  • SolarTronics Hybrid Inverter - Diamond Series 3KVA-150KVA

    A) Priority- Solar->Grid->Battery

    B) Priority- Solar->Battery->Grid

    OPERATIONAL SEQUENCE FOR SOLAR OFF-GRID INVERTER

    A) Priority- (solar-grid-battery) (NO CHANGE OVER)

    B) Priority- (solar-battery-grid) (NO CHANGE OVER)

    A) When solar energy is sufficient then total o/p load will operate on solar through MPPT & Inverter. Excess solar power

    will charge batteries.

    When solar energy is weak then inverter is taking DC source from solar & balance from grid.

    When solar energy is absent then the entire load is working on grid via grid charger.

    When grid is absent then the load will be shifted onto batteries and moment the grid energy resumes load will be

    shifted back to grid. During this sequence any discharge of batteries will be refurbished via grid & available solar.

    All the operational logic will work with a zero transfer time for sensitive loads.

    B) When solar energy is sufficient then total o/p load will operate on solar through MPPT & Inverter. Excess solar power

    will charge batteries.

    When solar energy is weak then inverter is taking DC source from solar & balance from batteries.

    When batteries reach 75% discharge level (25% kept as a buffer) the o/p load is shifted to grid without any change over time.

    After shifting load to grid the batteries are charged from solar energy and if solar energy not sufficient to charge the

    batteries, then remaining DC power is taken from grid charger. Once the batteries are fully charged then load is shifted

    back onto battery backup from grid.

    During changeover of load from battery backup to grid supply (i.e 75% battery discharged) and if grid supply is absent then

    load is shifted to inverter to use buffer battery backup (i.e balance 25%)

    When grid returns during which inverter is working on buffer battery backup then the load is shifted to grid & batteries are

    charging through solar or grid as per logic explained above.

  • MODEL

    Rating 3KVA 4KVA 5KVA 6KVA

    DC Voltage 48V/96V

    Solar Voltage range 55V-96V/105V-144V

    Charge Controller

    MPPT Rating 90A

    Grid charger Rating

    Grid Input

    Grid Voltage Range

    Type of Inverter

    O/P Waveform

    O/P Power Capacity 3KVA 4KVA 5KVA 6KVA

    O/P Voltage

    Frequency

    T.H.D

    O/P P.F

    Inverter Efficiency

    Overload Capacity

    Change Over Time

    Duty Cycle

    Operating Mode

    Noise

    Operating Temperature

    Storage Temperature

    Humidity

    Altitude

    Enclosure Protection

    Cooling

    Color

    Cable Entry

    Dimensions

    Weight

    Solar Voltage O/P Voltage Grid Voltage Battery Voltage

    Solar Current O/P Current Grid Current Battery Current

    Solar Power I/P Frequency

    O/P Under Battery Reverse O/P Overload O/P DC Under

    Polarity Frequency

    O/P Over Over Temperature

    MCB at Grid Fuses at Inverter I/P AC Over

    MCB at Array Fuses at Array I/P Short Circuit

    MCB at Battery AC Under DC Over DC Under

    MCB at O/P Over Temperature

    Overload

    Short Circuit

    Above Protections with Alarm

    Pre Alarm

    96V /120V

    115V-200V/130V-240

    Multiples Of 100A (Customized as per requirement )

    Overload & Battery Low

    40kg (3KVA), 50kg (4KVA), 55kg (5KVA), 60kg (6KVA)

    DC Over

    300 X 500 X 500mm?(3KVA), 450mm X 710 m m X 650mm (4KVA - 6KVA )

    Array Reverse

    Polarity

    Protections

    Faults Display

    Metering

    Bottom Rear Side

    Siemens Gray/Black

    0.8 lagging to Unity

    >90%

    Forced Air Cooling

    IP20 or IP21

  • SolarTronics Hybrid Inverter - Diamond Series 8KVA-15KVA

    MODEL

    Rating

    DC Voltage

    Solar Voltage range

    Charge Controller

    MPPT Rating

    Grid charger Rating

    Grid Input

    Grid Voltage Range

    Type of Inverter

    O/P Waveform

    O/P Power Capacity

    O/P Voltage

    Frequency

    T.H.D

    O/P P.F

    Inverter Efficiency

    Overload Capacity

    Change Over Time

    Duty Cycle

    Operating Mode

    Noise

    Operating Temperature

    Storage Temperature

    Humidity

    Altitude

    Enclosure Protection

    Cooling

    Color

    Cable Entry

    Dimensions

    Weight

    Solar Voltage O/P Voltage Grid Voltage Battery Voltage

    Solar Current O/P Current Grid Current Battery Current

    Solar Power I/P Frequency

    Battery Reverse O/P Overload O/P DC Under

    Polarity Frequency

    Over Temperature

    MCB at Grid Fuses at Inverter I/P AC Over

    MCB at Array Fuses at Array I/P Short Circuit

    MCB at Battery AC Under DC Over DC Under

    Over Temperature

    Overload

    Short Circuit

    Above Protections with Alarm

    Pre Alarm Overload & Battery Low

    Bottom Rear Side

    Siemens Gray/Black

    Forced Air Cooling

    IP20 or IP21

    Protections

    MCB at O/P

    750mmx1400mmx1200mm ( 40KVA?60KVA)

