No Special Tools Required • handfastenedorfastenedwithapneumaticnailgun
• utilityknifeorastandardcircularsaw
• tapemeasure,prybar,tinsnips
• chalklinewithbluechalk(donotuseredchalk)
Storing the ProductForproperinstallation,theroof tilesneedtobestoredontheoriginalpalletonaflatsurface.Properstorageof theproductatthejobsiteisimportant.Theroof tilesarecamberedtoensurethatmaximumpressureistrans-ferredtotheleadingedgeof theroof tileduringinstallation.Do not double stack pallets.
Conditions:Performworkwhenexistingandforecastedweatherpermits.WorkshouldbeperformedinasafeandprofessionalmannerandwhenambientweatherconditionsarewithinthelimitsestablishedbyInSpireRoofingProducts.
Storage:InSpireroof tilesshouldnotbestoredonroof decksinsuchamannerastoover-stressand/ordamagethedeckandsupportingstructure.
Cold Weather Installation:InSpireroofingtilesshouldbestoredinoriginalpackaginginastoragefacilitywherethetemperaturemeetsorexceeds45°F.Useprotectivecoverageoverallpalletswhilebeingtemporarilystoredon-site.InSpireroof tilesmustbeconditionedatatemperaturenolowerthan45°Ffortwenty-four(24)hourspriortouse.InSpiremaybeinstalledattemperaturesaslowas32°Fbutmustbehandfastened,theuseof apneumaticgunbelow45°Fwillresultincrackingandwebbinginthefas-tenedarea.Besuretofollowthemanufacturer'sinstallationrequirementsforallunderlaymentandanyotherapplications.Complywithanyandalllocalbuildingcoderequirements.Note of Caution:Theroof tilescanbeslipperyundercertainconditionsandjobsitesafetyproceduresshouldbeenforced.
Best MATERIALS.comDiscount Warehouse
2
Exposure Requirements Class A / Class C
Roof Slope InSpire Exposure
5:12 and above 6", 6 1/2", 7, or 7 1/2"
4:12 6" or 6 1/2"
CLASS A / CLASS C Pieces/Bundle Pieces/ Square Lbs/Square Bundles/ Square Squares/ Pallet
7 1/2" exposure 25 160 240 6.4 6.25
7" exposure 25 172 258 6.88 5.8
6 1/2" exposure 25 185 278 7.4 5.4
6" exposure 25 200 300 8 5
Product Ratings and Certifications
• Hail Rating – Class IV• Fire Rating – Class A or Class C• Miami Dade TAS-100 (110 mph wind driven rain)• ICC: ESR-2745• Texas Department of Insurance #RC-155• Florida Building Code PDM 5572
InSpire StarterLbs. per piece 1
Lbs. per bundle 25
Pieces per bundle 25
Tiles per lineal foot 1
Lineal feet per bundle 25
InSpire Hip & Ridge Class A / Class CLbs. per piece 1.5
Lbs. per bundle 38
Pieces per bundle 25
Tiles per lineal foot 2 @ 6" exposure
Lineal feet per bundle 12.5
Accessory ItemsOriginal Snow Guard 100 per box, 40 lb per box
1½” Stainless Steel Ring Shank Coil Nails
7,200 pcs. per box 50 lb per box
1½” Stainless Steel Ring Shank Hand Nails 3,475 pcs. per 25 lb box
Class A Roofing Underlayment
Layfast TU35 (2 square coverage roll)
Product DescriptionTheInSpireRoofingtilesaremanufacturedfrommultiplenaturalpatterns.Theroof tilemeasuresnominally18"inheightand12"inwidth.
Center Line
Exposure Lines
18" height
12" width
6"6.5"7"
7.5"
InSpire Roofing Tile 18"
6"
Hip and RidgeWidth...........................18"–Height:.6"Exposure.....................6".-.7.5"Pre-formed.Pitch.........4/12.-.8/12. 9/12.-.14/12.
