series - heatpumps4pools...at low speeds, climexel heat pumps’ cop is improved by 30 to 40 %....
TRANSCRIPT
S E R I E S
P o o l & S p a E q u i p m e n t
SWIMMING POOL HEATING
CLIMEXEL
HEAT/COOL PUMPS
APPRECIATE THE PERFORMANCE...LISTEN TO THE SILENCE...
procopi.com Swimming Pool heating CLIMEXEL 2HEAT/COOL PUMPS
Procopi, a leading French manufacturer of pool and spa equipment, has joined forces with Mitsubishi Electric, a world leader in the field of climate control.
An entirely new range of swimming pool heat pumps was created that exploit a major innovation in the swimming pool market, Power Inverter® technology, to achieve exceptional performance levels, both in terms of acoustic and thermal power.
P R O C O P I ’ S I N D U S T R I A L S T R E N G T H
* M.P.I. : Mitsubishi Power Inverter** M.Z.I. : Mitsubishi Zubadan Inverter
S E R I E S
P o o l & S p a E q u i p m e n t
Swimming Pool heating CLIMEXEL 3HEAT/COOL PUMPS
P o o l & S p a E q u i p m e n t
Climexel heat pumps are designed to automatically adapt to your pool’s operating conditions. They are extremely easy to use.
T O TA L A U T O M AT I O N
The Climexel / Mitsubishi Power Inverter® (Climexel M.P.I.*) and Zubadan Inverter® (Climexel M.Z.I.**) range features a wide variety of power outputs, between 8 and 38 kW, to suit every type of pool.
Whatever the size of your pool, whatever your heating needs, the Climexel range is sure to include the perfect heat pump for you.
C O M P R E H E N S I V E R A N G E
P R O C O P I . C O Mprocopi.com Swimming Pool heating CLIMEXEL 4HEAT/COOL PUMPS
A heat pump exploits a thermodynamic principle to capture heat calories from ambient air and then transfer them to swimming pool water. For every kilowatt of electricity it consumes, a Climexel heat pump delivers up to 7.6 kW of heating power, fulfilling the requirement for an ‘A’ rating according to the ‘Directive Technique Piscine N°10’ (pool directive pertaining to heating issued by the FPP - French federation of pool professionals ).
This is one of the best yields available on the market.
W H AT I S A H E AT P U M P ?
Climexel heat pumps are fitted with a frequency variator capable of adjusting the compressor and fan speeds. On the contrary to the compressor and fan(s) in conventional On/Off heat pumps that run at a fixed speed (50 Hz), those in the Climexel heat pumps run at variable speeds (11 to 100 Hz), thus allowing the machine to automatically adapt to the heating demand and climatic conditions.
While the outdoor temperature is low, or while the heating demand is high, the Power Inverter® compressor and fan(s) run at high speed, between 50 Hz and 100 Hz).
Inversely, while the heating demand is low, or while the heat pump is running at temperatures around the set point, the Inverter® compressor and fan(s) will run at low speeds (between 11 Hz and 50 Hz).At low speeds, Climexel heat pumps’ COP is improved by 30 to 40 %.
Running at low speeds, the Inverter® compressor and fan(s) are almost noiseless and provide optimal yields. In addition, the service life of the Climexel heat pump compressor, and other components, is extended.
I N V E R T E R P R I N C I P L E
Temperature
Time
Heat pump CLIMEXEL M.P.I.
100%
140%
30%
Initial18°c
Desired24°c
Heat pump operationCLIMEXEL M.P.I.
