REVIGLASS MOSAICS T +27 21 448 0607 | F +27 21 448 4622 | [email protected] | www.pudlo.co.za | 93 Durham Avenue, Salt River, 7925, Cape Town Directors: H.G.P. Brownell N.B. De Freitas M.G. De Freitas Company Registraon No: 65/009039/07 VAT No: 4950103772 Pool - Perspective View 1 Pool - Isometric 3D - 2. Pool - Isometric 3D - 1. Level 011 60010.0 200 1000 6805 water line 1.1m deep 2 3 1 4 200 325 355 100 255 50 450 750 1250 200 250 375 375 Full height Frameless Glass wall by specialist Frameless Glass wall 50 x 50 APPIANI Mosaic (Tile specification & layout to be confirmed by client) 1100 1200 50mm Concrete coping stone 50 150 300 Dips board 50mm, Bituminous Torch-on Polyglass Evolight 2 layers, 3mm + 4mm, Screed 50mm Average [Min. 25mm to max. 75mm) 200mm Secondary Concrete structure to Enginners detail Glass upstand to specialist 400 Engineer to comment on structure upstand hegiht and width 200 100 600 300 900 100 40 80 Level 011 60010.0 G2 G1 water line 1.1m deep 550 200 250 200 50 1200 3457 Stainless Steel Balustrade Grade 316 50mm Concrete coping stone 50 x 50 APPIANI Mosaic (Tile specification & layout to be confirmed by client) 200 300 Dips board 50mm, Bituminous Torch-on Polyglass Evolight 2 layers, 3mm + 4mm, Screed 50mm Average [Min. 25mm to max. 75mm) 200mm Secondary Concrete structure to Enginners detail 100 Glass upstand to specialist 1000 200 Setting out for balustrade to specialist's requirement Setting out for balustrade to specialist's requirement EQ EQ EQ EQ EQ EQ EQ Site measure required 300 1000 1000 1175 Site measure required 1813 Site measure required 1767 13 AH(91)110 20 40 300 GF GG 50 x 50 APPIANI Mosaic (Tile specification & layout to be confirmed by client) 950 4775 300 300 250 950 50 200 250 450 800 50mm Concrete coping stone 50 100 Dips board 50mm Bituminous Torch-on Polyglass Evolight 2 layers, 3mm + 4mm Screed 50mm Average [Min. 25mm to max. 75mm) 200mm Secondary Concrete structure to Enginners detail 50 50 11 AH(91)110 200 100 300 1250 900 Level 011 60010.0 GD GF GG GK GH water line 1.1m deep 50 x 50 APPIANI Mosaic (Tile specification & layout to be confirmed by client) 375 350 250 375 50mm Concrete coping stone Stainless Steel Balustrade Grade 316 50mm Concrete coping stone 250 150 200 4817 797 253 600 3925 600 250 800 50 200 1000 50 200 1000 200 100 Dips board 50mm, Bituminous Torch-on Polyglass Evolight 2 layers, 3mm + 4mm, Screed 50mm Average [Min. 25mm to max. 75mm) 200mm Secondary Concrete structure to Enginners detail EQ EQ Setting out for balustrade to specialist's requirement EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ Setting out for balustrade to specialist's requirement EQ EQ EQ EQ Site measure required 3486 Site measure required 1825 Site measure required 300 EQ EQ Setting out for balustrade to specialist's requirement EQ EQ EQ EQ EQ EQ EQ EQ Setting out for balustrade to specialist's requirement EQ EQ EQ EQ 150 150 Site measure required 300 Site measure required 1819 Site measure required 3477 1000 1175 1175 320 40 80 G3 G3 G2 G2 G1 G1 GD GF GG GK GK GH Pool Section A Pool Section A Pool Section B Pool Section B Pool Section C Pool Section C Pool Section D Pool Section D 100 325 100 255 Swimming pool lighting Pool pump