sivacon switchboards

28
www.siemens.com/sivacon The Low-Voltage Switchboard that Sets New Standards Safety in its Perfect Form – SIVACON S8

Upload: andrei-daniel

Post on 07-Oct-2014

158 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Sivacon Switchboards

www.siemens.com/sivacon

The Low-Voltage Switchboard that Sets New StandardsSafety in its Perfect Form – SIVACON S8

Page 2: Sivacon Switchboards

Master Your Power RequirementsWith our Systematic Support

As an essential component of the “Totally Integrated Power” concept by Siemens, we provide integrated power distribution solutions from the medium-voltage supply right to the outlet. Communication capability and software modules allow for efficient connection to industrial and building automation, which bears further significant saving potentials. With our systematic support, you no longer need to worry about your power distribution. Our portfolio comprises the following ranges:

SIMATIC powercontrol for comprehensive power management

SIVACON power distribution boards and motor control centers

SIVACON busbar trunking systems

SENTRON switching and protection devices

High power volumes, countless consumers, maximum availability around the clock?

No matter how turbulent your power distribution requirements – our integrated

low-voltage power distribution products and systems support you by competently

mastering your power requirements in all situations and throughout your power

distribution systems’ entire service life. Our matched and powerful components help

you to considerably reduce your investment costs and risks. You will benefi t from the

components’ modularity and intelligence over the complete utilization period and

thus keep a tight control of your operating costs while exploiting maximum system

availability.

2

Page 3: Sivacon Switchboards

SIVACON S8The Attractive Low-Voltage Switchboard

High-quality industrial design for precise integration in modern room concepts

Space-saving erection surfaces from 400 x 500 mm

Variable top or rear busbar positions

Combination of different installation systems in one section

Flexible adjustment of the form of internal separation to individual requirements

Easy subsequent door hinge con-version thanks to universal hinge

Ventilation system featuring a high effi ciency degree and maintenance advantages

Cable/busbar connection from the top, bottom or rear

Numerous options, manifold advantages

Maximum system safety thanks to type-tested standard modules (TTA)

Maximum personnel safety thanks to arc-resistant locking system

Labeling system

Hinge/locking system

Ventilation system Base

Pivoted lever lock

Design side panel

Ventilation roof

All details of the new generation of switchboards merge in shape and function

Extensively tested, safely distributedSIVACON S8 is a type-tested low-voltage switchgear and controlgear assembly (TTA) whose physical properties were both dimensioned for operation as well as for fault situations in the test bay. Final type tests in accordance with IEC 60439-1 and DIN EN 60439-1 guarantee maximum operational and personnel safety.

Moreover, already the standard SIVACON version features a test proof under arcing conditions in accordance with IEC 61641 and VDE 0660 Part 500, Supplement 2. This degree of safety sets new standards.

Maximum safety and an appealing design are ideally combined in an efficient solution: with SIVACON® S8, the new generation of switchboards for consistent and simple power distribution applications up to 7000 A in functional and industrial buildings and in the process industry. In addition to manifold features for improved personnel and system protection, the switchboards’ new design opens up completely new application areas.

3

Page 4: Sivacon Switchboards

4

Installation systems

Functions

Rated current In

Connection position

Section width (mm)

Internal separation

Busbar position

Circuit breaker system

Fixed-mounted design

Withdrawable design

Incoming feeder

Outgoing feeder

Coupler

Up to 6300 A

Front and rear

400/600/800/1000/1400

Form 1, 2b, 3a, 4b

Rear/top

Universal installation system

Fixed-mounted design with compartment doorsPlug-in 3NJ6 in-line designWithdrawable unit design, removable unit design

Cable feedersMotor feeders

Up to 630 AUp to 250 kW

Front and rear

600*/1000/1200

Form 2b, 3b, 4a, 4b

Rear/top

3NJ6 in-line system

Plug-in 3NJ6 in-line design

Cable feeders

Up to 630 A

Front

1000/1200

Form 3b, 4b

Rear/top

* not with 3NJ6

Page 5: Sivacon Switchboards

5

Fixed-mounted system

Fixed-mounted design with front covers

Cable feeders

Up to 630 A

Front

1000/1200

Form 1, 2b, 4a, 4b

Rear/top

3NJ4 in-line system

Fixed-mounted design

Cable feeders

Up to 630 A

Front

600/800

Form 1, 2b

Rear

Reactive power compensation

Fixed-mounted design

Central compensation of reactive power

Non-choked up to 600 kvarChoked up to 500 kvar

Front

800

Form 1, 2b

Rear/top/without

Page 6: Sivacon Switchboards

6

With its compact design featuring a section width of only 400 mm, SENTRON 3WL is perfectly suited for the nominal current range up to 1600 A