Temperature
Heat pump operationOn / Off
ONOFF
ONOFF
ONOFF
Time
Heat pump On/Off
100%
0%
Initial18°c
Desired24°c
* Dependant on the model and operating conditions
S E R I E S
P o o l & S p a E q u i p m e n t
Swimming Pool heating CLIMEXEL 5HEAT/COOL PUMPS
Speed Distance Fuel consumption Travel time Consumption for 100 Km
120 Km/h 100 Km 8 litres/100 Km 50 minutes 8 litres
90 Km/h 100 Km 5.6 litres/100 Km 67 minutes 5.6 litres
CASE OF A MOTORISED VEHICLE
As can be seen in the table above, a car travelling at 90 km/h will take 17 minutes longer to travel 100 km than than a car travelling at 120 km/h. On the other hand, fuel consumption at 120 km/h (8 l/100 km) is much higher than it is at 90 km/h (5.6 l/100 km). As a result, although the car travelling at 90 km/h took 17 minutes longer to cover 100 kilometers, it used 2.4 l less fuel.
The table above shows that, to generate the 18 kW required to maintain the pool water temperature, a Climexel heat pump running at a reduced heating power of 9 kW, will run for an hour more than an 18 kW On/Off machine but, due to its particularly high COP, it will only consume 3.39 kW compared to 4.39 kW for the On/Off device.
Power Pool demand COP Run time Consumption for 3 kW
18 kW - ON/OFF 3 kW 4.1 60 minutes 4.39 kW
9 kW - Inverter 3 kW 5.3 120 minutes 3.39 kW
CASE OF A CLIMEXEL HEAT PUMP
While a Climexel heat pump runs at water temperatures hovering around its set point, the power it requires, and hence its electrical consumption, drops. To maintain the water temperature, a Climexel heat pump runs for a longer time than a conventional On/Off heat pump.However, because it runs within ranges where it achieves a superior COP, the final analysis reveals that it consumes less electricity than a conventional heat pump.
The concept behind the savings achieved by a Climexel heat pump is easy to grasp when compared to the case of a motorised vehicle.
A N A L O G Y W I T H A M O T O R I S E D V E H I C L E
P R O C O P I . C O Mprocopi.com Swimming Pool heating CLIMEXEL 6HEAT/COOL PUMPS
HEAT/COOL PUMPS
CLIMEXEL M.Z.I. - AN ALL SEASON HEAT PUMP
S E R I E S
P o o l & S p a E q u i p m e n t
Swimming Pool heating CLIMEXEL 7HEAT/COOL PUMPS
Supplemental heating or oversizing is necessary
A Climexel M.Z.I. heat pump maintains 71% of its heating capacity with outdoor air temperatures as low as -15°C. It is truly an all season machine purpose designed for the heating of covered pools that are used year round and for which it is necessary to maintain a nominal heating power.
OPERATING PRINCIPLE:Climexel M.Z.I. heat pumps compensate extremely low outdoor air temperatures by injecting hot gas, stored in an additional bottle, directly at the compressor.
The injection of a liquid/ gas mixture at the compressor makes it possible to achieve a lower return temperature while maintaining a high COP. This flash injection ensures that the compressor has enough refrigerant fluid to prevent overheating which would automatically cause the compressor to slow down to protect itself.The decrease in mass flow rate entails a corresponding drop in low pressure that is influenced by the outdoor temperature (the lower the outdoor temperature, the lower the low pressure).
E X A M P L E - H E AT I N G D E M A N D F O R A 8 X 4 X 1 . 5 0 M P O O L
in kW
5
10
15
20
25
30
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Heating power of a 14 kW On/Off heat pumpHeating power of a 25 kW On/Off heat pumpHeating demand of a 8x4x1.5 pool (48m2) - European climate
The heating power generated by an On/Off heat pump decreases as the outdoor air temperature falls. The graph below clearly shows that this type of machine provides more and more power as the air temperature increases. Inversely, the pool’s heating demand gradually falls for the same reason. Hence, during the months of June and July, in a European climate, a conventional 25 kW heat pump (at 15°C) can generate up to 27 kW power, even though the pool only needs 8 kW.
On the contrary, a Climexel heat pump adapts its power, its consumption and its noise level to the exact requirements of the pool throughout the various seasons.
NOMINAL POWER (%)
Air temperature On/Off Climexel M.Z.I.