Martini Seat 3925mm wide Full Height Glass Wall Swimming pool lighting Martini Seat 950 250 600 4525 250 950 300 3925 2052 200 425 425 200 2052 600 POOL Bubbles Landscaped Stairs (With Martini Seat incorporated) 300mm Glass Infinity Edge/ Strip (All Around) Stainless Steel Balustrade Grade 316 Stainless Steel Balustrade Grade 316 200 16868 200 17068 2752 2752 All Safety equipments must be installed on face of concrete wall (Final location for equipments confirm by specialist) Pool Section E Pool Section E Swimming pool lighting 3855 5571 60 60 Pool Section F Pool Section F Pool Section G 60 60 3842 5586 50 1657 1100 400 750 250 400 1100 200 1000 200 50 1400 200 2396 250 1355 5 305 5 305 5 305 5 305 5 305 5 305 5 305 5 305 5 305 5 310 5 300 1 2 3 4 5 6 305 5 305 5 305 5 305 5 305 5 305 5 305 5 305 5 305 5 305 10640 1675 330 5 330 5 330 5 330 5 330 5 330 5 330 5 330 5 330 5 330 5 30.00° 30.00° 30.00° 1000 250 1000 250 1250 1781 935 625 935 625 620 935 625 935 1781 670 1001 1030 1030 1001 670 1000 Skimmer box 200 225 2791 220 1256 509 12 AH(91)110 Signage on precast concrete panel Signage on precast concrete panel Signage on precast concrete panel Ø75mm RWDP (Use existing sleeve) Offset fullbore side outlet Ø75mm RWDP (Use existing sleeve) Offset fullbore side outlet 410 350 500 2786 118 ACO Self Euroline (38700) - with galvanised slotted grating 118mm wide by 100mm deep 515 475 150mm high bund wall Ø56mm Drainage 150mm high Bund wall Ø56mm Drainage Inside face of concrete wall (Refer to Structural engineer's drawing) Inside face of concrete wall (Refer to Structural engineer's drawing) 200 1000 G2 G1 water line 1.1m deep 50mm Concrete coping stone Screed to fall, Dips board 100mm, Dips board 50mm, Bituminous Torch-on Polyglass Evolight 2 layers, 3mm + 4mm, Screed 50mm Average [Min. 25mm to max. 75mm) 200mm Secondary Concrete structure to Enginners detail Glass upstand to specialist 1100 1000 200 600 1200 600 2050 200 900 300 100 200 1000 200 50 L 11 60010 G1 G2 50 118 40 80 40 80 200 1000 14 AH(91)110 200 5 990 5 70 x 70 Steel angle 27 15 15 30 neoprene Reinforcement Steel Tray below Precast concrete panel 20 Reinforcement Steel Tray below Precast concrete panel 27 3 30 Neoprene 70 x 70 Steel angle 50mm Ø Brushed Stainless steel round handrail Brushed stainless steel cover plate fixing to sub-contractor detail Drill & Epoxy by specialist's requirements. 60 50 934 250 65mm high - Gotham Light font Precast concrete copping stone Level 011 60010.0 G1 ACO Self Euroline (38700) - with galvanised slotted grating 118mm wide by 100mm deep. 118 Site measure required 186 77 RWDP from grid line 500 75 Ø75mm RWDP (Use existing sleeve) refer to AH(13)110 Rev D GRIGIO CEMENTO tile Stainless steel 316 channel cover to specialist detail Glass upstand to specialist 40 160 80 1 : 25 Pool Section A 1 1 : 25 Pool Section B 2 1 : 25 Pool Section C 3 Pool Section D 1 : 50 Callout of Level 011 - Layout 5 1 : 25 Pool Section E 6 NOTE : BALUSTRADE TO BE SITE MEASURED PRIOR TO MANUFACTURER 1 : 10 Pool Section F 7 1 : 10 Pool Section G 9 1 : 5 Pool Section C - Callout 1 11 1 : 10 Copping Stone Detail 12 1 : 10 Pool Section B - Callout 1 13 1 : 10 Pool Section E - Callout 1 14 Silo pool design process

