![Page 1: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/1.jpg)
Solutions for Single Spaces Energi TriPak™
![Page 2: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/2.jpg)
Learning Objectives
1. To understand lighting control strategies
2. To understand what the Energi TriPak family is
3. To understand what problems the Energi TriPak can solve for our customers
4. To recognize the products that make up the Energi TriPak
5. To apply Energi TriPak products to an assortment of application
![Page 3: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/3.jpg)
Lighting Control Strategies
• Dimming
• High-End Tuning
• Occupancy / Vacancy Sensing
• Daylight Harvesting
• Personal Dimming Control
• Scheduling
• Controllable Window Treatments
• Load Shedding
• Plug Load Control
• System Integration
10 Energy Saving Lighting Control Strategies
![Page 4: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/4.jpg)
Lighting Control Strategies
• Dimming
• High-End Tuning
• Occupancy / Vacancy Sensing
• Daylight Harvesting
•Personal Dimming Control
• Scheduling
• Controllable Window Treatments
• Load Shedding
• Plug Load Control
• System Integration
10 Energy Saving Lighting Control Strategies
When used together these strategies have created saving opportunities greater than 70% lighting energy
savings and regularly achieve savings greater than 60%.1
![Page 5: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/5.jpg)
Lighting Control Strategies 7 Strategies the Energi TriPak supports
• Dimming
• High-End Tuning
• Occupancy / Vacancy Sensing
• Daylight Harvesting
•Personal Dimming Control
• Scheduling
• Controllable Window Treatments
• Load Shedding
• Plug Load Control
• System Integration
![Page 6: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/6.jpg)
Dimming
• Allows the “perfect” level light as well as either empowers or improves all the other lighting control strategies.
Typical Lighting Energy Savings:
See Other Strategies
![Page 7: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/7.jpg)
High-End Tuning
• Set the maximum light level in a space based on customer preference or design requirements
• Field Adjustable
Typical Lighting Energy Savings: 10-20%2
![Page 8: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/8.jpg)
Occupancy/Vacancy Sensing
• Gradually dim lights to a low level or turn lights Off when space is unoccupied
• Occupancy Sensing • Auto-On/Auto-Off
• Vacancy Sensing • Manual-On/Auto-Off
Typical Lighting Energy Savings: 20-60%3
![Page 9: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/9.jpg)
Daylight Harvesting
• Dim electric light or switch it off during the day to take advantage of available sunlight. Two styles of daylighting:
• Switching (/Bi-Level/Step-Dim) • Continuous Dimming
Typical Lighting Energy Savings: 20-60%4
![Page 10: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/10.jpg)
Personal Dimming Control
• Provide personal choice and control of light levels to accommodate the different task and activities in an area. • Allow different occupant to adjust light levels in they work space to the “perfect” light level for their eyes and the task at hand. • Permit control from multiple locations.
Typical Lighting Energy Savings: 20-60%5
![Page 11: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/11.jpg)
Scheduling
• Provides scheduled changes to the building system based on time of day
• Lights: On/Preset/Off • Shades: Open/Preset/Close • Sensors: Enable/Disable • Controls: Enable/Disable
• More than just Sweep On/Sweep Off
Typical Lighting Energy Savings: Variable6
![Page 12: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/12.jpg)
Controllable Window Treatment
• Motorized shades allow for quiet, automatic and manual control of window treatment in order to reduce glare and solar heat gain
• Effects the energy usage of both Lighting and HVAC systems
Typical Lighting Energy Savings: Variable7
![Page 13: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/13.jpg)
Load Shedding
• Automatically reduces lighting loads during peak electricity usages times. There are two types of load shedding:
• Demand Response • Peak Load Management
Typical Lighting Energy Savings: Variable
![Page 14: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/14.jpg)
Plug Load Control
• Automatically turns off loads after occupants leave a space. There are two styles of plug load control:
• Receptacle Circuit Control • Plug-In Control
Typical Plug Load Energy Savings: 10-15%8
![Page 15: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/15.jpg)
Integration
• Share information across systems or platforms.
