shock damping and attenuation measurement

7
Shock Damping and Attenuation Deskto p Experiments 3/23/2017 rev A Don Blanchet 3B Associates [email protected]

Upload: don-blanchet

Post on 13-Apr-2017

26 views

Category:

Engineering


3 download

TRANSCRIPT

Page 1: Shock damping and attenuation measurement

Shock Damping and AttenuationDesktop Experiments

3/23/2017 rev ADon Blanchet

3B Associates

[email protected]

Page 2: Shock damping and attenuation measurement

Tools & Goals

Hammer “tap” testing shock measurements.

– Small hammer repeated blows

3 foot long steel pipe

– 1.6 inches diameter

– .060 inch wall thickness

– Free/free support – natural frequency ringing

MIDE slam stick model C data logger

– Measure acceleration time signal

– Process FFT and PSD

– Calculate attenuation in decibels – end to end

– Calculate damping %

Page 3: Shock damping and attenuation measurement

Data logger – triaxial accelerometer

Page 4: Shock damping and attenuation measurement

Input shock – material damping 260 hz ringing

Logarithmic decrement methodDamping = 0.87 %

Page 5: Shock damping and attenuation measurement

Processed - FFTs

-10db

-12db

-36db

Page 6: Shock damping and attenuation measurement

Where is this useful ?

Page 7: Shock damping and attenuation measurement

Where is this useful ?

0.0087