+15° C 100 100
+12° C 91 94
+7° C 79 84
- 7° C 54 81
- 10° C - 77
- 15° C - 71
0 10 20 30 40 60 70 80 90 100 110 120 dB(A)
audabilitythreshold
painthreshold
library
dish washer
heavytraffic
stereo
jackhammer
air planetake off
Climexel M.P.I.heat pumps
conversation1 m away
sound lab
dangerousnoises
fatiguethreshold
quietnoises
50
procopi.com Swimming Pool heating CLIMEXEL 8HEAT/COOL PUMPS
T H E S I L E N C E
The acoustic power of an On/Off heat pump remains constant, even while the machine is running at water temperatures around the set point.
On the contrary, a Climexel heat pump adapts the operating regimes of its compressor and its fan(s) to match the actual heating demand of the pool, notably as the water temperature approaches the set point.
The evaporator in a Climexel heat pump has a very large surface area: air can circulate more freely, more slowly thus reducing whistling. All Climexel heat pumps (except for the M.P.I. 80M, M.P.I. 100M, M.P.I. 160M and M.Z.I. 160M models) are fitted with Mitsubishi Scroll Inverter® compressors, the recognised reference in terms of acoustic performance. Mitsubishi Electric Inverter® compressors are acoustically insulated.
To hear a Climexel heat pump, you really have to listen carefully.
This feature is particularly appreciated in situations where the heat pump must be installed near your residence or that of your neighbours.
In order to appreciate the acoustic performance of Climexel heat pumps, a scale is provided below that allows you to compare the tolerance limits of various devices and everyday events. It may be seen that, even running at 100% capacity, Climexel heat pumps fall well within common, acceptable tolerance limits.
A C O U S T I C C O M F O R T
P R O C O P I . C O M
COP =
S E R I E S
P o o l & S p a E q u i p m e n t
Swimming Pool heating CLIMEXEL 9HEAT/COOL PUMPS
COP
power provided bythe heat pump (%)
Comparison - air temperature 15°C, water temperature 26°C
00
1
3
2
4
5
6
7
25 50 75 100 125
CLIMEXEL M.P.I. heat pump On/Off heat pump
E N E R G Y P E R F O R M A N C E
At full speed (100 Hz), a Climexel heat pump delivers a COP equivalent to that of an On/Off heat pump operating at 50 Hz.However, as the pool water temperature approaches the set point, the frequency of rotation of the Climexel heat pump’s compressor and fan(s) will slow, thus generating a significant increase in COP, while lowering the acoustic power.
E X A M P L E I L L U S T R AT I N G T H E D I F F E R E N C E I N C O P B E T W E E N A C L I M E X E L H E AT P U M P A N D A N O N / O F F H E AT P U M P
Thermal power delivered to the water
Consumed power
CAUTIONThe COP is measured at an air temperature of 15° C and a water temperature of 26° C.
Coefficient Of Performance.
The COP measures the performance of a heat pump in terms of energy
(Extract from DTP N°10 - Pool directive pertaining to heating issued by the French
federation of pool professionals, FFP).
The COP is the ratio between the heating power, delivered as heat to the pool, and the total electrical power consumed by the heat pump.
W H AT I S T H E P U R P O S E O F T H E C O P ?
P R O C O P I . C O Mprocopi.com Swimming Pool heating CLIMEXEL 10HEAT/COOL PUMPS
All Climexel heat pumps are reversible as standard. A Climexel heat pump can be set to heat or cool pool water. This feature is particularly useful in very hot regions where it is necessary to maintain the pool water at a pleasant temperature, and to lower and maintain the water temperature in aquaculture tanks used to rear and store fish.
R E V E R S I B L E H E AT P U M P S
Climexel heat pumps’ electrical requirements have been reduced through the use of electrical current rectifiers.
E L E C T R I C A L C U R R E N T R E Q U I R E M E N T
T H E T E C H N O L O G Y
Climexel heat pumps feature an acceleration ramp, a characteristic of Inverter®
technology, that avoids overcurrents on start-up along with their inherent negative impact on electrical and electronic devices in the home. The machine’s electrical current requirement is lower than that of an equivalent On/Off device, this means that cable cross sections and thermal protection can be reduced.
