series ii walvit + cube - plumbing mall.com · 2020. 12. 21. · • 3.5"/90mm min. inwall...

16
SERIES II WALVIT + CUBE 1.28/0.8 Gal (4.8/3 Litre) Concealed Tank 237061 + 237062

Upload: others

Post on 20-Aug-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES II

1.28/0.8 Gal (4.8/3 Litre)concealed cistern237060, 237061 & 237062

SERIES II WALVIT + CUBE

1.28/0.8 Gal (4.8/3 Litre)Concealed Tank237061 + 237062

Page 2: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES II

Contents

2

5 Step Easy Install ................................................................................................. 3

Installation Requirements ...................................................................................... 3

Tank Service Access Options ................................................................................ 4

Button Service Access Options ............................................................................. 5

Installing the Tank - 237 061 Inwall Access .................................................................................................. 6

Induct Access ................................................................................................... 8

Where adjustment of the tank height is required ............................................. 9

Installing the Tank - 237 062 Under Counter Access .................................................................................. 10

Optional Remote Mounting Box Kit - 237 006 .................................................... 11

Access Panel Variations ...................................................................................... 11

Preparation for Fitout ........................................................................................... 12

Removing Internal Components through Access Window................................... 13

Servicing - Outlet Valve ....................................................................................... 14

Servicing - Inlet Valve .......................................................................................... 15

Important Notices ................................................................................................ 16

Helplines .............................................................................................................. 16

Page 3: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES IIINVISI™

SERIES II

5 Step Easy Install

Installation Requirements

1 2 3 4 5

3

237 060 - Invisi II 4.8/3L Dual Flush Tank

CONTENTS

• InvisiII-4.8/3LConcealedTank•MountingBrackets• TallFlushPipe• 19.7"/0.5mofPneumaticTube• TankFixingPack• BrassWaterSupplyFitting

237 061 - Invisi II 4.8/3L Dual Flush Tank - with Standard Wall Hung Bowl Bracket

CONTENTS

• InvisiII-4.8/3LConcealedTank•MountingBrackets• Inwall,WallHungBowlBracket• TallFlushPipe• 19.7"/0.5mofPneumaticTube• 3.5"/90mmWastePipe• BowlBracketFixingPack• BrassWaterSupplyFitting

REQUIREMENTS

• 3.5"/90mmMin.InwallCavityDepth• 15.75"/400mmMin.-16.5”/420mmMaxCavityWidth(e.g.betweenstuds)

• 15/16"-14NS-1WaterConnectionsuppliedwithadaptorto½"Coppersolderor FIP

REQUIREMENTS

• 3.5"/90mmMin.InwallCavityDepth• 15.75"/400mmMin.-16.5"/420mmMaxCavityWidth(e.g.betweenstuds)

• 15/16"-14NS-1WaterConnectionsuppliedwithadaptorto½"Coppersolderor FIP

237 062 - Invisi II 4.8/3L Dual Flush Tank - with Under Counter Wall Hung Bowl Bracket

CONTENTS

• InvisiII-4.8/3LConcealedTank•MountingBrackets• UnderCounter,WallHungBowl

Bracket• ShortFlushPipe• 19.7"/0.5mofPneumaticTube• 3.5"/90mmWastePipe• BowlBracketFixingPack• BrassWaterSupplyFitting

REQUIREMENTS

• 33.5"/850mmMin.Heighttoundercounter• 3.5"/90mmMin.(FrontMountButtonPanel)3.9"/100mmMin.(TopMountButtonPanel)InwallCavityDepth

• 15.75"/400mmMin-16.5"/420mmMaxCavityWidth(e.g.betweenstuds)

• 15/16"-14NS-1WaterConnectionsuppliedwithadaptorto½"Coppersolderor FIP

NOTE:Non-compressiblematerialmustbeinstalledbehindthebowl.

Check Installation

Requirements

Select Tank Service

Access Options

Select Button Service

Access Options

Installing the Tank

Preparation for Fitout

Page 4: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES II

Tank Service Access Options

4

Inwall Access

Thisallowsaccesstotankinternalsthroughthebuttonpanelwindow.Standardinstallationrequiresnochangetoproductconfiguration.

