solution resides in the details · 2020-04-23 · the pannoramic digital slide scanners have won 5...
TRANSCRIPT
DIGITAL IHC
Solution resides in the details
IHC.indd 1 2014.05.07. 21:16:06
Standardized Digital IHC from 3DHISTECH
You need:
Standardized solutionsFor immunohistochemistry, constant quality is essential in all workflow phases. Whether it is
tissue microarray block building, slide staining and scanning or digital image analysis, you can be sure
3DHISTECH products provide the best quality.
High quality brightfield IHC staining and scanningThe Pannoramic digital slide scanners have won 5 of the 9 categories at the 2012 International Scanner
Contest, including image quality and scanning speed. The brand new SCS (Staining-Coverslipping-
Scanning) uses this award-winning scanning technology and combines an IHC stainer and coverslip-
per with it, all in one machine. The closed system approach means the need for human intervention is
minimized.
Dedicated image quantification tools3DHISTECH’s automated IHC quantification software tools are robust, powerful and adapt to different
stain intensity. Advanced pattern recognition is used for tissue separation (epithel, connective tissue),
membrane and nuclei detection algorithms provide per cell analysis. The software can be calibrated to
your lab’s applied IHC staining protocol.
Workflow, consultation, and reporting toolsMore stains mean more data and you need to channel this huge amount of information into easily
managable projects. The immunohistochemistry and TMA workflow tools from 3DHISTECH offer
a flexible and standardized way to deal with these challenges. You can work on remote slides just
like on local cases. The quantification software tool scan show your analysis results in multiple ways:
histograms, scatterplots, galleries, XLS export, and various report types.
Color deconvolution
IHC.indd 2 2014.05.07. 21:16:06
3DHISTECH USA INC.545 Island Rd., Suite 2D,Ramsey, NJ 07446, USA
Phone: +1-212-518-3344
TD.
Info: [email protected] www.3dhistech.com
Tissue preparation
Tissue microarray hardware
3DHISTECH USA INC.545 Island Rd., Suite 2D,Ramsey, NJ 07446, USA
Phone: +1-212-518-3344
TD.
Info: [email protected] www.3dhistech.com
Staining & Imaging
SCS
• 250 slide capacity• Brightfield and 9-channel fluorescent scanning• Flash scanning technology• Motorized objective changer• Motorized camera changer
• Save reagents and time, and achieve standard quality with tissue microarrays
• Up to 550 cores in one block
• 4 core sizes from 0.6 to 2 mm
• Donor block imaging, and digital slide use for precise sampling
• Barcode reading
• NEW! Extraction of sample cores for molecular analysis
TMA Master• 5 block capacity• Small footprint
TMA Grand Master• 72 block capacity• Simultaneous loading, imaging, punching and drilling
Pannoramic250 FLASH
Pannoramic SCAN
• 150 slide capacity• Brightfield and 9-channel fluorescent scanning• Manual camera changer
Pannoramic MIDI
• 12 slide capacity• Brightfield and 9-channel fluorescent scanning• Wet slide compatible• Manual camera changer
Pannoramic DESK• 1 slide capacity• Brightfield scanning• Small footprint• Silent operation
The Pannoramic digital slide scanner systems have won the 2012 International Scanner Contest in the following categories:
• Scanning speed 20x• Scanning speed 40x• Image quality 40x• Image Analysis• Green IT
Pannoramic digital slide scanners
• Automatic white balancing and background elimination• Up to 1 slide per minute scanning speed• Award-winning quality
• IHC stainer, coverslipper, BF & FL scanner in one Standardize and save money, time and lab space!• 72 slides• Up to 40 reagents• Patented technique to detect the unstained sample and to stain only the sample area: save 50% on reagent costs!
IHC.indd 3 2014.05.07. 21:16:12
Production and development by
3DHISTECH USA INC.545 Island Rd., Suite 2D,Ramsey, NJ 07446, USA
Phone: +1-212-518-3344
TD.
Info: [email protected] www.3dhistech.com
Diagnosis
Image quantification applicationsBreast cancer diagnostic tools: dedicated image analysis algorithms for several predictive markers
(ER, PgR, HER2, etc.)
PatternQuant
• Trainable algorithm for tissue segmenta- tion
• Epithel and connective tissue separation for cell based analysis
NuclearQuant
• Predefined profiles for ER, PgR
• Can be adapted to your lab protocols
• Multiple scoring options: positivity index, H-score, Allred, etc.
MembraneQuant
• Predefined profile for HER2
• Positive and negative cell detection
• Can be adapted to your lab protocols
• Multiple scoring options: H-score, field score
DensitoQuant
• Simple, fast yet effective classifica- tion of IHC stained samples
• Area and average intensity measure- ments of classes
Workflow toolsTumorBoard
• For comparing of differently stained samples of the same case
• Manual scoring possibility
• Flexible gallery to support tumor board reviews
• Uses measurement data from the image analysis applications
TMA
• For high throughput tissue microarray analysis
• Project based: multi-user, multi-slide
• Powerful TMA spot gallery
• Uses measurement data from the image quantification applications
3DHISTECH USA INC.545 Island Rd., Suite 2D,Ramsey, NJ 07446, USA
Phone: +1-212-518-3344
TD.
Info: [email protected] www.3dhistech.com
Reviewing and reporting
Measurement Gallery
• Reviewing possibility
• Cell relocalization on the sample
• Single-click rescoring
CaseReport
• Standardized presentation
of the pathology report
• Patient and measurement
data on one sheet
• Reference image from the
diagnostic area
• Printable format
NEW
IHC.indd 4 2014.05.07. 21:16:16