DRAWING SCHEDULESHEET
WD-02WD-03WD-04WD-05WD-06WD-07WD-08WD-09WD-10WD-11WD-12WD-13WD-14WD-15
NAMECOVERINDEXSITE PLANLANDSCAPE PLANGENERAL NOTESFLOOR PLANELEVATIONSELEVATIONSSECTIONROOF PLANELECTRICAL PLANWINDOW & DOOR SCHEDULEDETAILSENERGY RATING SUMMARYMATERIALS & FINISHES
ISSUE DATE REMARKS
Intrax Consulting Engineers Pty Ltd ABN: 31 106 481 252
Head Office: 35 Bank St, South Melbourne VIC 3205 P: 03 8371 0100 F: 03 8371 0199
www.intrax.com.au
Site Classification AS2870-2011 Residential Slabs and
Footings
Date: 03/7/2017
Date of Fieldwork: 1/7/2017
Site Number: 97003
Site Address: Lot. 1251, Clifton Circuit, Tarneit, Vic, 3029
Client: Omaxe Homes
Summary of Assessment Results
Site Classification:
“P” in accordance with AS2870-2011
Wind Rating:
“N1” in accordance with AS4055-2012
Bushfire Attack Level:
“N/A” in accordance with AS3959-2009
AREAS: SQMETERES SQUARES
GROUND FLOOR 234.00 25.16
GARAGE 37.00 3.98
PORCH 8.00 0.86
ALFRESCO 15.00 1.61
Total: 294.00 31.61
COVERAGE 57%
PERMEABILITY 35%
IMPERMIABILITY 8%
Plot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
INDEX
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-02
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT
15/06/2018
I:\SEAGATE FILES\OMAXE HOMES 2017 PROJECTS\LOT 1251\LOT 1251-AD.pln
GSPublisherVersion 286.26.100.67
D
D.P
D.P
D.P
D.P
S.D.
EF
EF
EF
D.P
EF
EF
S.D.
D.P
D.P
4,000
1,25
0
5,541
3,972
2,74
050
0
1,200
3,268
FFL+100.20
FFL+100.14
EASE
MEN
T @ 2
m
CR
OS
SO
VER
FOO
TPA
TH
SWD
SWD
SWD
LPOD
AS OF 1.09.17
AS OF 1.09.17
AS
OF
1.09
.17
AS
OF
1.09
.17
PROPOSED NEW DWELIINGLOT 1251SITE : 512m2
DOWNPIPE TO BE DETERMINED ON SITE BYPLUMBER AT MAX 12000CTS.MAXIMUM GRADE OF 1:2 TO ALL UNRETAINEDEXCAVATIONSPROVIDE MINIMUM 1000mm CLEAR TO SKY ANYHABITABLE ROOM WINDOW
NOTES:STORMWATER SHALL BE TAKEN BE TAKEN TO LEGALPOINT OF IS HCHARGE TO THE SATISFACTION OF THERELEVENT AUTHORITY.SEWER OR SEPTIC SYSTEM SHALL BE IN ACCORDANCEWITH THE RELEVENT AUTHORITY'S REQUIREMENTS.FOOTING NOT TO ENCROACH TITLE BOUNDARIES ANDEASEMENT LINES.BUILDER IS TO CONNECT NEW DOWNPIPES TO
EXISTING STORM WATER DRAIN SYSTEM VIA90mm DIAMETER UPVC SWD WITH MINIMUM 1:80GRADE & 300mm EARTH COVER
BUILDER IS TO CHECK RUN OF EXISTING SWDSYSTEM ON SITE PRIOR TO COMMENCEMENT OFWORKS.
BUILDER TO DISCHARGE NEW DOWNPIPES OVERROOF BELOW VIA SPREADERS WHEREREQUIRED
N
SITE PLAN1:200
Plot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
SITE PLAN
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-03
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT
15/06/2018
I:\SEAGATE FILES\OMAXE HOMES 2017 PROJECTS\LOT 1251\LOT 1251-AD.pln
GSPublisherVersion 286.26.100.67
165 m2
D.P
D.P
D.P
D.P
S.D.
EF
EF
EF
D.P
EF
EF
S.D.
D.P
D.P
FFL+100.20
FFL+100.14
0 m2
25 m2
7 m2
6 m2
8 m2
3 m2
3 m2
LETTER BOX350DX350WX600H
500mm MINIMMGARDENBED BETWEEN
BOUNDARY & DRIVEWAY
RAISED PAVEMENT
1.8m HIGH CAPPED PRE-COATEDMETAL SHEETING PANELS FENCEWITH EXPOSED POTS(Eg. COLORBOND) IN 'GREY RIDGECOLOUR OR COLOURED TO MATCH
1.8m HIGH CAPPED PRE-COATEDMETAL SHEETING PANELS FENCEWITH EXPOSED POTS(Eg. COLORBOND) IN 'GREY RIDGECOLOUR OR COLOURED TO MATCH
RETURN FENCE TO BE 1.8mHIGH CAPPED PRE-COATEDMETAL SHEETING PANELS FENCEWITH EXPOSED POTS TO FINISH1m BEHIND BUILDING LINE
1.8m HIGH CAPPED PRE-COATEDMETAL SHEETING PANELS FENCEWITH EXPOSED POTS(Eg. COLORBOND) IN 'GREY RIDGECOLOUR OR COLOURED TO MATCH
ACER PLAMATUM ( ADVANCED TREE(s) AT LEAST5.0m HEIGHT AT MATURITY)
ACER PLAMATUM ( ADVANCED TREE(s) AT LEAST5.0m HEIGHT AT MATURITY)
POA SIEBERIANA(SMALL SHRUBS)
POA SIEBERIANA(SMALL SHRUBS)
COMBINATION OF LAWNAND VEGETATION
EXPOSED AGGREGATECONCRETE DRIVEWAY
CR
OS
SO
VER
FOO
TPA
TH
EASE
MEN
T @ 2
m
CR
OS
SO
VER
FOO
TPA
TH
GRASS- LONGPURPLE FLAT
GRASS- LONGPURPLE FLAT
AS OF 1.09.17
AS OF 1.09.17
AS
OF
1.09
.17
AS
OF
1.09
.17
PROPOSED NEW DWELIINGLOT 1251SITE : 512m2
N
LANDSCAPE PLAN1:200
Plot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
LANDSCAPE PLAN
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-04
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT
15/06/2018
I:\SEAGATE FILES\OMAXE HOMES 2017 PROJECTS\LOT 1251\LOT 1251-AD.pln
GSPublisherVersion 286.26.100.67
A
General Notes
o All materials and work practices shall comply with, but not limited to theBuilding Regulations 2006, the Building Code of Australia 2010 and allrelevant current Australian Standards (as amended) referred to therein.