13 1/2"
12"
Starter PieceHeight:.13.½".Width:.12"
3
Fastener RecommendationsRoof tilesandstartersshouldbeappliedusingtwo2ringshankstainlesssteelorcopperfastenerswithaminimum3/8"diameterheadandminimumlengthof 1½".Corrosionresistantfastenersarealwaysrecom-mended,especiallyincoastalareas.
Thelengthof theHip&Ridgefastenershouldbeaminimumlengthof 2"overfieldtilesand3"overridgevent.
Note:Cautionshouldalwaysbeusedtoensureagainstover/underpenetrationof thefastener.Donotover-drivethefastener.Thefastenerheadshouldbecontactingthetilewithinthecenterof thenailingtargetcircle.
Allroof tileswillbeattachedwithtwofasteners,aspertheseinstructions.
Improperfasteningcancompromisetheroof systemandvoidsthemanufacturerwarranty.
Roof Decking Materials
• Minimumof 15/32"plywooddecking
• Minimum15/16"solidwooddecking
• Minimum7/16"orientedstrandboard(OSB)
MetalsMinimumrecommendationsforvalleys,eavedripstarterstrips,gableedgestripsandflashingmaterial:
• 16oz.Copper
• 26gaugecorrosionResistantMetal(StainlessSteel,ColorCladSteel,ColorCladAluminum)
Note:Thechoiceof metalsandfastenersshouldbeconsistentinmaterial.Extended-lifetypematerialsshouldalwaysbeusedforlongevityof theroof system.
InSpireRoofingProductsdoesnotwarrantymetalcomponentsandaccessories.
4
Roof VentingRoof ventilationisnecessaryforthelongevityof theroof system.Havingacoolatticinthesummerandadryatticinthewinterhelpspreventdamagetobuildingmaterials,reduceenergyconsumption,andpreventicedamming.Duringhotmonths,anun-ventedroof systemwillmaintainahighersurfacetemperature,thusshorteningthelifeof anyroof system.
Duringwintermonthsventilationisakeyfactortoremovemoisturefromtheattic.Warmmoistairinsideabuildingtravelsuptowardtheatticinwintermonths.Problemsoccurwhenwatervaporcomesincontactwithcoldbuildingmaterialsandcondensates.Thestructuralelementsof theatticwillabsorbmoistureandovertimemayleadtorottingwoodand/ormold.
Withabalancedventilationsystemsplitbetweentheridgeandsoffit,1squarefootof netfreeareaisrequiredforevery300squarefeetof atticfloorsspace.
Itisrequiredtohave1squarefootof ventilationforevery150squarefeetof atticfloorspaceif thisbalancecannotbeachieved.Ventilationisnecessaryforextendedlifeof theroof system.InSpireRoofingProductswillnotwarrantyanun-ventedroof and/orimproperlyventedroof system.
Ventilation Requirements for a Balanced Ventilation System 1.Determinethesquarefootageof theatticfloorspace;ex.Atticis45'x100'=4,500squarefeet.
2.If youwillbeabletoequallybalanceyourventilationsystem,dividetheatticfloorspaceby300.(4500÷300=15.)Theamountof NetFreeVentilationArea(NFVA)requiredinthisexampleis15squarefeet.
3.ConvertthistosquareinchesbymultiplyingtheNFVAby144.(15x144=2,160squareinchesNFVA.)
4.DividethetotalNFVAby2todeterminehowmuchventilationisrequiredintheupperandlowerportionsof theattic(2,160÷2=1,080squareinchesof NFVA.)
5.Nowdeterminehowmanyintakeandexhaustunitsarerequired,forexamplesoffitventandridgevent.
Itispermittedtousethe1/300ratiowhenatleast50percentbutnotmorethan80percentof theventilatedareaislocatedintheupperportionof theattic.If thisratiocannotbeachieved,aratioof 1squarefootNFVAforevery150squarefeetof atticfloorspacemustbeused.
