siderise perimeter barriers & firestops for curtain walling · note: testing perimeter barrier...

6
FACADES : SIDERISE (PREVIOUSLY CALLED LAMATHERM) PERIMETER BARRIERS & FIRESTOPS TDS VERSION 1 : MAR 2017 SIDERISE ® PERIMETER BARRIERS & FIRESTOPS FOR CURTAIN WALLING Market leading solutions that meet fire and smoke stop, and sound barrier requirements in all architectural cladding panel applications. Application ‘Certifire’ approved SIDERISE CW-FS perimeter barrier and firestop systems offer an extensive range of solutions for fire stop, smoke stop and sound barrier requirements in all curtain wall and architectural cladding panel applications. Based on the experience gained through being the premier supplier to the UK and Ireland facade market, the products represent an unrivalled combination of fully qualified performance, practical installation and service benefits. The primary function of the CW system is to maintain continuity of fire resistance by sealing the void between the compartment floors or walls and the external curtain wall both horizontally and vertically. Benefits • Market leading fire resistance and smoke seal • Suitable for horizontal and vertical application • Patented product construction provides unique ability to accommodate facade movement • Fully qualified acoustic performance • Simplest and quickest to install No. 1 in Ireland for 25 years Third-party approved: ‘Certifire’ Cert. CF563 Fully compliant to Irish, UK, EU & UAE regulations Tested to BS 476 and EN 1364-4 in accordance with ETAG 026 and ASFP Guidelines Supported by market leading technical and site support services THE MAKERS OF Thermal Insulation Distributors Ltd Technical data sheet

Upload: others

Post on 18-Mar-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SIDERISE PERIMETER BARRIERS & FIRESTOPS FOR CURTAIN WALLING · Note: Testing perimeter barrier systems to EN 1364-4 is in compliance with the requirements of ETAG 026 Guideline for

FACADES : SIDERISE (PREVIOUSLY CALLED LAMATHERM) PERIMETER BARRIERS & FIRESTOPS TDS VERSION 1 : MAR 2017

SIDERISE® PERIMETER BARRIERS & FIRESTOPS FOR CURTAIN WALLINGMarket leading solutions that meet fire and smoke stop, and sound barrier requirements in all architectural cladding panel applications.

Application

‘Certifire’ approved SIDERISE CW-FS perimeter barrier and

firestop systems offer an extensive range of solutions for fire

stop, smoke stop and sound barrier requirements in all curtain

wall and architectural cladding panel applications.

Based on the experience gained through being the premier

supplier to the UK and Ireland facade market, the products

represent an unrivalled combination of fully qualified

performance, practical installation and service benefits.

The primary function of the CW system is to maintain continuity

of fire resistance by sealing the void between the compartment

floors or walls and the external curtain wall both horizontally

and vertically.

Benefits

• Market leading fire resistance and smoke seal

• Suitable for horizontal and vertical application

• Patented product construction provides unique ability to accommodate facade movement

• Fully qualified acoustic performance

• Simplest and quickest to install

• No. 1 in Ireland for 25 years

• Third-party approved: ‘Certifire’ Cert. CF563

• Fully compliant to Irish, UK, EU & UAE regulations

• Tested to BS 476 and EN 1364-4 in accordance with ETAG 026 and ASFP Guidelines

• Supported by market leading technical and site support services

THE MAKERS OF

Thermal Insulation Distributors Ltd

Technical data sheet

Page 2: SIDERISE PERIMETER BARRIERS & FIRESTOPS FOR CURTAIN WALLING · Note: Testing perimeter barrier systems to EN 1364-4 is in compliance with the requirements of ETAG 026 Guideline for

FACADES : SIDERISE (PREVIOUSLY CALLED LAMATHERM) PERIMETER BARRIERS & FIRESTOPS FOR CURTAIN WALLING

02 | T: +353 (1) 8829990 | [email protected] | www.tidl.ie

1

2

3

4

Product description

SIDERISE perimeter barriers and firestops for curtain walling use a patented method of manufacture that provides a resilient lateral compression. This facilitates ease of installation, ensures the requisite tight fit and enhances fire integrity.

Throughout the range, the materials comprise a one-piece product with a pre-compressed non-combustible stonewool core. The products also have integral aluminium foil facings to provide an overall Class ‘A1’ rating and excellent resistance to smoke.

SIDERISE CW-FS perimeter barrier and firestop systems also offer independent third party approved performance for both horizontal and vertical applications, ‘Certifire’ Certificate No CF563 refers.

The systems offer fire resistance rating options ranging from 30 mins to 5 hours and can accommodate void widths up to 1200mm. For voids in excess of 400mm contact TIDL.