• Contact Closure • RS232/Ethernet • BACnet IP
Variable Typical HVAC Energy Savings:
![Page 16: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/16.jpg)
Single Space Solutions
The Energi TriPak Family of Products
![Page 17: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/17.jpg)
The Energi TriPak Three categories of devices
![Page 18: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/18.jpg)
Energi TriPak – “Sense”
The “Sense” aspect of the Energi TriPak is made up of the Radio Powr Savr™ family of sensors: • Wireless Occupancy Sensors
• Ceiling-Mount • Wall-Mount • Corner-Mount • Hallway-Mount
• Daylight Sensors • Ceiling-Mount
These devices contain a battery with an estimated 10 year life and are designed to be quickly and easily placed, without the need to pull conduit or cable.
Transmitting Device
![Page 19: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/19.jpg)
Energi TriPak – “Adjust”
The “Adjust” portion of the Energi TriPak is made up of the PICO™ family of remote controls: • Wireless Remote Controls
• Hand-Held • Wall-Mount • Pedestal-Mount
• Keypad Configurations such as: • 2-Button w/ and w/o Raise/Lower • 3-Button w/ and w/o Raise/Lower
These devices contain a battery with an estimated 10 year life and are designed to be quickly and easily placed, without the need to pull conduit or cable.
Transmitting Device
![Page 20: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/20.jpg)
Energi TriPak – “Conserve”
The “Conserve” products of the Energi TriPak consist of load controllers and they come is various form factors: • PowPak
• Dimming PowPak w/ EcoSystem™ • SoftSwitch PowPak • SoftSwitch PowPak w/ Contact Closure Output
• Stairwell Fixture and Stairwell Fixture Kits • Plug-In Appliance and Dimming Module • Maestro Wireless Wall Switches and Dimmers
• Various dimming styles available •Maestro Wireless Tabletop Lamp Dimmer
The Conserve products are all wireless receivers and draw power from a wired connection
Receiving Devices
![Page 21: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/21.jpg)
Maestro Wireless • Simple retrofit of existing wallbox switches and/or dimmers • 120V/227V, no neutral required versions • Compatible with multiple location companion switches for simple 3-way • INC/HAL/MLV/ELV/3F/SW • Advance Programming Mode
Dimmer Switch
![Page 22: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/22.jpg)
Stairwell Solutions
• Radio Powr Savr Occupancy Sensor communicates with the integral wireless dimmer installed in the fixture • Automatic jumps from high-end to low-end light levels, and vice versa, occupants enter and leaving stairwell • Field adjustable high-end and low-end light levels
Unoccupied: 20% light level Occupied: 80% light level
![Page 23: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/23.jpg)
Plug-In Modules
15A Switching Module 300W Dimming Module
• Switches plug loads off when not in use through manual and/or automatic controls • Use with task lighting, monitors, printers, and personal heaters • Easy plug-in installation, no tools required • Simple button press programming
PowPak Plug-In Appliance Module
![Page 24: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/24.jpg)
PowPak Modules
PowPak CCO Module PowPak Dimming Module with EcoSystem
PowPak Relay Module with SoftSwitch
Occupied Unoccupied
• Great in all applications • Provides local integration to VAV and other local 3rd party systems • Cost competitive digital dimming • Advanced Lighting Control with 7 of the 10 strategies • Contractor or End-User start-up possible
![Page 25: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/25.jpg)
Energi TriPak Solution
• Dimming
• High-End Tuning
• Occupancy / Vacancy Sensing
• Daylight Harvesting
•Personal Dimming Control
• Plug Load Control
• System Integration
System Limits & Strategies
System Limitations • Single Space Solution • Create a solution using one or multiple conserve products and link with:
• up to 1 RF Daylight Sensor • up to 6 RF Occupancy Sensors • up to 9 RF PICO Remotes
• Up to a max of 10 RF Devices
![Page 26: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/26.jpg)
Benefits of Energi TriPak • Easy to install and program
– All devices use wireless communication, reducing wiring labor and materials
– Default functionality fits many applications – Simple button-press programming, no commissioning
required
• Cost Effective – Energi TriPak saves Installation Time... Saves Money! – Energi TriPak saves Materials… Saves Money! – Energi TriPak saves Energy… Saves Money!