S TA R T U P O V E R C U R R E N T S
S E R I E S
P o o l & S p a E q u i p m e n t
Swimming Pool heating CLIMEXEL 11HEAT/COOL PUMPS
The pool water flows axially between the coils of the spiral
The heat transfer fluid circulates in the single
channel spiral
TITA
NIUM
HEA
T
EXCHANGER
GUARANTEE
YEAR
C L I M E X E L H E AT E X C H A N G E R
A heat exchanger is a device that transfers heat from a hot body to a cold body or vice versa. The larger the surface area, the better the yield. For this reason, Procopi fits all Climexel heat pumps with spiral plate exchangers that offer a much larger heat exchange surface area than tube exchangers.
W H AT I S A H E AT E X C H A N G E R ?
> E X T R E M E LY R O B U S T > C O M P L E T E LY L E A K T I G H T > E X T E N D E D S E R V I C E L I F E ( + M O R E T H A N 2 0 Y E A R S )
Water inlet/ outlet
Heat transfer fluid inlet/ outlet
Sensor position
Pool water axial circuit
Heat transfer fluid spiral
The titanium, sprial plate exchanger is a Procopi exclusive.
Its large surface area guarantees excellent performance data.Made of titanium, it is compatible with all water treatment methods available, notably salt water electrolysis.
P U R E T I TA N I U M , S I N G L E C H A N N E L , S P I R A L P L AT E H E AT E X C H A N G E R
55 YE
AR
SY
EA
RS
GUARANTEE
TITANIUMEXCHANGER
procopi.com Swimming Pool heating CLIMEXEL 12HEAT/COOL PUMPS
C L I M E X E L M . P. I .H E AT P U M P S
Improved heating power and COP (coefficient of performance), Reversible machine, can be used to heat or cool the pool water, The pool water temperature, set point and operating mode (heat/cool) are displayed on the remote control, Automatic defrosting by cycle inversion, allows the machine to work at temperatures down to -15°C, Complies with EC standards, Low acoustic power in low speed mode, thanks to the Mitsubishi Scroll Inverter, Titanium, helical plate heat exchangers (Procopi exclusive), compatible with salt electrolysis,
Wired remote control (option), Low water level safety device (flow switch), Wired in via a watertight deck box, Anti-UV treated ABS casing allowing integration of a regulator, deck box, heat exchanger, flow controller, sensors, communication and control circuit boards,
Hydraulic connections solvent unions, Ø 50 mm, ICHILL Thermostat, comfort mode and Eco mode, Condensate drainage and recovery kit.
T E C H N I C A L D ATA
Models / Dimensions (in mm) A B C D E F G H
1 fan
M.P.I. - 80M 455 500 330 222 975 235 205 600
M.P.I. - 100M 455 500 330 222 975 235 205 600
M.P.I. - 160M 330 600 370 240 1145 335 266 943
2 fans
M.P.I. - 190M 330 600 370 240 1245 335 412 1350
M.P.I. - 190T 330 600 370 240 1245 335 412 1350
M.P.I. - 240M 330 600 370 240 1245 420 327 1350
M.P.I. - 240T 330 600 370 240 1245 420 327 1350
M.P.I. - 320T 330 600 370 240 1245 420 327 1335
M.P.I. - 380T 330 600 370 240 1245 420 327 1335
M.P.I. - 160M.P.I. - 190 M.P.I. - 320 M.P.I. - 240 M.P.I. - 380 M.P.I. - 80 M.P.I. - 100
F I R S T P L A C E A W A R D F O R I N N O V AT I O N , 2 0 1 3
S E R I E S
S E R I E S
P o o l & S p a E q u i p m e n t
Swimming Pool heating CLIMEXEL 13HEAT/COOL PUMPS
M A I N C H A R A C T E R I S T I C S O F A N I N V E R T E R H E AT P U M P I N I T S V A R I O U S O P E R AT I N G M O D E S .