In addition to providing an effective seal against the passage of fire and smoke the products will also function as an effective acoustic barrier and plenum lining.

1 SIDERISE CW-FS Firestop

2 Metal spandrel with SIDERISE Nexus Lamella Board Core

3 SIDERISE NXS Firesafe Spandrel Insulation

4 Insulation other than Class ‘A1’

5 Stonewool thermal infill insulation 60-80kg/m3

6 SIDERISE CW-FB Spandrel Protection System Fireboard

7 SIDERISE Acoustic Barrier Overlay

8 SIDERISE Acoustic Void Barrier

1

2

1

3

1

4

1

1 1

1 1

22

2

5

6

7 7

8

Page 3: SIDERISE PERIMETER BARRIERS & FIRESTOPS FOR CURTAIN WALLING · Note: Testing perimeter barrier systems to EN 1364-4 is in compliance with the requirements of ETAG 026 Guideline for

FACADES : SIDERISE (PREVIOUSLY CALLED LAMATHERM) PERIMETER BARRIERS & FIRESTOPS FOR CURTAIN WALLING

T: +353 (1) 8829990 | [email protected] | www.tidl.ie | 03

Standard systems

Sheet or strip

The materials can be either supplied as pre-cut strips to suit a

quoted void size or in sheet form for cutting on site.

Standard sheet products are supplied 1200mm x 1200mm

which may prove beneficial when the actual void size is not

known or where it varies significantly. Pre-cut strip products

are available in increments of width so as to provide a tight

compressive fit within the measured void.

Fixing brackets

Fixing brackets are required to locate the material into position.

The fixing brackets are sold separately and are provided in

1mm galvanised mild steel in flat form for folding on site.

Different size brackets are available according to the cavity

size. Please refer to Table 1 for the type and quantity required

per strip. All holes are to be drilled to suit the varying site

conditions.

TABLE 1 : Void size & fixing bracket requirements for horizontal and vertical application

Product type Barrier size Void size limitation and standard fixing bracket requirements

Thickness (mm) 50-150 mm 151-240 mm 241-400 mm 401-600 mm 601-1200 mm

CW-CB30 75 2 no B65/110 2 no B195 2 no B355 N/A N/A

CW-FS60 90 2 no B65/110 2 no B195 2 no B355 N/A N/A

CW-FS60-X 120 N/A N/A N/A 4 no B355 N/A

CW-FS60-SB 120 N/A N/A N/A N/A 3 no B900

CW-FS120 120 2 no B65/110 2 no B195 2 no B355 N/A N/A

CW-FSH20-X 175 N/A N/A N/A 4 no B355 N/A

CW-FS120SB 175 N/A N/A N/A N/A 3 no B900

CW-FSH300 175 2 no B65/110 2 no B195 2 no B355 N/A N/A

Regulations guidance - Ireland

SIDERISE perimeter barriers and firestops for curtain walling

satisfy the requirements of Technical Guidance Document B -

Fire Safety (2006).

Regulations guidance - CWCT

The ‘Standard Performance Criteria’ for fire & smoke stopping

issued by the Centre for Window and Cladding Technology

states:

‘There shall be continuity of time temperature rated fire and

smoke stopping between the curtain wall and compartment

walls and floors. Any spaces or cavities between the two shall

be effectively stopped against the spread of smoke and flame.

The fire resistance of such stopping shall be equal to that

required of the compartment floor or wall against which it

abuts.’

Continuity of fire resistance

SIDERISE CW-FS firestops are used to maintain the continuity

of the fire resistance by sealing the gap between compartment

floors (and walls) and the external curtain walling facade

or any other external cladding systems so as to maintain

compartmentation.

SIDERISE CW-FS60 (EI60) is suitable for installation in alignment

with a 1 hour rated compartment wall or floor to provide

continuity of fire resistance across the cavity.

SIDERISE CW-FS120 (EI120) is suitable for installation in

alignment with a 2 hour rated compartment wall or floor.

SIDERISE CW-FS300 (EI300) is suitable for installation in

alignment with a 4 hour compartment wall or floor.

SIDERISE CW-CB30 (EI30) is suitable as a cavity barrier to

subdivide large uninterrupted cavities.

Page 4: SIDERISE PERIMETER BARRIERS & FIRESTOPS FOR CURTAIN WALLING · Note: Testing perimeter barrier systems to EN 1364-4 is in compliance with the requirements of ETAG 026 Guideline for

FACADES : SIDERISE (PREVIOUSLY CALLED LAMATHERM) PERIMETER BARRIERS & FIRESTOPS FOR CURTAIN WALLING

04 | T: +353 (1) 8829990 | [email protected] | www.tidl.ie

Fire performance

Testing and approval

SIDERISE CW-FS perimeter barrier and firestop systems have been tested to BS 476-20 and EN 1364-4.