![Page 27: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/27.jpg)
Energi TriPak - Technologies There are four core technologies at work in
the Energi TriPak family of products: • Clear Connect™ RF Communication • Lutron Extended Battery Life • XCT™ Passive Infrared Occupant Sensing • EcoSystem™ Digital Lighting System
![Page 28: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/28.jpg)
Clear Connect™ RF Communication
Clear Connect™ RF • Clear Connect RF technology uses a low-power, non-licensed
frequency band as defined by FCC Title 47 Part 15.231. Operating at Lutron’s chosen frequency of 434MHz helps ensure that no other devices interfere with Lutron’s wireless communications.9
– Frequency Band: 410-470MHz – Uses: Intermittent Control Signals – Emission Limits: Low-Power (125/3) x f(MHz) – 21250/3 µV/m @ 3m
• For comparison, this table three well known wireless bands. Frequency Band Type of Use Emission Limit 47 CFR
410-470MHz Intermittent or Event Driven 21250µV/m 12.231
902-928MHz Spread Spectrum 1W 15.247 2.4-2.435GHz Spread Spectrum 1W 15.247
![Page 29: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/29.jpg)
Clear Connect™ RF Communication
Clear Connect RF • Clear Connect RF technology is a restricted, radio frequency band
that all Lutron wireless products use to communicate. This ensures no other devices interfere with Lutron’s lighting system.
2.4 - 5.0 GHz: • Telephones • Wi-Fi Networks • Bluetooth Devices • Wireless Security Cameras
434 MHz: • Lutron Clear Connect RF technology devices • 30ft thru construction materials • 60ft line-of-sight (100ft for PICO)
In low traffic, restricted frequency band ensures flawless communication.
In crowded frequency bands there is a high potential for RF interference.
![Page 30: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/30.jpg)
Clear Connect™ RF Communication
• Fixed Networks • Dedicated sending, receiving, and computing stations provide RF coverage • Messages move through the network in a predetermined manner producing short delivery times • Location of source and destination device do not affect performance •Cares an RF backbone
• Mesh Networks • System devices form a “matrix” of possible message delivery routes • Messages can be relayed through any system device • Routing tables determine the path from source to destination • Assuming enough system devices, no repeaters are required (potentially lower cost)
Two common RF network architectures:
![Page 31: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/31.jpg)
Lutron Extended Battery Life
• 3rd party verify 10 year battery life • See “Estimating the Battery Life of an Occupancy Sensor” report
• Readily available batteries
CR2032 CR123A CR2450
![Page 32: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/32.jpg)
XCT™ Passive Infrared Occupant Sensing
Lutron Maestro In-Wall Occupancy Sensor with XCT™
In accordance with NEMA testing standards, Lutron performed minor-motion coverage testing on the Maestro PIR occupancy sensor with XCT technology, and on four additional PIR occupancy sensors manufactured by others. The graphs clearly demonstrate that sensors with XCT technology have the superior ability to detect minor motion.
• sensor (Maestro In-Wall Sensor) • greater than 75% detection rate • 50% to 75% detection rate • less than 50% detection rate
Company 1 Occupancy Sensor Company 2 Occupancy Sensor
Company 3 Occupancy Sensor Company 4 Occupancy Sensor
![Page 33: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/33.jpg)
EcoSystem™ Digital Lighting System
Dimming Zone 1
Dimming Zone 2
• EcoSystem cabling is topology and polarity free.
