shimadzu ftir spectrophotometer
TRANSCRIPT
-
8/14/2019 SHIMADZU FTIR SPECTROPHOTOMETER
1/4
SpektroskopieSpectroscopy
FTIR
SEG-A-070-2-2
-
8/14/2019 SHIMADZU FTIR SPECTROPHOTOMETER
2/4
This instrument is for routine analysisin the middle infrared range. Due to thebuilt-in High-End devices the instru-ment features specifications enablinghigh resolution and an excellent signalto noise ratio. The optical, thermal andmoveable parts are controlled elec-tronically. The accompanying softwarepackage contains test functions forGLP, EP and ASTM and is FDA 21 CFRPart 11 compliant.
resolution of 0.5 cm -1 is idealfor identification of compounds,
even gases high signal-to-noise ratio for
measurements up to the detectionlimit
KRS-5 window for sealed optics andprotective coating for the hygroscopicKBr beamsplitter assure long lifetimeof the sensitive modules
easy maintenance with built-inautomatic desiccator
small installation space
IRAffinity-1Das IRAffinity-1 bietet HighEnd-Bau-teile fr die Routine-Analytik. Der mitt-lere Infrarot-Bereich wird dadurch mitSpezifikationen abgedeckt, die zuhoher Auflsung auch ein gutes Signal-Rausch-Verhltnis ergeben. Die beweg-lichen, optischen und thermischenBauteile werden elektronisch gesteu-ert. Die zugehrige Software enthltPrffunktionen fr GLP, EP und ASTM.FDA 21 CFR Part 11 ist ebenfalls erfllt.
Auflsung von 0,5 cm -1 ideal fr dieIdentifikation selbst von Gasen
hohes Signal-Rausch-Verhltnisfr Messungen bis an die Nachweis-grenzen
KRS-5 Fenster fr die gekapselteOptik und Schutzfilm fr den hygro-skopischen Strahlteiler aus KBrgewhren Langlebigkeit der empfind-lichen Bauteile
einfache Wartung durch integrierteLufttrocknung
platzsparendes Design
This instrument is designed for R& D,but can also be employed in the routinelaboratory and for educational purpos-
es. The IRPrestige-21 owes its high sen-sitivity to the high precision and excel-lent performance of the light sourcesand detectors as well as to the gold-plated mirrors and interferometer parts.Using the IRsolution software enableseasy switching from one applicationarea to the next. In addition, user-spe-cific methods are easily automated.
for NIR, MIR and FIR high resolution of 0.5 cm -1, the meas-
urement sensitivity can be furtherincreased using the MCT detector
control functions of the ADA togetherwith the FJS system lead to reliablemeasurements
self-diagnostics and automaticaccessory recognition
IRPrestige-21
Zwar konzipiert fr Forschung undEntwicklung, kann das IRPrestige-21genauso im Standardlabor eingesetztwerden wie in der Lehre. Seine groeEmpfindlichkeit basiert auf der hohenPrzision und Leistungsfhigkeit derLichtquellen und Detektoren sowie denvergoldeten Spiegeln in Zusammenar-beit mit dem Interferometerpart.
Mit der IRsolution Software ist eseinfach, von einem Applikationsfeldins andere zu wechseln. Zudem lassensich benutzerspezifische Methodenautomatisieren.
Technical alterations excepted Technische nderungen vorbehalten
SpektroskopieSpectroscopy
FTIR
triple protection system for sensitivecomponents
the IRsolution software features
validation functions in accordancewith international standards
fr NIR, MIR und FIR hohe Auflsung von 0,5 cm -1, Mess-
empfindlichkeit mit MCT-Detektornochmals steigerbar Kontrollfunktionen des ADA zusam-
men mit dem FJS-System ergebenvertrauenswrdige Messungen
Selbstdiagnose, automatischeZubehr-Erkennung
Dreifach Schutzsystem fr dieempfindlichen Bauteile Validierungsfunktionen gem
internationaler Normen in derIRsolution Software
-
8/14/2019 SHIMADZU FTIR SPECTROPHOTOMETER
3/4
The micro-ATR (Attenuated TotalReflectance) technique can be carriedout using the ATR-8800M objective.The built-in Germanium crystalenables analyses of blackened materi-als. The objective can be switchedbetween observation and IR measur-ing mode, and can be used for singleor area measurements. The instrumentis controlled via the software and thesample stage is positioned in accor-dance with the measuring techniqueapplied.
automatic control of the ATRmapping is integrated
easy, reproducible positioning ofthe crystal
Ge crystal for small penetrationdepth of approximately 1 m intothe sample surface
ATR-8800M
Die Mikro-ATR-Technik (Abgeschwch-te Total-Reflexion) lsst sich mit demObjektiv ATR-8800M realisieren. Daseingebaute Germanium-Kristall erlaubt
die Analyse von geschwrzten Materi-alien. Das Objektiv wird zwischenBeobachtungsmodus und IR-Mess-
Technische nderungen vorbehalten Technical alterations excepted
The IRsolution software is the linkbetween instrument and accessories,for instance using video devices forthe infrared microscope. Displayoptions in 3D or 4D are possible. Thesoftware contains integrated modulesto enable autosampler operation in theNIR or MIR mode.
library search, quantification,multi-component analysis
"EasyScan" function for simple andfast measurements, modules guidingthrough validation function
CFR components, data history,audit trail
high functionality, can be extendedto additional application areas aswell as PLS and peak separation
"Foreign Material Analysis" programand "Pharmacopoeia Compatible"program for substance control areintegrated as standard
IRsolutionDie IRsolution Software verbindet dieInstrumente mit den Zubehren, ein-schlielich den Videooptionen, etwabeim Infrarot-Mikroskop. Anzeige-optionen in 3D und 4D sind mglich.In die Software sind auch Moduleintegriert, die es ermglichen, im NIRwie MIR mit einem Autosampler zuarbeiten.
