  • Small scale electrochemical disinfection system with specially coated electrodesC. Sousa, K.M. Śmiech, A. W. Jeremiasse, L.L.F. Agostinho

    Athens, September 2016

    1

  • Outlook

    • Background: (Electrochemical) water disinfection

    • Methods• Experimental setup• Results:

    Disinfection efficiency Produced disinfectants Disinfection byproducts and heavy metals

    • Summing up

    2

  • Water disinfectionImportant for preventing the spreading of waterborne diseases

    1Martinez-Huitle, C., & Brillas, E. (2008) Electrochemical alternatives for drinking water disinfection. Angewandte Chemie

    International Edition 47 (11), 2-10

    3

    Methods1:

    • Chemical e.g. Cl2, ClO, O3• Physical e.g. UV• Physical-chemical e.g. electrochemical

    Electrochemical disinfection efficiency:• Electrolyte• Current (density)• Electrode material

    • BDD• MMO

  • Methods

    • 2 electrochemical cells• 2 MMO types (Ru, Ir, Ti)

    ON2012 ON2038

    • Total flowrate = 4 m3 h-1

    • Cl- concentration = 49 mg L-1

    • Disinfection efficiency for 3 bacteria and 1 virus E.coli S. epidermidis R. terrigena bacteriophage MS2

    • Analysis for THM• Analysis for heavy metals

    4

  • Experimental setup

    5

  • 6,19

    0

    6,22

    0

    6,16

    0

    6,01

    0

    6,19

    0

    6,39

    0

    6,22

    0

    6,43

    0

    6,36

    00

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    IN OUT IN OUT IN OUT

    Log

    (CFU

    /mL)

    E. coli S. epidermidis R. terrigena30 min.60 min0 min 30 min

    Disinfection efficiency

    Bacteria*: > log 6 disinfection

    6

    Virus**: log 3 – log 5 disinfection

    * Method: Heterotrophic plate count. Standard Methods for the Examination of Water and Wastewater (APHA).

    ** Method: ISO 10705-1:1995 Detection and enumeration of bacteriophages. Part 1: enumeration of F-specific RNA bacteriophages.

    5,78

    1,16

    5,78

    0,78

    5,72

    0,00

    5,62

    2,69

    5,69

    2,27

    6,31

    2,54

    0

    2

    4

    6

    8

    10

    12

    14

    IN OUT IN OUT IN OUT

    Log(

    PFU

    /mL)

    MS2 cell 2038 MS2 cell 2012

    0 min 30 min 60 min

  • Produced disinfectants

    *Method: ISO 7393/1:1998 Water quality -- Determination of free chlorine and total chlorine -- Part 1: Titrimetric method using N,N-diethyl-1,4-phenylenediamine.

    **Method: H. Bader & J. Hoigné (1981) Determination of ozone in water by the indigo method. Water Research 15(4), 449-456

    7

    IN OUT 2012 OUT 2038 range

    Free Cl (mg L-1)* 0 0,37 1,38 0,5 – 3

    O3 (mg L-1)** 0 0,33 0,36 0,1 – 0,8

    Active chlorine production: > 90% Coulombic efficiency

  • Disinfection byproducts and heavy metals

    • Total THM ~0,6 μg L-1 as AOX

  • Summing up• Small scale (2 x 2 m3 h-1) electrochemical disinfection system with specially

    coated electrodes (MMO with Ru and Ir)

    • Treatment of waters with low Cl- content (49 mg L-1) without salt addition

    9

    • Disinfection efficiency:

    • bacteria: > log 6• virus: log3 – log 5

    • Produced disinfectants included:

    • Free Cl: 0,5 – 3 mg L-1

    • O3: 0,1 – 0,8 mg L-1

    • THM: ~0,6 μg L-1 as AOX, i.e.