SMARTONLINE 3-PHASE UPS SYSTEMS • 220/380 , 230/400 or 240/415 VAC The Most Reliable and Cost-Effective Power Solutions for Your Data Center SMARTONLINE E3 SERIES (20 - 80 KVA) IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS MODULAR ARCHITECTURE ELIMINATES DOWNTIME 1-TO-1 GENERATOR SIZING LOWERS INSTALLATION COSTS EXTREME EFFICIENCY LOWERS OPERATING COSTS SMARTONLINE T3 SERIES (30 KVA) RELIABLE OPERATION KEEPS EQUIPMENT POWERED VERSATILE BATTERY SYSTEM EXPANDS RUNTIME OPTIONS SUPPORT UP TO 320 KVA IN PARALLEL

Upload: vuthuan

Post on 31-Jan-2018

267 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: SMARTONLINE 3-PHASE UPS SYSTEMS - Anixter Lite/Brochures... · SMARTONLINE ™ 3-PHASE UPS SYSTEMS ... External Battery Cabinet 80 kVA UPS System 60 kVA Load 20 kVA ... saving 1-to-1

SMARTONLINE™ 3-PHASE UPS SYSTEMS •220/380,230/400or240/415VAC

TheMostReliableandCost-EffectivePowerSolutionsforYourDataCenter

SMARTONLINE E3 SERIES (20-80KVA)

IDEAL OUTPUT POWER PROTECTSCRITICALSYSTEMS

MODULAR ARCHITECTURE ELIMINATESDOWNTIME

1-TO-1 GENERATOR SIZING LOWERSINSTALLATIONCOSTS

EXTREME EFFICIENCY LOWERSOPERATINGCOSTS

SMARTONLINE T3 SERIES (30KVA)

RELIABLE OPERATION KEEPSEQUIPMENTPOWERED

VERSATILE BATTERY SYSTEM EXPANDSRUNTIMEOPTIONS

SUPPORT UP TO

320 KVA IN PARALLEL

Page 2: SMARTONLINE 3-PHASE UPS SYSTEMS - Anixter Lite/Brochures... · SMARTONLINE ™ 3-PHASE UPS SYSTEMS ... External Battery Cabinet 80 kVA UPS System 60 kVA Load 20 kVA ... saving 1-to-1

SMARTONLINE E3 SERIES UPS SYSTEMSExtremely efficient protection for your most important equipment

IDEAL OUTPUT POWER PROTECTSCRITICALSYSTEMSOn-line, double conversion operation continuously delivers precision-regulated, pure sine wave output, isolating your critical systems from damaging and disruptive power problems.

MODULAR ARCHITECTURE ELIMINATESDOWNTIMEInternal N+1 power module redundancy, parallel capability (up to four units) and fault-tolerant bypass features keep your critical systems highly available and productive around the clock.

1-TO-1 GENERATOR SIZING LOWERSINSTALLATIONCOSTSAn advanced IGBT rectifier produces best-in-class <4% THDi (input Total Harmonic Distortion), eliminating costly over-sizing requirements for generators, breakers and cables.

EXTREME EFFICIENCY LOWERSOPERATINGCOSTSEfficiency up to 97% significantly lowers power and cooling costs compared to multiple smaller units or legacy high-capacity units.

2

RELIABLE OPERATION KEEPSEQUIPMENTPOWEREDOn-line operation and fault-tolerant bypass features keep your equipment powered at all times.

VERSATILE BATTERY SYSTEM EXPANDSRUNTIMEOPTIONSA hot-swappable battery system with convenient front-panel access allows you to customize battery backup runtime.

SMARTONLINE T3 SERIES UPS SYSTEMSReliable protection for small and mid-range installations

C O N T E N T S

C O N T E N T S

SMARTONLINE E3 SERIES UPS SYSTEMS

SU80KX 80kVA/64kW

SU60KX 60kVA/48kW

SU40KX 40kVA/32kW

SU20KX 20kVA/16kW

IDEAL OUTPUT POWER 3MODULAR ARCHITECTURE 3PARALLEL FEATURES 31-TO-1 GENERATOR SIZING 4EXTREME EFFICIENCY 4GREEN POWER 4 MONITORING AND CONTROL 5 BATTERY CABINETS 5 COMPACT FOOTPRINT 6ORDERING INFORMATION 6TECHNICAL SPECIFICATIONS 7

