soldering: 1.total dust and elements – 2 personal samples and field blank (3 samples) 2. alcohols...
TRANSCRIPT
Soldering:1. Total Dust and Elements –
2 personal samples and field blank (3 samples)2. Alcohols on 3M 3500 Organic Vapor Monitors
(OVM)– Soldering flux and Flux-Off 2 personal samples and field blank (3 samples)3. Hydrocarbons on separate 3M 3500 OVM – 2-methylpentane, 3-methylpentane, n-hexane, and
ethyl acetate
2 personal samples and field blank (3 samples)
Epoxy:1. Crystalline Silica as Quartz from Epoxy Hardener
1 sample and a field blank (2 samples)2. Talc and Titanium Dioxide from Epoxy Resin
1 sample and a field blank (2 samples)
Conformal Coat:1. Xylene and 2-butanone – Full-shift samples
2 samples and a field blank (3 samples)2. Xylene and 2-butanone – STEL work task
samples2 samples and a field blank (3 samples)
Parts Cleaning:1. Hydrocarbons on 3M 3500 OVM – 2 samples and a field blank (3 samples)2. 1,1,1,2-tetrafluoroethane on separate 3M
3500 OVM 2 samples and a field blank (3 samples)3. Sodium carbonate as alkaline dust –
2 samples and a field blank (3 samples)
MONITORING PLANOne Day for Site Monitoring
Monitoring Equipment – 1. Indoor Air Quality (IAQ) Datalogger Monitoring for CO2, Temp., %RH2. Quest Calibrated Dosimeters 5 and Sound Level Meter
Laboratory Analysis