servomotor replacement

Upload: amitdhupar666

Post on 04-Jun-2018

230 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/13/2019 SERVOMOTOR Replacement

    1/5

    Servo Motor Assembly Dowel removing procedure 29 Jan 2005

    Machine condi tion before start up the dowel removing work:

    A) Mold Mold Upper and Lower Mold Should be in Close condition.

    B) Switch Off the Machine power supply

    D) Blow Core should be at the Down condition.

    E) Cover the Blow core / Strech area with Polybag for protection.

    Procedure: Please follow the procedure mentioned in the following steps:

    1) Disconnect Servo Motor Connector and Encoder Cable Connector.

    C) Switch off the operational Air and drain / exhaust the operational Air from the

    system (Operating Circuit)

    2) Remove Motor mounting bolts (M8X20 - 4

    Nos.)

    Mark a Line on Servo Motor,

    Mounting flange and Gear Box for

    positioning.

    Prepared by: Sangeet Page 1 of 10

  • 8/13/2019 SERVOMOTOR Replacement

    2/5

    Servo Motor Assembly Dowel removing procedure 29 Jan 2005

    Precaution : Upper part of Servo

    Motor ( Encoder area) should not

    touch any part of Machine.

    3) Remove Servo Motor carefully. (Upper part Encoder should not touch to any

    Machine part)_

    4) Remove M6 X 70 Bolts (7 Nos.) fixed on the Motor Mounting Base.

    5) Fix 2 nos. bolts (M8 X 40) for lifting the Servo Motor Mounting Base.

    Prepared by: Sangeet Page 2 of 10

  • 8/13/2019 SERVOMOTOR Replacement

    3/5

    Servo Motor Assembly Dowel removing procedure 29 Jan 2005

    Step 8. Fix Servo Motor Mounting Base.(Match as per the Marked line).

    11) Mount Servo Motor: Motor connection cable junction Box direction will be

    towards Upper Mold. (Match as per the Marked line).

    10) Fix Motor mounting Base and fix M6 X 70 Bolts (7 Nos.). Keep loose the Bolts.

    Do not hammer on the Servo Motor

    upper part (Encoder area)

    Prepared by: Sangeet Page 8 of 10

  • 8/13/2019 SERVOMOTOR Replacement

    4/5

    Servo Motor Assembly Dowel removing procedure 29 Jan 2005

    12) Fix Motor mounting Bolts (M8 X 20) 4 Nos. And keep the bolts in loose

    condition.

    13) Tight the Servo Motor Mounting

    base bolts (M6 X 70 ) 7 Nos.

    14) Tight the Servo Motor Mounting

    bolts (M8 X 20) 4 Nos.

    Prepared by: Sangeet Page 9 of 10

  • 8/13/2019 SERVOMOTOR Replacement

    5/5

    Servo Motor Assembly Dowel removing procedure 29 Jan 2005

    Clean the Upper Base area properly.Ensure any tool not left at the work area.

    As it generates the Servo Setting OK alarm.

    2) Switch on Operational Air.

    3) Start pump motor and open Blow Mold and Injection Mold (Upper and Lower

    mold).

    4) Reset the Servo Motor positioning as per the below procedure:

    This is end of the procedure.

    Remark: Please ensure correct setting of speed control Valve for Strech Cylinder.

    1) Switch on the Machine Power supply (QF1).

    15) Connect Servo Motor supply cable connector and Encoder Cable connector.

    Hidden parameter ----Set Servo Bit 1 ----Rotate table in Forward condition in set

    mode.

    Prepared by: Sangeet Page 10 of 10