ShoreTel Virtual Mobility Router Deployment Guide

Mobility 9

September 2, 2016

Page 2: ShoreTel Virtual Mobility Router Deployment Guide Mobility 9

Legal Notices

Document and Software CopyrightsCopyright © 1998-2016 by ShoreTel Inc., Sunnyvale, California, USA. All rights reserved. Printed in the United States of America. Contents of this publication may not be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without prior written authorization of ShoreTel, Inc. ShoreTel, Inc. reserves the right to make changes without notice to the specifications and materials contained herein and shall not be responsible for any damage (including consequential) caused by reliance on the materials presented, including, but not limited to typographical, arithmetic or listing errors.

Trademarks and PatentsShoreTel, ShoreTel (and logo), ControlPoint, Brilliantly Simple, Brilliantly Simple Communication, ShoreCare, ShoreGear, ShorePhone, and ShoreWare are registered trademarks of ShoreTel, Inc. in the United States and/or other countries. The ShoreTel logo is a trademark of ShoreTel, Inc. in the United States and/or other countries.All other copyrights and trademarks herein are the property of their respective owners.The ShoreTel Mobility solution is covered by patents as listed at http://www.shoretel.com/about/patents.html.

Version InformationShoreTel Virtual Mobility Router Deployment Guide Date: September 2, 2016

Company InformationShoreTel, Inc.960 Stewart DriveSunnyvale, California 94085 USA+1.408.331.3300+1.408.331.3333 (fax)www.shoretel.com

ShoreTel Virtual Mobility Router ii

Page 3: ShoreTel Virtual Mobility Router Deployment Guide Mobility 9

ShoreTel Virtual Mobility Router Deployment Guide 1

Chapter 1 ShoreTel Virtual Mobility Router Overview . . . . . . . . . . . . . . . . . . . . . . . . . .1

Chapter 2 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3What You Need . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Installing the Virtual Mobility Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Changing MAC Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Adding a License . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Reviewing License Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Deploying the Virtual Mobility Router in High Availability Mode . . . . . . . . . . . . . . . . . . . . . . . . 10Upgrading the Virtual Mobility Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Table of Contents

Page 4: ShoreTel Virtual Mobility Router Deployment Guide Mobility 9

CHAPTER

1

1. ShoreTel Virtual Mobility

Router Overview

The ShoreTel Virtual Mobility Router solution is designed to extend the ShoreTel Mobility Router and its Unified Communications functionality to the Cloud, providing greater flexibility and scalability. The Virtual Mobility Router is a VMware virtual appliance residing on VMware-based platforms, delivered as an OVA/OVF (Open Virtual Appliance/Open Virtual Format) file.

The ShoreTel virtual Mobility Router for Mobility 9 is supported in the ShoreTel Connect platform. Figure 1 on page 2 shows the deployment topology for the Virtual Mobility Router.

ShoreTel Virtual Mobility Router Deployment Guide 1

Page 5: ShoreTel Virtual Mobility Router Deployment Guide Mobility 9

ShoreTel Virtual Mobility Router Overview1

Figure 1: ShoreTel Virtual Mobility Router Deployment Topology

This deployment guide contains the following sections:

What You Need on page 3 Installing the Virtual Mobility Router on page 4 Changing MAC Address on page 6 Adding a License on page 8 Deploying the Virtual Mobility Router in High Availability Mode on page 10 Upgrading the Virtual Mobility Router on page 10

Deployment Guide ShoreTel Virtual Mobility Router 2

Page 6: ShoreTel Virtual Mobility Router Deployment Guide Mobility 9

CHAPTER

2

2. Configuration

This chapter describes the process for installing the ShoreTel Virtual Mobility Router. The Virtual Mobility Router is delivered as a separate .ova/ovf file and is part of the system installation in a VMware environment.

Deploy the Virtual Mobility Router by using a VMware vSphere client on a vCenter server.

What You NeedShoreTel Virtual Mobility Router specifications:

4 Virtual CPUs, minimum 4GB RAM 100GB disk space 2 network interfaces

NoteThis configuration supports VMWare vSphere ESXi 5.1, ESXi 5.5, and ESXi 6.0 only.