The incoming and outgoing feeder and coupler sections of the circuit

breaker system are equipped with SENTRON® 3WL air circuit breakers in

withdrawable or fixed-mounted design or, alternatively, with SENTRON 3VL

molded-case circuit breakers. As numerous consumers are generally

installed downstream these sections, they are particularly important for

the power distribution board’s long-term operational and personnel safety.

SIVACON compactly and safely meets these requirements with the circuit

breaker system components.

Outstanding User-Friendliness:

Circuit Breaker System

Page 7: Sivacon Switchboards

Duis autem vel eum iriure dolor in hendrerit in vulputate velit esse molestie consequat vel illum dolore eu feugidgat nulla facilisis at vero eros et accum. San et iusto odio dign iss im qui blandit prgdaesent luptatum.

7

Auxiliary equipment compartmentOptimum space conditions for the auxiliary equipment holder – also for comprehensive controls and locking systems

The auxiliary equipment holder can be separated from the power unit and removed for adjustment works

Equipment compartmentSafe traversing of the circuit breaker with the door closed

Maintenance position facilitates direct on-site inspection without having to remove the circuit breaker

Cable or busbar connection compartment

Optional cable or busbar connection from the top or bottom

The nominal current-dependent con-nection compartment offers optimum connection conditions for cables and busbars

Reduced mounting times thanks to optimum connection compartments

Removable auxiliary equipment holder for fast adjustment works

SENTRON 3WL in maintenance position: Inspection without circuit breaker removal

Nominal current-dependent connection compart-ment for optimum connection conditions

High safety thanks to type-tested standard modules (TTA)

Test and disconnected position with the door closed

Section dimensions matched to the circuit breaker size(400 mm width up to 1600 A,600 mm width up to 3200 A,800 mm width up to 4000 A,1000 mm width up to 6300 A)

Optimum connection conditions for all nominal current ranges

Cable/busbar connection from the bottom/top

Type-tested SIVACON 8PS busbar trunking connections

Ease of operation, maximum benefits: SENTRON 3WL

Nominal current range from 630 A to 6300 A

Free selection of infeed direction without restriction of the technical data

High short-time current carrying capacity for time-selective short-circuit protection up to 400 msec guarantees safe operation of the unaffected system components

Short-circuit protection with time-reduced selectivity control for very short delay times (50 msec), indepen-dent of the number of grading levels

LCD operating current display on the control panel – without additional current meter and transformer

Page 8: Sivacon Switchboards

8

As many applications require a space-optimized assembly of the power distribution board,

various installation systems must be integrated in a section. For these application cases, the

SIVACON universal installation system offers high efficiency, safety and variability thanks to the

combination of outgoing feeders in withdrawable unit design, removable unit design,

fixed-mounted design and outgoing feeders in plug-in 3NJ6 in-line system. Furthermore,

the withdrawable unit design offers the respective flexibility for frequently changing

requirements such as changed motor ratings or connection of new consumers. In addition,

this design also accounts for ergonomic aspects and facilitates easy and safe handling as well

as short conversion times for maximum system availability.

Individual Combination Options:

Universal Installation System(Withdrawable Unit Design, Removable Unit Design)

Universal installation system with withdrawable units in combination with fixed-mounted outgoing feeders and plug-in 3NJ6 in-line unit design

Page 9: Sivacon Switchboards

9

Optionally with shutter

Plug-in busbar systemThe plug-in busbar system is arranged at the section rear. It is test-finger proof even without additional shutter to energized parts.