o Glazing, including safety glazing, shall be installedto a size, type andthickness so as to comply with: BCA Part 3.6 for Class 1 and 10 Buildingswithin a design wind speed of not more than N3; and BCA Part B1.4 forClass 2 and 9 Buildings.
o Waterproofing of wet areas, being bathrooms, showers, shower rooms,laundries, sanitary compartments and the like shall be provided inaccordance with AS 3740 -2004: Waterproofing of Wet Areas in ResidentialBuildings.
o These Drawings shall be read in conjunction with any House EnergyRating (HER) report and shall be constructed in accordance with thestamped plans endorsed by the accredited Thermal PerformanceAssessor without alteration.
o Step sizes (other than for spiral stairs) to be:
- Risers (R) 190mm maximum and 115mm minimum- Going (G) 355mm maximum and 240mm minimum- 2R + 1G = 700mm maximum and 550mm minimum-with less than 125mm gap between open treads.
o All treads, landings and the like to have non slip finish or suitable non -skidstrip near edge of nosing.
o Provide balustrades where change in level exceeds 1000mm above thesurface beneath landings, ramps and/or treads. Balustrades (other thantensioned wire balustrades) to be:- 1000mm min. above finished surface level of balconies, landings or thelike, and- 865mm min. above finished surface level of stair nosing or ramp, and -vertical with less than 125mm gap between, and- any horizontal element within the balustrade between 150mm and760mm above the floor must not facilitate climbing where changes in levelexceeds 4000mm above the surface beneath landings, ramps and/ortreads.
Wire balustrade construction to comply with BCA2010 Volume 2 Part3.9.2.3 for Class 1 and 10 Buildings and BCA 2010 Volume 1 Part D2.16for other Classes of Buildings.
o Hand rails to be 865mm minimum above stair nosing and landings.
o Window sizes nominated are nominal only. Actual size may vary accordingto manufacturer. Windows to be flashed all around.
o Where the building (excludes a deta ched Class 10) is located in a termiteprone area, the area to underside of building and perimeter is to betreated against termite attack.
o Concrete stumps:- up to 1400mm long to be 100mm x 100mm (1 No. H.D. Wire)- 1401mm to 1800mm long to be 100m m x 100mm (2 No. H.D. Wires)- 1801mm to 3000mm long to be 125mm x 125mm (2 No. H.D. Wires)- 100mm x 100mm stumps exceeding 1200mm above ground level to
be braced where no perimeter base brickwork provided.
o For buildings in marine or other exposure environments shall havemasonry units, mortar and all built in components and the like complyingwith the durability requirements of Table 5.1 of AS3700-2001 MasonryStructures.
o All stormwater to be taken to the legal point of discharge to the RelevantAuthorities approval.
o These drawings shall be read in conjunction with all relevant structural andall other consultants ’ drawings/details and with any other writteninstructions issued in the course of the contract.
o Site plan measurements in me tres – all other measurements in millimetresu.n.o.
o Figured dimensions take precedence over scaled dimensions.
o The Builder shall take all steps necessary to ensure the stability andgeneral water tightness of all new and/or existing structures during allworks.
o The Builder and Subcontractors shall check and verify all dimensions,setbacks, levels and specifications and all other relevant documentationprior to the commencement of any works. Report all discrepancies to thisoffice for clarification.
o Installation of all services shall comply with the respective supply authorityrequirements.
o The Builder and Subcontractor shall ensure that all stormwater drains,sewer pipes and the like are located at a sufficient distance from anybuildings footing and/or slab edge beams so as to prevent generalmoisture penetration, dampness, weakening and undermining of anybuilding and its footing system.
o These plans have been prepared for the exclusive use by the Client ofMcam Building Design P/L (‘The Designer’) for the purpose expresslynotified to the Designer. Any other person who uses or relies on theseplans without the Designer ’s written consent does so at their own risk andno responsibility is accepted by the Designer for such use and/or reliance.
o The approval by this office of a substitute material, work practice, variationor the like is not an authorisation for its use or a contract variation. Anysaid variations must be accepted by all parties to the agreement andwhere applicable the Relevant B uilding Surveyor prior to implementing thesaid variation.
STORMWATER
100 mm DIA. Class 6 UPVC stormwater line laid to a minimum grade of1:100 and connected to the legal point of stormwater discharge. Provideinspection openings at 9000mm C/C and at each change of direction.
The cover to underground stormwater drains shall be not less than– 100mm under soil– 50mm under paved or concrete areas– 100mm under unreinforced concrete or paved driveways– 75mm under reinforced concrete driveways. TIMBER FLOOR WALL AND ROOF FRAMING
ALL WORKS TO BE CARRIED OUT IN STRICTACCORDANCE WITH AS 1684 "TIMBER FRAMINGCODE'& SUPPLEMENTARY TABLES
*REFER ENGINEER'S CIVIL PLAN
SAFETY GLAZINGSAFETY GLAZING TO BE USED IN FOLLOWING CASES:-- ALL ROOMS - WITHIN 500mm VERTICAL FROM FLOOR- BATHROOMS - WITHIN 1500mm VERTICAL FROM THE BATH BASE- LAUNDRY - WITHIN 1200mm VERTICAL FROM FLOOR AND/ OR WITHIN 300mm VERTICAL OF TROUGH- ENSUITE - AS PER BATHROOM- SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS
PLASTERPROVIDE 10mm THICK PLASTERBOARD TO WALLS AND10mm THICK PLASTER TO CEILING. ALL WET AREASSHALL HAVE AN APPROVED 10 THICK WATERPROOFPLASTERBOARD OR HARDIES VILLABOARD INSTALLED INSTRICT ACCORDANCE WITH MANU. INSTRUCTIONS &SPECIFICATIONS
SMOKE ALARMSSMOKE ALARMS SHOWN ON PLANS ARE TO BEPROVIDED & INSTALLED IN ACCORDANCE WITH A.S.3786-1993. AND UNLESS INSTALLED IN AN EXISTINGPART OF A CLASS 1,2,3 OR PART OF A BUILDING THESMOKE ALARMS SHELL BE HARD WIRED WITHBATTERY BACKUP.
STORMWATER90mm DIAM. CLASS 6 UPVC STORMWATER LINE LAID TOA MINIMUM GRADE OF 1:100 AND CONNECTED TO THELEGAL POINT OF DISCHARGE AS DIRECTED BY CITYENGINEER. PROVIDE INSPECTION OPENINGS AT9000mm C/C & AT EACH CHANGE OF DIRECTION.THE COVER TO UNDERGROUND STORMWATER DRAINSSHALL BE NOT LESS THAN. - 100mm UNDER SOIL - 50mm UNDER PAVED OR CONC. AREAS - 100mm UNDER UNREINFORCED CONC. OR PAVED DRIVEWAYS - 75mm UNDER REINFORCED CONC. DRIVEWAYS
SPECIFICATIONS
SOIL CLASSIFICATIONTHESE PLANS SHALL BE READ IN CONJUNCTION WITHTHE SOIL REPORT.
FOOTINGS TO BE FOUNDED AT THE MINIMUM DEPTHSINDICATED IN THE SOIL REPORT. THE H.G.F.L.RECOMMENDS THAT FOOTINGS/ SLABS & DRAINAGE TOBE DESIGNED & INSPECTED BY AN ENGINEER TOSATISFY THEIR REQUIREMENTS.
BRICK VENEER WALLSCOMPLY WITH AS 3700 MASONRY IN BUILDINGS & AS2904 DAMP PROOF COURSES & FLASHING. USE BRICKSAS SELECTED AND M3 (1:1:6) MORTAR. USE FACE FIXINGCAVITY TIES TO AVOID HOLES IN FOIL INSULATIONMATERIAL
PROVIDE MASONRY CONTROL JOINTS ASRECOMMENDED BY SOIL TEST REPORT AND IN STRICTACCORDANCE WITH TECHNICAL NOTE CN9 OF CEMENT& CONCRETE ASSOCIATION OF AUST.
EXCAVATIONEXCAVATE FOOTINGS & DRAINS AS SHOWN. KEEPEXCAVATIONS DRY & BACKFILL WITH APPROVEDMATERIALS FREE OF ANY BUILDING DEBRIS
CONCRETEALL CONCRETE & SLABS WORK SHALL COMPLY WITHAS 2870.1-1988 "RESIDENTIAL SLAB & FOOTINGS" PARTONE: CONSTRUCTION IN THE ABSENCE OF ENGINEER'SDRAWINGS OR COMPUTATIONS
REFER TO ENGINEER'S DETAILSFLOOR JOISTS
REFER TO ENGINEER'S DETAILSLINTELS
F1739002700270090 x 70
F521002700270090 x 90
F515002700270090 x 70
F59002400240090 x 45STUDS -AT SIDESOF THEOPENINGS
F5450-300090 x 70
F5450-270090 x 45
F5600-240090 x 45STUDS COMMON
F5-60060090 x 70TOP ANDBOTTOM PLATE
SIZES FOR LOWER STOREY OF 2 STOREY CONSTRUCTION
TIMBER FRAMINGSCHEDULE
STRESS GRADE F17 REFERS TO SEASONED HARDWOODSTRESS GRADE F8 REFERS TO UNSEASONED HARDWOODSTRESS GRADE F7 REFERS TO UNSEASONED OREGONSTRESS GRADE F5 REFERS TO SEASONED RADIATA PINE
ROOF BATTENS
BRACING
F8900900-75 X 38
METAL STRAP - REFER A.S. 1684
F51350-60070 x 35NOGGINGS
F17--3600290 X 45
F17--3200240 X 45
F17--3000240 X 35
F17--2400190 x 35
F17--1900140 X 35
F17--130090 x 35LINTELS(REFER TRUSSDESIGN)
F515003000300090 x 90
F527002700270090 x 90
F518002700270090 x 70
F530002400240090 x 70
F511502400240090 x 45STUDS-AT SIDESOF OPENING
F54503000300090 x 45
F56002700270090 x 35
F56002400240090 x 35STUDS-COMMON
F5-60060090 x 45TOP PLATE
F5-60060090 x 45BOTTOM PLATE
SIZES FOR SINGLE STOREY AND UPPER STOREY OF 2 STOREY CONSTRUCTION
SIZEMEMBER MA
XIM
UM
STR
ES
S G
RA
DE
MA
XIM
UM
SP
AC
ING
CO
NT.
OVE
R 2
SP
AN
S
SU
PP
. AT
2P
OIN
TS
EFFECTIVE ROOF LENGTH - 12000
CEILING HEIGHT - 3000
MAX. SPANFRAMING TIMBER
600510
620
600 SERIESSTANDARD
STANDARD
PARTICLEBOARD SHEET FLOORING19 THICK RADIATA PINE
19 THICK VICTORIAN HW
JOIST SPACINGGRADEFLOORING MATERIAL
Plot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
GENERAL NOTES
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-05
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT
15/06/2018
I:\SEAGATE FILES\OMAXE HOMES 2017 PROJECTS\LOT 1251\LOT 1251-AD.pln
GSPublisherVersion 286.26.100.67
B
820
820
820
820
820
820
820
820
720 720
820
720
720
W-03
W-02
W-01
W-13W-11 W-12
W-04W-06W-07 W-05
W-08
W-09
W-15W-14W-10
F
D.P
METERBOXHWS
D.P
D.P
D.P
S.D.