ShoreTel Virtual Mobility Router Deployment Guide 3

Page 7: ShoreTel Virtual Mobility Router Deployment Guide Mobility 9

Configuration Installing the Virtual Mobility Router2

Before starting the wizard, have the following information available:

Mobility Router hostname If not using DHCP:

Mobility Router IP address Subnet mask Default gateway for Mobility Router IP address of primary DNS server Domain name for the Mobility Router

Password for administrative access to Mobility Router

Installing the Virtual Mobility RouterThe following procedure installs the ShoreTel Virtual Mobility Router in a vSphere client:

1. Run vSphere client and log on to vCenter server.

2. Click File > Deploy OVA/OVF Template…

3. Browse to the location of the virtual SMR's .ova or .ovf template file, and click Next.

4. Review the OVF template details.

5. Type a name for the deployed template.

6. Select the destination storage for virtual SMR files. (Make sure the datastore you select has at least 100 GB of free space.) Click Next.

7. Select “Thick Provisioned Lazy Zeroed” as the disk format to store the virtual SMR disk, and then click Next.

8. Map the networks used in the OVA/OVF template to networks in customer inventory, and then click Next.

NoteThe MAC address and License pair is provided by ShoreTel. If you did not receive this information, contact http://support.shoretel.com for more information.

Notes for VMWare Support VMware Tools 9.4.0 is included as part of the ShoreTel Virtual Mobility Router image. High Availability and VMWare vMotion are supported. Fault Tolerance is not supported. VMware does not support this feature across multiple CPUs. Snapshots are not supported. Snapshots can consume significant CPU and memory resources,

impacting system operation.

Deployment Guide ShoreTel Virtual Mobility Router 4

Page 8: ShoreTel Virtual Mobility Router Deployment Guide Mobility 9

Configuration Installing the Virtual Mobility Router2

.

9. Review the settings.

10. Select Power on after deployment, and then click Finish to deploy the virtual machine.

11. The vSphere client will load the virtual SMR and install it in the vCenter server.

After the installation is complete, the virtual SMR appears in a powered-on state in the vSphere client.

12. On the newly created vSMR, select Console.

13. At the login prompt, type admin and press Enter.

14. When prompted to accept the End User License Agreement, enter YES to accept.

The initial configuration wizard starts.

15. Enter Y to use the wizard.

16. Enter the DNS hostname of the Mobility Router. The hostname can be in short-name format or a fully qualified domain name.

17. At the ‘Use DHCP on ETH0’ interface prompt, do one of the following:

To use DHCP, enter Y, and go to Step 23. Enter N if DHCP is not desired. Continue to step 18.

18. Enter the Mobility Router's primary IP address.

19. Enter the subnet mask in the format of a 32-bit mask or classless interdomain routing (CIDR) notation.

20. Enter the IP address of the default gateway for the Mobility Router.

21. Enter the IP address of the primary domain name server (DNS).

22. Enter the domain name in the format domain-name.com. This suffix is appended to all DNS queries.

NoteSelect the destination that corresponds with your internal network, typically ETH0 on the ShoreTel Mobility Router. Refer to the ShoreTel Mobility Router Hardware Installation Guide for information on ETH0 and ETH1 and the differences between the two interfaces.

NoteShoreTel recommends using a static IP address so that the IP address of the Mobility Router does not change. If using DHCP, make sure to reserve an IP address for the Mobility Router.

NoteA secondary IP address can be configured using the Administration Portal.

Deployment Guide ShoreTel Virtual Mobility Router 5

Page 9: ShoreTel Virtual Mobility Router Deployment Guide Mobility 9

Configuration Changing MAC Address2

23. Assign a password to the default Admin account for future access to the Mobility Router Administration Portal.

24. Confirm the password for the default Admin account.

25. After completing the initial configuration wizard, a summary list of the information appears.

26. To make any changes, enter the number associated with the line to be changed. Verify the information and press Enter to save the configuration.

27. At the prompt, enter enable.

28. Enter reload to restart the Mobility Router. Wait for the login prompt in the terminal emulation software window, which indicates that the Mobility Router has finished restarting.

29. Verify a network connection to the Mobility Router can be established by accessing the Administration Portal. To access the Administration Portal, enter the Mobility Router hostname or IP address in a Web browser:

http://hostname.domain.com/admhttp://a.b.c.d/adm

30. After verifying access to the Administration Portal, disconnect the serial cable. (Console access is no longer required.)

The ShoreTel Virtual Mobility Router is now ready to be configured using the Administration Portal. For more information, see the ShoreTel Mobility Router Administration Guide.

Changing MAC AddressThe following procedure changes the MAC address of the ShoreTel Virtual Mobility Router on vSphere.