Arc-resistant embedding

Phase separation

3- and 4-pole design

Test-fi nger proof (IP20B)

Tap openings in 50 mm module grid for standard withdrawable units and miniature withdrawable adapters

OptionalShutters with double-action for standard withdraw-able units

Miniature withdrawable adapter optionally with shutter

Plug-in busbar system at the compartment rear Miniature withdrawable adapter at the compartment top

Miniature withdrawable adapterThe miniature withdrawable adapter is connected to the plug-in busbar system and accommodates the incoming/outgoing feeder and control wiring for miniature withdrawable units of size ¼ and ½.

Arc-resistant embedding

Phase separation

3- and 4-pole design

Test-fi nger proof (IP20B)

Tap openings for max. 4 withdrawable units of size ¼ or 2 units of size ½

OptionalShutters for miniature withdrawable units

Page 10: Sivacon Switchboards

10

High safety thanks to type-tested standard modules (TTA)

Uniform operation for all withdraw-able unit sizes

Withdrawable unit sizes matched to power ratings (miniature, standard withdrawable units)

All parts are arranged within the with-drawable unit contours – protection against damage

Integrated operation error protection for all withdrawable units

Clear indication of the withdrawable unit positions

Separate operation for main switch and withdrawable unit position

Test and disconnected position with the door closed without interruption of the degree of protection

SIVACON Withdrawable Units Offer Safety in Terms of

Operation and Handling

(Connected position) (Disconnected position) (Test position)

Moving from the connected to the disconnection position or vice versa

Moving from the disconnected position to the test position or vice versa

0 TEST

Lockable disconnected position

Patented low-wear withdrawable unit contact system for long service life

Optional withdrawable unit coding prevents confusion of withdrawable units of the same size

Swivel-mounted instrument holder with standard withdrawable units for settings during operation

Standard withdrawable units for motor and cable feeders up to 630 A

Miniature withdrawable units for motor and cable feeders up to 63 A

Fused and fuseless technology

Operation error protection prevents movement of the disconnect contacts with the main switch “ON”

Operation error protection enabled (main switch 0)

Operation error protection disabled (main switch I)

Page 11: Sivacon Switchboards

11

Miniature withdrawable unitsSize ¼ and ½height 150 mm and 200 mm(up to 48 withdrawable units per section)

Standard withdrawable unitsHeight 100 mm to 700 mm(up to 18 withdrawable units per section)

Optionally as removable design(design similar to standard withdrawable units)

Fixed contact systems for input/output and auxiliary plug (removable part)

Connected position and removed position (no test and disconnected position)

Integrated operation error protection

Lockable disconnected position

Miniature withdrawable unit, size ¼, height 150 mm

Miniature withdrawable unit, size ½, height 200 mm

Standardwithdrawable unit, height 100 mm

Standardwithdrawable unit, height 150 mm (rear view)

Swivel-mounted instrument holder for settings during operation

Page 12: Sivacon Switchboards

12

Flexibility and safety for adjustments to changed requirements

Easy conversion or retrofi tting of the withdrawable unit compartments without disconnection of the section

No connection works in the withdraw-able unit compartment required

Connections for power and control cable in separate cable connection compartment

Front-side 400 mm or 600 mm wide cable connection compartment

Rear-side 600 mm wide cable connec-tion compartment with 600 mm section width

Push-in clamp or screw connection for control cables

Withdrawable unit coding (mechanical) prevents the confusion of withdrawable units of the same size (up to 9216 coding options)

Easy insertion without having to overcome insertion forces

Withdrawable unit coding in the compartment

Withdrawable unit coding on the withdrawable unit

Page 13: Sivacon Switchboards

13

Communication via PROFIBUS DP with SIMOCODE pro

Integrated full motor protection

Comprehensive control functions

Comfortable diagnostics options

Autonomous operation of every feeder via operator panel

Reduced hardware and wiring expenditures

Fast conversion of the withdrawable unit compartments from standard to miniature withdrawable units by insertion of the miniature withdrawable adapters

Miniature withdrawable adapter (internal view)

Page 14: Sivacon Switchboards

14

As many applications require a space-optimized assembly of the power

distribution board, various installation systems must be integrated in a

section. For these application cases, the SIVACON universal installation

system offers high efficiency, safety and variability thanks to the

combination of outgoing feeders in fixed-mounted design and outgoing

feeders in plug-in 3NJ6 in-line system.