EF
EF
EF
D.P
EF
EF
S.D.
D.P
D.P
240 4,086BED 4
90 8,061FAMILY
90 3,914THEATRE
90 2,205PDR
90 4,922MASTER ENS.
240
240 1,455WIR
901,455WIR
90996 90 8,061
FAMILY90 3,914 90 1,215
SH
90900WC
90 4,922 240
230 3,946 240 6,971KITCHEN/ MEALS 90
1,000REF
902,074WIP
90 1,750STORE
90 2,115ENS.
180 4,922WIR
240
1,347 2,100 1,430 2,260 1,670 2,000 1,910 1,800 830 900 470 1,800 5,510
90 8,061FAMILY
180 5,419 3,547 240
240 1,455WIR
901,455WIR
90996
901,350 350 3,557
BULKHEAD350 2,453 90 2,690 300
60090 1,829 3,547 240
384240
240 3,000 90 3,513 90 3,000 90 76390
1,000 90510
90 3,590 90
240 3,000BED 3
90 1,500WC
90833
901,000
L90 3,000
BED 290 763 90 1,600 90 3,590 90
90 3,513BATH
90 3,000BED 2
90 763 90 1,600L'DRY
90 3,590LOUNGE
90 6,000GARAGE
240 1,781 580
6,110 700 590 1,800 1,790 1,450470
600
4,176 19,852 732
624
16,006 6,480 2,361
1,19
060
01,
578
2,00
047
01,
300
822
4,80
050
0
240
1,97
8S
TOR
E90
3,50
0TH
EA
TRE
901,
508
180
4,18
3LO
UN
GE
240
240
2,48
7E
NS
.90
1,50
0W
C/ S
H
901,
191
PD
R
901,
510
180
5,64
2G
AR
AG
E24
0
240
1,97
8W
IP90
3,50
0TH
EA
TRE
901,
300
388
4,18
4LO
UN
GE
240
240
1,27
8W
IR18
03,
900
MA
STE
R E
NS
.90
1,60
0E
NTR
Y90
5,64
2G
AR
AG
E24
0
5,83
81,
300
6,12
2
13,2
60
240
7,74
0FA
MIL
Y/ M
EA
LS/ K
ITC
HE
N90
2,00
0R
OB
E90
1,61
0W
IL24
0
240
7,74
0FA
MIL
Y/ M
EA
LS/ K
ITC
HE
N90
1,24
6P
AS
S.
9041
390
1,86
1B
ATH
TA
B24
0
240
3,00
0B
ED
490
1,30
0W
IR90
3,40
0B
ED
324
0
950
2,46
024
01,
190
1,80
02,
270
1,80
01,
300
3,65
08,
360
1,25
0
1,20
03,
959
710
3,000 1,200
350
903,
700
BE
D 2
240
240
3,41
024
03,
000
901,
300
WIR
9094
690
900
WC
901,
374
BA
TH24
0
13,2
60
849 8493,225
573
830
24,847
24,847
230
3,42
0A
LFR
ES
CO
240
600
388 300
180
230
230
1,20
01,
200
470
180
410
350
350 3,557
1,200853
18039
390 1,
120
LIN
EN
902,
490
L'D
RY
240
240
730
RE
F
1,350
2,453
1,950740
FFL+100.200
FFL+100.137
CJCJ
CJCJ
CJ
CJ
CJ
CJ
CJ
CJCJ
CJCJCJCJ
FAMILY
KITCHEN
THEATRE
MASTERENSUITE
DOUBLEGARAGE
ENTRYPORCH
WIR
PDR
WC
ENSUITEWIPALFRESCO
BED 4
BED 3 WC LINEN
BATHBED 2
ROBE
WIL
LIN
EN
LAUN
DRY
LOUNGE
149mmSTEPDOWN( CONC.)
149mmSTEPDOWN( CONC.)
STEPDOWN( CONC.)
ROBE
STORE
WIR
WIR
BULKHEAD
BULKHEAD
PASSAGE
D-1
D-2
D-3 D-4
Toughened glass and non-combustible architraves
Toughened glass and non-combustible architraves
C
A
D
B
YY
RG
W
DW
RG
MEALS
N
FLOOR PLAN1:100
Plot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
FLOOR PLAN
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-06
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT
15/06/2018
I:\SEAGATE FILES\OMAXE HOMES 2017 PROJECTS\LOT 1251\LOT 1251-AD.pln
GSPublisherVersion 286.26.100.67
D
2,70
0
2,76
3
2,70
0
400
400
2,75
7
450450
91
500
SELECTED CONCRETETILED ROOF@ 22.5O PITCH SELECTED CONCRETE
TILED ROOF@ 22.5O PITCH
FEATURE RENDERED
CUTT
TIMBER HORIZONTALSLATS FEATURE TO FRONT PORCH
CL
FL
CL
FL
POR
. OPE
NIN
G
(GAR
. FLR
-LIN
T.)