Upload: haminh

Post on 10-Feb-2019

227 views

Category:

Documents


0 download

TRANSCRIPT

REVIGLASS MOSAICS

T +27 21 448 0607 | F +27 21 448 4622 | [email protected] | www.pudlo.co.za | 93 Durham Avenue, Salt River, 7925, Cape TownDirectors: H.G.P. Brownell N.B. De Freitas M.G. De Freitas Company Registration No: 65/009039/07 VAT No: 4950103772

Notes:

Do not scale from this drawing.All dimensions are in mm unless otherwise stated.This drawing is to be read in conjunction with all relevant Architectural,Civil/Structural andService Engineer's drawings & specifications.These drawings are “best fit” to the existing historical structure, but are expected to vary fromthe actual dimensions on site. In some cases expected variances exceed normal constructiontolerance (please refer to surveys).Where there are minor discrepancies (within normal construction tolerance) the contractor isexpected to proceed with reference to local Gridlines, which are centred on structure.Discrepancies greater than 50mm are to be referred back to the professional team fordirective.At all times minimum distances and component sizes are to be maintained (eg: structuralopenings for doors or services, passage widths, etc.)

Job No. Drawing No. Revision

Copyright C

Issue Status

Project Title

Drawing Title

Scale @ A1 Date Drawn Checked Approved

Rick BrownAssociates

35-on-rose, rose streetCape Town, 8001po box, 8073,roggebaai 8012

T +27 (0)21 481 1099F +27 (0)21 481 1098E [email protected]

For Construction1.2.3.

4.

BAH(91)111330109/10/15 MK MLB

GRAIN SILO HOTEL FITOUT

Pool - 3D Views

Pool - Perspective View 1Pool - Isometric 3D - 2.

Pool - Isometric 3D - 1.

Rev. Date Description Drn. Chkd. Appd.

1 2015.09.10 Pool - For Tender MK XX

2 2015.09.23 Pool - For Tender XX

A 2015.12.01 Pool - For Construction MK XX

B 2016.01.26 Pool - Redesigned - For Construction MK XX

Level 011

60010.0

20

01

00

0

6805

water line 1.1m deep

2

3

1

4

200 325 355

100 255

50

45

07

50

12

50

20

02

50

37

53

75

Full heightFramelessGlass wall byspecialist Frameless

Glass wall50 x 50 APPIANI Mosaic (Tile specification & layout to be confirmed by client)

11

00

12

00

50mm Concrete coping stone

50

15

0

30

0

Dips board 50mm,Bituminous Torch-on Polyglass Evolight2 layers, 3mm + 4mm,Screed 50mm Average [Min. 25mm to max. 75mm)

200mm Secondary Concrete structure to Enginners detail

Glass upstand to specialist

400Engineer to commenton structure upstandhegiht and width

20

01

00

600

30

09

00

10

0

40

80

Level 011

60010.0

G2 G1

water line 1.1m deep

55

02

00

25

02

00

50

1200 3457

Stainless Steel Balustrade Grade 316

50mm Concrete coping stone

50 x 50 APPIANI Mosaic (Tile specification &layout to be confirmed by client)

20

0

30

0

Dips board 50mm,Bituminous Torch-on Polyglass Evolight2 layers, 3mm + 4mm,Screed 50mm Average [Min. 25mm to max. 75mm)

200mm Secondary Concrete structure to Enginners detail

10

0

Glass upstand to specialist

10

00

20

0

Setting out for balustradeto specialist's requirement

Setting out for balustradeto specialist's requirement

EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ

Site measure required

300

10

00

10

00

11

75

Site measure required

1813

Site measure required

1767

13

AH(91)110

20

40

30

0

GF GG

50 x 50 APPIANI Mosaic (Tile specification & layout to be confirmed by client)

9504775300300250950

50

20

02

50

45

0

80

0

50mm Concrete coping stone

50

10

0

Dips board 50mmBituminous Torch-on Polyglass Evolight2 layers, 3mm + 4mmScreed 50mm Average [Min. 25mm to max. 75mm)

200mm Secondary Concrete structure to Enginners detail

5050

11

AH(91)110

20

01

00

30

0

12

50 9

00

Level 011

60010.0

GD GF

GG

GKGH

water line 1.1m deep

50 x 50 APPIANI Mosaic (Tile specification & layout to beconfirmed by client)

37

5

35

0

25

03

75

200

50mm Concrete coping stone

Stainless Steel Balustrade Grade 316

50mm Concretecoping stone

25

015

0

20048177972536003925600250800

50

20

01

00

0

50

20

01

00

02

00

10

0

Dips board 50mm,Bituminous Torch-on Polyglass Evolight2 layers, 3mm + 4mm,Screed 50mm Average [Min. 25mm to max. 75mm)

