sokkia cx
DESCRIPTION
Sokkia CXTRANSCRIPT
-
RED-tech Technology Reflectorless EDM Long-range Bluetooth Technology Advanced Angle Measurement System The Longest Battery Life 36 Hours! Waterproof, Rugged, and Operator Friendly Advanced Security and Maintenance with TSshieldTM
CX SeriesCompaCt X-ellenCe Station
Tradition Meets Innovation
-
Long-Range Bluetooth Technology*
TheCXseriesoftotalstationsfeaturesBluetoothClass1wirelesstechnologyforreliabledatacommunications. AllCXdataisinstantlyavailableattheBluetooth-equippedcontroller. *Offeredasanoptioninsomeareas.
Advanced Angle Measurement System CXfeaturesSokkiasoriginal absoluteencodersthatprovide long-termreliabilityinany jobsitecondition.Dual-axis compensatorensuresstable measurementsevenwhen setuponuneventerrain. Sokkiastraditionalmotion clampandtangentscreware employedtoensurestable anglemeasurement.CX-101andCX-102featuregroundbreakingIACS(Independent AngleCalibrationSystem)technologyforextremelyreliable anglemeasurement.
The Longest Battery Life - 36 Hours! TheCXsinglebatterycan lastupto36hours.* Greatlyreduceslikelihoodof lowpowerduringany full-dayswork.Eliminatestheneedfor nightlyrechargingorcarrying extrabatteries. *Operatingtimewillvarydependingupon environmentalconditionsandCXactivity.
RED-tech Technology Reflectorless EDM
Fastestmeasurmenttimeinitsclass. Sokkiatraditionalpinpointprecisioninreflectorlessdistance measurement.Reflectorlessoperationfrom30cmto500m.CoaxialEDMbeamandlaser-pointerprovidefastandaccurateaiming.Ensuresaccuracyevenwithreflectivesheets.
Inspired by Tradition, Ready for The Future.
Theultra-narrowEDMbeamcanpreciselymeasurewalls,corners,manholesontheroadsurface,evenchain-linkfencesandtreebranches.
-
Waterproof, Rugged, and Operator Friendly IP66dustproof/waterproofrating. Metalchassisandheavydutyhandle addruggedness. Standardusagetemperature range-20to+50C.Low temperaturemodelscanbeusedas lowas-30C*andhightemperature modelsupto+60C.* *LowandHightemperaturemodelsavailableasoptions.
USBTypeAportforconvenientadded memory.UseofincludedUSB accessoryassuresIP66protection.
One-touchSTARkeyoffersinstant accesstofunctions.
Convenientlylocatedtriggerkeylets youtakeaseriesofmeasurements withthepushofabuttonwithout takingyoureyeoffthetelescope.
Controlpanelfeatures10-keypad withlargeLCDthatprovidesoptimum viewingandconvenience.* *Controlpanellocationmayvarydependingonregion ormodel.
Green/Redtelescopeguidelightenhancesworkefficiencyin arangeupto150m.
Built-inlaserplummetwithfivebrightnesslevelsisequippedfor quickinstrumentsettinginalllightingconditions.(optional)
TSshield EveryCXtotalstationisequippedwithatelematics-basedmultifunctioncommunicationsmoduleprovidingtheultimatesecurityandmaintenancecapabilitiesforyourinvestment.Ifanactivatedinstrumentislostorstolen,youcansendacodedsignaltotheinstrumentanddisableitYourtotalstationissecureanywhereintheworld!And,inthesamemodule,youhavedailyconnectivitytocloud-basedSokkiaserversthatcaninformyouofavailablesoftwareupdatesandfirmwareenhancements. * FormoredetailofTSshield,pleaserefertotheTSshieldsleaflet.
High-temp ModelsStandard Models
Low-temp Models-30C (-22F)
-20C (-4F)
0C (+32F)
+50C (+122F)
+60C (+140F)
Operating temperature range
-
Sokkia Corporation16900 W. 118th Terrace Olathe, KS 66061Phone (800) 4-SOKKIA Fax: (913) 492-0188
www.sokkia.com
Specifications subject to change without notice2013 Topcon Corporation All rights reserved.
Your local Authorized Dealer is:
CX Series SPECIFICATIONS
-BluetoothwordmarkandlogosareregisteredtrademarksownedbyBluetoothSIG,Inc.andanyuseofsuchmarksbyTopconisunderlicense.Othertrademarksandtradenamesarethoseoftheirrespectiveowners.-Designsandspecificationsaresubjecttochangewithoutnotice.-Productcolorsinthisbrochuremayvaryslightlyfromthoseoftheactualproductsowingtolimitationsoftheprintingprocess.
Compact X-ellence Station
Standard AccessoriesCXmainunit LensbrushBattery(BDC70) Adjustingpinx2Batterycharger(CDC68) CleaningclothPowercable OperationmanualLenscap USBmemorystickLenshood Lasercautionsign-boardToolpouch CarryingcaseScrewdriver Carryingstrap
CX-101/CX-102/CX-103/CX-105/CX-107
Model CX-101 CX-102 CX-103 CX-105 CX-107
Telescope
Magnification/Resolvingpower 30x/2.5" 30x/3.5"Others Length:171mm(6.7in.),Objectiveaperture:45mm(1.8in.)(48mm(1.9in.)forEDM),
Image:Erect,Fieldofview:130'(26m/1,000m),Minimumfocus:1.3m(4.3ft.),Reticleillumination:5brightnesslevelsAngle MeasurementDisplayResolution 0.5"/1"
(0.0001/0.0002gon,0.002/0.005mil)
1"/5"(0.0002/0.001gon,0.005/0.02mil)
Accuracy(ISO17123-3:2001) 1" 2" 3" 5" 7"
IACS(IndependentAngleCalibrationSystem) Provided -
Dual-axiscompensator/Collimationcompensation Dual-axisliquidtiltsensor,workingrange:6'(111mgon)/Collimationcompensationavailable
Distance Measurement
Laseroutput*1 Reflectorlessmode:Class3R/Prism/sheetmode:Class1
Measuringrange(underaverageconditions*2)
Reflectorless*3 0.3to500m(1.0to1,640ft.)