5
RidgeMaster Plus Installation GuidelinesWerecommendRidgeMasterPlus11"tomeetyourventilationrequirements.MakesuretofollowthestepsbelowwheninstallingInSpireslateandRidgeMasterPlus
1.Cuta1"openingintheridgeof theroof,endallcuts12"fromoutsidewalls,chimneys,ridgecornersorhipjoints.
2.Installtilesuptotheopening,
3.Foldfeltoverlastcourseof fieldtilesorinstallmetalJchanneltopreventtheinfiltrationof finepow-dersnowbetweenkeyways.
4.InstallRidgeMasterPlususing3”roofingnails.RidgeMasterPlusshouldbeinstalled12"beyondtheslotopening.ForbestappearanceinstallRidgeMasterPlusalongtheentirelengthof theridge.
5.InstallInSpireRidgeCappiecesovertheRidgeMasterPlus,nailinginthedesignatedRidgeMasterPlusnailtargetarea.Use3"longStainlesssteelnails.
6.RidgeMasterPlushasanoverlapandanunderlapendthatinterlockwhenlaidendtoendinproperorientation.Thisunitesthe4footsectionsintoasinglestructuralintegrated,weathertightsystem.AlwaysinstallRidgeMasterPluswithoverlapendonoutsideterminalendof ridge.Youshouldalsocompleteyourridgeventwithfactoryendontheoppositeterminalendof theridge.
RidgeMasterPluswillprovide12.228squareinchesof NFVAperlinealfoot.
Underlap End
Slotted Ends
Overlap End
➤ ➤
➤➤
NAILING GUIDETo use for nail alignment when
installing cap shingles
NAILING GUIDETo use for nail alignment when
installing cap shingles➤➤
➤
➤
➤UNDERLAP
ENDS
SUPPORTED NAIL BOSSES (For nailing vent to roof
sheathing)
Blowing Snow & Bug Barrier(Must be left in)
Baffles
Slotted Interlocking Ends
➤
➤
Structural Ribs
➤
➤
➤➤
OVERLAP ENDS(Always start with Overlap end
on outside terminal end of roof )
6
TRUSS CONSTRUCTION
RIDGE POLE CONSTRUCTION
7
FASCIA VENT
ROOF TO WALL/APRON VENT
8
Spacing Between the Slate Roof Tiles1/4"spacertabsareprovidedoneveryroof tileandstartertiletoaidinmaintainingconsistenttilespacing.Thespacerswillallowforanymovementof theroof deckandexpansion/contractionof theroofingtile.
Laying Out 1/2 Roof Tiles or Cut Roof TilesWhenbeginningorfinishingwithacutpieceof slateroof tile,thecutedgeshouldbeinstalledinward.Themanu-facturededgeshouldbeinstalledtotheoutsideedgeof theroof.Thisistomaintainanacceptableroof appearancealongthegableedgeof theroof.
Thecentermarkof theroof tilecanbeusedasaguidetocuthalf-slates.Thiscanalsobeusedasaguidetokeepcoursesstraightandtoassistinmaintainingtheproper1/4"spacingwhenaligningwithintermittentverticalchalklines.DO NOT install tiles smaller than 3".Shouldtheuseof a3"tilebecomenecessary,cuttheprevioustilebackenoughtoallowa3"piecetobeused.
Roof Staging/Roof BracketsRoof pitcheswithsevereslopesrequireadditionalpreparationorstaginginordertoprovideasafeandfunc-tionalworkareawhileinstallingtheroof tile.Thestagingof theroof willrequiretheuseof roof bracketsandthesebracketsshouldbeinstalledaccordingtotheinstructionsprovidedbytheroof bracketmanufacturer.
Whenusingroof bracketswhileinstallingInSpireRoofingtiles,observethefollowingguidelines:
Installation 1.Locatethenailtargetsontheroof tileandplacetheroof bracketfastenerthroughtheroof tileto
eitherthefarrightorthefarleftof theroof tile,butonaplaneevenwiththenailtargets.