• Power all EcoDevices using line voltage and connect using E1/E2 low-voltage link; Class 1 or Class 2
• Uses same wiring as a 0-10V ballast
![Page 34: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/34.jpg)
EcoSystem™ Digital Lighting System
Dimming Zone 1
Dimming Zone 2
• Occupancy Area is created that includes all fixtures in the classroom
• Occupancy settings are adjusted for each area
• The occupied and unoccupied scene can be selected
![Page 35: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/35.jpg)
Dimming Zone 1
Dimming Zone 2
• PC Zones are created within the area
• PC Zones are fixtures that will always be controlled together (like a switch-leg)
• Pico wireless controls can be configured to control zones or recall a scene
• Pico can affect multiple zones or multiple areas
EcoSystem™ Digital Lighting System
![Page 36: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/36.jpg)
Dimming Zone 1
Dimming Zone 2
• Daylight rows are created within the area
• Daylight rows can overlap zones in EcoSystem
•2 Daylight rows available with EcoSystem PowPak
• Field adjustable target light levels
Daylight Row 1
Daylight Row 2
Daylight Row 2
EcoSystem™ Digital Lighting System
![Page 37: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/37.jpg)
Application: Restroom
• Design Goals: – No local control on the wall to prevent accidently
turning off the lights when occupied – Automatic shutoff of lights when the room is empty
![Page 38: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/38.jpg)
Application: Restroom
• PowPak Relay installs in the ceiling and switches the lighting in the restroom
• Mix of corner mount and ceiling mount sensors to ensure coverage throughout
![Page 39: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/39.jpg)
Application: Private Office
• Design Goals: – Personal control – Automatic shutoff of lights when the room is empty – Daylight harvesting – Task lighting control – Appliance Control
![Page 40: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/40.jpg)
Application: Private Office
• Maestro Wireless switch easily replaces existing wall switch • PowPak plug-in appliance module and MRF tabletop dimmer control plug loads • One RPS occupancy sensor communicates with all load controllers
![Page 41: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/41.jpg)
Application: Classroom
• Design Goals: – Multiple zones of control – Daylight harvesting – Automatic shutoff of lighting
![Page 42: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/42.jpg)
Application: Classroom
• EcoSystem wiring is connected to every ballast • Digital technology allows the user to configure how the space is zoned • All group programming is done using the buttons on the control or sensor
being programmed
![Page 43: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/43.jpg)
Application: Classroom
• Red zone – 1 Pico to turn the whiteboard lights on/off • Blue zone – 1 Pico to select preset levels over desks • Green zone – Row closest to the windows responds to the daylight sensor • Not shown – All fixtures respond to the vacancy sensor
![Page 44: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/44.jpg)
Application: Stairwell
• Design Goal Example: – Minimum light level at all times (15%) – Unoccupied light level 75% – At least three fixtures go to occupied level when person enters
stairwell – Not capable of turning off from any control beside breaker
![Page 45: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/45.jpg)
Application: Stairwell
![Page 46: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/46.jpg)
Application: HVAC Integration
• The Occupancy Sensor indicates room occupancy to the VAV terminal unit to open/close the HVAC damper/vent in the room from HVAC system
• CCO on the PowPak relay can also be used in this way
![Page 47: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/47.jpg)
Project Qualification & Budgeting
Have you ever spent time designing / walking a job only to find out later that your design wasn’t within the customer’s budget/usage/ROI requirements?
![Page 48: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/48.jpg)
Lutron Quick ESTimation Tool can help you qualify a project before you invest man-hours and capital in design and quoting.
Lutron QuEST Tool
![Page 49: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/49.jpg)
When would you use it?
• Reduce chances of redesign by aligning expectations early
• Asks high-level questions that gives you budget, energy, code, ROI information.
• Only for Energi TriPak Solutions right now.
Lutron QuEST
Conceptualization
e gy et o t ocessDesign Submittal
Days Days
Days
Quick Estimate with limited info
Quick Walk-Through and Quick Design
Detailed Audit
Qualification
Energy Retrofit Process
![Page 50: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/50.jpg)
When would you use ETP App?
• After you have Qualified a job with Lutron QuEST, use the ETP Estimator.
• Mobile (iOS) platform ideal for audit • Significantly reduce audit and design time • Only for Energi TriPak Solutions right now.
Energi TriPak Estimator
Energy Retrofit Process
Qualification Concept Design Submit
![Page 51: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/51.jpg)
How does ETP App Work?
Record Room-by-room and Project / Regional Information
One-click!