AnoptionalRemoteMountingBoxKit(refertopage11)isrequiredifusingRemoteButtonPaneland/orextendingtheflushpipe.

Induct Access

This allows access to the whole tank. Standard installation will requireRemoteMountingBoxKit(refertopage11)forusewithRemote Button Panel.

Under Counter Access

Thisallowsaccesstotankinternalsthroughthebuttonpanelwindow.Standardinstallationrequiresnochangetoproductconfiguration.

OptionalTopAccesswillrequiretheaccesspaneltobeconverted(refertopage11).

Page 5: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES IIINVISI™

SERIES II

Button Service Access Options

5

Direct Panel Mounting - Front

Thisissuitableforusewithanyofthebuttonpanelkits.

Requiresa0.2"(5mm)minimum-1.8"(45mm)maximumwallthickness.

Access to the tank internals is provided through the panel window.

Remote Panel Mounting

Thisissuitableforusewithanyofthebuttonpanelkits.

Requiresa0.2"(5mm)minimum-1.8"(45mm)maximumwallthickness.

A Blank Access Panel is required for inwall access to tank internals.

Remote Button Mounting

Accesstotherearofthebuttonsmustbeprovidedforservicing.

Suitableformountingthroughpanelsupto2.2"(55mm)thick.

A Blank Access Panel is required for inwall access to tank internals.

Care Button Panel

ACareButtonPanelisavailableforuse in ADA applications.

Direct Panel Mounting - Top

Thisissuitableforusewithanyofthebuttonpanelkits.

Requiresa0.2"(5mm)minimum-1.8"(45mm)maximumwallthickness.

Access to the tank internals is provided through the panel window.

Page 6: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES II

Installing the Tank - 237 061

Inwall Access

Caroma Invisi II IntegratedWall Hung Bowl Bracket

Accurate positioning of the soil pipe relative to studwork is essential.

3.5" (90mm) Min.Cavity Depth

Finished Floor Level

Soil Pipe

Waste Pipe

6 ¼"

8 ¼"

15.75" - 16.5"(400mm - 420mm)

1.8" (45mm) – Water Supply Connection

Datum A

Datum B Front edge of3.5" (90mm) Stud

0.2" (5mm) Min.1.8"(45mm) Max.

Wall Thickness

Centre Line Buttons(standard mounting)

Stud Wall Installation(for non-structural floor)

To achieve a minimum wall cavity of 3.5" or 90mm the soil pipe must be accurately centred.

22.9" (582mm) Suppliedto centre of inlet

(adjustable from 16.2" - 22.9"or 412mm - 582mm)

Height to centre of the selected bowl’s inlet

Hole #1

Hole #3

Hole #1

Height to centre of the selected bowl's waste outlet to achieve 17”

ADA seat height

NOTE: Non compressable material must be used behind the bowl, from Datum A to floor

Use Hole #1 for Walvit Bowl 7 7/8 CLUse Hole #3 for Cube Bowl 7 1/8 CL

See page 8 for detailed rough-in instructions

TheCaromaCubeandWalvitaretheonlybowlscurrentlyapprovedtobeusedwiththeInvisibracket.

6

Page 7: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES IIINVISI™

SERIES II

Installing the Tank - 237 061

Inwall Access - continued

1

2

3

“click”“click”

Dust Cover

ON OFF

4

Datum A

123

Water Supply Connection

Installing the Tank - 237 061

Inwall Access

Caroma Invisi II IntegratedWall Hung Bowl Bracket

Accurate positioning of the soil pipe relative to studwork is essential.

3.5" (90mm) Min.Cavity Depth

Finished Floor Level

Soil Pipe

Waste Pipe

6 ¼"

8 ¼"

15.75" - 16.5"(400mm - 420mm)

1.8" (45mm) – Water Supply Connection

Datum A

Datum B Front edge of3.5" (90mm) Stud

0.2" (5mm) Min.1.8"(45mm) Max.

Wall Thickness

Centre Line Buttons(standard mounting)

Stud Wall Installation(for non-structural floor)

To achieve a minimum wall cavity of 3.5" or 90mm the soil pipe must be accurately centred.

