1
N S E W KEN PHILPOT DESIGN LTD. The Office Manor Farm Horseheath Cambridgeshire CB21 4QF t - 01223 893938 m - 07860 284563 e - [email protected] PROJECT: H.S.F.C NEW SITE TITLE: SITE PLAN - PLANNING DRAWING NO. 006 REV: 24 SCALE: 1:1250 @ A3 DATE: 18/07/13 Water tank & irrigation system housing. Details TBA by specialist. Site boundary & perimeter fencing. Fencing requirements TBA following inspection of existing hedgerows and landscaping. 8m x 10m grounds-man & equipment storage. Spectator areas. Main pitch - regulation size 3G all weather pitch (or approved alternative). Car parking for 56 no. vehicles. Bays will not be marked and are shown indicatively. Access / road. Service and emergency access / road. 4m high bund and landscaping buffer strip. Landscaping by consultant. 1.8m high close board boundary fence all round main pitch. 3 no. covered turnstiles, 2 no. disabled access & emergency exit gate. Adjacent emergency exit gate to provide access for emergency vehicles & maintenance vehicles into stadium area. Grassed area. 2m high chain link fence with concrete posts. New private access road. Existing hedgerows & ditch retained. Existing hedgerows retained. Goldhanger Rd. Heybridge Basin Existing hedgerow retained. Existing hedgerows retained Existing hedgerows retained & bolstered as required. Site boundary & perimeter fencing. Fencing requirements TBA following inspection of existing hedgerows and landscaping. Delivery bay. Disabled parking (6 no. bays) d d d d d d SITE PLAN - PLANNING 22m x 1.9m x 2.95m high standing stand for 250 people. Second access / exit to pitch side and emergency exit from stadium area. 1.1m high tubular pitch perimeter fence infilled with metal mesh. Emergency vehicle access to pitch through pitch perimeter fence. Site boundary & perimeter fencing. Fencing requirements TBA following inspection of existing hedgerows and landscaping. Floodlight pylon location. Floodlight pylon location. Floodlight pylon location. Stand to accomodate 250 people. Seating, lighting and writing facilities to be incorporated for 4 no. press. 24 seats reserved for club officials. Disabled access & seating as required. Floodlight pylon location. 1.8m high wire mesh fence to equipment storage compund. Floodlight pylon location. Floodlight pylon location. Floodlight pylon location. Refuse collection point. Club officials parking (6 no. bays). 5m high ball catch netting system behind goal. 5m ball catch netting system behind goal. 5m high ball catch netting system behind goal. Additional stand as part of future development. Additional stand as part of future development. 5m ball catch netting system behind goal. Floodlight pylon location. Floodlight pylon location. Floodlight pylon location. Typically denotes 100x100mm x 1.1m timber bollards at approx 2m ctrs. 1.8m high wire mesh fence with access gates in locations shown. Junction details with Goldhanger Road as agreed with Highways Authority Existing hedgerow retained where possible. Extent of diverted ditch. 5m high ball catch netting system behind goal. Space for pigeon club hut (8m x 8m) Car parking for 57 no. vehicles. Bays will not be marked and are shown indicatively. Floodlight pylon location. SALTCOTE HALL *NOTE The final detail design of the bund will be by ODQGVFDSH FRQVXOWDQWV 7KH EXQG GHWDLOV ZLOO DFFRUG ZLWK WKH DFRXVWLF UHSRUW UHFRPPHQGDWLRQV All planting and fencing details to be by landscape FRQVXOWDQW $OO GHWDLOV WR EH VXSSOLHG E\ ZD\ RI FRQGLWLRQ VXEMHFW WR SODQQLQJ DSSURYDO EHLQJ JUDQWHG Extent of diverted ditch. 1.8m high wire mesh fence with access gates in locations shown. 1.2m high wire mesh fence & hedgerow to base of bund with access gate in location shown. 1.2m high wire mesh fence & hedgerow to base of bund with access gate in location shown. Land excluded from application. Retained by land owner. Dropped kerb / crossover. 1.8m high wire mesh fence.