    450kg ? 650kg (40KVA?60KVA)

    Metering

    Faults Display

    O/P Under

    O/P OverArray Reverse

    PolarityDC Over

    90%

    0.8 lagging to Unity

  • SolarTronics Hybrid Inverter - Diamond Series 20KVA-30KVA

    MODEL

    Rating

    DC Voltage

    Solar Voltage range

    Charge Controller

    MPPT Rating

    Grid charger Rating

    Grid Input

    Grid Voltage Range

    Type of Inverter

    O/P Waveform

    O/P Power Capacity

    O/P Voltage

    Frequency

    T.H.D

    O/P P.F

    Inverter Efficiency

    Overload Capacity

    Change Over Time

    Duty Cycle

    Operating Mode

    Noise

    Operating Temperature

    Storage Temperature

    Humidity

    Altitude

    Enclosure Protection

    Cooling

    Color

    Cable Entry

    Dimensions

    Weight

    Solar Voltage O/P Voltage Grid Voltage Battery Voltage

    Solar Current O/P Current Grid Current Battery Current

    Solar Power I/P Frequency

    Battery Reverse O/P Overload O/P DC Under

    Polarity Frequency

    Over Temperature

    MCB at Grid Fuses at Inverter I/P AC Over

    MCB at Array Fuses at Array I/P Short Circuit

    MCB at Battery AC Under DC Over DC Under

    Over Temperature

    Overload

    Short Circuit

    Above Protections with Alarm

    Pre Alarm

    >90%

    100%-120% for 30sec

    125%-150% for 0 sec

    0 Seconds for Atlas series.

  • SolarTronics Hybrid Inverter - Diamond Series 40KVA-60KVA

    MODEL

    Rating

    DC Voltage

    Solar Voltage range

    Charge Controller

    MPPT Rating

    Grid charger Rating

    Grid Input

    Grid Voltage Range

    Type of Inverter

    O/P Waveform

    O/P Power Capacity

    O/P Voltage

    Frequency

    T.H.D

    O/P P.F

    Inverter Efficiency

    Overload Capacity

    Change Over Time

    Duty Cycle

    Operating Mode

    Noise

    Operating Temperature

    Storage Temperature

    Humidity

    Altitude

    Enclosure Protection

    Cooling

    Color

    Cable Entry

    Dimensions

    Weight

    Solar Voltage O/P Voltage Grid Voltage Battery Voltage

    Solar Current O/P Current Grid Current Battery Current

    Solar Power I/P Frequency

    Battery Reverse O/P Overload O/P DC Under

    Polarity Frequency

    Over Temperature

    MCB at Grid Fuses at Inverter I/P AC Over

    MCB at Array Fuses at Array I/P Short Circuit

    MCB at Battery AC Under DC Over DC Under

    Over Temperature

    Overload

    Short Circuit

    Above Protections with Alarm

    Pre Alarm

    Multiples Of 100A (Customized as per requirement )

    SolarTronics Hybrid Inverters-Diamond Series (40KVA - 60KVA)

    40KVA 50KVA 60KVA

    240V/360V 240V/360V 240V/360V

    255 V - 500V O R 355V - 700V

    MPPT based Charge Controller

    100%-120% for 30sec

    125%-150% for 0 sec

    As Per System & Battery Capacity

    Three Phase

    160V-270V or 340V-470V

    IGBT based PWM Inverter

    Pure Sine wave

    50KVA 60KVA

    415 + 1% (3-Phase)

    50Hz

  • SolarTronics Hybrid Inverter - Diamond Series 80KVA-150KVA

    MODEL

    Rating 80KVA 100KVA 120KVA 150KVA

    DC Voltage

    Solar Voltage range

    Charge Controller

    MPPT Rating

    Grid charger Rating

    Grid Input

    Grid Voltage Range

    Type of Inverter

    O/P Waveform

    O/P Power Capacity 80KVA 100KVA 120KVA 150KVA

    O/P Voltage

    Frequency

    T.H.D

    O/P P.F

    Inverter Efficiency

    Overload Capacity

    Change Over Time

    Duty Cycle

    Operating Mode

    Noise

    Operating Temperature

    Storage Temperature

    Humidity

    Altitude

    Enclosure Protection

    Cooling

    Color

    Cable Entry

    Dimensions

    Weight

    Solar Voltage O/P Voltage Grid Voltage Battery Voltage

    Solar Current O/P Current Grid Current Battery Current

    Solar Power I/P Frequency

    Battery Reverse O/P Overload O/P DC Under

    Polarity Frequency

    Over Temperature

    MCB at Grid Fuses at Inverter I/P AC Over

    MCB at Array Fuses at Array I/P Short Circuit

    MCB at Battery AC Under DC Over DC Under

    Over Temperature

    Overload

    Short Circuit

    Above Protections with Alarm

    Pre Alarm

    Protections

    MCB at O/P

    Overload & Battery Low

    750mm X 1400mm X 1200mm ( 8 0 K V A - 1 5 0 K V A )

    750kg?800kg (80kVA), 1000kg (100kVA) ,1025kg (120kVA) ,1100kg (150kVA)

    Metering

    Faults Display

    O/P Under

    O/P OverArray Reverse

    PolarityDC Over

    95% (Non Condensing)