    TIMER3101

    TITLE : TIMER3101

    INCIDENT DATE:

    TT REFERENCE: (NO TT) HEALTH CHECK ON ZWBSC5

    PROBLEM DESCRIPTION

    Failing to adjust TIMER3101

    PROBLEM SYMPTOMS

    REMEDY CONDITIONS

    SOLUTION(S)

    YES, IT IS A PARAMETER HAS SOME STRANGE RE UIREMENTS WHEN IT COMES TO CHANGES!

    HERE IS THE PROCEDURE FOR G13B!

    RAEPP:ID"TIMER3101# $CHECK $

    ES SYS EM#

    PRINT %AR RMSCS &''(15)# $ THIS IS THE HE %ALUE OF T3101 $

    SET %AR RMSCS &''(15)"50# $ SET THE %ALUE OF THE T3101 HERE IN DECIMAL $

    END TEST#

    RAEPC:PROP"TIMER3101 50# $ SET THE %ALE OF THE T3101 THE SAME AS IN THE SET %AR $

    RAEPP:ID"TIMER3101# $ CHECK$

    CAUSE