1. Establish a connection using vSphere.

2. Power off all vSMR instances.

3. Right click on the vSMR and select Edit Settings…

4. On the Setting page, select Network adapter 1. (This is the ETH0 interface that must be changed for the vSMR.)

5. Select Manual and enter the MAC address. (To locate these fields, refer to the example in Figure 2 on page 7, which is shown for sample purposes only.)

NoteDo not leave the password field blank.

Deployment Guide ShoreTel Virtual Mobility Router 6

Page 10: ShoreTel Virtual Mobility Router Deployment Guide Mobility 9

Configuration Changing MAC Address2

Figure 2: Sample Virtual Mobility Router Settings

6. Click OK.

7. Repeat these steps for each vSMR instance.

8. Power on the vSMRs when complete.

Deployment Guide ShoreTel Virtual Mobility Router 7

Page 11: ShoreTel Virtual Mobility Router Deployment Guide Mobility 9

Configuration Adding a License2

Adding a LicenseAn end-user license key is shipped with the Virtual Mobility Router. Enter this license key before enabling end users on the Mobility Router.

If you did not receive this license key, send a message to [email protected].

Figure 3: Licensing Information

To enter a license key:

1. On the vSMR, select Configuration > System > Licensing > Licenses.

2. Click Add.

The Add License page displays.

3. In the License field, type or paste the license key that you received.

4. Click Apply.

Reviewing License InformationAfter you enter a license, the Licenses page lists the information about the status of the license. To access the Licenses page, select Configuration > System > Licensing > Licenses.

The following items are listed on the Licenses page:

License—License key. Mouse-over the entry in the License column to view the key.

Feature—ShoreTel Mobility feature.

User Count—Number of users that can be added (applicable only for end-user licenses and dependent on the license that you purchased).

Valid—Displays that the license key has been entered correctly.

Deployment Guide ShoreTel Virtual Mobility Router 8

Page 12: ShoreTel Virtual Mobility Router Deployment Guide Mobility 9

Configuration Reviewing License Information2

If the license key has not been entered correctly (for example, some characters are missing, incorrect characters were entered, or extra characters were added), an X in a red box displays in the Valid column. Delete the license and add the license with the correct license key. When the license key has been entered correctly, a checkmark in a green box displays in the Valid column.

Active—License is activated.

The license is activated if the following criteria are met:

The license has not expired.

The MAC address of the Mobility Router matches the MAC address for the license.

When a license is activated, a checkmark in a green box displays in the Active column. If a license is not activated, an X in a red box displays in the Active column.

A license must be valid and active before you can use its feature. Table 1 lists the different states for the Valid and Active columns.

Start Date—Date from which license can first be activated.

End Date—Date on which license expires.

NoteWhen the license expires or there are more users than the license allows, the User’s Oper Status displays Disabled. The Admin Status displays Enabled. This helps the Administrator identify who the real enabled Users are on this Mobility Router. Find this display at Configuration > Groups and Users > Users.

Table 1: Description of Valid and Active States

Valid and Active States Description

Valid and Active The license key has been entered correctly. The license also meets the requirements for activation.

Valid and Inactive The license key has been validated by the Mobility Router, but the license does not meet the requirements for activation. Make sure that the license has not expired and that you are adding the correct license on the correct Mobility Router.

Invalid and Inactive The license key has not been entered correctly. Make sure that you entered the correct license key for the license.

Deployment Guide ShoreTel Virtual Mobility Router 9

Page 13: ShoreTel Virtual Mobility Router Deployment Guide Mobility 9

Configuration Deploying the Virtual Mobility Router in High Availability Mode2

Deploying the Virtual Mobility Router in High Availability Mode

The ShoreTel Virtual Mobility Router can be deployed in High Availability.

Configure the second vSMR following the procedure in Installing the Virtual Mobility Router on page 4. After completing these steps, add both of the vSMRs to an HA cluster using the steps outlined in the “Managing Redundancy Clusters” chapter of the ShoreTel Mobility Router Administration Guide. The procedures for deploying physical Mobility Routers and Virtual Mobility Routers in High Availability mode are identical.

Upgrading the Virtual Mobility RouterTo upgrade your ShoreTel Virtual Mobility Router, refer to the “Managing Mobility Router Images” section of the ShoreTel Mobility Router Administration Guide. The process for backing up, restoring, or upgrading a physical Mobility Router and a Virtual Mobility Router are identical.