shower-ware 700 series - acorn eng · tel: (800)488-8999 • (626) 336-4561 • fax: ... or -sc...
TRANSCRIPT
Acorn Engineering Co. • 15125 Proctor Ave. • P.O. Box 3527 • City of Industry, CA 91744-0527 U.S.A.
Tel: (800)488-8999 • (626) 336-4561 • Fax: (626) 961-2200 • www.acorneng.com • E-mail: [email protected]
Page 1
Fixture May Show Some Available Options
Capital Column Showers Two to Six Station Models
Capital Column Showers Two to Six Station Models
Column Shower is heavy gage, type 304 stainless steel with satin finish. Column showers are completely pre-piped to the valve, shower head, and optional soap system. All Column Showers are hydrostatically tested to 150 PSI.
Showerheads are solid brass, triple chrome-plated and include a 1.6 GPM flow restrictor. The Acorn Logan Wizard Showerhead design provides self-cleaning with every use, and has an adjustable spray pattern from a coarse stream to a fine mist.
Bronze Manifolds and valve bodies are used for long life and maximum corrosion protection in all Column Showers. Fittings for connecting to 3/4” NCT inlets are furnished by others.
Control Valve type is indicated by selected Capital model number. All valves have replaceable cartridges which contain all wearing parts and are serviced from the face of the shower for easy maintenance. Valve is tamper-resistant with an easy to close mechanism and low leverage handle to protect the operating parts from excessive torque. Note: Air-Control and Electronic Valves (-MVC, -EVS) must be located remotely or positioned above unit within -VC Valve Cover (Bottom Supply) or -SC Supply Cover (Top Supply). Refer to appropriate factory installation detail for additional information.
Circular Soap Tray is furnished standard, except when Diana compartments are used. Liquid soap systems are optional.
Drain Base is cast iron with a rust preventative coating, and provides a secure mounting for the column. If a separate or area drain is to be utilized, an Acorn drain base may be installed to provide column anchoring only or column may be mounted directly to floor. Optional -LD Less Drain Slots is recommended on these types of installations.
Fasteners. Acorn furnishes all exposed tamper-resistant fasteners necessary to complete the on-site shower assembly installation; however, supply cover ceiling fasteners are not furnished.
GUIDE SPECIFICATION
Provide and install Acorn Capital Column Showers (specify model number and options). Column shall be 16 gage, type 304 stainless steel with satin finish. Column shall be factory pre-piped and hydrostatically tested to 150 PSI. Drain base shall be heavy cast iron with a rust preventative coating. Showerhead discharge height shall be (specify). Shower shall be provided with the following optional equipment: (example -GG Unit Shutoff Valve). Installation shall be made in accordance with manufacturer’s recommendations and details.
S.700
® Shower-Ware 700 Series
765-B11-LD
Please visit www.acorneng.com for most current specifications.
Revised: 05/2/18
5-STATION 6-STATION
4"(102) 13" TYP.
(330)
718"
(181)
SHOWERHEAD
DISCHARGEHEIGHT
A.F.F.
2-STATION 3-STATION 4-STATION
21
3
4
5
6
7
8
MODEL# 700-T21 SERIES
Optional B11 Drain Base with
Access Cover
Tamper Resistant Fasteners
#1 Station Showerhead
NOTES:
Optional -SC Supply Cover
Circular Soap Tray (Not Available
Control Valve
Sprayhead Lid
MODEL# 700-B11 SERIES
Dome Grate shown
1
DRAINSLOTS
with Diana Privacy Compartments)
4.
3.
2.
1.
7.
5.
6.
8.
MODEL# 700-LD SERIES
9
Optional -LD Less Drain Slots 9.
#1 STATIONTYPICAL
®Shower-Ware : 700 Capital Column Showers Two to Six Station Models
Acorn Engineering Co. • 15125 Proctor Ave. • P.O. Box 3527 • City of Industry, CA 91744-0527 U.S.A.
Tel: (800)488-8999 • (626) 336-4561 • Fax: (626) 961-2200 • www.acorneng.com • E-mail: [email protected]
Page 2
Selection Summary
Model No. & Option___________________________
Quantity____________________________________
Approved for Manufacturing
Company__________________Title______________
Signature_________________ Date______________
Important: Installation instructions and current rough-in are furnished with each fixture. Do not rough in without certified dimensions.Dimensions are subject to manufacturer’s tolerance of plus or minus 1/4" and change without notice. Acorn assumes no responsibility for use of void or superseded data. © Copyright 2006 Acorn Engineering Company
S.700 Revised: 05/02/18
Acorn Engineering Co. • 15125 Proctor Ave. • P.O. Box 3527 • City of Industry, CA 91744-0527 U.S.A.