EAVE
EAVE
TOP
OF
PIER
RAISEDPORCH CL
TITL
E BO
UN
DAR
Y
2,35
7
FEATURE TILED PORCHCOLUMNS AS SELECTED
RENDERED BRICK WORK
48000mm WIDE X 2400MMHIGH SECTIONAL LIFT DOOR
RENDERED PORCH COLUMNSAS SELECTED
NGLNGL
2,70
050
0
2,70
0
2,75
7
2,35
7
89 58
3,17
6
SOLAR PANEL
SELECTED CONCRETETILEDROOF@ 22.5O PITCH
SELECTED CONCRETETILEDROOF@ 22.5O PITCH
TIMBER HORIZONTALSLATS FEATURE TO
FRONT PORCH
CUTTFILL
CL
FL
CL
FL
TOP
OF
PIER
RAISEDPORCH CL
3.2m MAX. HEIGH WALLON BOUNDARY
FACE BRICKWORK
ALLUMINIUM WINDOWS TOSIDE & REAR ELEVATIONSUNLESS NOTED OTHERWISE
RENDERED PORCH COLUMNSAS SELECTED
NGLNGL
NEXTGENBUILDING
SURVEYORS PTYLTD
BUILDINGPERMIT
ISSUED 27/06/2016
NUMBER BS-U 42299-20160351/0
RELEVANT BUILDING SURVEYOR
Bang Quach
BS-U 42299
ELEVATION - A1:100
ELEVATIONS - B1:100
Plot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
ELEVATIONS
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-07
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT
15/06/2018
I:\SEAGATE FILES\OMAXE HOMES 2017 PROJECTS\LOT 1251\LOT 1251-AD.pln
GSPublisherVersion 286.26.100.67
D
2,70
0
2,70
0
450
500
SELECTED CONCRETETILED ROOF@ 22.5O PITCH
SELECTED CONCRETETILED ROOF@ 22.5O PITCH
ALLUMINIUM WINDOWS TOSIDE & REAR ELEVATIONS
UNLESS NOTED OTHERWISE
FL
CL
HWS
MB
EAVE
FL
CL
RAISEDPORCH CL
FACE BRICKWORK FEATURE TILED PORCH COLUMNSAS SELECTED
FACE BRICKWORK
NGL
NGL
2,70
0
2,70
0
2,76
3
136 46
FACE BRICKWORK
370X370mm BRICK PIERS
ALUMINIUM SLIDINGSTACKING DOOR
FILLFILL
SOLAR PANELALLUMINIUM WINDOWS TOSIDE & REAR ELEVATIONSUNLESS NOTED OTHERWISE
SELECTED CONCRETETILEDROOF@ 22.5O PITCH
SELECTED CONCRETETILEDROOF@ 22.5O PITCH
FL
CL
FL
CL
EAVE
(GAR
. FLR
-CEI
L.)
NGL NGL
NEXTGENBUILDING
SURVEYORS PTYLTD
BUILDINGPERMIT
ISSUED 27/06/2016
NUMBER BS-U 42299-20160351/0
RELEVANT BUILDING SURVEYOR
Bang Quach
BS-U 42299
ELEVATION - D1:100
ELEVATION - C1:100
Plot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
ELEVATIONS
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-08
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT
15/06/2018
I:\SEAGATE FILES\OMAXE HOMES 2017 PROJECTS\LOT 1251\LOT 1251-AD.pln
GSPublisherVersion 286.26.100.67
B
2,70
0
2,70
0
PLASTERBOARD TO INTERNALWALL AND CEILING LINING
SELECTED CONCRETETILED ROOF@ 22.5O
PITCH
SELECTED CONCRETETILED ROOF@ 22.5OPITCH
KITCHENLAUNDRY
LINEN ENTRY FAMILY
TITL
E BO
UN
DAR
Y
CONCRETE SLAB AS PERENGINEERINGCONSULTANTS DRAWINGS& SPECS.
PRE-FABRICATED TIMBER ROOF TRUSSESAT 600 ACCORDANCE, WITH MANUFACTURER'S SPECIFICATION &RECOMMENDATIONS
CL
FL
CL
FL
PRIOR CONSTRUCTION, CHECK ENGINEERS SPECIFICATIONS FOREXACT WAFFLE POD SLAB CONSTRUCTION DETAILS
NEXTGENBUILDING
SURVEYORS PTYLTD
BUILDINGPERMIT
ISSUED 27/06/2016
NUMBER BS-U 42299-20160351/0
RELEVANT BUILDING SURVEYOR
Bang Quach
BS-U 42299
NEXTGENBUILDING
SURVEYORS PTYLTD
BUILDINGPERMIT
ISSUED 27/06/2016
NUMBER BS-U 42299-20160351/0
RELEVANT BUILDING SURVEYOR
Bang Quach
BS-U 42299
timber Framing Code AS 1684.4
Provide timber trussed roof as permanufacture design and layout.
Provide Waffle Pod Slab as per engineersspecification and computation. (refer toengineers slab drawings)
All timber construction to comply with Lighttimber Framing Code AS 1684.4
SECTION- Y-Y1:100
Plot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
SECTION
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-09
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT
15/06/2018
I:\SEAGATE FILES\OMAXE HOMES 2017 PROJECTS\LOT 1251\LOT 1251-AD.pln
GSPublisherVersion 286.26.100.67
CEILING HEATING DUCT OUTLET (APPX. LOCATION)
RETURN AIR (IN WALL)
THERMOSTAT
COOLING UNIT(APPX. LOCATION)EXACT LOCATION SUBJECT TO CONTRACTORS DISCRETION
HEATING UNIT Inc. DOUBLE P.POINT & LIGHT POINT(APPX.LOCATION) EXACT LOCATION SUBJECT TO CONTRACTORSDISCRETION
EVAP. COOLING DUCT OUTLET(APPX. LOCATION)
AIR-CONDTIONER UNIT Inc. ISOLATOR (APPX. LOCATION)EXACT LOCATION SUBJECT TO CONTRACTORS DISCRETION
GROUND FLOOR CEILING SPEAKER GRILLE LOCATED UNDERFIRST FLOOR BATH/SPA WASTE (APPX. LOCATION)
CEILING FAN
CEILING FAN WITH LIGHT
LED SPOTLIGHT - SINGLE (HEIGHT VARIES)
LED SPOTLIGHT - DOUBLE (HEIGHT VARIES)
DIMMER LIGHT SWITCHD
HEATER/FAN (NO LIGHT)
HEATER/FAN & LIGHT
1200 FLUORO - DOUBLE
MOTION SENSOR
JUNCTION BOX (Height Varies)
1200 FLUORO - SINGLE
1200
1200
JB
2 GLOBE
4 GLOBE - HEATER/FAN & LIGHT -
F
METERBOXHWS
S.D.
EF
EF
EF
EF
EF
METERBOX
EF
S.D.
TP
WP
WP
TV
TV
TV
TV
TV
WP WP
WP WP
S.D.