The systems are third-party approved via ‘Certifire’ certificate No. CF563.

TABLE 2 : SIDERISE ‘CW-FS’ approved performance to BS 476-20BS 476-20 - Floor slab to external facade assembly applications

Gap width(mm)

Product Seal width x Thickness (mm)

Performance to BS 476-20 Cover length (mm)

Fixing bracket requirement

Integrity (mins) Insulation (mins)

20 to 50

CW-CB30 Gap + 10 x 75 30 30 1200

No fixing brackets requiredCW-FS60 Gap + 10mm x 90 60 60 1200

CW-FS120 Gap + 10mm x 120 120 120 1200

CW-FS300 Gap + 10mm x 175 300 300 1125

51 to 100

CW-CB30 Gap + 15 x 75 30 30 1200

2No. standard brackets per length at 600mm centres.(Table 1 confirms standard bracket type required.)

CW-FS60 Gap + 15mm x 90 60 60 1200

CW-FS120 Gap + 15mm x 120 120 120 1200

CW-FS300 Gap + 15mm x 175 300 300 1125

101 to 400

CW-CB30 Gap + 20 x 75 30 30 1200

CW-FS60 Gap + 20mm x 90 60 60 1200

CW-FS120 Gap + 20mm x 120 120 120 1200

CW-FS300 Gap + 20mm x 175 300 300 1125

401 to 600CW-FS60-X Gap + 25mm x 120 60 60 1200 4No. standard brackets per

length at 300 mm centresCW-FS120-X Gap + 25mm x 175 120 120 1125

601 to 1200CW-FS60-SB Gap + 40mm x 120 60 60 1200 3No. structural brackets per

length at 400 mm centresCW-FS120-SB Gap + 40mm x 175 120 120 1125

TABLE 3 : SIDERISE ‘CW-FS’ approved performance to BS EN 1364-4BS EN 1364-4 - Floor slab to external facade assembly applications

Gap width (mm) Product Seal width x Thickness (mm)

Performance to BS EN 1364-4 Cover length (mm)

Fixing bracket requirement

Integrity (mins) Insulation (mins)

20 to 50CW-FS120 Gap + 10% x 120 120 120 1200

No fixing brackets requiredCW-FS180 Gap + 10% x 150 210 210 1200

51 to 100CW-FS120 Gap + 10% x 120 120 120 1200 2No. B65/110 brackets per

length at 600mm centresCW-FS180 Gap + 10% x 150 210 210 1200

151 to 250CW-FS120 Gap + 10% x 120 120 120 1200 2No. B195 brackets per

length at 600mm centresCW-FS180 Gap + 10% x 150 210 210 1200

Note: Testing perimeter barrier systems to EN 1364-4 is in compliance with the requirements of ETAG 026 Guideline for European Technical Approval of Firestopping and Fire Sealing Products Part 3 Linear Joint and Gap Seals - Annex D.

System selection

The correct system is simply selected by matching the fire resistance requirements to the CW-FS type and void size.

Tables 2 & 3 summarise the nominal fire rating for horizontal and vertical applications together with confirmation of void size limitation and standard dimensions.

Page 5: SIDERISE PERIMETER BARRIERS & FIRESTOPS FOR CURTAIN WALLING · Note: Testing perimeter barrier systems to EN 1364-4 is in compliance with the requirements of ETAG 026 Guideline for

FACADES : SIDERISE (PREVIOUSLY CALLED LAMATHERM) PERIMETER BARRIERS & FIRESTOPS FOR CURTAIN WALLING

T: +353 (1) 8829990 | [email protected] | www.tidl.ie | 05

Movement

Curtain walling and external facade deflection

The maximum movement that a fire resistive joint system can

accommodate is critically important for perimeter firestop

barriers. The system used needs to have a degree of ‘dynamic’

movement capability in order to accommodate serviceability

movement.

Main modes of movement effecting perimeter barrier

performance are vertical deflection due to dead and live loads

and negative and positive (in/out) movement, typically due to

wind pressure. These are covered by EN 13116.

For curtain walling applications it is imperative that the installed perimter barrier system is able to function effectively with regard to all design movement serviceability limits.

Design considerations

Typically, a project may stipulate that the curtain walling system may have the following allowable deflection limits: -

“Under the declared wind loads the maximum frontal deflection of the curtain walling’s framing members shall not exceed L/200 or 15mm, whichever is the less, when measured between the points of support or anchorage to the building’s structure in compliance with EN 13116” - extract from EN 13830.