SMARTONLINE T3 SERIES UPS SYSTEMSSU30K3/3INT 30kVA / 24kW

TECHNICAL SPECIFICATIONS 7 RELIABLE OPERATION 8VERSATILE BATTERY SYSTEM 8ORDERING INFORMATION 8

Page 3: SMARTONLINE 3-PHASE UPS SYSTEMS - Anixter Lite/Brochures... · SMARTONLINE ™ 3-PHASE UPS SYSTEMS ... External Battery Cabinet 80 kVA UPS System 60 kVA Load 20 kVA ... saving 1-to-1

IDEAL OUTPUTPOWERSmartOnline E3 Series UPS Systems isolate your critical equipment from power problems, including surges, line noise, harmonic distortion, electrical impulses, frequency variations, brownouts, overvoltages and blackouts. True on-line operation continually transforms AC input power into filtered DC power, then resynthesizes it into precision-regulated AC output with a pure sine wave. Strong overload capacity supports up to 150% output for up to 60 seconds. Reliable backup power with zero transfer time to battery keeps equipment operating safely through shorter power failures and allows time to shut down or switch to generator power during longer outages. Rapid recharging restores battery charge levels in as little as two hours.

MODULAR ARCHITECTUREIntelligent, independent 20 kVA power modules provide internal redundancy. When the UPS is configured for N+1 redundancy, convenient hot-swap power modules can be replaced without powering down the connected load. In the event of a power module fault, the load is automatically distributed among the remaining modules. Because load redistribution happens without interrupting critical systems, mean time to recovery is zero—far superior to legacy UPS systems. In addition, redundant control circuits eliminate a single point of failure commonly found in less-reliable UPS designs. Dual input connections provide an additional level of redundancy by allowing each UPS system to be powered by two separate utility sources.

If service or repair requires UPS shutdown, all models include a manual bypass breaker and automatic bypass function that maintain system availability by passing through AC power until the UPS system returns to service.

PARALLEL FEATURESIncrease fault tolerance or quadruple output capacity by connecting up to four SmartOnline E3 Series UPS Systems in parallel. If one UPS system is taken offline for maintenance, the other UPS systems automatically compensate to support the equipment load—without requiring additional programming.

SmartOnline E3 Series UPS Systems ship ready for parallel operation. Patented dual-DSP technology provides optimal synchronization of power sources.

External Battery Cabinet 80 kVA UPS System

60 kVALoad

20 kVARedundancy

20 kVAPower Module

20 kVAPower Module

20 kVAPower Module

20 kVAPower Module

MODULAR DESIGN ARCHITECTURE INTERNAL N+1 REDUNDANCY

80 kVAUPS System

80 kVAUPS System

80 kVAUPS System

80 kVAUPS System

80 kVAUPS System

80 kVAUPS System

80 kVAUPS System

80 kVAUPS System

240 kVALoad

320 kVALoad

PARALLEL FOR N+1 REDUNDANCY

PARALLEL TO MAXIMIZE CAPACITY

80 kVA80 kVA 80 kVA 80 kVA

80 kVAUPS System

80 kVAUPS System

80 kVAUPS System

80 kVAUPS System

80 kVAUPS System

80 kVAUPS System

80 kVAUPS System

80 kVAUPS System

240 kVALoad

320 kVALoad

PARALLEL FOR N+1 REDUNDANCY

PARALLEL TO MAXIMIZE CAPACITY

80 kVA80 kVA 80 kVA 80 kVA

Four 80 kVA SmartOnline E3 Series UPS Systems can provide backup power for a 320 kVA load.

Four 80 kVA SmartOnline E3 Series UPS Systems can provide redundant backup power for a 240 kVA load.

In an N+1 configuration, the supported load is at least 20 kVA less than the maximum output capacity of the UPS system. For example, an 80 kVA UPS is configured for N+1 redundancy when the connected load is 60 kVA or less.