Upload: others

Post on 18-Dec-2021

16 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SITE PLAN - PLANNING

N

S

EW

KEN PHILPOT DESIGN LTD.

The Office

Manor Farm

Horseheath

Cambridgeshire

CB21 4QF

t - 01223 893938

m - 07860 284563

e - [email protected]

PROJECT: H.S.F.C NEW SITE

TITLE: SITE PLAN - PLANNING

DRAWING NO. 006 REV: 24

SCALE: 1:1250 @ A3 DATE: 18/07/13

Water tank & irrigation system housing. Details TBA by specialist.

Site boundary & perimeter fencing. Fencing requirements TBA

following inspection of existing hedgerows and landscaping.

8m x 10m grounds-man & equipment storage.

Spectator areas.

Main pitch - regulation size 3G all

weather pitch (or approved alternative).

Car parking for 56 no. vehicles.

Bays will not be marked and are

shown indicatively.

Access / road.

Service and

emergency

access / road.

4m high bund and landscaping buffer strip.

Landscaping by consultant.

1.8m high close board boundary

fence all round main pitch.

3 no. covered turnstiles, 2 no. disabled access

& emergency exit gate. Adjacent emergency exit

gate to provide access for emergency vehicles

& maintenance vehicles into stadium area.

Grassed area.

2m high chain link fence

with concrete posts.

New private access road.

Existing hedgerows & ditch retained.

Existing

hedgerows

retained.

G

o

ld

h

a

n

g

e

r

R

d

.

Heybridge B

asin

Existing hedgerow

retained.

Existing hedgerows retained

Existing hedgerows retained

& bolstered as required.

Site boundary &

perimeter fencing.

Fencing requirements

TBA following inspection

of existing hedgerows

and landscaping.

Delivery bay.

Disabled parking (6 no. bays)d

d

d

d

d

d

SITE PLAN - PLANNING

22m x 1.9m x 2.95m high standing

stand for 250 people.

Second access / exit

to pitch side and

emergency exit

from stadium area.

1.1m high tubular pitch perimeter

fence infilled with metal mesh.

Emergency vehicle access to pitch

through pitch perimeter fence.

Site boundary

& perimeter

fencing. Fencing

requirements

TBA following

inspection of

existing

hedgerows and

landscaping.

Floodlight pylon location.

Floodlight pylon location.

Floodlight pylon location.

Stand to accomodate

250 people. Seating,

lighting and writing

facilities to be

incorporated for 4 no.

press. 24 seats

reserved for club

officials. Disabled

access & seating

as required.

Floodlight pylon

location.

1.8m high wire mesh fence to equipment storage compund.

Floodlight pylon location.

Floodlight pylon location.

Floodlight pylon

location.

Refuse collection point.

Club officials parking (6 no. bays).

5m high ball catch netting system behind goal.

5m ball catch netting

system behind goal.

5m high ball catch netting system behind goal.

Additional stand as part of future development.

Additional stand as part of future development.

5m ball catch

netting system

behind goal.

Floodlight pylon

location.

Floodlight pylon location.

Floodlight pylon location.

Typically denotes 100x100mm x 1.1m

timber bollards at approx 2m ctrs.

1.8m high wire mesh fence with

access gates in locations shown.

Junction details with

Goldhanger Road

as agreed with

Highways Authority

Existing hedgerow retained where possible.

Extent of diverted ditch.

5m high ball catch netting system behind goal.

Space for pigeon club hut (8m x 8m)

Car parking for 57 no. vehicles.

Bays will not be marked and are

shown indicatively.

Floodlight pylon location.

SALTCOTE HALL

*NOTE

The final detail design of the bund will be by

landscape consultants. The bund details will

accord with the acoustic report recommendations.

All planting and fencing details to be by landscape

consultant. All details to be supplied by way of

condition subject to planning approval being granted.

Extent of diverted ditch.

1.8m high wire mesh fence with

access gates in locations shown.

1.2m high wire mesh fence & hedgerow

to base of bund with access gate in

location shown.

1.2m high wire mesh fence & hedgerow to base

of bund with access gate in location shown.

Land excluded from application.

Retained by land owner.

Dropped kerb / crossover.

1.8m high wire mesh fence.