shenzhen xsy lighting co.,ltd led linear high bay type b...tel: +86-755-29549953 e-mail:...

6
LED LINEAR HIGH BAY Type B UL/CUL/DLC , UL file NO.: E357402 2019 new design with private mold Seoul 2835SMD LED 140lm/w ,14700-42000Lm 120-277V/120-347V/277-480V oponal Integrated enclosure design Microwave sensor and Emergency backup available Chain kit / Surface mounted / Pendant hanger installaon oponal 5 years warranty Applicaon: • Manufacturing Plants • Warehouses • Distribuon Centers • Grocery Stores • Gymnasiums LISTED E357402 Shenzhen XSY Lighting Co.,Ltd Features

Upload: others

Post on 08-Nov-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Shenzhen XSY Lighting Co.,Ltd LED LINEAR HIGH BAY Type B...Tel: +86-755-29549953 E-mail: sales@xsylights.com 6. Wiring L, N, E into the terminal block. Fasten the two end caps on the

LED LINEAR HIGH BAY Type B

◆ UL/CUL/DLC , UL file NO.: E357402

◆ 2019 new design with private mold

◆ Seoul 2835SMD LED

◆ 140lm/w ,14700-42000Lm

◆ 120-277V/120-347V/277-480V op�onal

◆ Integrated enclosure design

◆ Microwave sensor and Emergency backup

available

◆ Chain kit / Surface mounted / Pendant hanger

installa�on op�onal

◆ 5 years warranty

Applica�on:

• Manufacturing Plants

• Warehouses

• Distribu�on Centers

• Grocery Stores

• Gymnasiums

LISTEDE357402

Shenzhen XSY Lighting Co.,Ltd

Features

Page 2: Shenzhen XSY Lighting Co.,Ltd LED LINEAR HIGH BAY Type B...Tel: +86-755-29549953 E-mail: sales@xsylights.com 6. Wiring L, N, E into the terminal block. Fasten the two end caps on the

Parameters

XSY-LHB2P105-XXK-YB-EF

XSY-LHB2P165-XXK-YB-EF

XSY-LHB2P225-XXK-YB-EF

XSY-LHB4P165-XXK-YB-EF

XSY-LHB4P225-XXK-YB-EF

XSY-LHB4P300-XXK-YB-EF

XSY-LHB2P105-XXK-HV-YB-EF

XSY-LHB2P165-XXK-HV-YB-EF

XSY-LHB4P225-XXK-HV-YB-EF

XSY-LHB4P300-XXK-HV-YB-EF

Size Efficacy LumenInput

voltagePowerBeam angle

CRI CCTModel #

2FT

4FT

2FT

4FT

105W

165W

225W

300W

105W

165W

225W

225W

300W

AC120-277V

AC120-347V

AC277-480V

140LM/W

14700LM

23100LM

31500LM

165W 23100LM

31500LM

42000LM

14700LM

23100LM

31500LM

42000LM

120° >80

4000K

5000K

5700K

Tel: +86-755-29549953 E-mail: [email protected] www.xsylights.com

Housing

Mo�on sensor

DC12V sensor

Emergency backup

UL listed, 90min , suitable for different size EM backup

LED Driver

Class 2, Class P driverAC120-277V, AC120-347V, AC277-480V op�onal

PaintHighly Reflec�ve Metal Paint, achieve op�mal apperance design

StructureOnly 1.7’’ thickness, super thin design

Integrated enclosuredesign

Page 3: Shenzhen XSY Lighting Co.,Ltd LED LINEAR HIGH BAY Type B...Tel: +86-755-29549953 E-mail: sales@xsylights.com 6. Wiring L, N, E into the terminal block. Fasten the two end caps on the

Ordering Guide For example: XSY-LHB2P165-40K-HA-EF

Brand

XSY

Fixture

Linear

Highbay

Size

2 2FT

4 4FT

CCT

40K 4000K

50K 5000K

57K 5700K

Input voltage

Blank AC120-277V

HL AC120-347V

HV 277-480V

Lumen

H High

L Standard

Type

A Type A

B Type B

Sensor

A With

B Without

Moun�ng

A Suspending

B Surface

C pendant

Acessories

Dimension

Tel: +86-755-29549953 E-mail: [email protected] www.xsylights.com

Power

105W

165W

225W

300W

XSY LHB 2 P165 40K H A E F

23.03"

15.75"

1.84"

1.18"

46.06"

400

1.18"

1.84"

Chain Surface mount Pendant Mount

Page 4: Shenzhen XSY Lighting Co.,Ltd LED LINEAR HIGH BAY Type B...Tel: +86-755-29549953 E-mail: sales@xsylights.com 6. Wiring L, N, E into the terminal block. Fasten the two end caps on the

Photometric

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

-30

UNIT:c d

C0/180,100. 6

UNIT:c d

C30/210,101. 5

UNIT:c d

C60/240,104. 6

UNIT:c d

C90/270,104. 9AVERAGE BEAM ANGLE(50%):102.9 DEG

0

1200

2400

3600

4800

6000

105W 2� 5000K 165W 2� 5000K

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

-30

UNIT:c d

C0/180,99. 8

UNIT:c d

C30/210,100. 9

UNIT:c d

C60/240,104. 6

UNIT:c d

C90/270,105. 0AVERAGE BEAM ANGLE(50%):102.6 DEG

0

3000

6000

9000

12000

15000

225W 2� 5000K 165W 4� 5000K

225W 4� 5000K 300W 4� 5000K

Tel: +86-755-29549953 E-mail: [email protected] www.xsylights.com

1. Chain installa�on

1. Hook the chain 2. Insert the hook into the slo�ed

holes as shown

3.Hook up the chain on the ceiling

anchor

Installa�onALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!