SMARTONLINE E3 SERIES UPS SYSTEMS

3

Page 4: SMARTONLINE 3-PHASE UPS SYSTEMS - Anixter Lite/Brochures... · SMARTONLINE ™ 3-PHASE UPS SYSTEMS ... External Battery Cabinet 80 kVA UPS System 60 kVA Load 20 kVA ... saving 1-to-1

1-TO-1 GENERATORSIZINGSmartOnline E3 Series UPS Systems have

a generator-friendly design that decreases

installation costs. A high input power

factor and IGBT rectifier with DSP control

create less than 4% input Total Harmonic

Distortion (THDi). Low THDi enables cost-

saving 1-to-1 sizing of UPS systems to

generators, allows generators to run cooler

and extends the operational lifespan of all

input components. Low THDi also reduces

sizing requirements for cables and breakers

and improves reliability by eliminating

nuisance breaker tripping and overheated

transformers.

Legacy UPS Energy Usage (MWh)

SmartOnline E3 Energy Usage (MWh)

Legacy UPS CO2 Emissions (Metric Tons)

SmartOnline E3 CO2 Emissions (Metric Tons)

CUMULATIVE ENVIRONMENTAL IMPACT OVER FIVE YEARS

1956

1752

11881065

1

3911

3504

2378

2130

2

5867

5256

3566

3195

3

78237008

47554259

4

97798760

5944

5324

5

GREEN POWEREfficient SmartOnline E3

Series UPS Systems save

energy and reduce your

carbon footprint. Replacing

160 kVA of legacy UPS

capacity can reduce CO2 emissions by

123 metric tons and save more than 200

megawatt-hours* of electricity per year—

enough to power 16 single-family homes.

An extremely wide voltage correction

range reduces battery wear up to 40%,

so batteries last longer. Batteries are also

recyclable and contain a high percentage

of recycled materials, creating an efficient

manufacturing loop that conserves

resources and reduces landfill waste.

Tripp Lite also restricts hazardous

substances during manufacture,

maintaining industry leadership

in RoHS compliance.

* 1 megawatt-hour = 3,6 gigajoules.

EXTREME EFFICIENCYAdvanced high-utilization IGBT inverter technology and high-speed DSP control provide

superior operating efficiency at all load levels—up to 97% in economy mode. Increasing

efficiency lowers UPS system operating costs by reducing electricity consumption, heat

emissions and cooling costs. Replacing 160 kVA of legacy UPS capacity with SmartOnline

E3 UPS Systems can save more than US$20 000 per year.

In addition, SmartOnline E3 Series UPS Systems automatically correct the widest range of

incoming voltages in their class. The wide voltage window and temperature-compensated

charging combine to decrease battery wear significantly, extending service life and

reducing replacement costs.

The extreme efficiency of SmartOnline E3 Series UPS Systems can reduce your data center’s power costs significantly. Replacing 160 kVA of

legacy capacity can save more than US$20 000 per year.SmartOnline E3 Series UPS Systems reduce

installation costs up to 30% versus legacy UPS systems.

INSTALLATION COST COMPARISON

Generators

Cabling

Breakers

Related Costs

Cost

Smar

tOnl

ine

E3

Leg

acy

UPS

SmartOnline E3

Legacy UPS

100%

85%

70%

50% 75% 100%

SmartOnline E3 SeriesExtreme EfficiencyAdvantage

LOAD

EFF

ICIE

NC

Y

EFFICIENCY CHART

Replacing 160 kVA of legacy UPS capacity with SmartOnline E3 Series UPS Systems can save 200 megawatt-hours* and reduce CO2 emissions by 123 metric tons (enough to offset 2 000+ flights from London to Paris) per year.

4

Page 5: SMARTONLINE 3-PHASE UPS SYSTEMS - Anixter Lite/Brochures... · SMARTONLINE ™ 3-PHASE UPS SYSTEMS ... External Battery Cabinet 80 kVA UPS System 60 kVA Load 20 kVA ... saving 1-to-1

Convenient communication and management

features allow you to monitor power

conditions, receive automatic alerts and control

SmartOnline E3 Series UPS Systems with

drift-proof digital precision from any distance.

• CONTACTCLOSUREINTERFACE

Connects to an Emergency Power Off (EPO)

circuit for emergency UPS system shutdown.

Also allows the UPS system to monitor

external battery cabinets and communicate

operational messages.

• RS-232SERIALPORT

Connects to a server for shutdown

commands and reporting through

PowerAlert software (included).