22.9" (582mm) Suppliedto centre of inlet

(adjustable from 16.2" - 22.9"or 412mm - 582mm)

Height to centre of the selected bowl’s inlet

Hole #1

Hole #3

Hole #1

Height to centre of the selected bowl's waste outlet to achieve 17”

ADA seat height

NOTE: Non compressable material must be used behind the bowl, from Datum A to floor

Use Hole #1 for Walvit Bowl 7 7/8 CLUse Hole #3 for Cube Bowl 7 1/8 CL

7

1. Checkthatthe4"(100mm)soilpipeiscentredbetweenthestuds-checkthereis15.75"-16.5"(400-420mm)betweenthestuds(17.7"or450mm nominal to studcentres).

2. Calculatethefinishedfloorheight(allowingforfloorgradingsandtilethick-ness,etc.)andaddthistotheknownheightoftheselectedbowl'sinlet.Markthis resulting height on the stud - This is your “Datum A” and flush pipe centre line.

NOTE: This is your “Datum A” and flush pipe centre line. From finished floor to centre of waste pipe is 8 ¼". From finished floor to centre of flushpipe is 14 ½" to achieve 17" seat height. See diagram on page 6.

3. Measure and ensure the Flush Pipe Centre Line which is marked on the Bowl Bracket is at the correct height. This should match the Datum A previously established.Useanallenkeytoadjust.Ensureboltsaretightenedaftersetting.

4. Placethebowlbracket&tankas-semblyinpositionandmarkoutall4boltlocationsinthebracketfeet.

NOTE: The front face of the bowl bracket should be flush with the front face of the studs (“Datum B”) & the 4" (100mm) soil pipe should be centred in both the wall cavity and between studs as well as being cut flush with the floor. (Depending on code approv-als in your area: if it is 4" then the insert fitting is used and it is cut flush. If the connection is 3" it is below the floor and the supplied waste pipe is long enough to go through the floor).

9. Screw in threaded rods for mounting the bowlandlockinpositionwithnutsagainstthe Front Plate. Three hole spacings are provided: 1-7.9”or200mm.UseHole#1forWalvitBowls.2-11”or280mm.3-7”or180mm.UseHole#3forCubeBowls.

10. Screw the tank in place using at least 1 of the 2 holes provided in the top of each mountingbracket.Makesurethewatercon-nectionfittingisonthelefthandsideoftankandtankisflushwithwall.

11. Connect the water supply with 15/16 14NS-1fittingandadaptorfittingfor1/2"bothsupplied.

12. RemoveDustCover,turnIsolatingTapON,filltank&setwaterlevelusingAdjust-ing Screw on the inlet valve.

13. Check tank and all joints for leaks.

14. Turn Isolating Tap OFF. Continue with Preparation for Fitout on page 12.

5. MoveBowlBracket&TankAssemblyout of its installation position and drill the 4 holesinthefloorasmarked.Carriermustbeanchoredsecurelytothefloor.

For Structural Flooring (concrete)Drill Ø0.5"or12mmholeforusewithM12TRU Bolts supplied in pack.

For Non Structural Flooring (wood)Drilltosuitfixingsused(fixingsnotsup-plied).Theverticalarmsofthebowlbracketmustalsobeboltedtosidestuds.

6. LubricatetheWastePipewithsoapandwater and push into the soil pipe. Carefully repositionBowlBracket&TankAssemblyandsecurewithfixings(orusemechanicaljoint coupler provided this method meets withlocalcoderequirements).Adddimen-sions to diagram as shown.

7. Slide the Waste Pipe up so the centrelinemarkedonthebodyissetatthecorrectspacingfromtheflushpipeDatum A.

8. SecuretheWastePipepositionbyfirmlypushingtheWastePipeClipsoutwards to latch on to the threaded rods.

Page 8: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES II

Installing the Tank - 237 061

Induct Access

Caroma Invisi II Integrated Wall Hung Bowl Bracket

Finished Floor Level

15.75" - 16.5"(400mm - 420mm)

Datum A

Access box convertedto top (refer to page 11)

Accurate positioning of the soil pipe relative to studwork is essential

WP support& flange nut

assembly, use as required

6.7" (170mm) Max. from finished wall with the waste pipe provided with this pack

5.3" (135mm) Max. with Supplied flush pipeEnsure at least 300mmclearance above top oftank for service access

Height to centre of the

selected bowl's waste outlet

Centre line buttons(standard mounting)

1.8" (45mm) – Water supply connection

22.9" (582mm) Suppliedto centre of inlet

(adjustable from 16.2" - 22.9"or 412mm - 582mm)

Height to centre of the

selected bowl's inlet

Waste Pipe Adjustment

Allows for the 4" (100mm) soil pipe being set back from the wall face up to 1" (25mm).

12

3

8

Refertopages6to7forinstallationprocedure.

NOTE: For Induct Structural Wall installations,theInvisiIItankpack237060inconjunctionwiththeD788SanifixBoltThroughWallBowlBracket(CodeNo.687788)isrecommended,as pictured adjacent.

Page 9: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES IIINVISI™

SERIES II

Installing the Tank - 237 061

Where removal of the tank may be required.

Where adjustment of the tank height is required.

Installing the Tank - 237 061

Induct Access

Caroma Invisi II Integrated Wall Hung Bowl Bracket

Finished Floor Level

15.75" - 16.5"(400mm - 420mm)

Datum A

Access box convertedto top (refer to page 11)

Accurate positioning of the soil pipe relative to studwork is essential

WP support& flange nut

assembly, use as required

6.7" (170mm) Max. from finished wall with the waste pipe provided with this pack

5.3" (135mm) Max. with Supplied flush pipeEnsure at least 300mmclearance above top oftank for service access

Height to centre of the

selected bowl's waste outlet

Centre line buttons(standard mounting)

1.8" (45mm) – Water supply connection

22.9" (582mm) Suppliedto centre of inlet

(adjustable from 16.2" - 22.9"or 412mm - 582mm)

Height to centre of the

selected bowl's inlet

Waste Pipe Adjustment

Allows for the 4" (100mm) soil pipe being set back from the wall face up to 1" (25mm).

12

3

Installing the Tank - 237 061

Where removal of the tank may be required.

Where adjustment of the tank height is required.

9

Locator

Remove tank from Bowl Bracket using ascrewdrivertolevertheplastictaboutoftheholeintheMetalArm,bothsides.

IftheHeightofthetankistobelowered,cut the Flush Pipe and chamfer the inside edge.

Cut the Metal Arms on the Bowl Bracket aslowaspossible.

Lubricate‘O’Ringontanktailusingsoapywater&slideFlushPipeon.

Ensure the Flush Pipe is correctly positioned on the Bowl Bracket.

Continue with installation.

Metal Arm

Page 10: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES II

Installing the Tank - 237 062

Under Counter Access

Counter Top

Basin

Centre Line Buttons(standard mounting)

The Bracket system is suitable for installation only where non compressible wall materials are used.

Accurate positioning of the soil pipe relative to studwork is essential.

To achieve a minimum under counter cavity of 3.5" (90mm)the soil pipe must be accurately centred.

Finished Floor Level

Height to centre of the

selected bowl's waste outlet

Datum A

22.9" (582mm) Supplied

to centre of inlet (adjustable from

16.2"-22.9" (412-582mm))

Height to centre of the

selected bowl's inlet

33.5" (850mm) Min.

2.2" (55mm) Min.- to undersideof counter top

Finished wall

Top Mount Button Panel & Access

Front Mount Button Panel & Access

1.8" (45mm) Max.from top of bench to topof tank for Top Mount Button Installation

WP Support & Flange NutAssembly, use as required (Refer to instruction supplied separately).

Access box convertedto top (refer to page 12)

0.2" (5mm) Min.1.8" (45mm) Max.

Wall Thickness

15.75" - 16.5"(400mm - 420mm)

1.8" (45mm) – Water Supply Connection

3.5" (90mm) Min. CavityFront Mount Button Installation3.9" (100mm) Min. CavityTop Mount Button Installation

Refertopages6to7forinstallationprocedure.

Accessboxconvertedtotop(refertopage11)

TheBracketsystemissuitableforinstallationonlywherenon-compressiblewall materials are used.

10

Page 11: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES IIINVISI™

SERIES II

NOTE: Recommended for ADA installationswherebuttonsarewantedontheaccessiblesideofthebowl.

Access Panel Variations

1 2 3

Remote Mounting Box Kit - 237 006

11

Remote Mounting Box Kit - 237 006

Kit Includes• RemoteMountingBox• 2x4mPneumaticTubes• ElevatedFlushPipeParts

The Remote Mounting Box has beenspecificallydesignedinconjunction with and to facilitate theinstallationofbuttonpanelsetsin remote Invisi II installations.

Remote Mounting Box

0.2"or5mmmin.to1.8"or45mmmax.

Wall lining thickness

Remote Installation

For installation with buttonpanelsets

SlidetheTopPanelbackandoffthelid.(Thispanelwillnolongerberequired).There are clips at each end so the Top Panelshouldbecarefullyleveredorflexedtoclearbothclips.

Slide the Access Box up and off the lid. There are clips at each end so the Top Panelshouldbecarefullyleveredorflexedtoclearbothclips.

Find the Front Panel supplied loose in the pack (This panel is slightly larger than the TopPanel).SlidetheFrontPanelontothelid ensuring it locks into position.

Slide the Access Box onto the lid ensuring theoverhangtabistotherearofthetankand it locks into position.

The Panel and Access Box should lock together neatly as shown.

Access Box with Dust Cover

“click”

“click”

Front Cover (suppliedloose)

Top Cover

The Tank is supplied standard with Front Access. For conversion from Front to Top Access follow this procedure.

clips

Clips

Page 12: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES II

1 2

1 2 3

Preparation for Fitout

OR

1 2 3

OR

OR

1 2 3

OR

1 2

Cement or fibro sheet Plywood Tile

12

PneumaticTubeConnections

Direct Panel Mounting

Remote Panel Mounting

Remote Button Mounting

Options for Finishing Around the Flush Pipe

Bowl Bracket

EnsuretheWallHungBowlMountingBolts,FlushPipeandWastePipeareallsettothecorrectheightandspacingtosuittheselectedbowl.Whenfinishingthewallcladandtilerightuptotheedgeoftheseparts.

TheCaromaCubeandWalvitaretheonlybowlscurrentlyapprovedtobeusedwiththeInvisibracket

Attachthetubestothetankasshownabove.BreakouttabintheTopPanelorDustCoverPaneltoallowtheTubestoprotrudeandclipbackintoposition.FeedPneumaticTubesthroughtheframeworkandoutthroughtheDrilledHoles.Applytapeoverendoftubestopreventanydirtfromgettinginsideandtuckneatlybackinsideholes.

Attachthetubestothetankasshownabove.BreakouttabintheTopPanelorDustCoverPaneltoallowtheTubestoprotrudeandclipbackintoposition.Feedthe4mlengthsofPneumaticTubethroughtheframe-workandoutthroughtheMountingBox.ApplytapeoverendoftubestopreventanydirtfromgettinginsideandtuckneatlybackinsidetheMountingBox.Whenfinishingthewallcladandtilerightuptotheedgeof the Access Window and or Remote Mounting Box.

CutPneumaticTubeinhalfsoyouhave2x9.8"(0.25m)lengths(ensureastraightcleancuttotube).Attachthetubestothetankasshownabove.TuckneatlybackinsidetheAccessWindowandclipthedustcoverpanelbackintoposition.Whenfinishingthewall,cladandtilerightuptotheedgeoftheAccessWindow.

Firmlyconnectthepneumatictubeintothehalfandfullflushpositions.Eachtubeshouldbeinsertedapprox.0.6"(16mm)untilithitsastop.NOTE:• 4.8/3LTanksaresuppliedwith19.7"(0.5m)lengthpneumatictube.

• RemoteMountingBoxKitissuppliedwith2x4mlengthsofpneumatictube.

• 4mlengthsofpneumatictubecanbepurchasedseparately.PartNo.237702.

Forinstructionalvideos,pleasevisitwww.caromausa.com

Page 13: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES IIINVISI™

SERIES IIRemoving Internal Components through Access Window

11 - Pre Installation 1- With Button Panel 1- With Blank Access Panel

2 3 4

5 6 7

13

Dust Cover

“click”

“click”

InletValveAssembly

“squeeze”

Bridge Assembly

Outlet Valve

FlexibleHose

Ball Valve Inlet Valve

Face Plate

PanelAssembly

Face Plate

PanelAssembly

Blank Access Panel

Full Flush

DisconnectFlexibleHosefromtheInletValve and the Ball Valve.

