some aspects of indoor air pollution 2013

19
Some aspects of indoor air pollution Zoltán Filep WESSLING Hungary Ltd.

Upload: filepz

Post on 26-Oct-2015

22 views

Category:

Documents


2 download

DESCRIPTION

Some aspects of indoor air pollution

TRANSCRIPT

Page 1: Some aspects of indoor air pollution 2013

Some aspects of indoor air pollution

Zoltán Filep

WESSLING Hungary Ltd.

Page 2: Some aspects of indoor air pollution 2013
Page 3: Some aspects of indoor air pollution 2013
Page 4: Some aspects of indoor air pollution 2013

Molds

Page 5: Some aspects of indoor air pollution 2013

...and some more …

Page 6: Some aspects of indoor air pollution 2013
Page 7: Some aspects of indoor air pollution 2013

Certification of emission of building products

voluntary,

controlled production,

assesment of builiding

products:

basics of materials,

emissions,

different testing schemes

different criteria

Page 8: Some aspects of indoor air pollution 2013
Page 9: Some aspects of indoor air pollution 2013

ANNEX I

Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products

3. Hygiene, health and the environment

The construction work must be designed and built in such a way that it will not be a

threat to the hygiene or health of the occupants or neighbours, in particular as a

result of any of the following:

- the giving-off of toxic gas,

- the presence of dangerous particles or gases in the air,

- the emission of dangerous radiation,

- pollution or poisoning of the water or soil,

- faulty elimination of waste water, smoke, solid or liquid wastes,

- the Presence of damp in parts of the works or on surfaces within the works

Page 10: Some aspects of indoor air pollution 2013
Page 11: Some aspects of indoor air pollution 2013
Page 12: Some aspects of indoor air pollution 2013

ISO 16000-1:2004 Indoor air -- Part 1: General aspects of sampling strategy

ISO 16000-2: Indoor air -- Part 2: Sampling strategy for formaldehyde

ISO 16000-3:2001 Indoor air -- Part 3: Determination of formaldehyde and other carbonyl compounds --

Active sampling method

ISO 16000-4:2004 Indoor air -- Part 4: Determination of formaldehyde -- Diffusive sampling method

ISO 16000-5:2007 Indoor air -- Part 5: Sampling strategy for volatile organic compounds (VOCs)

ISO 16000-6:2004 Indoor air -- Part 6: Determination of volatile organic compounds in indoor and test

chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography

using MS/FID

ISO 16000-7:2007 Indoor air -- Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations

ISO 16000-9:2006 Indoor air -- Part 9: Determination of the emission of volatile organic compounds from building products and

furnishing -- Emission test chamber method

ISO 16000-10:2006 Indoor air -- Part 10: Determination of the emission of volatile organic compounds from building products and

furnishing -- Emission test cell method

ISO 16000-11:2006 Indoor air -- Part 11: Determination of the emission of volatile organic compounds from building products and

furnishing -- Sampling, storage of samples and preparation of test specimens

International standards for indoor air analysis

Page 13: Some aspects of indoor air pollution 2013

Sampling strategies for indoor air (ISO 16000-5)

Aims of sampling:

finding the causes of health problems

determination of long term exposure,

identification of emission sources,

assessment of remediation.

Parameters to consider:

sampling time,

sampling place,

sampling duration,

choice of sorbents.

Page 14: Some aspects of indoor air pollution 2013

Classification of air pollutants

Name Abbreviations Boiling point range (°C)

Very Volatile Organic Compounds VVOC <0- (50-100)

Volatile Organic Compounds VOC (50-100)-(240-260)

Semi-Volatile Organic Compounds SVOC (240-260)-(380-400)

Particulate Organic Matter POM >380

Page 15: Some aspects of indoor air pollution 2013

„Décret no 2012-14 du 5 janvier 2012 relatif à l’évaluation des moyens d’aération et à la mesure des polluants effectuées au titre de la surveillance de la qualité de l’air intérieur de certains établissements recevant du public”

French regulation

passive sampling for benzene and formaldehyde

TD-GC/MS analysis for benzene,

HPLC for formaldeyhde

Page 16: Some aspects of indoor air pollution 2013

Method Target compounds Standard Sampling time

QL

Volatile organic compounds with TD/GC-MS (active sampling) (C6-C16)

Hydrocarbons, terpenes, alcohols, ethers, ketones, aldehydes, glycols, glycol-ethers, carboxylic acids, halogenated hydrocarbons

ISO 16000-6 1 hour 5 ng/sample

Volatile organic compounds with TD/GC-MS (passive sampling) (C6-C16)

Hydrocarbons, terpenes, alcohols, ethers, ketones, aldehydes, glycols, glycol-ethers, halogenated hydrocarbons

ISO 16017-2 8 hours/ 168 hours

5 ng/sample

Volatile organic compounds with GC-MS (passive sampling on charcoal)

Hydrocarbons, terpenes, alcohols, ethers, ketones, aldehydes, glycols, glycol-ethers, halogenated hydrocarbons

ISO 16200-2 1-2 weeks 5 µg/sample

Available method at Environmental Testing Laboratory

Page 17: Some aspects of indoor air pollution 2013

Method Target compounds Standard Sampling time

QL

Formaldehyde and aliphatic aldehydes (active sampling)

formaldehyde, acetaldehyde, butanal, isobutanal, propanal

ISO 16000-3 30 min-480 min

2 µg/sample

Formaldehyde (passive sampling)

formaldehyde ISO 16000-4 8 hours- 168 hours

2 µg/sample

Phthalates (active sampling)

Dimethyl-phthalate, diethyl-phthalates, di-n-butyl-phthalate, benzyl-butyl-phthalate, dicyclohexyl-phthalate, bis(2-ethyl-hexyl)-phthalate, di-n-octíl-phthalate

VDI 4301-6 1-8 hours 10 ng/sample

Available method at Environmental Testing Laboratory

Page 18: Some aspects of indoor air pollution 2013

Quality assurance for TD-GC/MS analysis:

participation in round robin tests (interlaboratory comparison)

proper conditioning of tubes,

logbook for each tube,

blanks:

laboratory blank,

field blank,

trip blank.

Page 19: Some aspects of indoor air pollution 2013

Thank you for your attention!