2.Installtheroof bracketandtoeboardinasafeandsecuremannerandinaccordancewiththeroof bracketmanufacture'sinstructions.
Removal 1.Lifttheroof tilethatoverlaysontheroof bracketfastener.
2.Removetheroof bracketfromthefastenerandlayitontopof theroof bracketfastener.
3.Laytheoverlayroof tileontopof thebracketandplaceapieceof woodblockingonthetopoverlaytile.
4.Ensuringthattheroof bracketispositionedovertheroof bracketfastener,hammerthewoodblockinganddrivetheroof bracketfastenerflushwiththesurfaceof theroof tile.
5.Followtheinstructionsandproceedtothenextstagingarea.
Roof Clean UpInareasof hipsandvalleyswheretherewillbeanincreasedcuttingof theroof tiles,itisrecommendedthattheseareasaresweptdailyandthecuttingsremovedfromtheroof surface.Thisisnotonlyforsafety,butalsotopreventanytrimmingsfromcloggingtheguttersanddownspouts.
9
Application Guidelines - SlateInstallation
PreparationInspectallareasof theroof surfacetobecovered.
1)Underallcircumstances,existingroofingmaterialsmustberemoveddowntothesubstratepriortoroof tileinstallation.
2)Thesurfaceareamustbeuniformlyflat,smooth,sound,cleanandfreeof irregularities.
3)Examineroof sheathingtoverifythatsheathingjointsaresupportedbyframingandblockingand/ormetalclips.
4)Verifythatsubstrateisslopedfordrainageandcompletelyanchoredtosoundframing.Anyforeignparticlesshallbecleanedfrominterlockingareastoensureproperseatingandtopreventmoistureintrusionandicedamming.Properprovisionsmustbemadeforflashingsandroof penetrations.
5)Eventhoughmetalflashingandotherspecialtyflashingsmaynotbetheresponsibilityof theroofingcontractor,theseitemsmustbeinplacepriortotheroof tileinstallation.Workbyothertradeswhichpenetratetheroof planemustbecompleted.
6)Producthandlingandstorageonaflatsurfaceisveryimportant.InSpireRoofinghasacambereddesigntoensurethatthemaximumpressureistransferredtotheleadingedgeof theroof tileduringtheinstallationprocess.Do not double stack pallets.
7)TechnicalBulletinsareavailabletoaddressspecificaspectsand/orrequirementsastheyrelatetocer-tainapplications.PleaseconsultthewebsiteorcontactInSpireRoofingforthisinformation.
Tear off and ReroofIntheeventof aroof tearoff,itisimperativethatthebuildingmaterialswilllastthelifetimeof theroofingmaterial.
Carefullyinspectdeckingmaterialtoensureitwilllastthelifeof theroof tile.RoofingovercompromiseddeckingmaterialwillvoidtheInSpireRoofingmanufacturerwarranty.
10
Underlayment 1)Iceandwaterbarrier–Ishighlyrecommendedincoldclimateareaswherewintertemperaturecan
averagebelow25degreesFtoprotectagainsticedams.Iceshieldateavesshouldextend2'beyondtheinteriorwallandinallvalleys,rakesandaroundallroof penetrations.Besuretofollowunderlay-mentmanufacturerinstallationrecommendationsandobserveyourlocalbuildingcodes.
