septic...2019/06/12 · septic tank aerator (paddle or diffusor) pump & alarm disposal...
TRANSCRIPT
![Page 1: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/1.jpg)
![Page 2: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/2.jpg)
SEPTIC TANK LEACH
FIELD
“CONVENTIONAL SYSTEM”
ON-SITE TREATMENT
![Page 3: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/3.jpg)
ANAEROBIC CONDITIONS IN THE SEPTIC TANK,
AEROBIC CONDITIONS IN THE LEACH FIELD
SCUM, LIQUID, SOLIDS
SEPTAGE
![Page 4: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/4.jpg)
“ALL” OPTIONS BEGIN WITH A SEPTIC TANK (PRIMARY TREATMENT)
ON-SITE OPTIONS
SEPTIC TANK
![Page 5: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/5.jpg)
ALTERNATIVE SYSTEMS NEEDED WHEN…
• TOO MUCH VOLUME TO TREAT
• POOR SOIL
• TOO SMALL A LOT • HIGH WATER TABLE or ENVIRONMENTALLY SENSITIVE AREA
![Page 6: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/6.jpg)
SOMETIMES CHAMBERS
ARE INSTALLED INSTEAD OF
LEACH FIELDS
![Page 7: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/7.jpg)
• MOUND SYSTEM
ON-SITE OPTIONS
![Page 8: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/8.jpg)
MOUND SYSTEM
SEPTIC TANK DOSING CHAMBER
GRAVEL
SAND
PUMP
![Page 9: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/9.jpg)
MOUND SYSTEM
BUILD WHERE:
• <10 ft to rock
• <1 inch/hr percolation
![Page 10: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/10.jpg)
• MOUND SYSTEM
ON-SITE OPTIONS
• AEROBIC SYSTEM
![Page 11: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/11.jpg)
AEROBIC SYSTEM
SEPTIC TANK
AERATOR (PADDLE or DIFFUSOR)
PUMP &
ALARM
DISPOSAL
![Page 12: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/12.jpg)
POTENTIAL PROBLEMS WITH AEROBIC
SYSTEMS
NEGLECTION FROM HOMEOWNERS
SOME STATES REQUIRE CERTIFIED OPERATORS TO MAINTAIN THESE UNITS
![Page 13: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/13.jpg)
• MOUND SYSTEM
ON-SITE OPTIONS
• AEROBIC SYSTEM
• SAND FILTER
![Page 14: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/14.jpg)
SEPTIC TANK
SAND FILTERS
AERATION TANK
SAND FILTER
•FILTERS CAN BE ABOVE GROUND (OPEN FILTER) OR BELOW GROUND (BURIED FILTER)
•ACT LIKE MINATURE TRICKLING FILTER; SO, OPEN FILTERS MUST BE RAKED AND SAND REPLACED
REGULARLY
![Page 15: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/15.jpg)
• MOUND SYSTEM
ON-SITE OPTIONS
• AEROBIC SYSTEM • SAND FILTER
• CONSTRUCTED WETLANDS
![Page 16: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/16.jpg)
CONSTRUCTED WETLANDS
•AKA-ROCK & REED FILTERS; MICROBIAL ROCK PLANT FILTERS;
VEGETATED ROCK FILTERS; VEGETATED SUBMERGED BED
WETLANDS; SHALLOW HORIZONTAL FLOW WETLANDS; MICRO-
WETLANDS; ARTIFICIAL MARSH; PHYTOREMEDIATION
![Page 17: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/17.jpg)
CONSTRUCTED WETLAND TWO TYPES:
• WATER FLOWS ON SURFACE;
• WATER FLOWS BENEATH THE SURFACE
PURPOSE IS TO ARTIFICIALLY REPRODUCE WHAT ACTUALLY
HAPPENS IN A NATURAL WETLAND
![Page 18: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/18.jpg)
SEPTIC TANK
CELLS
CONSTRUCTED WETLAND
12 INCHES GRAVEL
12 INCHES SAND & GRAVEL
![Page 19: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/19.jpg)
DISTRIBUTION PIPES INTO A CONSTRUCTED
WETLAND
![Page 20: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/20.jpg)
CONSTRUCTED WETLAND
![Page 21: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/21.jpg)
![Page 22: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/22.jpg)
VEGETATION: BULRUSHES, CATTAILS, REEDS, RUSHES, SEDGES…SHOULD BE NATURAL
VEGETATION TO ADAPT WELL AND CONTROL PESTS
![Page 23: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/23.jpg)
•PLANT ROOTS GIVE OFF OXYGEN TO AERATE THE WATER.
•AEROBIC ORGANISMS ATTACH TO ROOTS AND GRAVEL
•BACTERIA, FUNGI, PROTOZOAN, AND ENZYMES BREAK DOWN THE POLLUTANTS
HOW CONSTRUCTED
WETLANDS WORK
![Page 24: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/24.jpg)
DEATH VALLEY, CA HAS AN EVAPORATION RATE OF 150”/YR.