The Climexel M.P.I heat pumps automatically select the operating mode best suited to the current weather and operating conditions. : Low speed: the heat pump operates in this mode when it is close to the set point (within approximately 1°C). Climexel M.P.I. heat pumps can operate at three speeds below 50 Hz (Step 1, 2 and 3). At these speeds, Climexel M.P.I. heat pumps offer a COP and sound levels that cannot be achieved by conventional On/ Off heat pumps. Cruising speed: This is the operating speed of a standard On/ Off heat pump, it corresponds to a compressor speed of 50 Hz, or Step 4. High speed: Climexel M.P.I. heat pumps operate at one of three speeds greater than 50 Hz (Steps 5, 6 and 7) during the initial heating ramp or when weather conditions are harsh.
NOTA BENE: The technical data shown in both or the table above has been certified by CETIAT and was collected according to the EN-14511 protocol, recommended in DTP no. 10 of the ‘Fédération des Professionnels de la Piscine’ (French federation of pool professionals) and used by CERTITA, in its certification standard ‘NF Heat Pumps’.
M.P.I.-80MM.P.I.-100M
M.P.I.-160M
M.P.I.-190M
M.P.I.-190T
M.P.I.-240M
M.P.I.-240T
M.P.I.-320T
M.P.I.-380T
Certified heating capacity, Air at 26°C, Water at 26°C
12 kW 15 kW 24 kW 29 kW 29 kW 36 kW 36 kW 48 kW 57 kW
Certified heating capacity, Air at 15°C, Water at 26°C
8 kW 10 kW 16 kW 19 kW 19 kW 24 kW 24 kW 32 kW 38 kW
Cooling capacity, Air at 35°C, Water at 28°C
4.3 kW 5.4 kW 12.4 kW 18.4 kW 18.4 kW 19.1 kW 19.1 kW 33.2 kW 34.6 kW
Maximum pool water volume** ≤ 52 m3 ≤ 65 m3 ≤ 104 m3 ≤ 123 m3 ≤ 123 m3 ≤ 156 m3 ≤ 156 m3 ≤ 208 m3 ≤ 247 m3
Type of refrigerant R 410A R 410A R 410A R 410A R 410A R 410A R 410A R 410A R 410A
Recommended flow rate 4 to 5 4 to 5 4 to 6 5 to 7 5 to 7 8 to 10 8 to 10 10 to 12 12 to 14
Maximum current requirement 13.00 13.00 19.00 29.50 13.00 29.50 13.00 19.00 21.00
Power supply 230 V 1ph 230 V 1ph 230 V 1ph 230 V 1ph 400 V 3ph 230 V 1ph 400 V 3ph 400 V 3ph 400 V 3ph
Power cable cross section3 x 2,5 mm²
3 x 2,5 mm²
3 x 4 mm²
3 x 6 mm²
5 x 2.5 mm²
3 x 6 mm²
5 x 2.5 mm²
5 x 6 mm²
5 x 6 mm²
Electrical protection 16 A 16 A 25 A 32 A 16 A 32 A 16 A 32 A 32 A
Heat exchanger model Helical plate
Compressor Rotary Scroll
Quantity of refrigerant 2.10 Kg 2.10 Kg 3.20 Kg 4.60 Kg 4.60 Kg 4.60 Kg 4.60 Kg 7.10 Kg 7.70 Kg
Number of fans 1 1 1 2 2 2 2 2 2
Dimensions L x W x H (mm)995x495
x600995x495
x6001150x360
x9501250x360
x13501250x360
x13501250x360
x13501250x360
x13501250x360
x13401250x360
x1340Weight 49 Kg 49 Kg 82 Kg 125 Kg 137 Kg 125 Kg 137 Kg 142 Kg 148 Kg
M.P.I.80M
M.P.I.100M
M.P.I.160M
M.P.I.190M190T
M.P.I.240M240T
M.P.I.320T
M.P.I.380T
LOW SPEED STEP 1 : 20 Hz
COP* 7.5 7.6 7.26 6.86 6.42 5.03 4.48
Acoustic pressure level at 10 m, in dB (Lp) 24 24 29 27 30 34 34
Acoustic power, in dB (Lw) 52 52.8 57.9 55.8 58.7 62.9 62.9
CRUISING SPEED
STEP 4 : 50 Hz
COP* 6.2 6.3 5.04 5.47 6.18 5.3 4.73
Acoustic pressure level at 10 m, in dB (Lp) 27 28 33 29 34 39 39
Acoustic power, in dB (Lw) 55.6 56.5 61.9 57.8 62.8 67.3 67.3
HIGH SPEED STEP 7 : 100 Hz
COP* 4.9 5.1 3.75 4.37 5.34 4.32 3.87
Acoustic pressure level at 10 m, in dB (Lp) 34 35 40 40 43 47 47
Acoustic power, in dB (Lw) 62 63 69 68.6 72 76 76
* : Air temperature 15°C. Water temperature 26 °C.** : The values indicated are valid under ideal conditions: Ambient air temperature 15°C. Water temperature 26°C. Pool covered with an isothermal cover at night, Filtration system running at least 15 hours a day during the heating season.