2)ForaClassCSystem–Single-layerTypeII(No.30)Asphalt-saturatedOrganicFelt,complyingwithASTMD226:Feltshouldbepreservedunbroken,tightandwhole.Installperpendiculartoroof slopeinparallelcourses.Lapsidesof successivecoursesaminimumof 3"overeachunderlyingcourse.Lapendsaminimumof 6".Staggerendlapsbetweensucceedingcoursesatleast72".Fastenwithfeltunderlaymentnailsorequivalent.Observelocalbuildingcodes.
a)Installfeltunderlaymentonroof decknotcoveredbyself-adheringmoisturebarriermem-brane.Lapedgesof feltoverself-adheringmembranenotlessthan3"indirectiontoshedwater.Lapendsof feltnotlessthan6"overself-adheringmembrane
INSPIREROOFING TILE
INSPIRE STARTER COURSE
''T'' TYPE EDGE METAL FLASHING
OPTIONALEAVE CANT
''T'' TYPE EDGE METAL
SINGLE-LAYER 30# FELT UNDERLAYMENT
SELF-ADHERINGMOISTURE BARRIER
Feltunderlaymentshouldnotbeplacedundertheself-adheringmoisturebarriermembrane,butshouldover-lapthemembranenolessthan3".Sidelapsshouldbenolessthan6".
3)InordertoachieveaClassAFireRatingwithInSpireRoof tilesthefollowingisrequired:
a)OneLayerMBTechnologiesLayfastTU35underlaymenttocovertheentireroof deck.TU35shouldbeinstalledfollowingthemanufacturer’sinstructions.AdditionalpeelandstickunderlaymentshouldbeappliedaccordingtoyourlocalbuildingcodespriortoinstallingtheTU35.
PleasenotethatallmaterialsotherthanInSpireRoof tileswillalsohavetheirownmanufacturer’sinstructionsthatmustbefollowed.
11
General Installation
Hip Roof Layout 1)Initialstartingpointsmaybefromleftside,rightsideorcenterof theareatobeinstalled.1/4"spacer
tabsareprovidedoneveryroof tile.
2)Onemethodof startingonahiproof istolocatethecenterof theroof areatobecovered.Frombothends,positionstarterpiecesandsnapahorizontallinefromthetopsof thestartersbetweenthesetwopoints.Nextsnapaverticalperpendicularline.Thiscanbedoneeasilybymarking3ftalongtheeve,thenwhere4ftand5ftintersectwillformaperpendicularline.Aslongastheratio3:4:5staysthesamethiswillholdtrue,forexample,21:28:35.Morehorizontalandverticallinesmaybesnappedtoensuretheroof tileswillstaytrueandplumbthroughoutinstallation.Beginbyplacingastartertileontherightandleftsideof theverticallinemaintaininga¼"spacingandcontinuetobothends.
3)Thestartercourseshouldoverhangamaximumof ½"attheeaveandattherakeedge.
4)Beginthefirstcourse.Withafullroof tile,aligncenterlocatorlineof theroof tiledirectlyovertheverticalbluechalkline.Continuetobothends,maintainingthe1/4"spacingbetweenroof tiles.(Seediagrambelow.)
Blue Chalk Lines Starter Course
5'4'
3'
2nd Course 1st Course Starters
12
1)AfterinstallingtheunderlaymentandbeforeinstallingtheInSpireRoof Tiles,cleanthesurfaceof de-brisanddirt.Foreignparticlesshallbecleanedandremovedfrominterlockingareastoensureproperseatingof theproductandtopreventmoistureintrusionandicedamming.Allroof penetrationsshallbeproperlyflashedandsecuredintopositionwithdeckandunderlaymentfastenersproperlydrivenandnotprotrudingpriortoinstallingInSpireRoofingproducts.
a)Startertilesmaybeorderedpre-cut.Fulltilesmayalsobeusedonthestartercourse.
b)Thesestartertileswillbeusedasthefirstrowattheeveof theroof.
c)Tocreatetheoffsetfromcoursetocourse,usethecentermarkprovidedoneachtileandcutthetilelengthwise.Thisensuresthatthenailholesarecoveredwiththenextcoarseof tilesandnothrough-jointsareexposedtothedeck.
d)Strikethechalklineshorizontally,attheexposureleveldesired,toensurethatthetilesareinstalledstraightanduniform.Verticalchalklineswillhelpmaintainconsistencyinthekey-ways.
e)Spacertabsareprovidedoneachtiletoensureconsistentspacingbetweentiles.
f)Thereshallbenothrough-jointsfromtheroof surfacetotheunderlayment.
