600 W 5.2 A Cooling Capacity Input Rated current 10,000 Btu/h 715 W 6.22 A Heating Capacity Input Rated current OPERATION TEMPERATURE RANGE Indoor Outdoor cooling heating cooling heating o F 32 – 86 o F -13 – 122 o F -13 – 86 o F ELECTRICAL Power supply MCA MFA 20 A 15 A Compressor Type ROTARY 1/4” - 1/2” in 115V / 60Hz,1Ph MCA: Minimum Circuit Ampacity; MFA: PIPING 82 ft 33 ft WIRING Connection wiring Power supply wiring SUPERIOR SEER 25 306/212/147 CFM 36/32/23 dB(A) 31.57x7.44x11.69 in 18.7/24.3 Lbs 1120 CFM 52.5 dB(A) 31.50x13.11x21.81 in R410A/40.6 25 ft 0.16 oz 82.7/89.2 Lbs

Upload: others

Post on 06-Aug-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SOPHIA - cooperandhunter.us · SOPHIA WALL-MOUNTED SERIES SPLIT AIR CONDITIONER WITH HEAT PUMP Submittal Data Sheet CH-SR09SPH-115V I (INDOOR UNIT) CH-SR09SPH-115VO (OUTDOOR UNIT)

• WiFi Ready• Mute Operation• Silver ion Filter• Anti Cold Air• Sleep Mode• Cold Catalyst Filter• 12 Grades Indoor Fan Speeds• Self Diagnosis Function

• Two-way Draining Connection• Indoor and Outdoor

Anticorrosive Coating GoldFin• • Double Level Air Flaps • High Density Filter • Turbo Operation• Refrigerant Leakege Detect

GENERAL FEATURES

SOPHIAWALL-MOUNTED SERIES

SPLIT AIR CONDITIONER WITH HEAT PUMP

Submittal Data Sheet CH-SR09SPH-115VI (INDOOR UNIT)

CH-SR09SPH-115VO (OUTDOOR UNIT)

INDOOR SPECIFICATION

OUTDOOR SPECIFICATION

Sound Preassure level

Refrigerant typeRefrigerant prechargeAdditional charge for each ft

Job Name:_________________________________________________________________________ ________________________________________________________________________:noitacoL

Engineer:______________________________________________________________________ Submitted to:_____________________________________________________________________ Submitted by:_____________________________________________________________________Reference:_________________________________________________________________________

Date:______________________________________________________________________________Approval:__________________________________________________________________________

Unit #:_____________________________________________________________________________Drawing #:_________________________________________________________________________

This warranty should be registered on our the web-site www.cooperandhunter.us

The warranty is only valid when installed by a Licensed HVAC Technician. A war-

Warranty applies only to products remaining in their original installation location.

EFFICIENCYCooling Heating

SEER 2515

10.5/8.64.10

HSPF4/HSPF5EER COP

SYSTEM PERFORMANCE

9,000 Btu/h600 W5.2 A

Cooling Capacity

InputRated current

10,000 Btu/h715 W6.22 A

Heating Capacity

InputRated current

OPERATION TEMPERATURE RANGEIndoor Outdoor

cooling heating cooling heatingoF 32 – 86 oF -13 – 122 oF -13 – 86 oF

ELECTRICALPower supply

MCAMFA 20 A

15 A

Compressor Type ROTARY

1/4” - 1/2” in

115V / 60Hz,1Ph

MCA: Minimum Circuit Ampacity; MFA:

PIPING

82 ft33 ft

WIRINGConnection wiring Power supply wiring

SUPERIOR SEER 25

306/212/147 CFM36/32/23 dB(A)

31.57x7.44x11.69 in18.7/24.3 Lbs

1120 CFM52.5 dB(A)

31.50x13.11x21.81 in

R410A/40.625 ft

0.16 oz

82.7/89.2 Lbs

Page 2: SOPHIA - cooperandhunter.us · SOPHIA WALL-MOUNTED SERIES SPLIT AIR CONDITIONER WITH HEAT PUMP Submittal Data Sheet CH-SR09SPH-115V I (INDOOR UNIT) CH-SR09SPH-115VO (OUTDOOR UNIT)

INDOOR UNIT CH-SR09SPH-115VI

OUTDOOR UNIT CH-SR09SPH-115VO

W D H

31.57 7.44 11.69

OUTDOOR UNIT DIMENSIONS (in)W x H x D

31.50” x 21.81” x 13.11”

W

WALL-MOUNTED SERIESSPLIT AIR CONDITIONER WITH HEAT PUMP

SOPHIASUPERIOR SEER 25