siamesa recto y siamesa giacomini

Upload: eselcosac

Post on 31-Oct-2015

130 views

Category:

Documents


1 download

TRANSCRIPT

  • 12

    SPECIFY THREAD

    CERTIFICATIONS

    CERTIFICATIONS

    SPECIFY THREAD

    Straight Single Clapper Two-Way Inlets

    90 Single Clapper Two-Way Inlets

    A95

    A96

    Exposed auxiliary inlet connection with 500 G.P.M. inlet capacity to supplement fire protection water supply.Exposed design provides an economical method of satisfying Fire Dept. inlet requirements.

    Standard equipment:Cast brass two-way inlet body with single swing clapper and pin or rocker lug hose thread swivel; straight NPT outlet connection.

    Branding: AUTO SPKR

    Exposed auxiliary inlet connection with 500 G.P.M. inlet capacity to supplement fire protection water supply. Exposed design provides an economical method of satisfying Fire Dept. inlet requirements.

    Standard equipment:Cast brass two-way inlet body with single swing clapper and pin or rocker lug hose thread swivel; angle NPT outlet connection.

    Branding: AUTO SPKR

    CE x 1191 LISTED 166Y

    CE x 1191 LISTED 166Y

    5-33/64A

    4 x 2-1/2

    B 8-5/64

    2-1/2

    a

    4

    b

    8-5/64A

    4 x 2-1/2

    B 6-11/16

    C 4-29/32

    2-1/2

    a

    4

    b

    A

    B

    C

    b b

    a

    a

    b b

    A

    B

  • (Technical communication n A-007)

    A95 Straight single clapper two-way inlets

    Standard equipment

    Cast brass two-way inlet body with single swing clapper and pin or rocher lug hose thread swivel; straight NPT outlet connection.

    Standard equipmentProductThreadConstructionDimensionsFunction

    Product

    An exposed auxiliary inlet connection with 500 gpm inlet capacity to supplement fire protection water supply. Exposed design provides an economical method of satisfying Fire Dept. inlet requirements.

    a b 4" 2 1/2"

    Branding AUTO SPKR

    Optional finishes: RP - Red painted

    Standard equipmentProductThreadConstructionDimensionsFunction

    Thread

    A95Y000 A95Y001 A95Y003 A95Y004 A95Y005 A95Y006 A95Y007

    4" X 2 1/2" without swivel 4" X 2 1/2" NST PL 4" X 2 1/2" CSA RL 4" X 2 1/2" BCT RL 4" X 2 1/2" QST RL 4" X 2 1/2" WCT RL 4" X 2 1/2" NSST RL

    ---- Abbreviation List ---- Standard equipmentProductThreadConstructionDimensionsFunction

    24/08/2006file://E:\Notetecniche\NoteTecnicheENG\A95.htm

  • A95Y008 A95Y009

    4" X 2 1/2" NWFLD RL 4" X 2 1/2" NPSH RL

    Available also with red painted body

    A95Y053 A95Y054 A95Y055 A95Y056 A95Y057 A95Y058

    4" X 2 1/2" CSA RL Red 4" X 2 1/2" BCT RL Red 4" X 2 1/2" QST RL Red 4" X 2 1/2" WCT RL Red 4" X 2 1/2" NSST RL Red 4" X 2 1/2" NWFLD RL Red

    Construction Cast brass two-way inlet body with single clapper and pin or rocker lug hose thread swivel.

    Standard equipmentProductThreadConstructionDimensionsFunction

    Dimensions

    4" x 2 1/2" A 5 33/64" B 8 5/64"

    Standard equipmentProductThreadConstructionDimensionsFunction

    Function Used as an auxiliary inlet connection providing 500 gpm minimum to supplement the fire protection water supply (NFPA 14 Section 5.9 and NFPA 13 Section 2.7). Swing clapper provides unobstructed waterway. Exposed design is an economical method of satisfying Fire Dept. inlet requirements.

    Standard equipmentProductThreadConstructionDimensionsFunction

    24/08/2006file://E:\Notetecniche\NoteTecnicheENG\A95.htm

  • (Technical communication n A-008)

    A96 90 single clapper two way inlets

    Standard equipment

    Cast brass two-way inlet body with single swing clapper and pin or rocher lug hose thread swivel; angle NPT outlet connection.