Generate ETP Solution, Proposal, and BOM
![Page 52: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/52.jpg)
Tools and Other Useful Information • Literature
– Energi TriPak Design Guide – P/N 367-2110 with P/Ns & pricing! – PowPak EcoSystem Info Sheet – P/N 367-2097 – PowPak Relay Info Sheet – P/N 367-2105 – PowPak CCO Info Sheet – P/N 367-2117
• Website – Informational and Programming Videos available online – Live now with spec submittals, CSI specification, CAD icons,
Revit models, and more • Radio Powr Savr Technology Report
– ClearConnect™ RF Communication – Battery Life – XCT™ Passive Infrared Occupancy Sensing
• Faceplate Engraving – Claro faceplates can be laser engraved for ease of use
![Page 53: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/53.jpg)
Questions?
For questions/feedback:
Scott Garrett Systems Application Engineer
Central Area Systems Sales Engineer [email protected]
(484) 695-3905
![Page 54: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/54.jpg)
References Lutron Technical Whitepapers 1. Clear Connect™ RF Technology
2. XCT™ Technology from Lutron®: The New Standard in Sensing
3. Battery Life Discussion – Contact your location System Sales Engineer or Lutron Rep Agent (DIMS)
![Page 55: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/55.jpg)
1. Combined Lighting Energy Savings source: Although combined savings for a building from individual room strategies is not additive, solutions that utilize all strategies typically save 60% or more. Glenn Hughes, director of construction for The New York Times Company building in New York City reports 75% lighting energy savings using Lutron systems. Jeff Choma, manager of mechanical and electrical systems at Georgian College in Ontario, Canada reports 70% lighting energy savings using Lutron systems. Lighting energy savings exceeding 60% is frequently reported by customers using Lutron solutions as part of an overall energy-savings design program. 2. High-End Tuning source: Existing buildings were often designed to much higher light levels than currently recommended. Even in new and newly renovated spaces, unknown room conditions, architectural layout constraints, and design safety factors often create lighted environments that are considerably brighter than needed. High-end trim source: Pacific Gas & Electric Company. 1997. Dimming Controls for Lighting. 3. Occupancy/vacancy sensing source: VonNieda B, Maniccia D, & Tweed A. 2000. An analysis of the energy and cost savings potential of occupancy sensors for commercial lighting systems. Proceedings of the Illuminating Engineering Society. Paper #43. 4. Daylight harvesting source: Brambley MR, et al. 2005. Advanced sensors and controls for building applications: Market assessment and potential R&D pathways. Pacific Northwest National Laboratory: prepared for U.S. Department of Energy. 5. Personal control source: Galasiu AD, et al. 2007. Energy saving lighting control systems for open-plan offices: A field study. Leukos. 4(1) pg. 7-29. 6. Scheduling source: When scheduling is used without occupancy sensing or vacancy sensing, 15% energy savings can be expected. 7. Motorized Window Treatment source: Shading Lutron commissioned simulation by T.C. Chan Center for Building Simulation
and Energy Studies, University of Pennsylvania, September 2008.
8. Plug Load Control: Energy Information Administration, 2003 Commercial Energy Consumption Survey, released September 2008
References
![Page 56: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/56.jpg)
9. FCC Title 47 Part 15.231 – Oet Bulletin No. 63, October 1993. Understanding The FCC Regulations For Low-Power, Non-Licensed Transmitters. Office of Engineering and Technology Federal Communication Commission.
References
![Page 57: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/57.jpg)
Extra Materials
Important Notes: • The Lutron QuEST Tool is ONLY available to Lutron Rep Agency and Lutron Sales Personnel. • The Lutron ETP iOS App is free and will be available through the Apple App Store. This product will require an active myLutron account. Registration is required. Please contact your local Rep or Sales person for registration information.
![Page 58: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/58.jpg)
Fixed Network Diagram
![Page 59: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/59.jpg)
Mesh Network Diagram
![Page 60: Solutions for Single Spaces Energi TriPak2. To understand what the Energi TriPak family is 3. To understand what problems the Energi TriPak can solve for our customers 4. To recognize](https://reader033.vdocuments.mx/reader033/viewer/2022041720/5e4dc732a69d3b294a6e6dd6/html5/thumbnails/60.jpg)
60
For marketing & training purposes only Specifications of Lutron® products subject to change Review of current technical specification documents recommended © Lutron Electronics Co., Inc., 2011