LifttabandslidetheInletValveBrackettothe left.

RemovetheBridgeAssemblybysqueezingtabsfrontandbacktodisengagefromlockingtabsinsidethetank.

Lift the Outlet Valve to disengage from guideribsinthebaseofthetankandlayover on its side.

Rotate and remove the Inlet Valve. LifttheOutletValvefromthebaseofthetank,rollforwardsandrotatesothebuttonendcomesoutfirst.NOTE:Reverseproceduretoreassemble.

Page 14: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES II

Servicing - Outlet Valve

1 2 3

14

Wash seal to remove any dirt and inspect for damage. If necessary remove seal andreplace(SparePartKit237070).

237070S

Ensure water is turned off and remove Outlet Valve from tank as per the instructions on page 13.

Re-assemblecompleteOutletValveandrefitintotank.Turnwaterbackon,waitfortanktofillandtestbothbuttonstoensurethey activate the outlet valve.

Seal

• Servicingisonlyrequiredininstanceswhereoutletvalveoperationisfoundtobefaulty.

Servicing Requirements

• IfOutletValveleaks►Inspectsealfordamageandreplaceifnecessary.

• Ifshortflushing►Checkpneumatictubesarepushedintothebridgeandbuttons

• Ifanyotherissuesarise►ConsultaplumberorCaromaAfterSalesService.

TroubleshootingGuide

•CaromaInvisiIIOutletValvecompatibleSparePartKitsare:

237 072 Containing - 1 x Complete 4.8/3L Replacement Outlet Valve

237 070 Containing - Diaphragm Seal (10Pack)

237 070S for Single Diaphram Seal

Refer to Maintenance & Spare Parts Instructions

Spare Parts Information

Maintenance&SparePartsInstructions

Page 15: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

INVISI™

SERIES IIINVISI™

SERIES II

Servicing - Inlet Valve

Helplines 53 4

1 2a 2b

A

AD

CB

A

C

B

Maintenance&SparePartsInstructions

Wash seal to remove any dirt and inspect for damage.

RemovesealfromCapAssembly. Replacesealontocapassembly.Ifnecessaryreplacecap&Seal(SparePartKit687049).Push&rotatecounter-clockwisetore-attachcapassembly,re-clipAdjustmentScrewandre-fitintotank.

AdjustmentScrew

To clean and inspect seal:UncliptheAdjustmentScrew,rotateclockwise&pulltoremovecapassembly.

To replace complete Inlet Valve:Rotatenutclockwise&pulltodisconnectit from the Bracket.

Cap Assembly

Bracket

Inlet Valve

15

• InletValveisslowtofillORfailstoopen►Ensuretapisopen.

• InletValvefailstoclose►Clean&inspectsealasdescribedabove,replaceCapAssembly &Sealifdamaged.

• Ifanyotherissuesarise►ConsultaplumberorCaromaAfterSalesService.

• InletValveSealmayrequireperiodiccleaning(dependantonwaterquality). Procedureasdefinedbelow.

Servicing Requirements

TroubleshootingGuide

• CaromaInvisiIIInletValvecompatibleSparePartKitsare:

687 171 Containing - 1 x Complete Unifill Inlet Valve - withbayonetconnection

687 049 Containing - 1 x Cap Assembly - 1 x Seal with Lever

687 040D Containing - Seal only

Refer to Maintenance & Spare Parts Instructions

Spare Parts Information

687049CapAssembly

687040DSeal

Ensure water is turned off and remove Inlet Valve from tank as per the instructions on page 13.

687040DSeal

Page 16: SERIES II WALVIT + CUBE - Plumbing Mall.com · 2020. 12. 21. · • 3.5"/90mm Min. Inwall Cavity Depth • 15.75"/400mm Min. - 16.5"/420mm Max Cavity Width (e.g. between studs) •

Important Notices

Helplines

16

Important Notices

Recommended Water Supply Pressure

Water Supply pressure minimum 4.35psi/30 kPa - Maximum 145psi/1000 kPa

Caroma / SSI 1-800-460-70198395RiverbendCourt www.caromausa.comBurnaby,BritishColumbia www.sustainablesolutions.comCanadaV3N5E7

LeafletNo. 237560~A