• ACCESSORYCARDSLOT

Optional network card (SNMPWEBCARD)

provides remote monitoring and

control. Optional environmental

sensor (ENVIROSENSE) monitors

temperature, humidity and more.

• NETWORKPOWERMANAGEMENT

You can manage UPS systems with

PowerAlert Network Management

System (included) or a third-party

network management system.

• LED/LCDCONTROLPANEL

Offers convenient push button control

and communicates operational modes,

conditions and warnings.

BATTERY CABINETSAll SmartOnline E3 Series UPS Systems can connect to external battery cabinets:

• ModelsSU20KXandSU40KXincludeinternalbatteriesanddonotrequire external battery cabinets, but external battery cabinets can be added to expandruntime.ModelSU20KXalsohasroomtoaddtwoadditional SURBC2030 internal battery packs.

• ModelsSU60KXandSU80KXdonothaveinternalbatteriesandrequirean external battery cabinet. Additional battery cabinets can be connected to expand runtime.

External battery cabinets are available in a variety of capacities. Models BP480V26B and BP480V40C support temperature-compensated charging foroptimal charge levels and increased battery lifespan. They also match the appearance and footprint of the UPS system cabinets. Larger models have heavy-gauge steel cabinets with 10-year design life batteries. SmartOnline E3 Series UPS Systems handle large battery systems with ease, providing up to 20 amps* of user-selectable charging capacity. * Varies with model.

Real-Time Power Status Consoles

POWERALERT NETWORK MANAGEMENT SYSTEM

PowerAlert allows you to manage up to 250 UPS systems from a single workstation.

MONITORING AND CONTROL

BP480V40CBP480V26B

The LED/LCD control panel provides detailed UPS status information.

The rear panel includes several communication interfaces.

Parallel Interface

RS-232 Serial Port

Accessory Card Slot

Contact Closure Interface

5

Page 6: SMARTONLINE 3-PHASE UPS SYSTEMS - Anixter Lite/Brochures... · SMARTONLINE ™ 3-PHASE UPS SYSTEMS ... External Battery Cabinet 80 kVA UPS System 60 kVA Load 20 kVA ... saving 1-to-1

6

ORDERING INFORMATIONMODEL OUTPUT CAPACITY NOMINAL INPUT/OUTPUT VOLTAGE BATTERY CONFIGURATION

SU20KX 20kVA/16kW 220/380,230/400or240/415VAC (3Ø,4-wire+ground,wye)

Internalbatteries;roomfortwoadditionalSURBC2030internalbatterypacks;externalbatterycabinetoptional.

SU40KX 40kVA/32kW 220/380,230/400or240/415VAC (3Ø,4-wire+ground,wye)

Internalbatteries;externalbatterycabinetoptional.

SU60KX 60kVA/48kW 220/380,230/400or240/415VAC (3Ø,4-wire+ground,wye)

Nointernalbatteries;externalbatterycabinetrequired.

SU80KX 80kVA/64kW 220/380,230/400or240/415VAC (3Ø,4-wire+ground,wye)

Nointernalbatteries;externalbatterycabinetrequired.

EXTERNALBATTERYCABINETS (Hardwire connection. Multiple cabinets can be daisy-chained.)

BP480V26B +/-240VDCexternalbatterycabinet.Supportstemperature-compensatedbatterychargingforoptimalchargelevelsandincreasedbatterylifespan.MatchesappearanceandfootprintofUPSsystemcabinet.

BPE480VB Empty+/-240VDCexternalbatterycabinet(similartoBP480V26Bwithoutbatteries).Requires40user-suppliedbatteries(12VDC/26Ah).Includeswiringandfuses.MatchesappearanceandfootprintofUPSsystemcabinet.

BP480V40C +/-240VDCexternalbatterycabinet.Supportstemperature-compensatedbatterychargingforoptimalchargelevelsandincreasedbatterylifespan.MatchesappearanceandfootprintofUPSsystemcabinet.

BPE480VC Empty+/-240VDCexternalbatterycabinet(similartoBP480V40Cwithoutbatteries).Requires40user-suppliedbatteries(12VDC/40Ah).Includeswiringandfuses.MatchesappearanceandfootprintofUPSsystemcabinet.

BP480V55 +/-240VDCexternalbatterycabinet.Heavy-gaugesteelcabinetwith10-yeardesignlifebatteries.

BP480V78 +/-240VDCexternalbatterycabinet.Heavy-gaugesteelcabinetwith10-yeardesignlifebatteries.

BP480V103 +/-240VDCexternalbatterycabinet.Heavy-gaugesteelcabinetwith10-yeardesignlifebatteries.

BP480V140 +/-240VDCexternalbatterycabinet.Heavy-gaugesteelcabinetwith10-yeardesignlifebatteries.

SURBC2030 240VDCinternalbatterypackforSU20KX.

WALL-MOUNTEDEXTERNALMAINTENANCEBYPASSPANELSWITHKEYEDSAFETYINTERLOCKSYSTEM

SU20KMBPK MaintenancebypasspanelforSU20KXonly.Keyedsafetyinterlocksystempreventssequenceofoperationerrors.

SU40KMBPKX MaintenancebypasspanelforSU40KXonly.Keyedsafetyinterlocksystempreventssequenceofoperationerrors.

SU60KMBPKX MaintenancebypasspanelforSU60KXonly.Keyedsafetyinterlocksystempreventssequenceofoperationerrors.

SU80KMBPKX MaintenancebypasspanelforSU80KXonly.Keyedsafetyinterlocksystempreventssequenceofoperationerrors.

WALL-MOUNTEDPARALLELDISTRIBUTIONPANELS (Required for parallel connection of UPS systems.)

SUPT20KX ParalleldistributionpanelforparallelconnectionofSU20KXmodelsonly.

SUPT40KX ParalleldistributionpanelforparallelconnectionofSU40KXmodelsonly.

SUPT60KX ParalleldistributionpanelforparallelconnectionofSU60KXmodelsonly.

SUPT80KX ParalleldistributionpanelforparallelconnectionofSU80KXmodelsonly.

POWERMANAGEMENTACCESSORIES

SNMPWEBCARD AddsEthernetnetworkinterfacetoUPSsystemforremotemonitoringandcontrolviaSNMP,Webortelnet.

ENVIROSENSE Monitorstemperatureandhumidity.Monitorsuptothreeadditionalsensorsviacontactclosureinterface. RequiresSNMPWEBCARD.

WARRANTIESANDSERVICES

Sitesurveyservices,start-upservices,preventivemaintenanceservices,extendedwarrantiesandon-sitewarrantiesareavailable. Visitwww.tripplite.comorcontactyourTrippLitesalesrepresentativeformoreinformation.

COMPACT FOOTPRINTEach SmartOnline E3 Series UPS System packs enough power for multiple

racks of equipment into a compact footprint, saving valuable data center

floor space for critical systems and cooling. Wall-mounted distribution and

bypass panels do not require additional floor space.

Page 7: SMARTONLINE 3-PHASE UPS SYSTEMS - Anixter Lite/Brochures... · SMARTONLINE ™ 3-PHASE UPS SYSTEMS ... External Battery Cabinet 80 kVA UPS System 60 kVA Load 20 kVA ... saving 1-to-1

INP

UT

MODEL SU20KX SU40KX SU60KX SU80KX SU30K3/3INT

NOMINAL VOLTAGE User-Selectable:220/380,230/400or240/415VAC(3Ø,4-wire+ground,wye)

VOLTAGE RANGE FullLoad:173/300–276/477VAC(-25% / +20% @ 230/400 VAC)

≤70%Load:120/208–276/477VAC(-48%/+20%@230/400VAC)176/304– 288/499VAC

THDi (Full Load) <4%

POWER FACTOR (On-line, Full Load) >0,99 >0,95

FREQUENCY (Auto-Selectable) 50/60Hz

FREQUENCY TOLERANCE ±5% ±3%

NOMINAL CURRENT

(@380/400/415VAC,PerPhase)26/25/24A 53/50/48A 79/76/73A 105/101/97A 45/43/41A

OU

TPU

T

CAPACITY (VA) 20000VA 40000VA 60000VA 80000VA 30000VA

CAPACITY (Watts) 16000W 32000W 48000W 64000W 24000W

POWER FACTOR 0,8PerPhase

NOMINAL VOLTAGE User-Selectable:220/380,230/400or240/415VAC(3Ø,4-wire+ground,wye)

