sip t2300 generator manual
TRANSCRIPT
-
7/22/2019 SIP T2300 Generator Manual
1/8
16
FOR HELP OR ADVISE ON THIS PRODUCT PLEASE CALL OUR
CUSTOMER SERVICE HELP LINE : 01509 500300
Please dispose of packaging for the product in a responsiblemanner. It is suitable for recycling. Help to protect theenvironment, take the packaging to the local amenity tip andplace into the appropriate recycling bin.
Never dispose of electrical equipment or batteries in withyour domestic waste. If your supplier offers a disposal facil-ity please use it or alternatively use your local amenity tipand dispose in the correct manner. This will allow the recy-cling of raw materials and help protect the environment.
1
Medusa T2300
Generator
Please read and fully understand the instructions in thismanual before operation. Keep this manual safe for future
reference
-
7/22/2019 SIP T2300 Generator Manual
2/8
2
SAFETY INSTRUCTIONS
Two persons are required to safely remove this machine from its pack-aging due to its weight.
15
DECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY
WESIP LTD
GELDERS HALL ROAD
SHEPSHED
LOUGHBOROUGH
LEICESTERSHIRELE12 9NH
Declare that the
Medusa 2300 SIP Pt No. 04511
Suppliers Part No. TG2700
Complies with the following EEC Directives their supporting StatutoryInstruments and the relevant standard where applicable:
98/37/EC Machinery DirectiveEN 12601:2001
73/23/EEC Low Voltage Directive
89/336/EEC EMC Directiveand amendments EN 55012:2002
93/68/EEC EN 61000-6-1:2001
EN 61000-6-3:2001
2000/14/EEC Noise Directive
Signed:
Joint Managing Director
Date: 15th June 2004
-
7/22/2019 SIP T2300 Generator Manual
3/8
14
NOTES
3
TECHNICAL DATA
SIP MODEL NUMBER 04511
DIMENSIONS L X W X H 525 X 420 X 450MM
NET WEIGHT 44KG
ENGINE TYPE 4 STROKE, OHV, PETROL
OUTPUT VOLTAGE 230V 50HZ AC
OUTPUT CURRENT 10A AC
MAX OUTPUT 2300 WATTS
CONTINUOUS RATED OUTPUT 2000 WATTS
NOISE @ 4 METERS 72DB(A) (97LWA)
FUEL UNLEADED
OIL SAE 20W (0C TO 25C)
FUEL TANK CAPACITY 12 LTR
APPROX FULL TANK RUN TIME(HRS)
10
ENGINE OIL CAPACITY O.6LTR
SPARK PLUG TYPE BPR4ES (NGK)
SPARK PLUG GAP 0.7 mm - 0.8 mm
VALVE CLEARANCE 0.05mm / 0.0004
-
7/22/2019 SIP T2300 Generator Manual
4/84
GETTING TO KNOW YOUR PRODUCT
13
PARTS LIST
-
7/22/2019 SIP T2300 Generator Manual
5/812
EXPLODED DIAGRAM
5
GUARANTEE
Guarantee
This product is covered by a 12 month parts and labour warranty
covering failure due to manufacturers defects. This does not coverfailure due to misuse or operating outside the scope of this man-ual.In the unlikely event of warranty claims, contact your distributor orcontact our help line on the back page of this manual. Proof of pur-chase will be required before any warranty can be honoured
There is a very real risk of electric shock if this generator is notused in the correct manner. NEVERUse or expose the genera-
tor or any thing connected to it to wet conditions .
During normal operation certain parts of this generator willbecome hot.ALWAYSstay alert and be aware of hotcomponents / surfaces. Allow the engine to cool before
attempting to move, clean or maintain the generator.
The fuel used to run this generator (unleaded petrol) is highlyflammable. Never re-fuel the generator whilst it is still running.Store un used fuel safely and away from children.
Caution: Exhaust fumes are poisonous. Do not operate thisgenerator in enclosed areas.
SAFETY SYMBOLS
-
7/22/2019 SIP T2300 Generator Manual
6/8
-
7/22/2019 SIP T2300 Generator Manual
7/810
MAINTENANCE.CONTINUED
SPARK PLUG INSPECTION
Remove spark plug with the plug spanner supplied Inspect the spark plug. It should be a tan colour If necessary adjust the gap. (See technical spec) Replace the spark plug with correct torque:20nm REPLACE SPARK PLUG IF RQUIRED
EXHAUST SCREEN
Wait until the exhaust is cool. Remove any carbon deposits that may be building up. Undo the screw cap and remove the exhaust screen. Clean with wire brush and refit If exhaust screen is damaged, replace it.
AIR FILTER
Do not run engine without the air filter fitted. Unscrew the air filter cover Remove filter and wash well in solvent
Pour a small amount of oil onto the filter element andgently squeeze out any excess oil.
Replace the filter element and filter cover Ensure the filter cover seals correctly
FUEL FILTER
Remove fuel filler cap. Remove fuel filter and wash in solvent
7
OPERATING INSTRUCTIONS.CONTINUED
STARTING YOUR GENERATOR
Step 1: Turn on fuel tap.Step 2: Turn on the engine switch.Step 3: Move choke lever to closed position.
Choke LeverFuel Tap
EngineSwitch
Step 4: Pull slowly on the starter cord until it engages, thenpull sharply to start the engine.Step 5:Allow the engine to run until it warms up, thenmove the choke lever to the open position.Step 6: Plug in the power cord and switchthe AC switch to ON.
PullCord
AC PowerSwitch
-
7/22/2019 SIP T2300 Generator Manual
8/88
OPERATING INSTRUCTIONS..CONTINUED
STOPPING YOUR GENERATOR
STEP 1: Turn offthe ACpowerswitchSTEP 2: Unplug all power cordsSTEP 3: Turn engine switch to off
AC Power switch
Power cord
Engine switch
Step 4: Turn off the fuel tap
Step 5: Remove any power cords
Fuel Tap
Power Cord
9
MAINTENANCE
Place the generator on level ground Remove filler cap Open drain plug and collect oil in a suitable container Check gaskets, replace if required. Re-fit drain plug and
refill with suitable oil (0.6Ltr) Replace filler cap.
OIL REPLACEMENT ( ensure that the engine is warm )
STOP THE ENGINE BEFORE YOU CARRY OUT ANY MAINTENANCE