series ii walvit + cube - plumbing mall.com · 2020. 12. 21. · • 3.5"/90mm min. inwall...
TRANSCRIPT
INVISI™
SERIES II
1.28/0.8 Gal (4.8/3 Litre)concealed cistern237060, 237061 & 237062
SERIES II WALVIT + CUBE
1.28/0.8 Gal (4.8/3 Litre)Concealed Tank237061 + 237062
INVISI™
SERIES II
Contents
2
5 Step Easy Install ................................................................................................. 3
Installation Requirements ...................................................................................... 3
Tank Service Access Options ................................................................................ 4
Button Service Access Options ............................................................................. 5
Installing the Tank - 237 061 Inwall Access .................................................................................................. 6
Induct Access ................................................................................................... 8
Where adjustment of the tank height is required ............................................. 9
Installing the Tank - 237 062 Under Counter Access .................................................................................. 10
Optional Remote Mounting Box Kit - 237 006 .................................................... 11
Access Panel Variations ...................................................................................... 11
Preparation for Fitout ........................................................................................... 12
Removing Internal Components through Access Window................................... 13
Servicing - Outlet Valve ....................................................................................... 14
Servicing - Inlet Valve .......................................................................................... 15
Important Notices ................................................................................................ 16
Helplines .............................................................................................................. 16
INVISI™
SERIES IIINVISI™
SERIES II
5 Step Easy Install
Installation Requirements
1 2 3 4 5
3
237 060 - Invisi II 4.8/3L Dual Flush Tank
CONTENTS
• InvisiII-4.8/3LConcealedTank•MountingBrackets• TallFlushPipe• 19.7"/0.5mofPneumaticTube• TankFixingPack• BrassWaterSupplyFitting
237 061 - Invisi II 4.8/3L Dual Flush Tank - with Standard Wall Hung Bowl Bracket
CONTENTS
• InvisiII-4.8/3LConcealedTank•MountingBrackets• Inwall,WallHungBowlBracket• TallFlushPipe• 19.7"/0.5mofPneumaticTube• 3.5"/90mmWastePipe• BowlBracketFixingPack• BrassWaterSupplyFitting
REQUIREMENTS
• 3.5"/90mmMin.InwallCavityDepth• 15.75"/400mmMin.-16.5”/420mmMaxCavityWidth(e.g.betweenstuds)
• 15/16"-14NS-1WaterConnectionsuppliedwithadaptorto½"Coppersolderor FIP
REQUIREMENTS
• 3.5"/90mmMin.InwallCavityDepth• 15.75"/400mmMin.-16.5"/420mmMaxCavityWidth(e.g.betweenstuds)
• 15/16"-14NS-1WaterConnectionsuppliedwithadaptorto½"Coppersolderor FIP
237 062 - Invisi II 4.8/3L Dual Flush Tank - with Under Counter Wall Hung Bowl Bracket
CONTENTS
• InvisiII-4.8/3LConcealedTank•MountingBrackets• UnderCounter,WallHungBowl
Bracket• ShortFlushPipe• 19.7"/0.5mofPneumaticTube• 3.5"/90mmWastePipe• BowlBracketFixingPack• BrassWaterSupplyFitting
REQUIREMENTS
• 33.5"/850mmMin.Heighttoundercounter• 3.5"/90mmMin.(FrontMountButtonPanel)3.9"/100mmMin.(TopMountButtonPanel)InwallCavityDepth
• 15.75"/400mmMin-16.5"/420mmMaxCavityWidth(e.g.betweenstuds)
• 15/16"-14NS-1WaterConnectionsuppliedwithadaptorto½"Coppersolderor FIP
NOTE:Non-compressiblematerialmustbeinstalledbehindthebowl.
Check Installation
Requirements
Select Tank Service
Access Options
Select Button Service
Access Options
Installing the Tank
Preparation for Fitout
INVISI™
SERIES II
Tank Service Access Options
4
Inwall Access
Thisallowsaccesstotankinternalsthroughthebuttonpanelwindow.Standardinstallationrequiresnochangetoproductconfiguration.
AnoptionalRemoteMountingBoxKit(refertopage11)isrequiredifusingRemoteButtonPaneland/orextendingtheflushpipe.