2 4 0 . 8 6 c m

4 8 1 . 7 3 c m

7 2 2 . 5 9 c m.

9 6 3 . 4 6 c m

1 2 0 4 . 3 2 c m

1 4 4 5 . 1 8 c m

1 6 8 6 . 0 5 c m

1 9 2 6 . 9 1 c m

2 1 6 7 . 7 8 c m

2 4 0 8 . 6 4 c m

D i a m e t e r

o :

Page 5: Shenzhen XSY Lighting Co.,Ltd LED LINEAR HIGH BAY Type B...Tel: +86-755-29549953 E-mail: sales@xsylights.com 6. Wiring L, N, E into the terminal block. Fasten the two end caps on the

2. Surface Moun�ng installa�on

3. Pendant Mount installa�on

Tel: +86-755-29549953 E-mail: [email protected] www.xsylights.com

6. Wiring L, N, E into the terminal block. Fasten

the two end caps on the ceiling bracket and

lock theM4 screw 1pcs.

3. Use the tool to open 4 holes at the

top, and then fix the ceiling bracket

4. Remove the iron piece for easy

wiring.

5. Li� the lamp into the bracket, align the

side holes, and lock the M5 screws.

1. Drill the hole according to the size of

the bracket and insert the plas�c

expansion tube.

Diagram 2

27mm(1.0

6inch)

80mm(3.15inch)

90mm

(3.5

4inc

h)

2. Use a hammer to drive the nylon

expansion tube into the drilled

hole on the wall.

2. Lift the screw holes of the fixture to align the

bracket screws, and then tighten with the

M5 * 6screws.

1. Thread the 3/4 inch conduit into

the holeof upper box, and screw

the nut at end.

3. Disassemble the terminal block, insert the

wires L, N,E in the hollow tube into the

terminal block, and see the signs L, N, E.

Install the terminal block locking screws.

Reinstall the cover plates at both ends.

4. Turn off power, then make wiring

Connec�ons with terminal cap

5. Insert the terminal cap and wire

into the driver box

6. Insert the wire terminal joint

to the wire entry

Page 6: Shenzhen XSY Lighting Co.,Ltd LED LINEAR HIGH BAY Type B...Tel: +86-755-29549953 E-mail: sales@xsylights.com 6. Wiring L, N, E into the terminal block. Fasten the two end caps on the

Model

2FT 105W

2FT 165W

2FT 225W

4FT 165W

4FT 225W

4FT 300W

Carton Dimension

Package Info.

Safety Precau�onTo reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other

hazards read all warnings and instruc�ons included with and on the fixture box and all fixture labels.

Before installing, servicing, or performing rou�ne maintenance upon this equipment, follow these general precau�ons.

Commercial installa�on, service and maintenance of luminaires should be performed by a qualified licensed electrician.

For The installa�on: If you are unsure about the installa�on or maintenance of the luminaires, consult a qualified licensed electrician

and check your local electrical code.

To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installa�on.

WARNING: RISK OF FIRE OR ELECTRICAL SHOCK

Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.

Turn off the power when you perform any maintenance.

Verify that supply voltage is correct by comparing it with the luminaire label informa�on.

Make all electrical and grounded connec�ons in accordance with the Na�onal Electrical Code and any applicable local code

requirements.

All wiring connec�ons should be capped with UL approved wire connectors.

CAUTION: RISK OF INJURY

Avoid direct eye exposure to the light source while it is on.

Account for small parts and destroy packing material, as these may be hazardous to children.

SUITABLE FOR DRY OR DAMP LOCATION

www.xsylights.com

25.39’’*6.77’’*17.91’’

48.43’’*6.77’’*17.91’’

Qty / Carton

2PCS

2PCS

N.W

17.2lbs

15.52lbs

19.4lbs

30.86lbs

31.75lbs

33.95lbs

G.W

21.16Ibs

23.15lbs

24.25lbs

37.04lbs

37.92lbs

40.12lbs

20GP

960PCS

500PCS

40HQ

2640PCS

1374PCS

Add:10-11/F ,No.2 Building, Hengchangrong High Tech Ind. Park, ShangnanEast Rd, Hong�an, Shajing Town, Bao'an District, ShenzhenTel: 0086-755-29549953 Email: [email protected]

Shenzhen XSY Lighting Co.,Ltd

4. Cover the two sides of the cover and lock

the M4 screw 1pcs.

5. Check if the assembly is installed and then

power on.