WHAT IS THE AVERAGE ANNUAL EVAPORATION IN SOUTHERN
NEW MEXICO?
ANS: 60-80 INCHES/YEAR
WATER LOSSES IN THE WETLANDS
![Page 25: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/25.jpg)
TRANSPIRATION • ONLY 1% OF THE WATER TAKEN UP BY PLANTS IS NEEDED, THE REST IS
“TRANSPIRED” TO THE AIR
•EXAMPLE: ONE CORN PLANT TRANSPIRES ABOUT 1/2 GALLON
OF WATER PER DAY.
• A FIELD OF CORN TRANSPIRES ABOUT 400,000 GAL PER SEASON
![Page 26: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/26.jpg)
EVAPOTRANSPIRATION
DIFFICULT TO TELL HOW MUCH WATER IS LOST TO
EVAPORATION AND HOW MUCH TO TRANSPIRATION, SO… THE LOSSES ARE LUMPED TOGETHER
AND CALLED “EVAPOTRANSPIRATION”
![Page 27: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/27.jpg)
OTHER WATER LOVING PLANTS
• DEEP-ROOTED TREES CALLED “PHREATOPHYTES” (MEANING THEY TAKE WATER FROM THE
WATER TABLE)
• TAMERISK (aka SALT CEDARS), COTTONWOOD ARE PHREATOPHYTES
![Page 28: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/28.jpg)
CONSTRUCTED WETLANDS ARE GROWING IN POPULARITY.
BENEFITS: INEXPENSIVE TO CONSTRUCT; EASY TO MAINTAIN;
EFFICIENT AND RELIABLE; CAN TOLERATE LOW OR HIGH FLOWS AND VARYING CONTAMINANT
LEVELS; AESTHETICALLY PLEASING AND PROVIDE A HABITAT FOR
WILDLIFE AND HUMAN ENJOYMENT
![Page 29: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/29.jpg)
DISADVANTAGES OF CONSTRUCTED WETLANDS
•MAY REQUIRE LARGE LAND AREA
• NEW TECHNOLOGY AND ALL THE “BUGS” ARE NOT YET WORKED OUT
•BIOLOGICAL AND HYDROLOGICAL PROCESSES NOT WELL UNDERSTOOD
•MAY BE POSSIBLE PEST PROBLEMS
![Page 30: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/30.jpg)
REMOVAL EFFICIENCIES of CONSTRUCTED
WETLANDS
1st CELL 2nd CELL
BOD/TSS 75% 90+%
FECAL COLIFORM 95% 99.9%
AMMONIA (NH3) 40% 99.9%
![Page 31: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/31.jpg)
IRRIGATION SYSTEMS
• DRIP TECHNOLOGY CAME FROM ISRAEL. SEPTIC
TANK EFFLUENT MUST GO THRU A SERIES OF DISK
FILTERS TO PREVENT NOZZLE CLOGGING
![Page 32: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/32.jpg)
DRIP IRRIGATION TRENCHES
![Page 33: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/33.jpg)
SPRAY IRRIGATION
![Page 34: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/34.jpg)
CLUSTER SYSTEMS
SOME SMALL COMMUNITIES (OR SEVERAL HOUSEHOLDS) “CLUSTER” TOGETHER AND
INSTALL A SMALL CENTRALIZED SYSTEM
![Page 35: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/35.jpg)
COMBINED SETTLING AND DIGESTION UNITS
• USUALLY CONSIDERED “PACKAGED TREATMENT PLANTS” BECAUSE THEY
ARE FACTORY-BUILT AND SHIPPED TO THE SITE AS
A PACKAGE
![Page 36: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/36.jpg)
COMBINED SETTLING/DIGESTION
THESE UNITS ARE ALL COPIED
FROM THE IMHOFF TANK
![Page 37: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/37.jpg)
IMHOFF TANK
SLUDGE WITHDRAWAL
SETTLING
SLUDGE DIGESTION
GAS VENT
![Page 38: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/38.jpg)
CLARIGESTER™
BUILT IN SCREEN
SETTLING
DIGESTION
GAS BURNER
![Page 39: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/39.jpg)
PACKAGE TREATMENT PLANT
![Page 40: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/40.jpg)
PACKAGE PLANT FLOW CHART
![Page 41: SEPTIC...2019/06/12 · SEPTIC TANK AERATOR (PADDLE or DIFFUSOR) PUMP & ALARM DISPOSAL POTENTIAL PROBLEMS WITH AEROBIC SYSTEMS NEGLECTION FROM HOMEOWNERS SOME STATES REQUIRE MAINTAIN](https://reader030.vdocuments.mx/reader030/viewer/2022041116/5f2ad1860af58f66b60096ab/html5/thumbnails/41.jpg)
CLARIGESTER™
BUILT IN SCREEN
SETTLING
DIGESTION
GAS BURNER