2)Eachsyntheticroof tileshallbefastenedwithaminimumof tworingshankroofingfasteners.Thefastenersmustbeaminimumof 1½"longand1/8"indiameterwitha3/8"diameterhead.Copperand/orstainlesssteelfastenersarerecommended.
a)Itisrequiredthatthefastenersbeplacedwithinthenailingtargetasprovidedin2placesoneachtile.Flattentilethenfasten.Fastenermustpenetratedeckingatleast3/4".
b)Cautionshouldbetakenwheretheundersideof theroof deckingisexposedtoview,suchasinanoverhangingeave,wherethenailsshouldbelongenoughtopenetratetheroof deckingbutnotsolongthattheymaybedriventhroughthedecking.
3)Beginthesecondcoursewitha6"(half tile)setbackfromthecoursebelow,thefinishededgefacingthegableedge.Alignthefullroof tilebetweenthecenterlinelocatorsfromthelowercourse.Next,adjusttheroof tileupordowntoalignthedesiredexposurelineswiththetopedgeof thelowercourse.(Seediagramatright)
Center Line
7.5" Exposure Line
Nail Targets
13
ValleysOpen Valley Design 1.Installafull36"pieceof iceandwatershieldcenteredthrutheentirevalley
2.Installminimum18"wide“W”valleyor“I”seamvalley
3.Fastenthevalleyevery2'usingmetalcleats
4.Shingleovervalleybycoveringflashingbyaminimumof 4".Makesurenottodrivefastenersfromshinglesintothevalleyflashing.
Closed Valley DesignClosedvalleysareformedbylayingroof tilestighttothevalleylineandplacingpiecesof met-alundertheroof tiles.Thelengthof theroof tileandtheslopeof theadjoiningroof sectionde-terminethesizeof themetalsheet.Eachmetalsheetshouldextend2"abovethetopof theroof tilecoursethatitwillbeappliedtosothatthesheetmaybefasteneddirectlytotheroof deck.Eachmetalsheetshouldlapthesheetbelowbyatleast3"andsetinbackof thebuttedgeof theroof tileaboveinordertobeconcealed.Eachmetalsheetshouldbewideenoughtoextend7"fromthecenterof thevalleytotheroof surface.Withaclosedvalleydesign,cutthetilesinastraightlinetofitnocloserthan3/8"againsttileof adjoiningroof slope.
SLO
PE
EXTEND SLATES 4'' [100 mm] MIN. OVER VALLEY METAL
INSPIREROOFING TILE
METAL CLIP (APPROX. 2'' [50 mm] WIDE) BEND CLIP BACK OVER TO COVER FASTENERS. MIN. 2 FASTENERS PER CLIP
VALLEY UNDERLAYMENT
LAP VALLEY METAL 8'' [200 mm] MIN. AND SET IN SEALANT
VALLEY METAL 18'' [450 mm] WIDE MIN.
CONTINUOUS STRIPPING PLY ON BOTH SIDES OF VALLEY METAL
OPTION:
ALTERNATE:
FASTENER
OPEN VALLEY DESIGN
CLOSED VALLEY DESIGN
14
FlashingsFlashingsshouldbeusedaroundallroof penetrations,suchaswalls,chimneys,dormers,parapets,ventpipes,skylights,etc.Provenextendedlifematerialsarecopper,lead,andstainlesssteel.
NOTE:Whendissimilarmetalsareplacedincontactwithoneanother,galvaniccorrosionwillresultwhichcancauseelectropositivemetalstodeteriorate.Onewaythiscanbeavoidedisbyplacingstripsof sheetleadbetweenthetwometals.InSpireRoofingProductsdoesnotwarrantymetalcomponentsandaccessories.