FAMILY
KITCHEN
THEATRE
MASTERENSUITE
DOUBLEGARAGE
ENTRY PORCH
WIR
PDR
WC
ENSUITEWIP
ALFRESCO
BED 4
BED 3 WC LINEN
BATHBED 2
WIR
WIL
LIN
EN
LAUN
DRY
LOUNGE
STORE
ELECTRICAL LEGEND
SINGLE GPO AT 300mm
DOUBLE GPO AT 300mm
SINGLE GPO AT 1050mm
DOUBLE GPO AT 1050mm
SINGLE GPO AT 1500mm
DOUBLE GPO AT 300mm
BATTEN LIGHT HOLDER
LED DOWNLIGHT FIXED
FLURO WALL LIGHT
MOVEMENT SENSOR
METER BOX
EXHAUTS FAN
SMOKE ALARM TO AS3786
T.V. OUTLET HIGH
TELEPHONE POINT
SINGLE ATER PROOF GPO AT 300mm
DOUBLE WATER PROOF GPO AT 300mm
T.V. OUTLET LOW
SINGLE GPO AT Ceiling
2-WAY LIGHT CIRCUIT
LIGHT CIRCUIT
LED DOWNLIGHT GIMBLE
FLURO LIGHT TUBE
FLOOD LIGHT WALL
SINGLE GPO AT Ceiling
RG
W
DW
RG
MEALS
Pag
e3
AIR LEAKAGE
- 3.12.3.1 – All chimneys and flues to be fitted with self closing dampers.
- 3.12.3.2 – All roof lights must be sealed or capable to be sealed.
- 3.12.3.3 – All external windows and doors are to be fitted with weather-strips.
- 3.12.3.4 – Self-closing damper to all the exhaust fans.
- 3.12.3.5 – Seal any avenues of air leakage through the building envelope by caulking, skirting,
architraves, cornices or the like.
LIGHTING
- Downlights have been included in this assessment: Yes/
- All lighting in the dwelling will be designed at 5W/m2 or better.
- All lighting on the verandah, balcony will be designed at 4W/m2 or better.
- All lighting in the garage will be designed at 3W/m2 or better. - Artificial lighting around the perimeter of the building must be controlled by a daylight sensor.
ARTIFICIAL LIGHTING AND CEILING PENETRATION CALCULATIONS
Dwelling Watts Number Total Watts Area Maximum W/m2 Allowable Watts
LED Downlight 11 39 429
Batten Holder 15 9 135
0
0
0
Porch/Alfresco Watts Number Total Watts Area Maximum W/m2 Allowable Watts
LED Downlight 11 3 33
0
0
Garage Watts Number Total Watts Area Maximum W/m2 Allowable Watts
Batten Holder 15 2 30
0
0
Total Watts 627.0 Allowable Watts 1373.0
Compliance
Note: All external lighting must be controlled by a daylight sensor for have a minimum efficiency of 40 lumens per watt.
Penetration Type Area (m2) Number Area Penetration Area Dwelling Area Penetration Percentage
Downlight 0.02 0
Exhaust Fan 0.02 0
Rangehood 0.02 0
0
0
0
6-Star Required Insulation
Updgraded Insulation
0.000 234.0 0.000
PASS
Lighting
Insulation Penetration
234.0 5.0 1170.0
23.0 4.0 92.0
37.0 3.0 111.0
Pag
e3
AIR LEAKAGE
- 3.12.3.1 – All chimneys and flues to be fitted with self closing dampers.
- 3.12.3.2 – All roof lights must be sealed or capable to be sealed.
- 3.12.3.3 – All external windows and doors are to be fitted with weather-strips.
- 3.12.3.4 – Self-closing damper to all the exhaust fans.
- 3.12.3.5 – Seal any avenues of air leakage through the building envelope by caulking, skirting,
architraves, cornices or the like.
LIGHTING
- Downlights have been included in this assessment: Yes/
- All lighting in the dwelling will be designed at 5W/m2 or better.
- All lighting on the verandah, balcony will be designed at 4W/m2 or better.
- All lighting in the garage will be designed at 3W/m2 or better. - Artificial lighting around the perimeter of the building must be controlled by a daylight sensor.
ARTIFICIAL LIGHTING AND CEILING PENETRATION CALCULATIONS
Dwelling Watts Number Total Watts Area Maximum W/m2 Allowable Watts
LED Downlight 11 39 429
Batten Holder 15 9 135
0
0
0
Porch/Alfresco Watts Number Total Watts Area Maximum W/m2 Allowable Watts
LED Downlight 11 3 33
0
0
Garage Watts Number Total Watts Area Maximum W/m2 Allowable Watts
Batten Holder 15 2 30
0
0
Total Watts 627.0 Allowable Watts 1373.0
Compliance
Note: All external lighting must be controlled by a daylight sensor for have a minimum efficiency of 40 lumens per watt.
Penetration Type Area (m2) Number Area Penetration Area Dwelling Area Penetration Percentage
Downlight 0.02 0
Exhaust Fan 0.02 0
Rangehood 0.02 0
0
0
0
6-Star Required Insulation
Updgraded Insulation
0.000 234.0 0.000
PASS
Lighting
Insulation Penetration
234.0 5.0 1170.0
23.0 4.0 92.0
37.0 3.0 111.0
ELECTRICAL PLAN1:100
NOTE:DOWN LIGHTS1 - ALL DOWN LIGHTS MUST BE LED TYPE.2- IF INSTALLED WHERE OTHER NON CEILINGPENETRATIONG FITTINGS ARE SPECIFIED, FITTINGS MUSTHAVE AN AN APPROVED NON VENTILATED COVER.Approved to AS/NZS 5110:2012 non-ventilated covers allowfor the insulation to be closely installed to the sides andenables an R-value above the LED Luminaire via the materialof the Downlight cover itself.