Individual Combination Options:

Universal Installation System(Fixed-Mounted Design with Compartment Doors, Plug-In 3NJ6 In-Line Design)

Universal installation system section with fixed-mounted outgoing feeders (compartment door) in combination with plug-in 3NJ6 in-line design

Page 15: Sivacon Switchboards

15

Vertical distribution busbarsManifold connection options for cables, lines and busbars without boring

CompartmentalizationAdd-on module for individual operating comfort and safety requirements

Patented connection terminalsInternal separation up to form 4b

High safety thanks to type-tested standard modules (TTA)

Cable feeders up to 630 A with/without current measuring

Combination of various installation systems (fi xed-mounted, plug-in base and plug-in 3NJ6 in-line design)

Modularly combinable function modules

Add-on modules for demand-com-pliant separation of the functional compartments (up to form 4b)

Operation front optionally with section-high door or compartment doors

Cable connection compartment with 400 mm or 600 mm width

Vertical distribution busbars Demand-compliant separation of functional compartments

Patented connection terminals

Page 16: Sivacon Switchboards

16

Several applications do not require the replacement of

components under operating conditions or tolerate short

downtimes. For these cases, the SIVACON fixed-mounted

system with front covers offers maximum efficiency, safety

and variability.

Comprehensive Integration Options:

Fixed-Mounted System with Front Covers

Fixed-mounted section with front covers, including continuously adjustable device holder for a uniform front level

High safety thanks to type-tested standard modules (TTA)

Cable feeders up to 630 A with/without current measuring

Modularly combinable function groups

Innovative quick-release locking system for easy cover mounting

Swivel-mounted cover frame for improved commission-ing and maintenance comfort

Add-on modules for demand-compliant separation of the functional compartments (up to form 4b)

Operation front with front covers, optionally with section-high door

Door with inspection pane for integration in modern room concepts

Cable connection compartment with 400 mm or 600 mm width

Page 17: Sivacon Switchboards

Duis autem vel eum iriure dolor in hendrerit in vulputate velit esse molestie consequat vel illum dolore eu feugidgat nulla facilisis at vero eros et accum. San et iusto odio dign iss im qui blandit prgdaesent luptatum.

17

Quick-release lock or swivel-mounted cover frame

Innovative quick-release lock for easy and fast cover mounting

Swivel-mounted cover frame for fast commissioning and easy maintenance

Single or multiple feedersContinuously adjustable device holders for uniform front level

Operation through the front cover

Feeders with/without plug-in base

Built-in installation devicesAluminum multiple DIN rail for easy assembly of built-in installation devices

Quick-release lock for front cover mounting Multiple feeders with SENTRON 3VL

Built-in installation devicesSwivel-mounted cover frame

Page 18: Sivacon Switchboards

18

The sections for cable feeders in fixed-mounted

system are equipped with switchable in-line

fuse switch disconnectors, whose compact and

modular design ensures the optimum efficiency

of infrastructure applications.

Efficient Assembly:

Fixed-Mounted 3NJ4 In-Line System

High safety thanks to type-tested standard modules (TTA)

Cable feeders up to 630 A with/without current measuring

Installation of up to 14 feeders per section

De-energized fuse replacement

Doors optionally with/without cut-out

Optional installation of rapid mount-ing kits or equipment holders for free equipping

Section widths of 600 mm and 800 mm

In-line section with 3NJ4 in-line fuse switch disconnectors and rapid mounting kits for built-in installation devices

Page 19: Sivacon Switchboards

19

In-line section with 3NJ6 in-line switch disconnectors

High safety thanks to type-tested standard modules (TTA)

Switch disconnector with double inter-ruption for cable feeders up to 630 A

Integrated current transformer (replaceable)

Manual or motor drive

Accessories retrofi ttable by the customer

High packing density – up to 35 feeders per section

Cable connection compartment with 400 mm or 600 mm width

Degree of protection up to IP41

Feeder replacement possible without disconnection of the power distribu-tion board

Plug-in busbar system, test-finger proof (IP20B)

3NJ6 switch disconnector with fuses

Fast Retrofitting:

Plug-in 3NJ6 In-Line System

Switching devices featuring an in-line system with an

incoming plug-in contact represent an economic alternative

to the withdrawable system and facilitate easy and

fast retrofitting and replacement works under operating

conditions thanks to their modularity. For these appli-

cations, SIVACON stands for high efficiency, safety and

flexibility.