Induct Access
This allows access to the whole tank. Standard installation will requireRemoteMountingBoxKit(refertopage11)forusewithRemote Button Panel.
Under Counter Access
Thisallowsaccesstotankinternalsthroughthebuttonpanelwindow.Standardinstallationrequiresnochangetoproductconfiguration.
OptionalTopAccesswillrequiretheaccesspaneltobeconverted(refertopage11).
INVISI™
SERIES IIINVISI™
SERIES II
Button Service Access Options
5
Direct Panel Mounting - Front
Thisissuitableforusewithanyofthebuttonpanelkits.
Requiresa0.2"(5mm)minimum-1.8"(45mm)maximumwallthickness.
Access to the tank internals is provided through the panel window.
Remote Panel Mounting
Thisissuitableforusewithanyofthebuttonpanelkits.
Requiresa0.2"(5mm)minimum-1.8"(45mm)maximumwallthickness.
A Blank Access Panel is required for inwall access to tank internals.
Remote Button Mounting
Accesstotherearofthebuttonsmustbeprovidedforservicing.
Suitableformountingthroughpanelsupto2.2"(55mm)thick.
A Blank Access Panel is required for inwall access to tank internals.
Care Button Panel
ACareButtonPanelisavailableforuse in ADA applications.
Direct Panel Mounting - Top
Thisissuitableforusewithanyofthebuttonpanelkits.
Requiresa0.2"(5mm)minimum-1.8"(45mm)maximumwallthickness.
Access to the tank internals is provided through the panel window.
INVISI™
SERIES II
Installing the Tank - 237 061
Inwall Access
Caroma Invisi II IntegratedWall Hung Bowl Bracket
Accurate positioning of the soil pipe relative to studwork is essential.
3.5" (90mm) Min.Cavity Depth
Finished Floor Level
Soil Pipe
Waste Pipe
6 ¼"
8 ¼"
15.75" - 16.5"(400mm - 420mm)
1.8" (45mm) – Water Supply Connection
Datum A
Datum B Front edge of3.5" (90mm) Stud
0.2" (5mm) Min.1.8"(45mm) Max.
Wall Thickness
Centre Line Buttons(standard mounting)
Stud Wall Installation(for non-structural floor)
To achieve a minimum wall cavity of 3.5" or 90mm the soil pipe must be accurately centred.
22.9" (582mm) Suppliedto centre of inlet
(adjustable from 16.2" - 22.9"or 412mm - 582mm)
Height to centre of the selected bowl’s inlet
Hole #1
Hole #3
Hole #1
Height to centre of the selected bowl's waste outlet to achieve 17”
ADA seat height
NOTE: Non compressable material must be used behind the bowl, from Datum A to floor
Use Hole #1 for Walvit Bowl 7 7/8 CLUse Hole #3 for Cube Bowl 7 1/8 CL
See page 8 for detailed rough-in instructions
TheCaromaCubeandWalvitaretheonlybowlscurrentlyapprovedtobeusedwiththeInvisibracket.
6
INVISI™
SERIES IIINVISI™
SERIES II
Installing the Tank - 237 061
Inwall Access - continued
1
2
3
“click”“click”
Dust Cover
ON OFF
4
Datum A
123
Water Supply Connection
Installing the Tank - 237 061
Inwall Access
Caroma Invisi II IntegratedWall Hung Bowl Bracket
Accurate positioning of the soil pipe relative to studwork is essential.
3.5" (90mm) Min.Cavity Depth
Finished Floor Level
Soil Pipe
Waste Pipe
6 ¼"
8 ¼"
15.75" - 16.5"(400mm - 420mm)
1.8" (45mm) – Water Supply Connection
Datum A
Datum B Front edge of3.5" (90mm) Stud
0.2" (5mm) Min.1.8"(45mm) Max.
Wall Thickness
Centre Line Buttons(standard mounting)
Stud Wall Installation(for non-structural floor)
To achieve a minimum wall cavity of 3.5" or 90mm the soil pipe must be accurately centred.
