soft switch - wordpress.com · pdf file history spc • early exchanges (strowger and...

18
www.telkomuniversity.ac.id Fathur AB Anin A Afif A Hari A Gary A Dhika AB April AB Mulya AB Rizka B Dion AB Siska AB Mirel AB Hani AB Airita AB Yusuf AB Pilsung AB Taegyun A

Upload: duongdat

Post on 27-Mar-2018

218 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Fathur AB

Anin A

Afif A

Hari A

Gary A

Dhika AB

April AB

Mulya AB

Rizka B

Dion AB

Siska AB

Mirel AB

Hani AB

Airita AB

Yusuf AB

Pilsung AB

Taegyun A

Page 2: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Stored Program Control

Course Number : TTH2A3

CLO : 3

Week : 8

Page 3: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Media Gateway on NGN

• Media Gateway (MG)

– On Transport plane that connects different type of network – Trunk Gateway, connects packet-based network with trunk network from PSTN

or ISDN – Access Gateway, provides services to CPE – Residential Gateway, connects

packet-based network with analog network

• Signaling Gateway (SG)

– Transforming signaling format, ex. SIP SS7

• Media Gateway Controller (MGC)

– Control Media Gateway and Signaling Gateway

– aka. Soft Switch (call setup for multimedia communication, detect and manage events, and manage media gateway based on configuration)

– Use MGCP (MGC Protocol) from ITU-T or Megaco from IETF

Page 4: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Layers in NGN

4

Page 5: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Crossbar Switch

• Electro-mechanical switch by using relay contact

• Numbers are stored in register to establish a call by activating several relay. This activation is done by marker

• Marker will become SPC (Stored Program Control)

Page 6: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Unit Interface for Digital SPC

Page 7: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

What is SPC?

SPC (Stored program control) is:

• a telecommunications technology used for telephone exchanges

• controlled by a computer program stored in the memory of the switching system

• SPC was the enabling technology of electronic switching systems (ESS) developed in the Bell System in the 1950s.

source: Wikipedia

Page 8: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Inside the Digital Local Exchange

MD

F M

DF

Subscriber Concentrator Unit Subscriber Concentrator Unit Group Switch Unit Group Switch Unit

subscriber line termination unit

subscriber line termination unit

MU

X

MU

X

digital line termination unit (DLTU)

digital line termination unit (DLTU)

subscriber concentrator switch block

subscriber concentrator switch block

exchange control system exchange control system

analog trunk termination unit

analog trunk termination unit

DD

F D

DF

group switch block

group switch block

CAS CAS

CCS CCS

DLTU DLTU

DLTU DLTU

DLTU DLTU

DLTU DLTU

analog trunk

digital trunk

switch block control

switch block control

switch block control

switch block control

Page 9: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

History SPC

• Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without software control

• Invented by Bell Labs scientist Erna Schneider Hoover in 1954

• SPC was introduced in electronic switching systems in the 1960s

• 101ESS PBX was a transitional switching system in the Bell System

• Western Electric 1ESS switch and the AXE telephone exchange by Ericsson were large-scale systems in the public switched telephone network

• SPC enabled sophisticated calling features

• The addition of time-division multiplexing (TDM) decreased subsystem sizes and dramatically increased the capacity of the telephone network

• By the 1980s, SPC technology dominated the telecommunications industry.

source: Wikipedia

Page 10: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Exchange Control System

• Consists of CPU and Memory, to control relay switch

• CPU could be:

– Distributed Control • Vertical Decomposition

• Horizontal Decomposition

– Centralized Control • Standby Mode

• Synchronous Duplex Mode

• Load Sharing Mode

Page 11: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

CPU Configuration

• Distributed Control, more available and more reliable

– Vertical Decomposition, 1 CPU for 1 block of exchange

– Horizontal Decomposition, 1 CPU performs 1 function

• Centralized Control

– Standby Mode, 1 CPU on + 1 CPU standby

– Synchronous Duplex Mode, 2 CPU on, provide 2 results to compared

– Load Sharing Mode, all CPU on, load is shared in random

Page 12: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Trunk and Subscriber Line

• Trunk: analog or digital

• Subscriber: analog (PSTN, PBX) or digital (ISDN BRA, PBX PRA)

• Terminating unit should considers: – Varying distance for each subscriber

– Signaling message translation

– Some subscriber still needs ringing current and power feeding

– Features for maintenance and testing

Page 13: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Subscriber Line Termination Unit

Analog SLTU should provides functionalities:

• Battery feeding (power supply, ex. to CPE) -48VDC

• Over voltage protection (ex. from lightning)

• Ringing current (to bell customer)

• Supervision (to detect CPE condition)

• Coding (encoding and decoding between analog and digital)

• Hybrid transformer (conversion from 2-wire to 4-wire)

• Channel testing

Page 14: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Subscriber Line Termination Unit

Digital SLTU should provides functionalities:

• Transfer non-voice data

• Use 64 kbps for data transmission

• Use 16 kbps for signaling (CCS)

• Consists of NTU (Network Termination Unit) and TA (Terminal Adapter)

• Supervision is done at TA

Page 15: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Single Processor vs. Dual Processor

• Availability

Page 16: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Single Processor vs. Dual Processor

Page 17: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

Page 18: Soft Switch   - WordPress.com · PDF file  History SPC • Early exchanges (Strowger and crossbar switches) used analog components (electromechanical switching) without

www.telkomuniversity.ac.id

See you on next class