Reflectivesheet*4/*5 RS90N-K:1.3to500m(4.3to1,640ft.),RS50N-K:1.3to300m(4.3to980ft.),RS10N-K:1.3to100m(4.3to320ft.)
Miniprisms CP01:1.3to2,500m(8,200ft.),OR1PA:1.3to500m(1,640ft.)
OneAPprism 1.3to4,000m(4.3to13,120ft.)/Undergoodconditions*6:5,000m(16,400ft.)
ThreeAPprisms to5,000m(16,400ft.)/Undergoodconditions*6:to6,000m(19,680ft.)
DisplayResolution Fine/Rapid:0.001m/0.01ft./1/8in.Tracking:0.01m/0.1ft./1/2in.
Accuracy*2(ISO17123-4:2001)(D=measuringdistanceinmm)
Reflectorless*3 (3+2ppmxD)mm*7
Reflectivesheet*4 (3+2ppmxD)mm
AP/CPprism (2+2ppmxD)mm
Measuringtime*8 Fine:0.9s(initial1.7s),Rapid:0.7s(initial1.4s),Tracking:0.3s(initial1.4s)
Interface and Data management
Display/Keyboard GraphicLCD,192x80dots,backlight,contrastadjustment/Alphanumerickeyboard/25keyswithbacklight
Controlpanellocation*9 Onbothfaces Ononeface
Triggerkey Onrightinstrumentsupport
Datastorage Internalmemory Approx.10,000points
Plug-inmemorydevice USBflashmemory(max.8GB)
Interface SerialRS-232C,USB2.0(TypeA,forUSBflashmemory)
Bluetoothmodem(option)*10 BluetoothClass1,Ver.2.1+EDR,Operatingrange:upto300m(980ft.)*11
General
Laser-pointer*12 CoaxialredlaserusingEDMbeam
Guidelight*12 GreenLED(524nm)andRedLED(626nm),Operatingrange:1.3to150m(4.3to490ft.)*2
Levels Graphic 6(InnerCircle)
Circularlevel 10/2mm
Opticalplummet Magnification:3x,Minimumfocus:0.3m(11.8in.)fromtribrachbottom
Laserplummet(option) Redlaserdiode(635nm10nm),Beamaccuracy:[email protected],Class2laserproduct
Dustandwaterprotection IP66(IEC60529:2001)
Operatingtemperature*13 -4to+122F(-20to+50C)Sizewithhandle*9 Controlpanelonbothfaces:W7.5xD7.1xH13.7in.(W191xD181xH348mm)
Controlpanelononeface:W7.5xD6.9xH13.7in.(W191xD174xH348mm)Weightwithbattery&tribrach Approx.12.3lb.(5.6kg)
Power supply
Battery(BDC70) Detachablebattery Li-ionrechargeablebattery
Operatingtime(20C) BDC70 Approx.36hours(singledistancemeasurementevery30seconds)
Externalbattery*14(Optional) BDC60:approx.44hours,BDC61:approx.89hours(singledistancemeasurementevery30seconds)
*1IEC60825-1:Ed.2.0:2007/FDACDRH21CFRPart1040.10and11*2Averageconditions:Slighthaze,visibilityabout20km(12miles),sunnyperiods,weakscintillation.*3WithKodakGrayCardWhiteSide(90%reflective).Whenbrightnessonmeasuredsurfaceis30,000lx.orless.Reflectorlessrange/accuracymayvaryaccordingtomeasuringobjects,observationsituationsandenvironmentalconditions.*4Whenthemeasuringbeamsincidenceangleiswithin30inrelationtothereflectivesheettarget.*5Measuringrangeintemperaturesof-30to-20C(-22to-4F)withLowTemperaturemodelsand50to60C(122to140F)withHighTemperaturemodels:RS90N-K:1.3to300m(4.3to980ft.),RS50N-K:1.3to180m(4.3to590ft.),RS10N-K:1.3to60m(4.3to190ft.)*6Goodconditions:Nohaze,visibilityabout40km(25miles),overcast,noscintillation.*7Measuringrange:0.3to200m*8Typical,undergoodconditions.Reflectorlessmeasurementtimemayvaryaccordingtomeasuringobjects,observationsituationsandenvironmentalconditions.*9Controlpanellocationmayvarydependingonregionormodel.*10UsageapprovalofBluetoothwirelesstechnologyvariesaccordingtocountry.Pleaseconsultyourlocalofficeorrepresentativeinadvance.*11Noobstacles,fewvehiclesorsourcesofradioemissions/interferenceinthenearvicinityoftheinstrument,norain.*12Thelaser-pointerandtheguidelightdonotworksimultaneously.*13LowTemperaturemodels:-30to50C(-22to122F)andHighTemperaturemodels:-20to60C(-4to140F,Nodirectsunlight)areavailableonbuilt-to-orderbasis.*14ForCX-101,CX-102andLowtemperaturemodels.
SOK-1008RevB3/13