22.9" (582mm) Suppliedto centre of inlet
(adjustable from 16.2" - 22.9"or 412mm - 582mm)
Height to centre of the selected bowl’s inlet
Hole #1
Hole #3
Hole #1
Height to centre of the selected bowl's waste outlet to achieve 17”
ADA seat height
NOTE: Non compressable material must be used behind the bowl, from Datum A to floor
Use Hole #1 for Walvit Bowl 7 7/8 CLUse Hole #3 for Cube Bowl 7 1/8 CL
7
1. Checkthatthe4"(100mm)soilpipeiscentredbetweenthestuds-checkthereis15.75"-16.5"(400-420mm)betweenthestuds(17.7"or450mm nominal to studcentres).
2. Calculatethefinishedfloorheight(allowingforfloorgradingsandtilethick-ness,etc.)andaddthistotheknownheightoftheselectedbowl'sinlet.Markthis resulting height on the stud - This is your “Datum A” and flush pipe centre line.
NOTE: This is your “Datum A” and flush pipe centre line. From finished floor to centre of waste pipe is 8 ¼". From finished floor to centre of flushpipe is 14 ½" to achieve 17" seat height. See diagram on page 6.
3. Measure and ensure the Flush Pipe Centre Line which is marked on the Bowl Bracket is at the correct height. This should match the Datum A previously established.Useanallenkeytoadjust.Ensureboltsaretightenedaftersetting.
4. Placethebowlbracket&tankas-semblyinpositionandmarkoutall4boltlocationsinthebracketfeet.
NOTE: The front face of the bowl bracket should be flush with the front face of the studs (“Datum B”) & the 4" (100mm) soil pipe should be centred in both the wall cavity and between studs as well as being cut flush with the floor. (Depending on code approv-als in your area: if it is 4" then the insert fitting is used and it is cut flush. If the connection is 3" it is below the floor and the supplied waste pipe is long enough to go through the floor).
9. Screw in threaded rods for mounting the bowlandlockinpositionwithnutsagainstthe Front Plate. Three hole spacings are provided: 1-7.9”or200mm.UseHole#1forWalvitBowls.2-11”or280mm.3-7”or180mm.UseHole#3forCubeBowls.
10. Screw the tank in place using at least 1 of the 2 holes provided in the top of each mountingbracket.Makesurethewatercon-nectionfittingisonthelefthandsideoftankandtankisflushwithwall.
11. Connect the water supply with 15/16 14NS-1fittingandadaptorfittingfor1/2"bothsupplied.
12. RemoveDustCover,turnIsolatingTapON,filltank&setwaterlevelusingAdjust-ing Screw on the inlet valve.
13. Check tank and all joints for leaks.
14. Turn Isolating Tap OFF. Continue with Preparation for Fitout on page 12.
5. MoveBowlBracket&TankAssemblyout of its installation position and drill the 4 holesinthefloorasmarked.Carriermustbeanchoredsecurelytothefloor.
For Structural Flooring (concrete)Drill Ø0.5"or12mmholeforusewithM12TRU Bolts supplied in pack.
For Non Structural Flooring (wood)Drilltosuitfixingsused(fixingsnotsup-plied).Theverticalarmsofthebowlbracketmustalsobeboltedtosidestuds.
6. LubricatetheWastePipewithsoapandwater and push into the soil pipe. Carefully repositionBowlBracket&TankAssemblyandsecurewithfixings(orusemechanicaljoint coupler provided this method meets withlocalcoderequirements).Adddimen-sions to diagram as shown.
7. Slide the Waste Pipe up so the centrelinemarkedonthebodyissetatthecorrectspacingfromtheflushpipeDatum A.
8. SecuretheWastePipepositionbyfirmlypushingtheWastePipeClipsoutwards to latch on to the threaded rods.
INVISI™
SERIES II
Installing the Tank - 237 061
Induct Access
Caroma Invisi II Integrated Wall Hung Bowl Bracket
Finished Floor Level
15.75" - 16.5"(400mm - 420mm)
Datum A
Access box convertedto top (refer to page 11)
Accurate positioning of the soil pipe relative to studwork is essential
WP support& flange nut
assembly, use as required
6.7" (170mm) Max. from finished wall with the waste pipe provided with this pack
5.3" (135mm) Max. with Supplied flush pipeEnsure at least 300mmclearance above top oftank for service access
Height to centre of the
selected bowl's waste outlet
Centre line buttons(standard mounting)
1.8" (45mm) – Water supply connection
22.9" (582mm) Suppliedto centre of inlet
(adjustable from 16.2" - 22.9"or 412mm - 582mm)
Height to centre of the
selected bowl's inlet
Waste Pipe Adjustment
Allows for the 4" (100mm) soil pipe being set back from the wall face up to 1" (25mm).