procopi.com Swimming Pool heating CLIMEXEL 14HEAT/COOL PUMPS
C L I M E X E L M . Z . I .H E AT P U M P S ( A L L S E A S O N S )
Models / Dimensions (in mm) A B C D E F G H
2 fans
M.Z.I. - 160M 330 600 370 240 1245 335 412 1335
M.Z.I. - 190M 330 600 370 240 1245 335 412 1335
M.Z.I. - 190T 330 600 370 240 1245 335 412 1335
M.Z.I. - 320T 330 600 370 240 1245 420 327 1335
T E C H N I C A L D ATA Improved heating power and COP (coefficient of performance), Reversible machine, can be used to heat or cool the pool water, The pool water temperature, set point and operating mode (heat/cool) are displayed on the remote control, Automatic defrosting by cycle inversion, allows the machine to work at temperatures down to -15°C, Complies with EC standards, Low acoustic power in low speed mode, thanks to the Mitsubishi Scroll Inverter, Titanium, helical plate heat exchangers (Procopi exclusive), compatible with salt electrolysis, Wired remote control (option),
Low water level safety device (flow switch), Wired in via a watertight deck box, Anti-UV treated ABS casing allowing integration of a regulator, deck box, heat exchanger, flow controller, sensors, communication and control circuit boards,
Hydraulic connections solvent unions, Ø 50 mm, ICHILL Thermostat, comfort mode and Eco mode, Condensate drainage and recovery kit.
P o o l & S p a E q u i p m e n t
Swimming Pool heating CLIMEXEL 15HEAT/COOL PUMPS
S E R I E S
* : Air temperature 15°C. Water temperature 26 °C.** : The values indicated are valid under ideal conditions: Ambient air temperature 15°C. Water temperature 26°C. Pool covered with an isothermal cover at night, Filtration system running at least 15 hours a day during the heating season.
NOTA BENE: The technical data shown in both or the table above has been certified by CETIAT and was collected according to the EN-14511 protocol, recommended in DTP no. 10 of the ‘Fédération des Professionnels de la Piscine’ (French federation of pool professionals) and used by CERTITA, in its certification standard ‘NF Heat Pumps’.
M A I N C H A R A C T E R I S T I C S O F A N I N V E R T E R H E AT P U M P
I N I T S V A R I O U S O P E R AT I N G M O D E S .
The Climexel heat pumps automatically select the operating mode best suited to the current weather and operating conditions. :
Low speed: the heat pump operates in this mode when it is close to the set point (within approximately 1°C). Climexel M.Z.I. heat pumps can operate at three speeds below 50 Hz (Step 1, 2 and 3). At these speeds, Climexel M.Z.I. heat pumps offer a COP and sound levels that cannot be achieved by conventional On/ Off heat pumps.
Cruising speed: This is the operating speed of a standard On/ Off heat pump, it corresponds to a compressor speed of 50 Hz, or Step 4.