Step FlashingsStepflashingsareusedoverorundertheroof coveringsandareturnedupontheverticalsurface.Stepflash-ingsshouldextendundertheuppermostrowof theroof tilethefulldepthof theroof tileoratleast4"overtheroof tileimmediatelybelowthemetal.Theverticallegof themetalshouldbeturnedupaminimumof 4"andextend4"ontheroof tilewitha3/4"hem.Flashingsshouldhaveaminimumlengthof 9"andmustoverlapaminimumof 2".
Apron (Roof to Wall) Flashing
Apronflashingisusedwhenaroof terminatestoawallcausingacoursetobecutandfacenailed.Itisin-stalledovertheshinglesandbehindsidingorcounter/capflashing.
BUILDING PAPER
SHEET METAL STEPFLASHING
SIDING TO COUNTERFLASH STEPFLASHING A MIN. 2'' [50 mm]
4'' [
100
mm
]A
PPRO
X.
INSPIREROOFING TILE
UNDERLAYMENT TURNED UP WALL
STEP FLASHING DIAGRAM
SHEET METAL APRON FLASHING WITH HEMMED EDGE
SEALANT
SHEET METAL COUNTERFLASHING
RAGGLE
UNDERLAYMENT TURNED UP WALL
SOLDERED ONE PIECE APRON FLASHING CORNERS
INSPIREROOFING TILE
APRON FLASHING DIAGRAM
15
Counter Flashing 1.Cutaminimum1"deepregletintothemasonrymaterial
2.Custombendthecounterflashingtofitintothereglet
3.Startbyinstallinglowestpiecefirstandworkupwardsforproperwaterrunoff
4.Fastenthecounterusingeitherexpandableanchorsormasonryscrews
1" DEEP REGLET
SHEET METAL COUNTER FLASHING
SHEET METALSTEP FLASHING
COUNTER FLASHING DIAGRAM
16
Vent FlashingsNormaltypeof roof ventsorflashingscanbeused.Aleadstackforplumbingpipesisrecommended.Extend-ed-lifematerialsshouldalwaysbeused.
Pitch changesInSpireRoofingtilescanbeinstalledontorollingroofswithagradualpitchchange.Someroof designshow-everhavedrasticpitchchangeswheretheuseof metalflashingisnecessary.
SHEET METAL FLASHING
SHEET METAL FLASHING
CUT INSPIREROOFING TILE
CUT INSPIREROOFING TILE
4'' [100 mm] MIN. TYP.
MIN. DOWNSLOPE FLANGE DIMENSION TO BE EQUAL TO FIELD SLATE EXPOSURE
METAL FLASHING SLEEVE
INSPIREROOFING TILE
UNDERLAYMENT TO OVERLAP UPPER FLANGE
OPTIONAL SEALANT UNDER SLATE
SOIL STACK DIAGRAM
17
Chimney SaddlesWithchimneysmorethan2'wideitisrecommendedthatacricketorsaddlebeinstalledtodivertwaterfromthebackof thechimney.
Withchimneyslessthan2'mayonlyrequireasimplepanflashing.
UNDERLAYMENT
SOLDERED ONE PIECE CORNERS
18'' [450 mm] MIN.
6'' [150 mm] MIN.
STRIPPING PLY ADHERED TO UNDERLAYMENT (SEE NOTE 3)
INSPIRE STARTER COURSE
SHEET METAL BACKER FLASHING
SHEET METAL COUNTERFLASHING
SEALANT
INSPIREROOFING TILE
STARTER COURSE OVER SHEET METAL BACKER FLASHING
INSPIRE ROOFING TILEOVER SHEET METAL BACKER FLASHING
INSPIRE ROOFING TILEUNDER SHEET METAL BACKER FLASHING
SOLDERED ONE PIECE CORNERS
INSPIRE ROOFING TILEOVER SHEET METAL STEP FLASHING
SHEET METAL BACKER FLASHING
PAN FLASHING VIEW 1 PAN FLASHING VIEW 2
SOLDERED GUSSET
SOLDERED GUSSET
CONNECTED TOSHEATHINGWITH CLEATS
CRICKET / SADDLE DESIGN
18
Snow GuardsSnowguardsarerecommendedinareasof heavysnowtopreventsnowandiceslidesfromdamaginggutters,landscape,fixtures,andforpersonalsafety.Forallroofsusethestandardthreerowpattern:Threerows24"oncenter-12"apartwiththemiddlerowstaggered12".
