six weeksindustrialtraining 121112122416 phpapp01

39
AT BHARAT ELECTRONICS LIMITED (BEL) GHAZIABAD ON “RADAR TRANSMITTER” SUBMITTED BY HITESH MITTAL 101005021 SIX-WEEKS INDUSTRIAL TRAINING (JUNE-JULY2012)

Upload: manu-kumar-saini

Post on 06-Feb-2016

213 views

Category:

Documents


0 download

DESCRIPTION

bel summer

TRANSCRIPT

Page 1: Six Weeksindustrialtraining 121112122416 Phpapp01

ATBHARAT ELECTRONICS LIMITED

(BEL) GHAZIABADON

“RADAR TRANSMITTER”

S U B M I T T E D B YH I T E S H M I T T A L

1 0 1 0 0 5 0 2 1

SIX-WEEKS INDUSTRIAL TRAINING

(JUNE-JULY2012)

Page 2: Six Weeksindustrialtraining 121112122416 Phpapp01

CONTENTS

Bharat Electronics Limited –An OverviewRotationIntroduction to RADARIts block diagramTransmitterIts mechanical descriptionIts general description

Page 3: Six Weeksindustrialtraining 121112122416 Phpapp01

BEL-An Overview

It was founded in 1954.Founded as a public Sector Enterprise under the

administrative control of Ministry of Defence as the fountainhead to supply and manufacture electronics components and equipments.

Today BEL’s infrastructure is spread over nine locations with 29 production divisions having ISO 9001/9002 accredition.

Page 4: Six Weeksindustrialtraining 121112122416 Phpapp01

BEL-An Overview

CORPORATE MOTTO-“Quality,Technology and Innovation.”

• CORPORATE MISSION-• To be the market leader in Defence

electronics and in other chosen fields and products.

Page 5: Six Weeksindustrialtraining 121112122416 Phpapp01

BEL-An Overview

CORPORATE OBJECTIVES-To become a customer driven company.To achieve growth in operation commensurate

with the growth of professional electronic industry in the country.

To generate internal resources for financing the investments.

In order to meet the nation’s strategic needs,to strive for self reliance by indigenization of materials and components.

Page 6: Six Weeksindustrialtraining 121112122416 Phpapp01

BEL-Ghaziabad Plant

Over the years the unit has successfully manufactured a wide variety of equipment needed for defence and civil use.

It enjoys a unique status as manufacture of IFF systems needed to match a variety of primary radars.

The operations at BEL Ghaziabad are headed by General manager with Additional/Deputy General Manager heading various divisions.

Page 7: Six Weeksindustrialtraining 121112122416 Phpapp01

1)ROTATION(brief sight to various departments)

2)RADAR TRANSMITTER

PROJECT

Page 8: Six Weeksindustrialtraining 121112122416 Phpapp01

ROTATION

TEST EQUIPMENT SUPPORT (TES)• Develops technical supports to other

departments. This includes :-Handling requests for equipments from other

departments.Storage of rejected equipments.Approval of equipments to be purchased.• Repair of equipment in case of failure.• Maintenance of equipments.

Page 9: Six Weeksindustrialtraining 121112122416 Phpapp01

ROTATION

AUTOMATION TEST EQUIPMENT (ATP)

1) Component testing-gives faults of various discrete components of a PCB.

2) Integrated Circuit-tester tests various IC’s.3) Functional testing-compares output to

decide whether the function is being performed to the desired accuracy level.

Page 10: Six Weeksindustrialtraining 121112122416 Phpapp01

ROTATION

PCB FABRICATION

• It is used to mechanically support and electrically connect electronic components using conductive pathways, tracks or signal traces etched from copper sheets laminated onto a non conductive substrate.

Page 11: Six Weeksindustrialtraining 121112122416 Phpapp01

ROTATION

WORKS ASSEMBLY

• Its main function to assemble various products ,components and instruments in particular procedure.

