shenzhen xsy lighting co.,ltd led linear high bay type b...tel: +86-755-29549953 e-mail:...
TRANSCRIPT
LED LINEAR HIGH BAY Type B
◆ UL/CUL/DLC , UL file NO.: E357402
◆ 2019 new design with private mold
◆ Seoul 2835SMD LED
◆ 140lm/w ,14700-42000Lm
◆ 120-277V/120-347V/277-480V op�onal
◆ Integrated enclosure design
◆ Microwave sensor and Emergency backup
available
◆ Chain kit / Surface mounted / Pendant hanger
installa�on op�onal
◆ 5 years warranty
Applica�on:
• Manufacturing Plants
• Warehouses
• Distribu�on Centers
• Grocery Stores
• Gymnasiums
LISTEDE357402
Shenzhen XSY Lighting Co.,Ltd
Features
Parameters
XSY-LHB2P105-XXK-YB-EF
XSY-LHB2P165-XXK-YB-EF
XSY-LHB2P225-XXK-YB-EF
XSY-LHB4P165-XXK-YB-EF
XSY-LHB4P225-XXK-YB-EF
XSY-LHB4P300-XXK-YB-EF
XSY-LHB2P105-XXK-HV-YB-EF
XSY-LHB2P165-XXK-HV-YB-EF
XSY-LHB4P225-XXK-HV-YB-EF
XSY-LHB4P300-XXK-HV-YB-EF
Size Efficacy LumenInput
voltagePowerBeam angle
CRI CCTModel #
2FT
4FT
2FT
4FT
105W
165W
225W
300W
105W
165W
225W
225W
300W
AC120-277V
AC120-347V
AC277-480V
140LM/W
14700LM
23100LM
31500LM
165W 23100LM
31500LM
42000LM
14700LM
23100LM
31500LM
42000LM
120° >80
4000K
5000K
5700K
Tel: +86-755-29549953 E-mail: [email protected] www.xsylights.com
Housing
Mo�on sensor
DC12V sensor
Emergency backup
UL listed, 90min , suitable for different size EM backup
LED Driver
Class 2, Class P driverAC120-277V, AC120-347V, AC277-480V op�onal
PaintHighly Reflec�ve Metal Paint, achieve op�mal apperance design
StructureOnly 1.7’’ thickness, super thin design
Integrated enclosuredesign
Ordering Guide For example: XSY-LHB2P165-40K-HA-EF
Brand
XSY
Fixture
Linear
Highbay
Size
2 2FT
4 4FT
CCT
40K 4000K
50K 5000K
57K 5700K
Input voltage
Blank AC120-277V
HL AC120-347V
HV 277-480V
Lumen
H High
L Standard
Type
A Type A
B Type B
Sensor
A With
B Without
Moun�ng
A Suspending
B Surface
C pendant
Acessories
Dimension
Tel: +86-755-29549953 E-mail: [email protected] www.xsylights.com
Power
105W
165W
225W
300W
XSY LHB 2 P165 40K H A E F
23.03"
15.75"
1.84"
1.18"
46.06"
400
1.18"
1.84"
Chain Surface mount Pendant Mount
Photometric
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:c d
C0/180,100. 6
UNIT:c d
C30/210,101. 5
UNIT:c d
C60/240,104. 6
UNIT:c d
C90/270,104. 9AVERAGE BEAM ANGLE(50%):102.9 DEG
0
1200
2400
3600
4800
6000
105W 2� 5000K 165W 2� 5000K
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:c d
C0/180,99. 8
UNIT:c d
C30/210,100. 9
UNIT:c d
C60/240,104. 6
UNIT:c d
C90/270,105. 0AVERAGE BEAM ANGLE(50%):102.6 DEG
0
3000
6000
9000
12000
15000
225W 2� 5000K 165W 4� 5000K
225W 4� 5000K 300W 4� 5000K
Tel: +86-755-29549953 E-mail: [email protected] www.xsylights.com
1. Chain installa�on
1. Hook the chain 2. Insert the hook into the slo�ed
holes as shown
3.Hook up the chain on the ceiling
anchor
Installa�onALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
2 4 0 . 8 6 c m
4 8 1 . 7 3 c m
7 2 2 . 5 9 c m.