FREQUENCY 50/60Hz±0,05Hz 50/60Hz±0,1Hz

NOMINAL CURRENT

(@380/400/415VAC,PerPhase)30/29/28A 61/58/56A 91/87/83A 121/116/111A 46/43/42A

WAVEFORM (On-line or Battery) PureSineWave

THD (Linear Load) ≤3%

VOLTAGE REGULATION (Static) ±1% ±2%

OVERLOAD CAPACITY ≤125%for10minutes;≤150%for60seconds ≤125%for60sec; ≤150%for30sec

BR

EA

KE

RS

RECTIFIER (3-Pole, 600 VAC) 50A 75A 125A 150A 63A

BYPASS (3-Pole, 600 VAC) 50A 75A 125A 150A 63A

RESERVE (3-Pole, 600 VAC) 50A 75A 125A 150A -

OUTPUT (3-Pole, 600 VAC) 50A 75A 125A 150A -

BATTERY (Negative Pole, 600 VDC) 60A 120A 160A 220A -

GE

NE

RA

L

STANDARD INTERFACE LED/LCDControlPanel,RS-232,ContactClosure,EPO(LocalandRemote) Sameasleft,plusAS/400.

OPTIONAL INTERFACE SNMPWEBCARD,ENVIROSENSE,RELAYIOCARD

UPS TOPOLOGY TrueOn-line,DoubleConversion;Voltage/FrequencyIndependent(VFI-SS-111)Operation; ComplieswithEUDirectives(EN62040-3)

AGENCY APPROVALS CE(EN62040-1-1,EN62040-2,EN62040-3,IEC61000-4-2,IEC61000-4-3, IEC61000-4-4,IEC61000-4-5,IEC61000-4-6),RoHS

CE(Sameasleft),GOST,SASO

EFFICIENCY NormalMode:Upto94%/EconomyMode:Upto97% Upto93%

TRANSFER TIME (Normal Mode) 0ms

AMBIENT OPERATING TEMPERATURE 0°Cto40°C(32°Fto104°F)

ELEVATION 0to3000m(0to10000ft)

HUMIDITY (Non-Condensing) ≤90% ≤95%

AUDIBLE NOISE (@ 1 m) <70dBA <65dBA

TYPICAL RUNTIME* (Half/Full Load) 13/5,5+min(InternalBatteries)

13/5,5+min(InternalBatteries)

14/5,5+min(WithBP480V26B)

10/3,5+min(WithBP480V40C)

13/5+min(InternalBatteries)

DIMENSIONS (Power Module)

Height 1165mm(45,9in) 1165mm(45,9in) 1165mm(45,9in) 1165mm(45,9in) 897mm(35,3in)

Width 520mm(20,5in) 520mm(20,5in) 520mm(20,5in) 520mm(20,5in) 490mm(19,3in)

Depth 855mm(33,7in) 855mm(33,7in) 855mm(33,7in) 855mm(33,7in) 940mm(37,0in)

UNIT WEIGHT** (Power Module) 267kg(589lb) 412kg(908lb) 210kg(463lb) 244kg(538lb) 284kg(627lb)

SHIPPING WEIGHT** (Power Module) 335kg(739lb) 480kg(1058lb) 278kg(613lb) 312kg(688lb) 324kg(715lb)

*Runtimevarieswithload,batteryconditionandotherfactors.Runtimecanbeextendedbyconnectingadditionalinternalbatteries(modelsSU20KXandSU30K3/3INTonly)or external battery cabinets, sold separately. ** WeightincludesinternalbatteriesformodelsSU20KX,SU40KXandSU30K3/3INT.

TECHNICAL SPECIFICATIONS

7

Page 8: SMARTONLINE 3-PHASE UPS SYSTEMS - Anixter Lite/Brochures... · SMARTONLINE ™ 3-PHASE UPS SYSTEMS ... External Battery Cabinet 80 kVA UPS System 60 kVA Load 20 kVA ... saving 1-to-1

RELIABLE OPERATIONSmartOnline T3 Series UPS Systems protect your equipment from power problems,

including surges, line noise, harmonic distortion, electrical impulses, frequency variations,

brownouts, overvoltages and blackouts. On-line operation continually transforms AC

input power into filtered DC power, then resynthesizes it into precision-regulated AC

output with a pure sine wave. Reliable backup power with zero transfer time to battery

keeps equipment operating safely through shorter power failures and allows time to

shut down or switch to generator power during longer outages. Fault-tolerant bypass

features keep your equipment powered at all times—even if the UPS system requires

maintenance, repair or replacement.