Page 12: Six Weeksindustrialtraining 121112122416 Phpapp01

ROTATION

QUALITY CONTROL WORKS • Its main function to ensure the quality of the

product.• It inspects all items manufactured in the factoryAfter mistake is detected –i. Observation is made.ii. Object code is given.iii. Division code is giveniv. Change code is preparedv. Recommended action is taken

Page 13: Six Weeksindustrialtraining 121112122416 Phpapp01

RADAR

INTRODUCTION

Page 14: Six Weeksindustrialtraining 121112122416 Phpapp01

RADAR

RADAR-Radio detection and Ranging.

FUNCTIONS Measurement of target angles as its primary

function. Measurement of Doppler velocity and

discrimination of a desired target from background noise and clutter is a prerequisite to detection and measurement.

Page 15: Six Weeksindustrialtraining 121112122416 Phpapp01

Sign conventionsThe Doppler frequency is negative (lower frequency, red shift) for objects receding from the radarThe Doppler frequency is positive (higher frequency, blue shift) for objects approaching the radar

These “color” shift conventions are typically also used on radar displays of Doppler velocity

Blue: Toward radar

Red: Receding from radar

Page 16: Six Weeksindustrialtraining 121112122416 Phpapp01

BLOCK DIAGRAM

Page 17: Six Weeksindustrialtraining 121112122416 Phpapp01

RADAR

Operates in S –band.Capable of track while scan (TWS) mode of

airborne targets upto 130 km.It employs multibeam coverage to in the

receiving mode to provide for necessary discrimination.

The antenna is mechanically rotated in azimuth to provide 360 degree coverage.

It is designed to play the role of medium range surveillance.

Page 18: Six Weeksindustrialtraining 121112122416 Phpapp01

TRANSMITER

SALIENT FEATURES-

It is of coherent MOPA type.It operates in S –band using TWT as a final

amplifier.It is used to amplify low RF power signal to high

power RF signal as demanded by the system.TWT dissipates large amount of energy therefore

it is subjected to both air and liquid cooling.

Page 19: Six Weeksindustrialtraining 121112122416 Phpapp01

Input output diagram of Transmitter

3-phase,400V,50Hz

3-channel liq cooling in

3-channel liq cooling out

Air cooling in

SP signals

Air cooling out

Dry air

BIT0BIT1

PRETRGGRID PULSE

RF outROHINITRANSMITTER

RF input

System status

RF PULSE

Page 20: Six Weeksindustrialtraining 121112122416 Phpapp01

OPERATION MODES OF TRANSMITTER

a) OFF : All subsystems switched OFFb) Cold Standby : Only LVPSU’s, TWT heater and Grid

biases are switched ON. No High Voltage applied.

c) Hot Stand By : High Voltages applied, No RF and No grid Pulsing.

d) Transmission : RF power delivered to Antenna / matched Load.

i) Full Power mode : Full RF Power delivered to the Antenna ii) Reduced Power mode : The transmitter is operated at 1/10 of its full

power based on the selection by the user.iii) Fail safe mode : A low power at required duty

delivered to antenna through solid state Power amplifier when liquid cooling fails.

Modes are selected by the operator.

Page 21: Six Weeksindustrialtraining 121112122416 Phpapp01

MECHANICAL DESCRIPTION

Page 22: Six Weeksindustrialtraining 121112122416 Phpapp01

3-TRACK CONFIGURATION Control Rack Monitoring panel Control panel Synoptic panel CPC Inverter   High Voltage Rack FDM (Solid state Switching) Cathode Assembly Collector Assembly Blower Unit Heater Unit   Microwave Rack TWT RF Plumbing RF Drive Unit SSPA ION Pump Controller 

Page 23: Six Weeksindustrialtraining 121112122416 Phpapp01

1.)CONTROL RACK

Page 24: Six Weeksindustrialtraining 121112122416 Phpapp01

CONTROL RACK Control Rack provides the protection controls and indications. As mentioned

before, this rack is divided in five sections according to their functions. Monitoring Panel  The Monitoring Panel provides monitoring ports for measuring of trigger

signals to the transmitter, liquid cooling status, collector and cathode Inverter currents and bridge voltages. It provides an emergency switch OFF button and digital displays for collector and cathode voltages.