12
3
8
Refertopages6to7forinstallationprocedure.
NOTE: For Induct Structural Wall installations,theInvisiIItankpack237060inconjunctionwiththeD788SanifixBoltThroughWallBowlBracket(CodeNo.687788)isrecommended,as pictured adjacent.
INVISI™
SERIES IIINVISI™
SERIES II
Installing the Tank - 237 061
Where removal of the tank may be required.
Where adjustment of the tank height is required.
Installing the Tank - 237 061
Induct Access
Caroma Invisi II Integrated Wall Hung Bowl Bracket
Finished Floor Level
15.75" - 16.5"(400mm - 420mm)
Datum A
Access box convertedto top (refer to page 11)
Accurate positioning of the soil pipe relative to studwork is essential
WP support& flange nut
assembly, use as required
6.7" (170mm) Max. from finished wall with the waste pipe provided with this pack
5.3" (135mm) Max. with Supplied flush pipeEnsure at least 300mmclearance above top oftank for service access
Height to centre of the
selected bowl's waste outlet
Centre line buttons(standard mounting)
1.8" (45mm) – Water supply connection
22.9" (582mm) Suppliedto centre of inlet
(adjustable from 16.2" - 22.9"or 412mm - 582mm)
Height to centre of the
selected bowl's inlet
Waste Pipe Adjustment
Allows for the 4" (100mm) soil pipe being set back from the wall face up to 1" (25mm).
12
3
Installing the Tank - 237 061
Where removal of the tank may be required.
Where adjustment of the tank height is required.
9
Locator
Remove tank from Bowl Bracket using ascrewdrivertolevertheplastictaboutoftheholeintheMetalArm,bothsides.
IftheHeightofthetankistobelowered,cut the Flush Pipe and chamfer the inside edge.
Cut the Metal Arms on the Bowl Bracket aslowaspossible.
Lubricate‘O’Ringontanktailusingsoapywater&slideFlushPipeon.
Ensure the Flush Pipe is correctly positioned on the Bowl Bracket.
Continue with installation.
Metal Arm
INVISI™
SERIES II
Installing the Tank - 237 062
Under Counter Access
Counter Top
Basin
Centre Line Buttons(standard mounting)
The Bracket system is suitable for installation only where non compressible wall materials are used.
Accurate positioning of the soil pipe relative to studwork is essential.
To achieve a minimum under counter cavity of 3.5" (90mm)the soil pipe must be accurately centred.
Finished Floor Level
Height to centre of the
selected bowl's waste outlet
Datum A
22.9" (582mm) Supplied
to centre of inlet (adjustable from
16.2"-22.9" (412-582mm))
Height to centre of the
selected bowl's inlet
33.5" (850mm) Min.
2.2" (55mm) Min.- to undersideof counter top
Finished wall
Top Mount Button Panel & Access
Front Mount Button Panel & Access
1.8" (45mm) Max.from top of bench to topof tank for Top Mount Button Installation
WP Support & Flange NutAssembly, use as required (Refer to instruction supplied separately).
Access box convertedto top (refer to page 12)
0.2" (5mm) Min.1.8" (45mm) Max.
Wall Thickness
15.75" - 16.5"(400mm - 420mm)
1.8" (45mm) – Water Supply Connection
3.5" (90mm) Min. CavityFront Mount Button Installation3.9" (100mm) Min. CavityTop Mount Button Installation
Refertopages6to7forinstallationprocedure.
6¼
8¼
Accessboxconvertedtotop(refertopage11)
TheBracketsystemissuitableforinstallationonlywherenon-compressiblewall materials are used.
10
INVISI™
SERIES IIINVISI™
SERIES II
NOTE: Recommended for ADA installationswherebuttonsarewantedontheaccessiblesideofthebowl.
