site power monitor - talley inc.alarms-high and low trip, 50 max, user-programmable logging-excel...

4
Monitoring the Network Web-enable and integrate intelligence to any site’s AC and DC power system for 24/7 monitoring, alarm condition notification, and data logging of vital electrical functions. All programmable, accessible, and managed via the Internet: TCIP or SNMP. View current conditions and log 30 day history of DC and AC power status at remote sites before dispatching personnel. The Site Power Monitor is designed specifically for monitoring power supplies, rectifiers, batteries, converters, inverters, UPS, distribution panels, and AC power at communication sites, base stations, outdoor enclosures, and command vehicles via Ethernet or Wireless connection. The palm sized unit can be rack, DIN-rail, or wall mounted and is easily adapted to virtually any make of power system via nine sensor input ports which capture and stream critical data via the internet for analysis and logging of site history. Web page based programs are easily user configured for site parameters with up to 50 desired alarm conditions settings and multiple automatic notification options by e-mail and mobile phone. Sites without internet access can use the monitor solely as a data logging instrument that captures and retains a 30 day history file, ready for download to a lap top computer during maintenance visits for recording site history and analysis of component performance and failure conditions. Remote Monitoring Of Critical Site Conditions: • DC Bus/Battery Voltage • DC System Amperage/Battery Charge-Discharge Current • AC Voltage • Temperature • Programmable Alarms • Data Logging Monitoring Via: • Internet – All Software Provided • E-Mail • Cell Phone • Ethernet Camera Cell Sites • Mesh Radio Networks & Outdoor Enclosures • Command Vehicles • Rack Power Systems • Microwave Hubs SITE POWER MONITOR Questions? Visit www.Talleycom.com or contact Talley at 800.949.7079 or [email protected] today.

Upload: others

Post on 14-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Site power monitor - Talley Inc.Alarms-HIGH and LOW trip, 50 max, user-programmable Logging-Excel logs created, time stamped, continuous graphing SMTP/POP3- email alerts, POP password

Monitoring the Network

Web-enable and integrate intelligence to any site’s AC and DC power system for 24/7 monitoring, alarm condition notification, and data logging of vital electrical functions. All programmable, accessible, and managed via the Internet: TCIP or SNMP. View current conditions and log 30 day history of DC and AC power status at remote sites before dispatching personnel.

The Site Power Monitor is designed specifically for monitoring power supplies, rectifiers, batteries, converters, inverters, UPS, distribution panels, and AC power at communication sites, base stations, outdoor enclosures, and command vehicles via Ethernet or Wireless connection. The palm sized unit can be rack, DIN-rail, or wall mounted and is easily adapted to virtually any make of power system via nine sensor input ports which capture and stream critical data via the internet for analysis and logging of site history. Web page based programs are easily user configured for site parameters with up to 50 desired alarm conditions settings and multiple automatic notification options by e-mail and mobile phone.

Sites without internet access can use the monitor solely as a data logging instrument that captures and retains a 30 day history file, ready for download to a lap top computer during maintenance visits for recording site history and analysis of component performance and failure conditions.

Remote Monitoring Of Critical Site Conditions:• DC Bus/Battery Voltage• DC System Amperage/Battery

Charge-Discharge Current• AC Voltage• Temperature• Programmable Alarms• Data Logging

Monitoring Via:• Internet – All Software Provided• E-Mail• Cell Phone• Ethernet Camera

Cell Sites • Mesh Radio Networks & Outdoor Enclosures • Command Vehicles • Rack Power Systems • Microwave Hubs

SITE POWER MONITOR

Questions? Visit www.Talleycom.com or contact Talley at 800.949.7079 or [email protected] today.

Questions? Visit www.Talleycom.com or contact Talley at 800.949.7079 or [email protected] today.

Page 2: Site power monitor - Talley Inc.Alarms-HIGH and LOW trip, 50 max, user-programmable Logging-Excel logs created, time stamped, continuous graphing SMTP/POP3- email alerts, POP password

Monitoring the Network

Via Internet

Data Screens

Alarm Notification

s

Via Cell Phone

EthernetBased Camera

Data Logging

Sensors

Alarms

Web Cam

Data Out To

Internet

Network

Via E-mail

SITE POWER MONITORMonitoring Options

For A Live Demo Go To http://spmsamplesite.newmarpower.com

Questions? Visit www.Talleycom.com or contact Talley at 800.949.7079 or [email protected] today.