 

Control Panel  The control panel controls the power supplies of various units such as the

fans, heater, LVPSU, Inverter, Modulator, RF Drive Unit and SSPA. The hour meters for filament, EHT and RF are also placed on the control panel.

 

Page 25: Six Weeksindustrialtraining 121112122416 Phpapp01

CONTROL RACKSynoptic Panel  Synoptic Panel is located above the Control and Protection Circuit

(CPC). It indicates the faults and status signals generated by CPC. Green LEDs represent status signals while Red LEDs represent faults. Audio alarms are also provided to indicate faults.

 Control and Protection Circuits The CPC ensures the sequential switching ON/OFF of the

transmitter, continuous monitoring and interlocking of various parameters, detection and indication of errors.

Inverter  The Inverter is the main functional block of the

(cathode/collector) HV Power supplies. A number of indicators are placed on the front panel of the Inverter unit.

Page 26: Six Weeksindustrialtraining 121112122416 Phpapp01

2.)HIGH VOLTAGE RACK

This is central block of the transmitter, where cabins for HV Cathode and Collector are assembled. Above this is a FDM block where all the cards are installed and insulated from the transmitter that works on HV.

Page 27: Six Weeksindustrialtraining 121112122416 Phpapp01

3.)MICROWAVE RACK

Page 28: Six Weeksindustrialtraining 121112122416 Phpapp01

MICROWAVE RACKThe microwave unit consists of the following functional

assemblies:  1. Low power amplifier [RF drive unit]2. High power TWT amplifier3. RF Plumbing, Wave-guide switch & dummy load4. Solid state power amplifier (2 kW) for low power transmission

mode5. TWT ion pump supply6. Resistive TWT anode divider7. Microwave power measurement circuits 8. Air cooling components

Page 29: Six Weeksindustrialtraining 121112122416 Phpapp01

MICROWAVE RACKLow Power Driver for TWT (RF Driver)  Low Power amplifier stage (RF Driver) amplifies pulsed RF

signal from 1mW (0dBm) to few Watts power, necessary to drive the TWT amplifier.

High Power Microwave Stage  High Power Microwave consists of mainly TWT, which

amplifies the pulsed RF signal received from the RF Driver of few watt power to a level of 120 -185 KW at the TWT output followed by High Power RF plumbing components.

Page 30: Six Weeksindustrialtraining 121112122416 Phpapp01

MICROWAVE RACKHigh Power RF stage consists of:

Traveling Wave Tube (TWT)Ferrite CirculatorDual Directional Coupler (DDC)High Power dummy load Wave guide channelWave guide switch

Page 31: Six Weeksindustrialtraining 121112122416 Phpapp01

MICROWAVE RACKA traveling-wave tube (TWT) is a

specialised vacuum tube that is used in electronics to amplify radio frequency (RF) signals to high power, usually as part of an electronic assembly known as a traveling-wave tube amplifier (TWTA).

The bandwidth of a broadband TWT can be as high as one octave, although tuned (narrowband) versions exist, and operating frequencies range from 300 MHz to 50 GHz. The voltage gain of the tube is on the order of 70 decibels.

Page 32: Six Weeksindustrialtraining 121112122416 Phpapp01

MICROWAVE RACK Ferrite circulator  Ferrite circulator is used to protect the microwave tube against failure /

damage due to reflected power in case of excess VSWR at Antenna input port. The Four port Ferrite circulator type is used as an isolator. 

Dual Directional Coupler  High Power Dual Directional Coupler (DDC) is used for measuring the

Transmit Power and reflected power. If reflected power exceeds the specified limit of 2:1 VSWR, video signal is generated to cut-off the RF drive through control and protection unit.

  High power dummy load• High power dummy load is used to test the transmitter with out connecting

the antenna during stand alone testing.  Wave-guide Channel To connect all the components in the required form, flexible sections, E-

bends, H-bends and straight sections are used. Standard W/G sections are being used for this purpose.

