smoking is not allowed! · withstand constant vibrations, are corrosion resistant and where...

5
[email protected] +44 (0)115 978 4652 Termate’s Low Smoke Stand-off Insulators comply with the safety standards required in worldwide traction systems Smoking is not allowed! 1 High fire retardancy 1 Self extinguishing UL94-V0 1 Zero halogen 1 Low smoke 1 Wide range of heights and profiles

Upload: others

Post on 30-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Smoking is not allowed! · withstand constant vibrations, are corrosion resistant and where appropriate are manufactured in halogen free, low smoke and low toxicity materials. We

[email protected]+44 (0)115 978 4652

Termate’s Low Smoke Stand-off Insulators comply with the safety standards required in worldwide traction systems

Smoking is not allowed!

1 High fire retardancy1 Self extinguishing UL94-V01 Zero halogen1 Low smoke1 Wide range of heights and profiles

Page 2: Smoking is not allowed! · withstand constant vibrations, are corrosion resistant and where appropriate are manufactured in halogen free, low smoke and low toxicity materials. We

Termate have manufactured high performance components since 1956, supplying a global customer base from our U.K. headquarters with the support of our international distribution network.

For over 50 years Termate have worked with leading manufacturers of Rail and Tram systems as well as associated infrastructure throughout the world.

We manufacture Stud Type Terminals, Terminal Assemblies, Terminal Boxes, Ultra Low Smoke Zero Halogen Electrical Insulators and Pillars and flexible connectors. This catalogue displays our range of Low Smoke Stand-off Insulators. You may also be interested in Termate’s Cygnus and Thermoset Stand-offs, www.termate.com/lv-powerproducts/stand-off-insulators.

Our products have been tested to major international standards to ensure that they perform in temperatures which range from high to sub-zero, that they can withstand constant vibrations, are corrosion resistant and where appropriate are manufactured in halogen free, low smoke and low toxicity materials.

We are well known by our customers for the detailed application engineering and the first class customer service we offer. Whether your project involves rolling stock or infrastructure Termate application engineering team will help you select and specify the right product for your application.

We hope that our Low Smoke Stand-offs are of interest. If you would like to receive a quote, application help or learn more about any of our products or services, we would be delighted to hear from you.

You can find out more information by visiting our website at www.termate.com, alternatively you can email our sales team at [email protected] or call +44 (0)115 978 4652.

Page 3: Smoking is not allowed! · withstand constant vibrations, are corrosion resistant and where appropriate are manufactured in halogen free, low smoke and low toxicity materials. We

TYP

E 1TY

PE 2

TYP

E 3TY

PE 4

TYP

E 5

Low Smoke InsulatorsFemale to Female & Female to Male

Type 1-5 Properties

Material: Glass Reinforced Polyester DMC with High Fire Retardancy & Low Smoke Emissions.

Conductor Temp: 140°C Continuous

Oxygen Index: 70%

Flammability: UL94-V0

NF F Class: 16-101/102 IO,F1

Female Insert: Brass

Male Insert: Mild Steel Zinc & Passivated

Glow Wire: 960°C

Equipment Voltage Ue: 1000V

Insulation Voltage Ui: 1000V

Impulse Voltage Uimp

: 12kV

Termate reserves the right to alter, without notice, the specification, design, or condition of supply of all its products and services. Dimensions in this catalogue are provided for reference only.

Page 4: Smoking is not allowed! · withstand constant vibrations, are corrosion resistant and where appropriate are manufactured in halogen free, low smoke and low toxicity materials. We

H W

D

M

D

TYPE 1

H W

D

M

D

TYPE 2 & 3

H W

D

M

L

TYPE 4

H W

M

D

L

TYPE 5

ReferenceTightening Torque

Type Part NumberFemale Male

Height [H] mm

Width [W] mm

Thread [M]

Depth[D] mm

Length[L] mm

Max (Nm)

Max (Nm)

25 25 M6 7 – 7 – 1 LSH625

35 25 M8 10 – 14 – 1 LSH835

35 46 M6 10 – 7 – 2 L3635

35 46 M8 10 – 14 – 2 L3835

35 46 M10 10 – 33 – 2 L31035

40 25 M8 10 – 14 – 1 LSH840

45 45 M8 10 – 14 – 1 LSH845

45 46 M10 10 – 33 – 2 LSO1045

50 25 M8 10 – 14 – 1 LSH850

50 46 M8 10 – 17 – 2 LSO850

51 51 M8 10 – 17 – 3 L3850

51 51 M10 16 – 33 – 3 L31050

51 51 M12 16 – 40 – 3 L31250

60 25 M8 10 – 14 – 1 LSH860

60 55 M8 10 – 17 – 3 L3860

60 55 M10 16 – 33 – 3 L31060

60 55 M12 16 – 57 – 3 L31260

60 55 M16 22 – 95 – 3 L31660

70 55 M8 10 – 17 – 3 L3870

70 55 M10 16 – 33 – 3 L31070

70 55 M12 16 – 57 – 3 L31270

35 25 M8 10 28 14 14 4 LSH835H28

40 25 M8 10 28 14 14 4 LSH840H28

60 55 M10/12 16 40 33 33 5 L31060M12

Fixing details: Hole diameter = stand-off thread size [M]+1 mm. e.g. M6 Thread = 7 mm hole diameter.Other sizes of Low Smoke Stand-off insulators may be available. Please contact Termate for a quotation.