BPlot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
ELECTRICAL PLAN
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-11
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT
15/06/2018
I:\SEAGATE FILES\OMAXE HOMES 2017 PROJECTS\LOT 1251\LOT 1251-AD.pln
GSPublisherVersion 286.26.100.67
A
WINDOW SCHEDULEID
W-01
W-02
W-03
W-04
W-05
W-05
W-06
W-07
W-08
W-09
W-10
ELEVATION W x H Size
600×2,100
600×2,100
1,400×2,100
600×1,800
600×1,800
600×1,940
1,800×1,200
700×900
1,800×1,200
1,800×1,200
2,100×1,200
HEAD HT
2,340
2,340
2,340
2,100
2,100
2,340
2,340
2,300
2,340
2,340
2,200
TYPE
AWNING
AWNING
FIXE
AWNING
AWNING
EMPTY
SLIDING
AWNING
SLIDING
SLIDING
SLIDING
FRAME
ALUMINIUM
ALUMINIUM
ALUMINIUM
ALUMINIUM
ALUMINIUM
EMPTY
ALUMINIUM
ALUMINIUM
ALUMINIUM
ALUMINIUM
ALUMINIUM
COMMENTS
FEATURE HOLE IN THE LOUNGE
TOUGHENED GLASS AND NON-COMBUSTIBLE ARCHITRAVES
WINDOW SCHEDULEID
W-11
W-12
W-13
W-14
W-15
ELEVATION W x H Size
2,260×2,200
2,000×600
1,800×600
900×900
1,800×510
HEAD HT
2,340
1,600
1,600
2,340
2,340
TYPE
SLIDING
AWNING
AWNING
FRAME
ALUMINIUM
ALUMINIUM
ALUMINIUM
ALUMINIUM
ALUMINIUM
COMMENTS
TOUGHENED GLASS AND NON-COMBUSTIBLE ARCHITRAVES
DOOR SCHEDULEID
D-1
D-2
D-3
D-4
ELEVATION W x H Si...
1,200×2,340
2,460×2,340
1,450×2,100
820×2,340
HE...
2,340
2,340
2,100
2,340
TYPE
SLIDING
SLIDING
FRAME
TIMBER
ALUMINIUM
ALUMINIUM
COMMENTS
DESIGNED1200 ENTRY DOOR
ALUMINIUM FRAMED STACKERSLIDING DOUBLE GLAZED DOORS
ALUMINIUM FRAMED SLIDINGGLASS DOORS
EXTERNAL 820 GARAGE DOOR
Plot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
WINDOW & DOOR SCHEDULE
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-12
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT
15/06/2018
I:\SEAGATE FILES\OMAXE HOMES 2017 PROJECTS\LOT 1251\LOT 1251-AD.pln
GSPublisherVersion 286.26.100.67
A
25 mm
Toe Under
(R)
RISER
190
max
.
'R'
Stairs 190
Max.
'G'
(2R+G)
Min.
550
QUANTITY
250
Min.
250 min.
355
Max.
115
Min.
700
Max.
GOING
(G)
GOING AND RISERS SHALL NOT EXCEED FOLLOWING:
275 x 50 TREADS
250 x 50 STRINGER
OPENINGS WITHINTHE OPEN STAIR TOBE MAX. OF 125mm
TREADS TO HAVE ANON-SKID STRIP NEAREDGE OF NOSING
HANDRAILS SHALL BE PROVIDED ALONG EACH SIDE OF ASTAIRWAY IF THE WIDTH OF THE STAIRWAYS EXCEEDS2000mm.
THE WIDTH OF A STAIR (MEASURED CLEAR OF HANDRAILSAND OBSTRUCTIONS) SHALL BE CONSTANT.BALUSTRADES TO BE CONSTRUCTED IN A WAY THAT ANYOPENINGS DOES NOT PERMIT A 125mm SPHERE TO PASSTHROUGH IT AND FOR BOTTOM RAILS THE SPACE IS TESTEDABOVE THE NOSINGS.
DO-7 GLAZING REQUIREMENTS FOR BATHROOMS ETC
D-01 TYPICAL LOCATIONS OF CONTROL JOINTS
D-02 TYPICAL CONTROL JOINTS DETAILS
D-O4 INSTALLTIN OF SILL & HEAD FLASHINGS
D-O3 FLASHINGS TO EXTERNAL WALL OPENINGS
Plot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
DETAILS
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-13
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT
15/06/2018
I:\SEAGATE FILES\OMAXE HOMES 2017 PROJECTS\LOT 1251\LOT 1251-AD.pln
GSPublisherVersion 286.26.100.67
A
Lot 1251 Clifton Circuit, Tarneit
12/7/2017
Thermal Assessment
Pag
e2
Thermal Energy Report Building Specification Requirements
Star Rating: 6.0 stars
The below items have been added to the proposed building in order to gain the given rating as per the
attached report. Please read these items in conjunction with the attached report and plans as stamped and
endorsed.
Please note: the below items are minimum requirements that must be incorporated and installed correctly for
the building to achieve the rating given. Please ensure that all minimum B.C.A requirements are met as
required.
Specification Inclusion List as follows;
CEILINGS
- R5.0 bulk insulation in the ceiling of the roof excluding the Garage
FLOORS
- No insulation required
WALLS
- R1.5 bulk insulation with 1 layer of breathable membrane wrap to all the external walls excluding the Garage
- R1.5 bulk insulation in the internal Garage walls
WINDOWS
- D1 is to be timber framed single glazed clear glass with a minimum U- value & SHGC as listed below
WINDOW TYPE U-VALUE SHGC
Casement 5.4 0.56
- All other windows and glazed doors are to be aluminium single glazed clear glass with a minimum U- value & SHGC as listed below
WINDOW TYPE U-VALUE SHGC
Awning, Casement 6.7 0.57
Fixed, Sliding 6.7 0.70
Pag
e3
AIR LEAKAGE
- 3.12.3.1 – All chimneys and flues to be fitted with self closing dampers.
- 3.12.3.2 – All roof lights must be sealed or capable to be sealed.
- 3.12.3.3 – All external windows and doors are to be fitted with weather-strips.