High speed: Climexel M.ZI. heat pumps operate at one of three speeds greater than 50 Hz (Steps 5, 6 and 7) during the initial heating ramp or when weather conditions are harsh.
M.Z.I.-160M M.Z.I.-190M M.Z.I.-190T M.Z.I.-320T
Certified heating capacity, Air at 26°C, Water at 26°C
24 kW 29 kW 29 kW 48 kW
Certified heating capacity, Air at 15°C, Water at 26°C
16 kW 19 kW 19 kW 32 kW
Cooling capacity, Air at 35°C, Water at 28°C
11.3 kW 16.5 kW 16.5 kW 27.6 kW
Maximum pool water volume** ≤104m3 ≤123m3 ≤123m3 ≤208m3
Type of refrigerant R 410A R 410A R 410A R 410A
Recommended flow rate 4 to 6 m3/h 5 to 7 m3/h 5 to 7 m3/h 10 to 12 m3/h
Maximum current requirement 30 A 35 A 13 A 26 A
Power supply 230 V 1ph 230 V 1ph 400 V 3ph 400 V 3ph
Power cable cross section 3 x 6 mm² 3 x 6 mm² 5 x 2.5 mm² 5 x 6 mm²
Electrical protection 32 A 40 A 16 A 32 A
Heat exchanger model Helical plate
Compressor Rotary Scroll Scroll Scroll
Quantity of refrigerant 5.50 Kg 5.50 Kg 5.50 Kg 7.10 Kg
Number of fans 2 2 2 2
Dimensions L x W x H (mm) 1250x360x1350 1250x360x1350 1250x360x1350 1250x360x1340
Weight 127 Kg 127 Kg 141 Kg 155 Kg
M.Z.I. 160M
M.Z.I. 190M190T
M.Z.I. 320T
LOW SPEED STEP 1 : 20 Hz
COP* 6.2 6.2 6.1
Acoustic pressure level at 10 m, in dB (Lp) 30 31 35
Acoustic power, in dB (Lw) 57.9 58.7 62.9
CRUISING SPEED
STEP 4 : 50 Hz
COP* 6.2 6.2 5.4
Acoustic pressure level at 10 m, in dB (Lp) 34 35 39
Acoustic power, in dB (Lw) 61.9 62.8 67.3
HIGH SPEED STEP 7 : 100 Hz
COP* 5.7 5.4 4.1
Acoustic pressure level at 10 m, in dB (Lp) 41 42 47
Acoustic power, in dB (Lw) 69.0 70.0 75.0
J U S T T H I N K !With our free software application Procopi HEATING STUDY, size your heat pump with absolute precision. This application is available on procopi.com as well as on our DVD.
1214
2 - :
Non
-con
tract
ual d
ocum
ent.
Data
is p
rovid
ed fo
r inf
orm
atoi
n pu
rpos
es o
nly
and
may
be
subj
ect t
o m
odific
atio
n wi
thou
t prio
r not
ificat
ion.
Cop
yrig
ht p
rote
cted
. Cre
ated
by:
Pro
copi
(03/
2016
e).
To guarantee complete reliability, all Climexel heat pumps are tested before being shipped.
S Y S T E M AT I C Q U A L I T Y C O N T R O L
Climexel heat pumps are covered by a 3 year guarantee. The guarantee period is extended to 5 years for the heat pump’s titanium exchanger and the compressor.
D U R AT I O N O F T H E G U A R A N T E E
H E AT I N G S T U D Y
C L I M E X E L / M I T S U B I S H I ® H E AT P U M PG U A R A N T E E C O N D I T I O N S
HEAT/COOL PUMPS
S E R I E S
33 YE
AR
SY
EA
RS
GUARANTEE
HEAT PUMP
55 YE
AR
SY
EA
RS
GUARANTEE
COMPRESSOR
55 YE
AR
SY
EA
RS
GUARANTEE
TITANIUMEXCHANGER
P o o l & S p a E q u i p m e n t