Page 20: Sivacon Switchboards

20

Convincing Efficiency:

Reactive Power Compensation

Section for reactive power compensation 500 kvar

Reactive power forms in the mains due to inductive linear

consumers, e.g. motors, transformers, reactors, and due to

inductive non-linear consumers, e.g. power converters, welding

devices, arc furnaces, rectifiers, AC and three-phase power

controllers or UPS systems.

The sections for central reactive power compensation relieve

transformers and cables, reduce transmission losses and save

power costs. Depending on the consumer structure, the reactive

power compensation is equipped with non-choked or choked

capacitor modules.

Capacitor module 100 kvar

Controller module with electronic reactive power controller for door installation

Multi-function display

Automatic C/k value setting

Settable target power factor from 0.8 ind. to 0.8 cap.

Manual/automatic operation

Display mains parameters U, I, f, power factor, P, S, Q harmonics

Capacitor module (up to 200 kvar)Fuse switch disconnectors

Capacitor contactors

MKK capacitors

Discharge devices

Filter circuit reactors (choked)

Switch disconnector moduleOptionally available for central isolation of the installed capacitor modules

Page 21: Sivacon Switchboards

21

Optimum Protection:

Arc Resistance

The test of low-voltage power distribution boards under arc

conditions is considered a special test in accordance with

IEC 61641 and VDE 0660 Part 500, Supplement 2. This test

serves the estimation of the hazards to which persons may

be subjected in case of arcs. Thanks to the test under arc

conditions, already the SIVACON standard version offers the

proof of personnel safety.

Top plate with pressure relief in arc case

Arc barriers

Isolated main busbars

Assessment criteria1. Opening of doors and covers must be

impossible2. Parts must not fly off3. No holes must form in the enclosure4. Indicators must not ignite5. PE conductor circuit for touchable

cubicle parts must be functioning

Add-on modulesFor limiting the effects of an arcing fault within the power distribution board:

Limitation to one section (arc barriers)

Isolated main busbars (root absence)

Page 22: Sivacon Switchboards

22

The modular technology – both in the individual section

as well as throughout the entire system – facilitates the

optimum adjustability of power distribution boards to your

individual requirements.

Matched to Your Requirements

Optional busbar position at the top or rear

Individual equipping of equipment compartments, independent of busbar position and section depth

Requirement-oriented separation of functional compartments from form 1 to form 4 (DIN EN 60439-1)

Withdrawable unit, removable unit, fi xed-mounted and plug-in design can be combined in one section (universal installation system)

Optimum adjustment to space conditions

Front- and rear-aligned assembly of all switching section types

Optional single-, double-front or back-to-back assembly

Optional cable or busbar connection from the top, bottom or rear

System height optionally 2000 mm or 2200 mm

100 mm or 200 mm base as add-on module

Fast adjustment to new power requirements

Easy replacement or expansion of functional units

Sound access to busbars

Easy follow-up ordering and short delivery periods thanks to modular system

Page 23: Sivacon Switchboards

23

up to 3270 A

Main busbar position rear (top and/or bottom)

up to 4000 A

Device compartment

Busbar compartment

Cross-wiring compartment

Cable/busbar connectioncompartment

12008001000

600up to 7000 A

up to 6300 A

Main busbar position top

Page 24: Sivacon Switchboards

24

Embedded Protection:

Frame and Enclosure

The frame – including all supporting section elements –

consists of stable screw-fastened sheet-steel profiles:

Door locking systems

Top plate Bottom plate with sliding sheet

Door hinge

Circumferential hole rows with 25 mm hole grid for individual confi guration

Patented door locking system for maximum personnel safety

Doors with single or central locking

Universal door hinge for easy door hinge conversion

Door opening angle up to 125° (180° with stand-alone assembly)

Doors with espagnolette or pivoted lever lock

Top plates with pressure relief

Frame heights optionally 2000 mm or 2200 mm

100 mm or 200 mm base as add-on module

Standard section-to-section separation

Surface treatmentSendzimir-galvanized cubicle parts, bases, rear panels and bottom plates