Bibliothekssuche, Quantifizierung,Mehr-Komponentenanalytik
EasyScan fr einfache schnelleMessung, Module fhren durch die
Validierung CFR-Komponenten, Dateihistorien,
Audit-Trail hohe Funktionalitt, erweiterbar
um zustzliche Applikationsfelder,wie PLS und Peakseparation
Foreign Material AnalysisProgramm und PharmacopoeiaCompatible Programm zur Substanz-kontrolle standardmig integriert
The FTIR instrument line is extendedfurther to microanalysis applicationsby incorporating the AIM-8800 infraredmicroscope, with highest ease ofoperation. Using the AIMVIEW soft-ware, automation can be effectedwith the click of a mouse. Mappingsoftware enables 3D and 4D measure-ments and displays.
highly sensitive MCT detector for
accurate measurements reproducible measurement positionsvia 3D sample stage
reflectance and transmissionmeasurements as standard
AIM-8800
Das Infrarotmikroskop AIM-8800erweitert die FTI R-Instrumentenliniefr die Mikroanalytik bei hchstemKomfort fr den Nutzer. Mittels der
AIMVIEW Software wird die Automati-sierung per Mausklick gesteuert. EineMapping-Software erlaubt 3D- und4D-Messungen und -Darstellungen.
hochempfindlicher MCT-Detektor frakkurate Messungen
reproduzierbare Messpositionendurch 3D-Probentisch
Reflexions- und Transmissions-messungen sind Standard
auergewhnliche Messauflsungvon 1 m in der Positionierung derProbe
automatische Apertur zumMaskieren der Probe integrierte CCD-Kamera und Bild-
verarbeitung erlauben die Arbeit aneinem PC-Monitor
excellent resolution of 1 m forpositioning of the sample
automatic aperture for masking thesample
integrated CCD camera and pictureprocessing facilitate the use of a PCmonitor
modus geschaltet und kann fr Einzel-oder Bereichsmessungen eingesetztwerden. ber die Software wird dasSystem gesteuert und der Probentischentsprechend der Messtechnik posi-tioniert.
automatische Kontrolle desATR-Mappings ist integriert
einfache, reproduzierbare Positio-
nierung des Kristalls Ge-Kristall fr kleine Eindringtiefenvon ca. 1 m in die Oberflchen
-
8/14/2019 SHIMADZU FTIR SPECTROPHOTOMETER
4/4
FTIR
Shimadzu Europa GmbH
Albert-Hahn-Str. 6-10 D-47269 Duisburg
Tel.: +49 - (0)203 - 76 87-0
Fax: +49 - (0)203 - 76 66 25
Email: [email protected]
To find your local Shimadzu contact
please visit www.shimadzu.eu
2.0
/D.E
/N3/08/3/L
ME-
DUS.C
OM
FTIR is an analytical technique of
increasing importance and is used in
a wide range of application areas for
qualitative analyses as well as quanti-
tative determinations. Numerous
measuring accessories are available
for just about any analytical require-
ment, whether for NIR-, MIR- or FIR
range measurements or for the deter-
mination of aggregation states of
sample materials. Quantitative deter-
minations require accessories that
are easy to use and that lead to
reproducible results, for instance
single-reflectance units.
sample compartment for Shimadzu
accessories or those of other manu-
facturers
classical accessories for transmis-
sion measurements
Accessories Zubehr
Analysen mit der FTIR-Technik sind
sehr umfangreich geworden. Neben
qualitative Analysen sind die Gehalts-
bestimmungen getreten. Es gibt zahl-
reiche Mess-Zustze fr fast jede
Anforderung, ob fr die Messbereiche
NIR, MIR oder FIR oder fr den Aggre-
gatszustand des Probenmaterials.
Gehaltsbestimmungen erfordern ein
Zubehr, das einfach zu bedienen ist
und reproduzierbar arbeitet, wie zum
Beispiel Einfach-Reflexionseinheiten.
reflectance units for targeted diffuse
and attenuated total reflectance
special accessories for microscopy
and NIR measurements
autosampler for transmission and
reflectance measurements
spectral libraries from various
suppliers
Probenraum fr Zubehre von
Shimadzu und anderen Herstellern
klassische Zubehre fr die Trans-
missionsmessungen
Reflexionseinheiten fr gerichtete,
diffuse und abgeschwchte Total-
reflexion
Spezialzubehr fr Mikroskopie
und NIR-Messtechnik
Autosampler fr Transmissions-
und Reflexionsmessungen
Bibliotheken von verschiedensten
Anbietern