200mm Secondary Concrete structure to Enginners detail

EQEQ

Setting out for balustradeto specialist's requirement

EQ EQ EQ EQ EQ EQ EQ EQEQ EQ

Setting out for balustradeto specialist's requirement

EQEQ EQEQ

Site measure required

3486

Site measure required

1825

Site measure required

300

EQ EQ

Setting out for balustradeto specialist's requirement

EQEQEQEQEQEQ EQEQ

Setting out for balustradeto specialist's requirement

EQ EQEQ EQ 150150

Site measure required

300

Site measure required

1819

Site measure required

3477

10

00

11

75

11

75

320

40

80

G3 G3

G2 G2

G1 G1

GD GF GG GK

GK

GH

Pool SectionA

Pool SectionA

Pool SectionB

Pool SectionB

Pool SectionC

Pool SectionC

Pool SectionD

Pool SectionD

10

0

32

5

10

0

25

5

Swimming pool lighting

Pool pump

Martini Seat

3925mm wide Full Height Glass Wall

Swimmingpool lighting

Martini Seat

950 250 600 4525 250 950

300 3925

20

52

20

04

25

42

52

00

20

52

60

0

POOL

Bubbles

Landscaped Stairs

(With Martini Seatincorporated)

300mm Glass Infinity Edge/Strip (All Around)

Stainless Steel Balustrade Grade 316

Stainless Steel Balustrade Grade 316

200 16868 200

17068

27

52

27

52

All Safety equipments must beinstalled on face of concrete wall

(Final location for equipmentsconfirm by specialist)

Pool SectionE

Pool SectionE

Swimmingpool lighting

38

55

557160

60

Pool SectionF

Pool SectionF

Pool SectionG

60

60

38

42

5586

50

16

57

11

00

40

0

750 250

40

01

10

0

20

01

00

0

20

0

50

1400 200 2396 250

1355

5

305

5

305

5

305

5

305

5

305

5

305

5

305

5

305

5

305

5

310

5

300

1 2 3 4 5 6

305

5

305

5

305

5

305

5

305

5

305

5

305

5

305

5

305

5

30510640

16

75

33

0

5

33

0

5

33

0

5

33

0

5

33

0

5

33

0

5

33

0

5

33

0

5

33

0

5

33

0

5

30.00°

30.00

° 30.0

10

00

25

0

1000 250

12

50

1781 935 625 935 625 620 935 625 935 1781

67

01

00

11

03

0

10

30

10

01

67

0

10

00

Skimmer box

200

225

2791 220 1256 509

12

AH(91)110

Signage on precastconcrete panel

Signage on precastconcrete panel

Signage on precastconcrete panel

Ø75mm RWDP(Use existing sleeve)

Offset fullbore side outlet

Ø75mm RWDP(Use existing sleeve)

Offset fullbore side outlet410

35

0 50

0

2786

11

8

ACO Self Euroline (38700) - withgalvanised slotted grating

118mm wide by 100mm deep

51

54

75

150mm high bund wall

Ø56mm Drainage150mm high Bund wall

Ø56mm Drainage

Inside face ofconcrete wall(Refer to Structuralengineer's drawing)

Inside face of concretewall(Refer to Structuralengineer's drawing)

20

01

00

0

G2 G1

L 11

60010

G1G2

water line 1.1m deep

50mm Concrete coping stone

Screed to fall,Dips board 100mm,Dips board 50mm,Bituminous Torch-on Polyglass Evolight2 layers, 3mm + 4mm,Screed 50mm Average [Min. 25mm tomax. 75mm)

200mm Secondary Concrete structure to Enginners detail

Glass upstand to specialist

11

00

1000 200 600

1200 600

2050 200

90

03

00

10

02

00

10

00

20

05

0

L 11

60010

G1G2

L 11

60010

G1G2

L 11

60010

G1G2

50

118

40

80

40

80

20

01

00

0

14

AH(91)110

200 5 990 5

70 x 70 Steel angle

27

151

5

30

neoprene

Reinforcement

Steel Tray below Precast concrete panel

20

Reinforcement

Steel Tray below Precast concrete panel

27

3 30

Neoprene

70 x 70 Steel angle

50mm Ø Brushed Stainlesssteel round handrail

Brushed stainless steel cover platefixing to sub-contractor detail

Drill & Epoxy by specialist'srequirements.