Doors, enclosures and base covers powder-coated/lacquered in RAL 7035 light gray;design parts in blue green basic

MaterialThe frame and enclosure are made of sheet steel with the following thickness:

Cubicle, base: 2.5 mm

Enclosure: 2.0 mm

Doors: 2.0 mm

Degrees of protection in acc. with IEC 60529IP30, IP31, IP41 ventilated, IP54 non-ventilated

Page 25: Sivacon Switchboards

25

Completely Variable:

Busbar Positions

Different switching tasks require individual realization options:

Whether “simple” systems or comprehensive networks with transversal

and longitudinal couplings: SIVACON combines efficient design with

high-class quality.

Top or rear busbar position

Busbar systems for rated currents up to 7000 A

Rated peak withstand current (Ipk) up to 330 kA

Integrability of two busbar systems in the power distribution board

Transport parting points easily accessible from the front or top

Zero-maintenance busbar connections

Add-on modulesArc barrier for limitation of arcing effects to one section

Isolated busbar systems (base-free design)

Vertical PE and N conductor rails arranged in the cableconnection compart-ment at the right

Transport parting points easily accessible from the front

Busbar positionrear

N/PEN

L1

L2

L3

PE PE

N/PENL3

L2L1

Busbar positiontop

Page 26: Sivacon Switchboards

26

Standards and regulations Type-tested low-voltage switchgear IEC 60439-1 and controlgear assembly (TTA) DIN EN 60439-1 (VDE 0660 Part 500)

Testing of response to internal IEC 61641, VDE 0660 Part 500, Supplement 2 faults (arcing faults) (Ue up to 440 V, Icw up to 50 kA, t = 100 msec)

Protection against electric shock DIN EN 50274, VDE 0660 Part 514

Rated insulation voltage (Ui) Main circuit 1000 VRated operational voltage (Ue) Main circuit Up to 690 V

Clearances and creepage distances Rated impulse withstand voltage Uimp 8 kV / 12 kV Overvoltage category III / IV Pollution degree 3 Busbars Main busbars horizontal Rated current up to 7000 A(3-pole and 4-pole) Rated peak withstand current (Ipk) up to 330 kA Rated short-time withstand current (Icw) up to 150 kA

Busbars vertical for Rated current up to 6300 A circuit breaker system Rated peak withstand current (Ipk) up to 220 kA Rated short-time withstand current (Icw) up to 100 kA

Busbars vertical for Rated current up to 1600 A universal and fixed-mounted Rated peak withstand current (Ipk) up to 143 kA system Rated short-time withstand current (Icw) up to 65 kA*

Busbars vertical for Rated current up to 1600 A 3NJ4 in-line system Conditional rated short-circuit current (Icc) up to 50 kA (fixed-mounted)

Busbars vertical for Rated current up to 2100 A 3NJ6 in-line system Rated peak withstand current (Ipk) up to 110 kA (plug-in) Rated short-time withstand current (Icw) up to 50 kA*

Rated device currents 3WL/3VL circuit breakers up to 6300 A Cable feeders up to 630 A

Internal separation Form 1 to form 4 IEC 60439-1, Section 7.7, VDE 0660 Part 500, 7.7

Surface treatment (Coating acc. to DIN 43656) Frame parts, bases Sendzimir-galvanized Doors Powder-coated Side panels Powder-coated Rear panels, top plates Sendzimir-galvanized Ventilation roof Powder-coated Standard color of powder-coated parts RAL 7035, light gray (coating thickness 100 ± 25 µm) Design parts: blue green basic IP degree of protection In acc. with IEC 60529, EN 60529 IP30, IP31, IP40, IP41, IP54 Dimensions Preferred dimensions Height (without base): 2000, 2200 mm in acc. with DIN 41488 Width: 400, 600, 800, 1000, 1200 mm Depth (single-front): 500, 600, 800 mm Depth (double-front): 1000, 1200 mm

* Conditional rated short-circuit current (Icc) = 100 kA

At a Glance:

Technical Data

Page 27: Sivacon Switchboards

27

Project Checklist

Customer Processor

Project Telephone

Order No. Fax

Delivery date Date

Standards and regulations IEC 60439-1/EN 60439-1 IEC 61641/VDE 0660 Part 500, Supplement 2 Arc barriers for limitation of arcs