Access Panel Variations
1 2 3
Remote Mounting Box Kit - 237 006
11
Remote Mounting Box Kit - 237 006
Kit Includes• RemoteMountingBox• 2x4mPneumaticTubes• ElevatedFlushPipeParts
The Remote Mounting Box has beenspecificallydesignedinconjunction with and to facilitate theinstallationofbuttonpanelsetsin remote Invisi II installations.
Remote Mounting Box
0.2"or5mmmin.to1.8"or45mmmax.
Wall lining thickness
Remote Installation
For installation with buttonpanelsets
SlidetheTopPanelbackandoffthelid.(Thispanelwillnolongerberequired).There are clips at each end so the Top Panelshouldbecarefullyleveredorflexedtoclearbothclips.
Slide the Access Box up and off the lid. There are clips at each end so the Top Panelshouldbecarefullyleveredorflexedtoclearbothclips.
Find the Front Panel supplied loose in the pack (This panel is slightly larger than the TopPanel).SlidetheFrontPanelontothelid ensuring it locks into position.
Slide the Access Box onto the lid ensuring theoverhangtabistotherearofthetankand it locks into position.
The Panel and Access Box should lock together neatly as shown.
Access Box with Dust Cover
“click”
“click”
Front Cover (suppliedloose)
Top Cover
The Tank is supplied standard with Front Access. For conversion from Front to Top Access follow this procedure.
clips
Clips
INVISI™
SERIES II
1 2
1 2 3
Preparation for Fitout
OR
1 2 3
OR
OR
1 2 3
OR
1 2
Cement or fibro sheet Plywood Tile
12
PneumaticTubeConnections
Direct Panel Mounting
Remote Panel Mounting
Remote Button Mounting
Options for Finishing Around the Flush Pipe
Bowl Bracket
EnsuretheWallHungBowlMountingBolts,FlushPipeandWastePipeareallsettothecorrectheightandspacingtosuittheselectedbowl.Whenfinishingthewallcladandtilerightuptotheedgeoftheseparts.
TheCaromaCubeandWalvitaretheonlybowlscurrentlyapprovedtobeusedwiththeInvisibracket
Attachthetubestothetankasshownabove.BreakouttabintheTopPanelorDustCoverPaneltoallowtheTubestoprotrudeandclipbackintoposition.FeedPneumaticTubesthroughtheframeworkandoutthroughtheDrilledHoles.Applytapeoverendoftubestopreventanydirtfromgettinginsideandtuckneatlybackinsideholes.
Attachthetubestothetankasshownabove.BreakouttabintheTopPanelorDustCoverPaneltoallowtheTubestoprotrudeandclipbackintoposition.Feedthe4mlengthsofPneumaticTubethroughtheframe-workandoutthroughtheMountingBox.ApplytapeoverendoftubestopreventanydirtfromgettinginsideandtuckneatlybackinsidetheMountingBox.Whenfinishingthewallcladandtilerightuptotheedgeof the Access Window and or Remote Mounting Box.
CutPneumaticTubeinhalfsoyouhave2x9.8"(0.25m)lengths(ensureastraightcleancuttotube).Attachthetubestothetankasshownabove.TuckneatlybackinsidetheAccessWindowandclipthedustcoverpanelbackintoposition.Whenfinishingthewall,cladandtilerightuptotheedgeoftheAccessWindow.
Firmlyconnectthepneumatictubeintothehalfandfullflushpositions.Eachtubeshouldbeinsertedapprox.0.6"(16mm)untilithitsastop.NOTE:• 4.8/3LTanksaresuppliedwith19.7"(0.5m)lengthpneumatictube.
• RemoteMountingBoxKitissuppliedwith2x4mlengthsofpneumatictube.
• 4mlengthsofpneumatictubecanbepurchasedseparately.PartNo.237702.
Forinstructionalvideos,pleasevisitwww.caromausa.com
INVISI™
SERIES IIINVISI™
SERIES IIRemoving Internal Components through Access Window
11 - Pre Installation 1- With Button Panel 1- With Blank Access Panel
2 3 4
5 6 7
13
Dust Cover
“click”
“click”
InletValveAssembly
“squeeze”
Bridge Assembly
Outlet Valve
FlexibleHose
Ball Valve Inlet Valve
Face Plate
PanelAssembly
Face Plate
PanelAssembly
Blank Access Panel
Full Flush
DisconnectFlexibleHosefromtheInletValve and the Ball Valve.