9 6 3 . 4 6 c m
1 2 0 4 . 3 2 c m
1 4 4 5 . 1 8 c m
1 6 8 6 . 0 5 c m
1 9 2 6 . 9 1 c m
2 1 6 7 . 7 8 c m
2 4 0 8 . 6 4 c m
D i a m e t e r
o :
2. Surface Moun�ng installa�on
3. Pendant Mount installa�on
Tel: +86-755-29549953 E-mail: [email protected] www.xsylights.com
6. Wiring L, N, E into the terminal block. Fasten
the two end caps on the ceiling bracket and
lock theM4 screw 1pcs.
3. Use the tool to open 4 holes at the
top, and then fix the ceiling bracket
4. Remove the iron piece for easy
wiring.
5. Li� the lamp into the bracket, align the
side holes, and lock the M5 screws.
1. Drill the hole according to the size of
the bracket and insert the plas�c
expansion tube.
Diagram 2
27mm(1.0
6inch)
80mm(3.15inch)
90mm
(3.5
4inc
h)
2. Use a hammer to drive the nylon
expansion tube into the drilled
hole on the wall.
2. Lift the screw holes of the fixture to align the
bracket screws, and then tighten with the
M5 * 6screws.
1. Thread the 3/4 inch conduit into
the holeof upper box, and screw
the nut at end.
3. Disassemble the terminal block, insert the
wires L, N,E in the hollow tube into the
terminal block, and see the signs L, N, E.
Install the terminal block locking screws.
Reinstall the cover plates at both ends.
4. Turn off power, then make wiring
Connec�ons with terminal cap
5. Insert the terminal cap and wire
into the driver box
6. Insert the wire terminal joint
to the wire entry
Model
2FT 105W
2FT 165W
2FT 225W
4FT 165W
4FT 225W
4FT 300W
Carton Dimension
Package Info.
Safety Precau�onTo reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other
hazards read all warnings and instruc�ons included with and on the fixture box and all fixture labels.
Before installing, servicing, or performing rou�ne maintenance upon this equipment, follow these general precau�ons.
Commercial installa�on, service and maintenance of luminaires should be performed by a qualified licensed electrician.
For The installa�on: If you are unsure about the installa�on or maintenance of the luminaires, consult a qualified licensed electrician
and check your local electrical code.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installa�on.
WARNING: RISK OF FIRE OR ELECTRICAL SHOCK
Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
Turn off the power when you perform any maintenance.
Verify that supply voltage is correct by comparing it with the luminaire label informa�on.
Make all electrical and grounded connec�ons in accordance with the Na�onal Electrical Code and any applicable local code
requirements.
All wiring connec�ons should be capped with UL approved wire connectors.
CAUTION: RISK OF INJURY
Avoid direct eye exposure to the light source while it is on.
Account for small parts and destroy packing material, as these may be hazardous to children.
SUITABLE FOR DRY OR DAMP LOCATION
www.xsylights.com
25.39’’*6.77’’*17.91’’
48.43’’*6.77’’*17.91’’
Qty / Carton
2PCS
2PCS
N.W
17.2lbs
15.52lbs
19.4lbs
30.86lbs
31.75lbs
33.95lbs
G.W
21.16Ibs
23.15lbs
24.25lbs
37.04lbs
37.92lbs
40.12lbs
20GP
960PCS
500PCS
40HQ
2640PCS
1374PCS
Add:10-11/F ,No.2 Building, Hengchangrong High Tech Ind. Park, ShangnanEast Rd, Hong�an, Shajing Town, Bao'an District, ShenzhenTel: 0086-755-29549953 Email: [email protected]