Tel: (800)488-8999 • (626) 336-4561 • Fax: (626) 961-2200 • www.acorneng.com • E-mail: [email protected]
Page 3
Selection Summary
Model No. & Option___________________________
Quantity____________________________________
Approved for Manufacturing
Company__________________Title______________
Signature_________________ Date______________
Important: Installation instructions and current rough-in are furnished with each fixture. Do not rough in without certified dimensions.Dimensions are subject to manufacturer’s tolerance of plus or minus 1/4" and change without notice. Acorn assumes no responsibility for use of void or superseded data. © Copyright 2006 Acorn Engineering Company
S.700
®Shower-Ware : 700 Capital Column Showers Two to Six Station Models
Showerhead Discharge Height (Not Part of Model Number)o 6'-0" o 5'-6" o 5'-0" o Other (Specify) ___________
MODEL NUMBER AND OPTIONS SELECTION
SERIES (Must Specify)7 Capital
NUMBER OF STATIONS (Must Specify)o 2 o 3 o 4 o 5 o 6
VALVE (Must Specify)-0 Electronic Valves, Single-Temp Metering
(Requires -SC Supply Cover or -VC Valve Cover) -1 Flo-Cloz, H & C-2 Safti-Trol, H & C Pressure Balancing-5 Flo-Cloz, Single Temperature-6 Air-Control, Single Temperature Metering
(Requires -SC Supply Cover or -VC Valve Cover)-7 Meter-Matic, Single Temperature Metering-9 Without Valves (Valves by Others)
ELECTRONIC VALVE SELECTION Master-Trol (Electronic)
-EVS1 Single Temp o -EVSP1 Single Temp, Piezo Button
Master-Trol PLUS (Electronic)
-MTP1 Single Temp o -MTPP1 Single Temp, Piezo Button
Time-Trol (Electronic)
-MVC1 Single Temp
Programmable (Electronic) w/9VDC Plug-In Transformer -PPZ1 Single Temp Programmable Piezo Button
SUPPLY BUILD (Must Specify) Supply
Top Supply
OPTIONAL DRAIN TYPE For Bottom Supply:
B11 B15 B21 B25
For Top Supply:T11 T15 T21 T25
o
o
o o o o
o o
o
o
o
o
o Bottomo
o o o o
o o o o
®
®
®
3
Please visit for most current specifications.www.acorneng.com
Revised: 05/2/18
VALVE OPTIONS o -CI Cycle Interrupt for Time-Trol Valves
-GG Unit Shutoff Valve -LVR Lever Handle (-5 & -8 Valves)
o -TF Transformer, 120VAC to 24VAC (-MVC option only)
SHOWERHEAD OPTIONS o -F Flow Control
-FX Hand Shower With 60" Stn. Stl. Hose
(In Lieu of Conventional Showerhead)o -QD Quick-Disconnecto -PSO -QD w/ Positive Shut-OffStation # o 1 o 2 o 3 o 4 o 5 o 6
o -H Hand Volume Control o -K Allen Key Volume Control o -MSH Multi-Stream Showerhead o -P Penal Showerhead o -Y Universal Ball Jointo -YY Lockable Universal Ball Jointo -Z Up-Down Ball Jointo -ZZ Lockable Up-Down Ball Joint
DRAIN OPTIONS-BDA Bradley Drain Adapter -FO 4" No-Hub Waste Outlet (B11, T11 drains) -IC 3" Inside Caulk Waste -LD Less Drain Slots -TC Thermostatic Controller
(Available With Vent Off Drain Style Only)
PRODUCT OPTIONS-BS Built-in Liquid Soap System-CA Ceiling Anchor Plate for Supply Cover-CF Adjustable Column Flange -DS Diana Circular Privacy (See Diana Privacy Tab)-EG Enviro-Glaze Color, Specify ______________ -FS Foot Shower at One Station, Specify
Station # o 1 o 2 o 3 o 4 o 5 o 6 -LCD Less Circular Soap Dish
o -MS Modular Privacy Compartments (See Diana Privacy Tab)
-SC Supply Cover, Ceiling Height __________ (Air-Control/Electronic Valves - Bottom Supply)
-VC Valve Cover to Conceal Optional Air Control /Electronic Valve &/or Thermostatic Controllerwith Bottom Supply (108” Min Ceiling Height)
o o
o
o o o o o
o o o o o o
o
o
o
o 2.0 GPM (After July 1, 2018 This Option Will BeNot Longer Available in California)
Get Started www.mgispecbuilder.comConfigure products and create specs with ease.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov