site report hephy-uibk austrian federated tier 2 meeting 03.03.2008

15
Site Report HEPHY- UIBK Austrian federated Tier 2 meeting 03.03.20

Post on 21-Dec-2015

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Site Report HEPHY-UIBKAustrian federated Tier 2 meeting

03.03.2008

Page 2: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Content

• Overview HEPHY-UIBK

• Site Services

• Hardware

• Power and Cooling

• Planned Projects

03.03.2008

Page 3: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Rack 2 Rack 1

Overview HEPHY-UIBK

03.03.2008

WMS/LB

MON

EGEE-Cluster

Testbed

Page 4: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Facts

WNs: 26 (76 Cores) without testbed

CEs: 3

UIs: 2

SEs: 2x DPM and 1 classic SE

Storage: ~16 TB on two Raids

WMS/LB: 1

MON: 1

VOs: atlas, ops, dteam, bphys, uibktest

03.03.2008

Page 5: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Gigabitswitch8 Ports

CE UI DPM

Top Raid2x 1.7 TB

. . .

. . . . .. . .

Testbed

16 Worker Nodes(32 Cores)

NAT Firewall

Rack 1

SCSI

03.03.2008

Gigabitswitch24 Ports

Page 6: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Gigabitswitch

CE / classic SE Easy Raid13 TB

Fileserver

10 Worker Nodes(44 Cores)

NAT Firewall

03.03.2008

Rack 2

. . .

. . . . .. . .

Gigabitswitch24 Ports

Page 7: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Content

• Overview HEPHY-UIBK

• Site Services

• Hardware

• Power and Cooling

• Planned Projects

03.03.2008

Page 8: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Site Services

• User Interface (UI) • Computing Element (lcg CE)• Storage Element (classic SE)• Storage Element (DPM)• Information Service (BDII)• Resource Broker (WMS/LB)• Monitoring (MON)

03.03.2008

gLite 3.0Scientific Linux 3.0.8

gLite 3.1Scientific Linux 4.5

• User Interface (UI)• Computing Element (lcg CE)• Storage Element (DPM)• Worker Node (WN)

Page 9: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Content

• Overview HEPHY-UIBK

• Site Services

• Hardware

• Power and Cooling

• Planned Projects

03.03.2008

Page 10: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Hardware

WN: 16x Intel Xeon (32 Cores), 3.0 GHz, 1 GB RAM per core , 80 GB SATA 9x Intel Xeon (36 Cores), 3.0 GHz, 1.5 GB RAM per core , 80 GB SATA

1x Intel Xeon (8 Cores), 2.33 GHz, 1.5 GB RAM per core , 80 GB SATA

03.03.2008

CE: Intel Xeon (2 CPUs), 2.66 GHz, 2 GB RAM , 80 GB IDE AMD Opteron (4 Cores), 2.6 GHz, 4 GB RAM, 80 GB SATA

Page 11: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Hardware (2)

03.03.2008

SE: Intel Xeon (2 CPUs), 2.66 GHz, 2 GB RAM AMD Opteron (4 Cores), 2.6 GHz, 4 GB RAM

Storage:TopRaid: 2x 1.7 TB, Raid 5EasyRaid: 13TB (16x 1 TB), Raid 6

Page 12: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Content

• Overview HEPHY-UIBK

• Site Services

• Hardware

• Power and Cooling

• Planned Projects

03.03.2008

Page 13: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Power and Cooling

Wattage EGEE-Cluster:• Rack 1: max. 6.5 kW• Rack 2: max. 4 kW

Used cooling methods:• air cooling• water cooling (CoolAdd)

CoolAdd:• cooling Capacity 8 kW• wattage: max. 725 W• weight: ~45 kg

03.03.2008

Page 14: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Content

• Overview HEPHY-UIBK

• Site Services

• Hardware

• Power and Cooling

• Planned Projects

03.03.2008

Page 15: Site Report HEPHY-UIBK Austrian federated Tier 2 meeting 03.03.2008

Planned Projects

• Installation of MON and WMS/LB on SL4

• Migration of the classic SE to DPM

• Build up UI, MON and WMS/LB as virtual machines with XEN

• Migration of DPM from SL3 to SL4

03.03.2008