    Standard equipmentProductThreadConstructionDimensionsFunction

    Product

    An exposed auxiliary inlet connection with 500 G.P.M. inlet capacity to supplement fire protection water supply. Exposed design provides an economical method of satisfying Fire Dept. inlet requirement

    a b 4" 2 1/2"

    Branding AUTO SPKR

    Optional finishes: RP - Red painted

    ProductThreadConstructionDimensionsFunction

    Thread

    A96Y000 A96Y001 A96Y003 A96Y004 A96Y005 A96Y006 A96Y007 A96Y008

    SIAM 4" X 2 1/2" without swivel SIAM .4" X 2 1/2" NST PL SIAM. 4" X 2 1/2" CSA RL SIAM 4" X 2 1/2" BCT RL SIAM. 4" X 2 1/2" QST RL SIAM. 4" X 2 1/2" WCT RL SIAM. 4" X 2 1/2" NSST RL SIAM .4" X 2 1/2" NWFLD RL

    Available also with red painted body

    A96Y053 SIAM. 4" X 2 1/2" CSA RL Red

    ---- Abbreviation List ---- ProductThreadConstructionDimensionsFunction

    24/08/2006file://E:\Notetecniche\NoteTecnicheENG\A96.htm

  • A96Y054 A96Y055 A96Y056 A96Y057 A96Y058

    SIAM. 4" X 2 1/2" BCT RL Red SIAM. 4" X 2 1/2" QST RL Red SIAM. 4" X 2 1/2" WCT RL Red SIAM 4" X 2 1/2" NSST RL Red SIAM. 4" X 2 1/2" NWFD RL Red

    Construction Cast brass two-way inlet body with single clapper and pin or rocker lug hose thread swivel.

    ProductThreadConstructionDimensionsFunction

    Dimensions

    4" x 2 1/2" A 8 5/64" B 6 11/16" C 4 29/32"

    ProductThreadConstructionDimensionsFunction

    Function Used as an auxiliary inlet connection providing 500 gpm minimum to supplement the fire protection water supply (NFPA 14 Section 5.9 and NFPA 13 Section 2.7). Swing clapper provides unobstructed waterway. Exposed design is an economical method of satisfying Fire Dept. inlet requirements.

    ProductThreadConstructionDimensionsFunction

    24/08/2006file://E:\Notetecniche\NoteTecnicheENG\A96.htm

  • VSQV.EX3314Fire Department Connections

    Page Bottom

    Fire Department Connections

    See General Information for Fire Department Connections

    GIACOMINI SPA EX3314VIA PER ALZO 3928017 S MAURIZIO D'OPAGLIO, NOVARA ITALY

    Exposed type.

    Model PatternSize(in.)

    Rated Pressure(psig)

    A95 Straightway 4 by 2-1/2 by 2-1/2 300

    A96 90 Degree 4 by 2-1/2 by 2-1/2 300

    A105 Straightway 4 by 2-1/2 by 2-1/2 175

    A106 90 Degree 4 by 2-1/2 by 2-1/2 175

    A105 Straightway 4 by 3 by 3, 6 by 3 by 3 300

    A106 90 Degree 4 by 3 by 3, 6 by 3 by 3 300

    A90C Straightway 3 by 2-1/2 300

    A91C Straightway 3 by 2-1/2 300

    Flush type.

    Model PatternSize(in.)

    Rated Pressure(psig)

    A101 Straightway 4 by 2-1/2 by 2-1/2, 4 by 3 by 3, 6 by 2-1/2 by 2-1/2 175

    A102 90 Degree 4 by 2-1/2 by 2-1/2, 4 by 3 by 3 175

    A190T Single inlet 1-1/2 175

    Trademark and/or Tradename:

    Last Updated on 2010-05-28

    Questions? Print this page Notice of Disclaimer Page Top

    Copyright 2010 Underwriters Laboratories Inc.

    The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufacturedunder UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-UpService. Always look for the Mark on the product.

    UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The GuideInformation, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data(or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." mustappear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 2010 Underwriters Laboratories Inc."

    VSQV.EX3314 - Fire Department Connections http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpag...

    1 de 2 19/07/2010 02:28 p.m.

  • VSQV.EX3314 - Fire Department Connections http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpag...

    2 de 2 19/07/2010 02:28 p.m.

  • Fire Service Connections A fire service pumper connection, located outside buildings, permits the fire service to pump water into a sprinkler system from anearby public hydrant or reservoir. Water supplied at high pressure will aid automatic sprinklers to control a fire. The connection mayalso be used to supply building standpipes. FM Approved connections are made of bronze and consist of two inlet couplings threaded for standard fire hose and siamesed into anoutlet pipe connection. A check valve is provided in each inlet so that either connection may be used separately. The connections areavailable in straight, 45 or 90 patterns. Unless otherwise noted in the listing, these connections have 175 psi (1205 kPa) ratedworking pressure.

    Fig. Nos. A95, A96, A105, A106

    Fig.No.

    ComponentDescription

    NominalSize,

    Inlets xOutlet,

    in.

    A95 StraightwaySiamese

    2 12 x 212 x 4

    A96 90 Siamese 2 12 x 212 x 4

    A105 StraightwaySiamese

    2 12 x 212 x 4

    A106 90 Siamese 2 12 x 212 x 4

    Company Name: Giacomini SpACompany Address: Strada Per Alzo 39, 28017 S Maurizio d'Opaglio, ItalyCompany Website: http://www.giacomini.com

    Listing Country: ItalyCertification Type: FM Approved