- 3.12.3.4 – Self-closing damper to all the exhaust fans.
- 3.12.3.5 – Seal any avenues of air leakage through the building envelope by caulking, skirting,
architraves, cornices or the like.
LIGHTING
- Downlights have been included in this assessment: Yes/
- All lighting in the dwelling will be designed at 5W/m2 or better.
- All lighting on the verandah, balcony will be designed at 4W/m2 or better.
- All lighting in the garage will be designed at 3W/m2 or better. - Artificial lighting around the perimeter of the building must be controlled by a daylight sensor.
ARTIFICIAL LIGHTING AND CEILING PENETRATION CALCULATIONS
Dwelling Watts Number Total Watts Area Maximum W/m2 Allowable Watts
LED Downlight 11 39 429
Batten Holder 15 9 135
0
0
0
Porch/Alfresco Watts Number Total Watts Area Maximum W/m2 Allowable Watts
LED Downlight 11 3 33
0
0
Garage Watts Number Total Watts Area Maximum W/m2 Allowable Watts
Batten Holder 15 2 30
0
0
Total Watts 627.0 Allowable Watts 1373.0
Compliance
Note: All external lighting must be controlled by a daylight sensor for have a minimum efficiency of 40 lumens per watt.
Penetration Type Area (m2) Number Area Penetration Area Dwelling Area Penetration Percentage
Downlight 0.02 0
Exhaust Fan 0.02 0
Rangehood 0.02 0
0
0
0
6-Star Required Insulation
Updgraded Insulation
0.000 234.0 0.000
PASS
Lighting
Insulation Penetration
234.0 5.0 1170.0
23.0 4.0 92.0
37.0 3.0 111.0
Pag
e4
GENERAL NOTES
The building materials listed in these reports are the minimum requirement needed to achieve the
listed Star Rating required. All State, Territory & Federal; building standards and regulations still
need to be adhered to.
All insulation is to be supplied and installed as per Australian Standards & required regulations.
Holes, rips and penetrations through Sisalation, Reflective Foils and Insulation Wraps must be
sealed or repaired.
Insulation batts and blankets are not to be compressed when being installed and all voids must
be completely filled.
Insulation is to be laid over all manhole lids, ensuring a continuous layer of insulation. No ceiling
penetrations have been entered for man holes. Glass window and glass door sizes are not to be increased; it will change the rating of this
report.
Total System 'U-Value' - The glass windows and/or glass doors supplied must equal and/or can
be less than the 'U-Values" listed in this report.
Total System 'SHGC' - The glass windows and/or glass doors supplied should not be greatly
reduced or increased (a 5% variance is acceptable) than the Total System 'SHGC' Values listed in
this report.
All downlights and exhaust fans that penetrate the ceiling must be sealed.
If any details are changed on this project as listed above then this report may be invalid and will
need to be re assessed to meet the minimum star rating required; there will be an additional
cost to re issue this report and also re stamping the amended working drawings if required.
(NCC 2016: V2, BCA) This Thermal Performance Assessment meets the 6 Star Rating required
as laid out in the NCC 2016, BCA V2, Class 1 and Class 10 Buildings
(NCC 2016: V2, BCA) It is also the responsibility of the developer, builder and/or owner builder
that the following sections of the NCC 2016, BCA Volume 2, comply; 3.12.1.1 Building fabric
thermal insulation; 3.12.1.2(c) & 3.12.1.4(b) Thermal breaks; 3.12.1.5(c) & 3.12.1.5(d) Floor edge
insulation & Part 3.12.3 Building Sealing.
(NCC 2016: V2, BCA - Victoria) In the case of a new Class 1 building, it must have either a
rainwater tank connected to all sanitary flushing systems or a solar water heater system.
See above for ceiling penetration calculations or a re-rating is required.
Plot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
ENERGY RATING SUMMARY
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-14
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT
15/06/2018
I:\SEAGATE FILES\OMAXE HOMES 2017 PROJECTS\LOT 1251\LOT 1251-AD.pln
GSPublisherVersion 286.26.100.67
A
2
6 3
7
8
11
59
4 10
2
6
6
3
5
MATERIALS & FINISHES
NO
MATERIALS/DESCRIPTION TYPES/FINISHES COLOUR
5
GARAGEDOOR
STANFORD PANEL LIFTWALNUT COLOURWITH REMOTE CTRL
1 BRICKSHOMETEAD TANAUSTRAL BRICK
7
ENTRY DOOR TIMBER LOOK
2
DRIVE WAY
3
ROOF TILES 8
GUTTERS ,FASCIER &
4
ALUMINIUMFRAME
WINDOWS9
FENCE
PORCH( L-SHAPEPILLAR )
10
EXPOSED AGGREGATE
FEATURETIMBERCLADDING
13
SPOUTING &DOWNPIPE
11
TIMBER LOOK
PORCH( BIG PILLAR)
DULUX®
BLACK
BLACK
TILE
MAGNUM( BRISTILE ROOFING)
COLOURS DISPLAYED ABOVE MAY APPEAR DIFFERENT TO ACTUAL COLOURS DUE TO PRINTER
BLACK
BLACK
6 12
PROFILE :STANDFORD- ECOGARAGE DOOR
CAPPED PRE-COATEDMETAL SHEETING PANELSFENCEWITH EXPOSED POTS(Eg. COLORBOND) IN 'BLACKRIDGECOLOUR OR COLOURED TOMATCH
FACADE CASPER WHITE QUATER
Plot Date:
MCam BuildingDesign P/L
11 Redrck Road Wollert 3750
Phone: 9- Mobile: 0425349797Web: www.mcambuildingdesign.com
PROJECT:
CLIENT NAME:
TITLE:
SCALE: SHEET No.
JOB No.
ISSUE
DRAWN
SINGLE STOREY DWELLING
JASPREET KAUR
MATERIALS & FINISHES
1251 M.C
LOT 1251 CLIFTON CIRCUITTARNEIT VIC As indicated on drawings
WD-15
CHECKED BY:
M.A.C.
8/11/16
DATE:
NORTH POINT