LifttabandslidetheInletValveBrackettothe left.
RemovetheBridgeAssemblybysqueezingtabsfrontandbacktodisengagefromlockingtabsinsidethetank.
Lift the Outlet Valve to disengage from guideribsinthebaseofthetankandlayover on its side.
Rotate and remove the Inlet Valve. LifttheOutletValvefromthebaseofthetank,rollforwardsandrotatesothebuttonendcomesoutfirst.NOTE:Reverseproceduretoreassemble.
INVISI™
SERIES II
Servicing - Outlet Valve
1 2 3
14
Wash seal to remove any dirt and inspect for damage. If necessary remove seal andreplace(SparePartKit237070).
237070S
Ensure water is turned off and remove Outlet Valve from tank as per the instructions on page 13.
Re-assemblecompleteOutletValveandrefitintotank.Turnwaterbackon,waitfortanktofillandtestbothbuttonstoensurethey activate the outlet valve.
Seal
• Servicingisonlyrequiredininstanceswhereoutletvalveoperationisfoundtobefaulty.
Servicing Requirements
• IfOutletValveleaks►Inspectsealfordamageandreplaceifnecessary.
• Ifshortflushing►Checkpneumatictubesarepushedintothebridgeandbuttons
• Ifanyotherissuesarise►ConsultaplumberorCaromaAfterSalesService.
TroubleshootingGuide
•CaromaInvisiIIOutletValvecompatibleSparePartKitsare:
237 072 Containing - 1 x Complete 4.8/3L Replacement Outlet Valve
237 070 Containing - Diaphragm Seal (10Pack)
237 070S for Single Diaphram Seal
Refer to Maintenance & Spare Parts Instructions
Spare Parts Information
Maintenance&SparePartsInstructions
INVISI™
SERIES IIINVISI™
SERIES II
Servicing - Inlet Valve
Helplines 53 4
1 2a 2b
A
AD
CB
A
C
B
Maintenance&SparePartsInstructions
Wash seal to remove any dirt and inspect for damage.
RemovesealfromCapAssembly. Replacesealontocapassembly.Ifnecessaryreplacecap&Seal(SparePartKit687049).Push&rotatecounter-clockwisetore-attachcapassembly,re-clipAdjustmentScrewandre-fitintotank.
AdjustmentScrew
To clean and inspect seal:UncliptheAdjustmentScrew,rotateclockwise&pulltoremovecapassembly.
To replace complete Inlet Valve:Rotatenutclockwise&pulltodisconnectit from the Bracket.
Cap Assembly
Bracket
Inlet Valve
15
• InletValveisslowtofillORfailstoopen►Ensuretapisopen.
• InletValvefailstoclose►Clean&inspectsealasdescribedabove,replaceCapAssembly &Sealifdamaged.
• Ifanyotherissuesarise►ConsultaplumberorCaromaAfterSalesService.
• InletValveSealmayrequireperiodiccleaning(dependantonwaterquality). Procedureasdefinedbelow.
Servicing Requirements
TroubleshootingGuide
• CaromaInvisiIIInletValvecompatibleSparePartKitsare:
687 171 Containing - 1 x Complete Unifill Inlet Valve - withbayonetconnection
687 049 Containing - 1 x Cap Assembly - 1 x Seal with Lever
687 040D Containing - Seal only
Refer to Maintenance & Spare Parts Instructions
Spare Parts Information
687049CapAssembly
687040DSeal
Ensure water is turned off and remove Inlet Valve from tank as per the instructions on page 13.
687040DSeal
Important Notices
Helplines
16
Important Notices
Recommended Water Supply Pressure
Water Supply pressure minimum 4.35psi/30 kPa - Maximum 145psi/1000 kPa
Caroma / SSI 1-800-460-70198395RiverbendCourt www.caromausa.comBurnaby,BritishColumbia www.sustainablesolutions.comCanadaV3N5E7
LeafletNo. 237560~A