VERSATILE BATTERYSYSTEMSmartOnline T3 Series UPS Systems have an expandable, hot-swappable battery system

withconvenientfront-panelaccess.ModelSU30K3/3INTincludesthreeinternalbattery

packs and has room to add one additional SURBC2030 battery pack. Runtime can also

be expanded with external battery cabinets. Each SUBF2030 external battery cabinet

has room for up to four SURBC2030 battery packs.

SMARTONLINE T3 SERIES UPS SYSTEMS

Expand battery backup runtime by installing additional internal battery packs and/or

external battery cabinets.

SU30K3/3INT

SUBF2030 External Battery Cabinet

SURBC2030 Internal Battery Pack

+ _+ _

+ _OPEN

OPEN OPEN

OPEN OPEN

ORDERING INFORMATIONMODEL OUTPUT CAPACITY BATTERY CONFIGURATION

SU30K3/3INT 30kVA/24kW Includesthreeinternalbatterypacks;roomforoneadditionalSURBC2030batterypack.

BATTERYEXPANSION (Multiple battery cabinets can be daisy-chained.)

SURBC2030 240VDCinternalbatterypackforSmartOnlineT3UPSSystemsandSUBF2030externalbatterycabinets.

SUBF2030 Externalbatterycabinet.RequiresSURBC2030batterypacks(uptofourpercabinet),soldseparately.

BP240V99 240VDCexternalbatterycabinetwith10-yeardesignlifebatteries.

BP240V120 240VDCexternalbatterycabinetwith10-yeardesignlifebatteries.

BP240V1207C 240VDCexternalbatterycabinetwith10-yeardesignlifebatteries.Built-inbatterycharger.

BP240V150 240VDCexternalbatterycabinetwith10-yeardesignlifebatteries.

BP240V1507C 240VDCexternalbatterycabinetwith10-yeardesignlifebatteries.Built-inbatterycharger.

WALL-MOUNTEDEXTERNALMAINTENANCEBYPASSPANELSWITHKEYEDSAFETYINTERLOCKSYSTEM

SU30KMBPK Maintenancebypasspanelfor30kVAmodels.Keyedsafetyinterlocksystempreventssequenceofoperationerrors.

POWERMANAGEMENTACCESSORIES

SNMPWEBCARD AddsEthernetnetworkinterfacetoUPSsystemforremotemonitoringandcontrolviaSNMP,Webortelnet.

ENVIROSENSE Monitorstemperatureandhumidity.Monitorsuptothreeadditionalsensorsviacontactclosureinterface. RequiresSNMPWEBCARD.

RELAYIOCARD Programmablecontactclosureaccessorycardwithsixoutputcontactsandoneinputcontact.

WARRANTIESANDSERVICES

Sitesurveyservices,start-upservices,preventivemaintenanceservices,extendedwarrantiesandon-sitewarrantiesareavailable. Visitwww.tripplite.comorcontactyourTrippLitesalesrepresentativeformoreinformation.

ABOUT TRIPP LITESince 1922, Tripp Lite has established a global reputation for qualitymanufacturing, superior value and excellent service. Tripp Litemakes more than 1000 products to power, protect and connectelectronic equipment, including UPS systems, replacement batteries,power distribution units, rack systems, surge suppressors, KVMswitches, cables, laptop accessories, power strips and inverters. Learnmoreatwww.tripplite.com.

Copyright © 2009 Tripp Lite. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.

Specifications are subject to change without notice. Photos may differ slightly from final products.

20080224095-2917

TRIPP LITE WORLD HEADQUARTERS 1111W.35thStreet,Chicago,IL60609USA,+1.773.869.1212,www.tripplite.com

TRIPP LITE AMÉRICA LATINA (MIAMI) +1.305.406.2523,[email protected]• TRIPP LITE CHILE (SANTIAGO) +562.433.0301,[email protected] LITE MIDDLE EAST (DUBAI) +971.4.887.1633,[email protected]• TRIPP LITE RUSSIA (MOSCOW) +7.495.799.5607,[email protected]

TRIPP LITE BELGIUM +32.2.582.9946,[email protected]