VDE 0660 Part 500 arc resistance to one section (standard 440 V, 50 kA, 100 msec)

Environmental conditionsEnvironmental class (acc. IEC 60721-3-3) Interior room climate 3K4 Ambient temperature (24-h average) 20 °C 25 °C 30 °C 35 °C 40 °C 45 °C 50 °CErection height above sea level ≤ 2000 m other IP degree of protectionagainst the interior section ventilated IP30 IP31 IP40 IP41 section non-ventil. IP54 (not 3NJ6 in-line design, reactive power compensation)against the cable bottom IP00 IP30 IP40 IP54 manufacturer-provided customer-providedAggravated operation conditions none chemical emissionsControl cabinet heating no yes

Mains data / infeed dataNetwork type TN-C TN-S TN-C-S IT TT Design L1, L2, L3, PEN L1, L2, L3, PE + N other: external connection CEP (PEN + PE) 3-pole switchable 4-pole switchableRated transformer power Sr kVA Rated short-circuit voltage Uz %Rated operational voltage Ue V Frequency f HzRated short-term withstand current Icw kA

Busbar system horizontalPosition top rear (top) rear (bottom) Rated current In A A A Treatment CU blank silver-plated tin-plated isolated L1, L2, L3 isolated L1, L2, L3, N Design AC L1, L2, L3 + .... PEN PE N PEN, N = 50 % PEN, N = 100 % Busbar system verticalTreatment CU blank silver-plated tin-plated isolated to breaker (circuit breaker design)Design AC L1, L2, L3 + ..... PEN PE N PEN, N = 50 % PEN, N = 100 %Other conditions Assembly and erectionAssembly type single-front double-front back-to-back Restriction of total length without yes mmMax. net length per transport unit 2400 mm mmCable/busbar connectionwith incoming feeder sections from the bottom from the top from the rearwith outgoing feeder sections from the bottom from the top from the rear

SectionsInternal separation in acc. with IEC 60439-1, DIN EN 60439-1, VDE 0660 Part 500, Section 7.7 Circuit breaker system form 1 form 2b form 3a form 4bUniversal installation system form 2b form 3b form 4a form 4bFixed-mounted system form 1 form 2b form 4a form 4bFixed-mounted 3NJ4 in-line system form 1 form 2b Plug-in 3NJ6 in-line system form 3b form 4bReactive power compensation form 1 form 2b

Page 28: Sivacon Switchboards

www.siemens.com/automationwww.siemens.com/sivacon

Subject to changes without prior notice 02/08Order No.: E20001-A410-P309-X-7600DISPO 276062100/8282 EVPX.52.8.02 WS 02085.0Printed in Germany © Siemens AG 2008

The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract.

All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.

Siemens AGIndustry SectorIndustry AutomationP.O. Box 48 4890327 NUREMBERGGERMANY

Fax order +49 (911) 978-3321 – CD/Z1329

Company/department

Name

Street, ZIP/city/country

Telephone/fax

E-mail

Information material

Please send the selected informationmaterial to the following address:

Service & Support

Download of catalogs and information material:www.siemens.com/lowvoltage/catalogs

Newsletter – always up-to-date:www.siemens.com/lowvoltage/newsletter

E-business in the A&D Mall:www.siemens.com/lowvoltage/mall

Online support:www.siemens.com/lowvoltage/support

Technical Assistance:www.siemens.com/technical-assistance

DIS

TRIB

UTI

NG

SWIT

CH

ING

,PR

OTE

CTI

NG

&M

EASU

RIN

GM

AN

AG

ING

POW

ER D

ISTR

IBU

TIO

N

SOFT

WA

RE

Power management system

SIVACON power distribution boards

SIVACON busbar trunking systems

SIVACON cubicle systems

SENTRON circuit breakers

SENTRON switch disconnectors

SENTRON multimeters

Dimensioning with SIMARIS design

Power management with SIMATIC powercontrol

Totally Integrated Power

For further information, please contact yourlocal Siemens sales partner.

For technical questions, please contact:Technical AssistanceTel.: +49 (911) 895-5900E-mail: [email protected]