Page 33: Six Weeksindustrialtraining 121112122416 Phpapp01

GENERAL DESCRIPTION

RF DRIVER TWT

FIL., GRID, CATHODE, COLLECTOR SUPPLY

COUPLER

FWD AND RFLECTED PWR MONITOR

LIQUID COOLING

TOANTENNA

SSPA

W/GSWITCH

Page 34: Six Weeksindustrialtraining 121112122416 Phpapp01

GENERAL DESCRIPTION The Transmitter amplifies the pulsed RF signal from few Watts to

many KW while maintaining the phase noise (additive noise) to prescribed margin as demanded by the system. In addition, a Solid State Power Amplifier (SSPA) is provided, as a stand by option, to ensure fail-safe mode, in case of failure of liquid coolant.

  It employs a Traveling Wave Tube as final power amplifier. Low

power amplifier stage (RF Driver) amplifies pulsed RF signal from 1mW to few W which is necessary to drive the TWT amplifier. 

This is followed by an isolator. The isolator protects the transistor power amplifiers against excessive reflections from TWT. The signal is thereafter passed through a DC, a RF switch and an attenuator to cater for the three transmission modes. The sampled output of the DC is used for monitoring the input RF signal to the TWT.

Page 35: Six Weeksindustrialtraining 121112122416 Phpapp01

GENERAL DESCRIPTION The RF Driver output is given to the input of TWT, which amplifies

the pulsed RF signal from few Watts to a level of many kW at the TWT output. High power RF plumbing components are connected at the output of TWT.

  The TWT output is given to an arc detector followed by a ferrite

circulator. The Ferrite circulator is used to protect the microwave tube against failure /damage due to reflected power in case of excessive VSWR at Antenna input port. The output of

  Ferrite Circulator is given to High Power Dual Directional Coupler

(DDC), which is used for measuring the transmitted and reflected power. If reflected power exceeds the specified limit of VSWR, a video signal is generated to cut off the RF drive through control and protection circuit.

Page 36: Six Weeksindustrialtraining 121112122416 Phpapp01

GENERAL DESCRIPTIONControl and Protection Circuit ensures the sequential

switching ON of the transmitter, continuous monitoring and interlocking of various parameters, detection and indication of errors.

All these are achieved by dedicated hardware and software.

Synoptic Panel consists of LEDs, switches and LCD display. LEDs are used to show the status of the transmitter. They also show the fault, if any, in the transmitter. The LCD display, mounted on Synoptic panel, is used to show the value of cathode voltage & current, collector voltage and current. It also displays the Filament voltage and current, Grid + ve and -ve voltages and RF forward power.

Page 37: Six Weeksindustrialtraining 121112122416 Phpapp01

GENERAL DESCRIPTION The Inverter unit converts the incoming ac supply to DC and

then converts the DC to high frequency AC (Pulse width controlled square wave) operating at 20 kHz. The output of the Inverter unit is given to HV rack for generation of Cathode and Collector voltages of the TWT amplifier.

 High Voltage Power Supply unit (HVPSU) is used to supply

high voltage to collector and cathode of the TWT. The Floating Deck Modulator (FDM) unit generates filament

voltage with surge current protection and also generates grid +ve and grid -ve voltages. Switching of grid voltage as per pulse width and PRF requirements are also provided by FDM.

Page 38: Six Weeksindustrialtraining 121112122416 Phpapp01

GENERAL DESCRIPTIONCooling Unit is used to cool the various

components of the transmitter. The TWT, High Power Ferrite Isolator, high Voltage Power supplies and RF dummy load are cooled with de-ionized water and ethylene glycol mixture.

 Forced air-cooling is employed to cool other

components using ambient air which is filtered to ensure dust free air. The Dry Air unit ensures that the wave guide is at all times pressurized and dry.

 

Page 39: Six Weeksindustrialtraining 121112122416 Phpapp01

THANK YOU