Page 3: Site power monitor - Talley Inc.Alarms-HIGH and LOW trip, 50 max, user-programmable Logging-Excel logs created, time stamped, continuous graphing SMTP/POP3- email alerts, POP password

Monitoring the Network

Rectifier/Battery Charger• DC Bus Voltage & Current• Output Current

DC Distribution Panels• Bus Voltage• Load Current• Breaker Trip Alarm

Enclosure Power Supply• DC Voltage• DC Current

Solar Power Voltage

DC Converter• Input/Output Voltage• Output Current

AC Voltage

Generator Voltage

Battery• Voltage 12/24/48• Charge/Discharge

Current

AmbientTemperature

Door Open Alarm

Low Voltage Disconnect • Disconnect Status• Battery Voltage

Inverter• DC Input Voltage• AC Output Voltage• Alarms

Site Power System• Alarms - Major/Minor• Voltages• Current• Temperature

Data Out To Internet

SITE POWER MONITOR

Questions? Visit www.Talleycom.com or contact Talley at 800.949.7079 or [email protected] today.

Page 4: Site power monitor - Talley Inc.Alarms-HIGH and LOW trip, 50 max, user-programmable Logging-Excel logs created, time stamped, continuous graphing SMTP/POP3- email alerts, POP password

Monitoring the Network

SITE POWER MONITORInputsPower Source Voltage: 9-60 negative / positive ground, 250 mA max.

Monitor Inputs: 9 TotalVoltage:

DC: 3 Ports: • 2each0-40VDC• 1each36-60VDC• Accuracy+/-2%

AC: 2 Ports:• 120/240(90-264)utilitypower(L-NorL-L)• 120/240inverteroutput(floating)• Accuracy+/-2%

DC Current: 1 Port• +/-100mv,100ampdifferentialshuntvoltage• Readbatterycharge/dischargecurrent,orloadcurrent• Shuntrequired,notprovidedwithmonitorpackageP/N

575-2000-0• Accuracy+/-3%

Dry Contact Switch Sensors, 3 Ports• Possible uses: include: door open, water leak detection, smoke

alarm, component fail, breaker trip, etc.Temperature Sensor

• Locatedoutsidecaseofunit• Range-40to+60C,-40to+140F• Accuracy+/-0.5C

Reporting EthernetPortconnection:RJ-45,10/100autosenseHTTP-Web Access, Self-generated Web-pageSNMP-MIB with Gets, Traps, and ClearsAlarms-HIGHandLOWtrip,50max,user-programmableLogging-Excellogscreated,timestamped,continuousgraphingSMTP/POP3-emailalerts,POPpasswordDataFormats:XML,PDA,WAP(cellphone)OptionalConsole-MultipleSiteMonitorwithlogaggregationandthumbnail camera views RemoteFirmwareupgrades-noneedtovisitthesite.LocalDatadownloadingandprogrammingrequireandRJ-45cross-overcable(notincluded)Data Screens:

• Sensors• Alarmsettings(customizedwebpage)• Datalogging• Camerafeeds(4max.)

Data logging: Remote Or Download Locally:• 30day+rollinghistorywith30secondintervalrefresh• CSVfilecompatible

Images: Ethernet Camera Enabled

Alarms• 50userconfigurableallwithseparatehigh/lowtripsettings• NotificationbyViaInternet,e-mailormobilephone• User-programmablenotificationto5differente-mailsaddresses

Diagnostics/Indicators/ControlsFront panel LED’s:

• InputPowerON/OK• SystemOK• FlashingActivityIndicatorEthernetport• Systemresetbutton

Protections• ReversePolarity• Inputovervoltage• External1Aslo-blofuseprovidedforDCpowerinput

MechanicalCase: Aluminum / powder coatSize:2.18”x3.27”x4.66”Weight:1lbMounting options:

• Wallmount• Dinrail• 19or23inchrackmount(viaoptionalbracket)

Input Ports:• CompressionScrewterminalblock• 14-26awgwire

Optional Accessories• VideoCameras• 12or24voltwallplugpowersupply• Sensors

• Water• Door/windowopenalarm• Fire/smokedetector• Shunts

• Software• Multisitemonitorsoftware-upto100sites• Rackmountpanelfor19/23”racks

Environmental:• OperatingTemperaturerange—20Cto60C

Warranty: 2 years

SPM-200 with optional rack mount panelfor19/23”racks

Site Power Monitor Specifications Model: SPM-200

Questions? Visit www.Talleycom.com or contact Talley at 800.949.7079 or [email protected] today.