Hip & Ridge DetailWhenpre-formedhip&ridgeroof tilesareused,placefasteneratfastenerguidestargets.Fastenhiproof tileswith2fasteners(oneoneachside).Maintaina6"exposure.
1)Hip&RidgeRoof Tileinstallationrequirestheroof tiletobenailedorscrewedinplace.
a)Chalkastraightlinebyplacingonepieceof hipattheeaveandonenearthepeak,holdthechalklineattheedgeof thetileonthetopandbottompieces.Thiswillhelpkeepthehipstraightintheeventof acrookedhip.
b)Coverheadsof fastenerswithanadhesivesealantcompatiblewiththeroof tile.
c)PreformedRidgeRoof Tilesrequire6"exposureandrequire2"lengthfasteners.
d)Fastenerdeckpenetrationmustbeaminimumof 3/4"indepth.
Blue ChalkLine
PeakHip
Eve Hip
HIP INSTALLATION
19
Staggered coursesAstaggeredroof patternmaybemorevisuallypleasing.If theroof pitchis5/12orgreateryoumustusea61/2"exposureand51/2"fora4/12pitch.
1.Itisrecommendedthatyouchalkeverycoursewhenapplyingthismethod.
2.Afterchalkinglinessimplyplaceonetileonthelineandonetilenomorethan1"belowtheline.
6.5" CHALK LINE
1" BELOW LINE
6.5" CHALK LINE
20
Turret InstallationTurretsandconesneedcustomcutshingleswhichchangedependingontheradiusandpitch.Theycanbequitedifficulttoinstall;timeandcaremustbetakenduringinstallation.
1.Determinethetaperbychalkinglinesoriginatingatthepeak,extendingtoevespaced11-5/8"apart(thewidthof oneshingle)
2.Placetheshingleattheevebetweenthe2lines,thiswillgiveyouthepropertaperforthefirstcourse
3.Markupfromthetopof yourfirsttileyourexposure.Repeatuntilyoureachthetopof theturret.
4.Eachcoursewillhaveadifferenttaperasthepiecesgetsmallertowardsthetop.Youcannowplaceashingletoeachmarkanddeterminethetaperpercourse.
5.Besuretopayattentiontothesizeof thetiles,If thetilesgettoosmallitmaybenecessarytousealargertileandre-chalklinesatsomepoint.
6.Makesuremeasurementsareperiodicallytakenfromeveandpeaktoensurestraightcourses.
PrecautionsRoof tilesmaybeslipperywhenwetorcoveredwithfrost.Fallprotectionequipmentisrequiredwhenworkingonaroof deck.Thecontractormayconsidertheuseof toeboards.InSpireRoofingroof tilesshouldbestoredintemperaturesabove45°Fandtheambienttemperatureof theproductmustbeataminimumof 45°Fdur-inginstallationinordertoavoidwebbingand/orcrackingof theroof tiles.
Donotleavedebrisundertheroof tileswhileinstallingthatwillpreventthedesignof theroof tilefromover-lappingonthecoursebelow,thusallowingthepotentialformoisturebuildupfromwinddrivenrainand/oricedams.
Useaccessoryproductswithalifecycleasequallylong-termastheroof tiles.
TechnicalBulletinsshouldbereviewedandconsideredpriortothestartof anyproject.
METAL CAP(AFTER INSPIRE TILES APPLIED)
VERTICAL CHALK LINES
FULL WIDTH TILE
1/2 TAB WIDTH
UNDERLAYMENT