60 50

934

25

0

65mm high - Gotham Light font Precast concretecopping stone

Level 011

60010.0

G1

ACO Self Euroline (38700) -with galvanised slottedgrating 118mm wide by100mm deep.

118

Site measure required

18

67

7

RWDP from grid line

500

75Ø75mm RWDP (Use existingsleeve) refer to AH(13)110 Rev D

GRIGIO CEMENTO tileStainless steel316 channelcover tospecialist detail

Glass upstandto specialist

40 160

80

Notes:

Do not scale from this drawing.All dimensions are in mm unless otherwise stated.This drawing is to be read in conjunction with all relevant Architectural,Civil/Structural andService Engineer's drawings & specifications.These drawings are “best fit” to the existing historical structure, but are expected to vary fromthe actual dimensions on site. In some cases expected variances exceed normal constructiontolerance (please refer to surveys).Where there are minor discrepancies (within normal construction tolerance) the contractor isexpected to proceed with reference to local Gridlines, which are centred on structure.Discrepancies greater than 50mm are to be referred back to the professional team fordirective.At all times minimum distances and component sizes are to be maintained (eg: structuralopenings for doors or services, passage widths, etc.)

Job No. Drawing No. Revision

Copyright C

Issue Status

Project Title

Drawing Title

Scale @ A1 Date Drawn Checked Approved

Rick BrownAssociates

35-on-rose, rose streetCape Town, 8001po box, 8073,roggebaai 8012

T +27 (0)21 481 1099F +27 (0)21 481 1098E [email protected]

For Construction1.2.3.

4.

Asindicated

IAH(91)11033012015.07.07 MK

GRAIN SILO HOTEL FITOUT

Level 11 - Pool - Plan & Section

1 : 25

Pool Section A1

1 : 25

Pool Section B2

1 : 25

Pool Section C3

1 : 25

Pool Section D4

1 : 50

Callout of Level 011 - Layout5

1 : 25

Pool Section E6

Rev. Date Description Drn. Chkd. Appd.

A 2015.12.01 Pool - For Construction MK XX

B 2016.01.26 Pool - Redesigned - For Construction MK XX

C 2016.01.29 Pool - For Construction MK XX

D 2016.07.05 Pool - Level 11 - Omitted warm pool - For Construction MK XX

E 2016.08.23 Pool - Level 11 - Balustrade setting out - For Construction MK XX

F 2016.09.05 Pool - Level 11 - Pool Pump & precast concrete panels updated- For Construction

MK XX

G 2016.09.09 Pool - Text on Precast concrete copping stone - ForConstruction

MK XX

H 2016.09.29 Level 11 Pool - Drain channel detail & floor build up MK XX

I 2016.10.24 Pool - chamfered pool wall MK XX

NOTE : BALUSTRADE TO BE SITE MEASUREDPRIOR TO MANUFACTURER

1 : 10

Pool Section F7

1 : 10

Pool Section G9

1 : 5

Pool Section C - Callout 111

1 : 10

Copping Stone Detail12

1 : 10

Pool Section B - Callout 113

1 : 10

Pool Section E - Callout 114

Silo pool design process

REVIGLASS MOSAICS

T +27 21 448 0607 | F +27 21 448 4622 | [email protected] | www.pudlo.co.za | 93 Durham Avenue, Salt River, 7925, Cape TownDirectors: H.G.P. Brownell N.B. De Freitas M.G. De Freitas Company Registration No: 65/009039/07 VAT No: 4950103772

REVIGLASS MOSAICS

T +27 21 448 0607 | F +27 21 448 4622 | [email protected] | www.pudlo.co.za | 93 Durham Avenue, Salt River, 7925, Cape TownDirectors: H.G.P. Brownell N.B. De Freitas M.G. De Freitas Company Registration No: 65/009039/07 VAT No: 4950103772