Important factors for consideration: -

• Review the position of fire stop and distance from fixing bracket connection

• Ensure the structural engineer specifies the facade deflection

• Consider both inward and outward deflection requirements for the system

• Review the curtain wall expansion and any floor slab/building movement

• Review transom/mullion deflection

Upon confirmation of the above factors, it may be necessary to include an ‘additional’ compression allowance when installing the firestop.

Installation of the correct material size is important to ensure that integrity is maintained.

Note - Performance is always a function of both Specification

and Installation. TIDL are pleased to assist with advice on a

project basis.

SIDERISE CW-FS - a unique method of manufacture

SIDERISE has developed a patented method of manufacture which affords the range of CW-FS perimeter barriers and firestops a unique flexiblity and robustness to meet all the performance criteria required of modern curtain walling. Importantly, the systems can accommodate typical facade deflection due to their unique construction, which accepts the cyclical negative and positive wind and live loads imposed on the facade.

Performance

SIDERISE CW-FS systems are made to a consistent specification

with quantified movement properties.

Standard lateral movement is +/- 10% for cavities up to 300mm.

Based on the design considerations, where the anticipated

serviceability movement exceeds +/-10%, the project specific

Method Statement needs to reflect a specific compression

requirement to allow the permissible movement of up to +/-

20mm, i.e. 40mm amplitude.

Movement capability of the system in the event of a fire

SIDERISE CW-FS products have been tested to BS EN 1364-4.

This test isolates the junction between the compartment floor

and the spandrel zone, and specifically models and measures

the movements of curtain wall and the floor during a fully

developed / flashed-over fire. It is a three-dimensional test with

real, live, dynamic movement induced by extreme heat, with

a closed closed furnace pressurised to 20 PA. The test provides

information on how the seal performs in a real-world assembly

when subject to a real-world fire scenario, at high pressure,

where the forces impacting on the barrier are significant,

unpredictable and changing – dynamic in the true sense.

As an example, SIDERISE CW-FS120, when tested to EN1364-4,

and subjected to 20 PA and EN1363 time temperature curve,

the joint system accommodated 20% shear on 120mm thick

product. No integrity failure.

The movement property of the SIDERISE CW-FS systems whilst

maintaining Integrity is considerable and is considered to be a

key benefit.

Page 6: SIDERISE PERIMETER BARRIERS & FIRESTOPS FOR CURTAIN WALLING · Note: Testing perimeter barrier systems to EN 1364-4 is in compliance with the requirements of ETAG 026 Guideline for

FACADES : SIDERISE (PREVIOUSLY CALLED LAMATHERM) PERIMETER BARRIERS & FIRESTOPS TDS VERSION 1 : MAR 2017

Further information

Products available

The following products are available: -

• SIDERISE CW-FS perimeter barriers and firestops for curtain

walling - in either sheet or pre-cut strip options

• Foil tape: type T303

• Fixing brackets: types B65/110, B195, B355 and B900

• Sealant: TIDL fire and acoustic gap sealant

Further information

The following information is available: -

• Installation guidance

• Site support services including training and inspection

• Acoustics performance data and advice

• Protected spandrel system

TIDL technical & sales support

Denis McGill

Fire Stopping/Acoustic Sales Manager

T: +353 (1) 8829990

M: +353 863 692992

E: [email protected]

Kevin Walsh

Internal Sales Coordinator

T: +353 (1) 8829990

E: [email protected]

SIDERISE GROUPForge Industrial Estate,Maesteg, UK, CF34 0AYT: +44 (0)1656 730833F: +44 (0)1656 812509E: [email protected]: www.siderise.com

THERMAL INSULATION DISTRIBUTORS LIMITED. Units 1-4 Keypoint, Rosemount Business ParkBallycoolin, D11 XP70, Dublin 11, IrelandT: +353 (1) 8829990 F: +353 (1) 8829992 E: [email protected] W: www.tidl.ie

Technical specification

Form supplied Sheet: 1200mm x 1200mm x thickness; Pre-cut strips 1200mm x (cavity + compression as ‘Certifire’ CF563 Cert) x thickness (See Table 1.)

Colour Silver with SIDERISE logo and coloured identification tape, centrally located on the product, on one surface

Finish Aluminium foil

Density Nominal 75Kg/m3

Thermal conductivity λ20 = 0.039w/mK

Cavities 50mm to 1200mmFor voids over 600mm please contact [email protected]

Fire resistance 60 to 300 minutes.Please refer to ‘Certifire’ Cert CF563 for verification and full details.

Reaction to fire Class ‘A1’ in accordance with EN 13501-1