september 17th sigfox radiated performance ......september 17th 2018 sigfox radiated performance...

16
September 17 th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use

Upload: others

Post on 26-May-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

September 17th 2018

SIGFOX RADIATED

PERFORMANCE

TEST PLAN

Public use

Page 2: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

2

Revision History

Revision Number Date Author Change description

0.1 August 15th, 2017 B.Ray Initial spec

0.2 October 5th, 2017 B.Ray Antenna gain in dB

0.3 November 16th, 2017 B.Ray RC3a, RC3c, RC5

0.4 May 23th, 2018 B.Ray RC6

0.5 September 14th, 2018 B.Ray Adapt wording to fit new approach

Content

I. Introduction ................................................. 5

1. Acronyms and abbreviations .......................................... 5

2. Scope .............................................................................. 5

3. Definitions ....................................................................... 6

II. TX Test Setup ............................................. 8

1. ERP or EIRP ................................................................... 9

2. Radiation pattern .......................................................... 10

III. RX Test setup (optional) ......................... 12

1. RX radiated sensitivity (optional) .................................. 12

APPENDIX A .................................................. 14

APPENDIX B .................................................. 15

APPENDIX C .................................................. 16

Page 3: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

3

Page 4: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

1. Introduction

Page 5: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

5

I. Introduction

1. Acronyms and abbreviations

- CE: European Commission - CW: Continuous wave - DUT: Device Under Test - EIRP: Effective Isotropic Radiated Power - ETSI: European Telecommunications Standards Institute - ERP: Effective Radiated Power - FCC: Federal Communications Commission - GFSK: Gaussian Frequency Shift Keying - RC: Radio Configuration - RF: Radio Frequency - RX: Receive - TX: Transmit

2. Scope This document applies to Sigfox partners planning the radiated tests of the Sigfox ReadyTM Certification for device. Radiated tests will be performed by Sigfox accredited test house. Filing is checked by Sigfox through the BUILD platform build.sigfox.com. This document intents to describe the test setup and test procedure for each radiated test being performed for the Sigfox ReadyTM certification. Throughout this document, the Device under Test (DUT) refers to the device to be certified. Important: The Sigfox ReadyTM certification for device does not substitute local regulatory requirements (CE marking, FCC, ETSI or other type approval) where the device is to be deployed. It is the partner`s responsibility to comply with local country regulations.

Page 6: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

6

3. Definitions

The effective radiated power (ERP) is the power radiated in the direction of maximum field strength under specified conditions of measurements. ERPdBm= Conducted_RF_PowerdBm + Antenna_GaindB EIRP refers to an isotropic antenna whereas ERP refers to a perfect dipole antenna. The relation between ERP and EIRP is: EIRPdBm = ERPdBm + 2.15dB The radiation pattern is the variation of the power radiated by an antenna as a function of the direction away from the antenna. This power variation, as a function of the arrival angle, is observed in the antenna’s far field. Radiated receiver sensitivity is the minimum level of signal at the receiver input, produced by a carrier at the nominal frequency of the receiver, modulated with the normal test signal modulation. EIRP and radiation pattern tests are mandatory for Sigfox Ready TM filing. The receiver sensitivity test is optional but highly recommended. It only applies to DUT operating in bidirectional communication way.

Page 7: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

2. TX Test Setup

Page 8: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

8

II. TX Test Setup

Measurements shall be carried out under normal conditions (temperature, humidity, pressure) in the following test sites:

• Open Area Test Site (OATS)

• Semi Anechoic Room (SAR)

• Or Fully Anechoic room (FAR)

Figure 1 Fully Anechoic room (FAR)

Coordinate system anechoic chamber (OTA) can also be used for testing.

Page 9: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

9

Figure 2 Coordinate system anechoic chamber (OTA)

Measurement antenna is connected to a spectrum analyzer The chamber and the cable loss must be calibrated at least up to 1GHz.

1. ERP or EIRP

Test procedure:

• DUT is activated with CW TX test mode (non-modulated Continuous Wave mode) at dedicated RC frequency test (see Appendix C) and maximum power

• For RC1, RC3a, RC3c, RC5, RC6 maximum ERP (Effective Radiated Power) is measured and recorded following the ETSI EN 300-220 (2017-02) standard test procedure whereas for RC2 and RC4, maximum EIRP (Effective Isotropic Radiated Power) is measured and recorded following the FCC Part15-247 standard.

• During measurement, DUT shall be placed in normal use position as declared by the provider

• For multi-position end-product, the DUT EIRP measurement can be performed in 3 dimensions if needed

Page 10: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

10

2. Radiation pattern

Test procedure:

• DUT is activated with CW TX test mode (non-modulated Continuous Wave mode) at dedicated RC frequency test and power

• Radiated power is recorded for every 5° step of the turn table in vertical and horizontal polarization

• The radiation pattern in vertical and horizontal polarization shall be derived from the DUT where maximum EIRP occurs. It shall be normalized to maximum EIRP value and represented in polar coordinates. The measurement unit is dBm

• For multi-position DUT, the radiation pattern measurement can be performed in 3 dimensions if needed

• For multi-position DUT, the angular position step (azimuth) shall be equal or less than 5° and the tilt position step (elevation) shall be equal or less than 10°

Example of radiation patterns are provided in Appendix A

Page 11: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

3. RX Test Setup

(optional)

Page 12: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

12

III. RX Test setup

(optional)

Measurements shall be carried out under normal conditions (temperature, humidity, pressure) in the same kind of room or chamber than for the TX radiated tests.

1. RX radiated sensitivity (optional)

The receiver sensitivity test is optional but highly recommended. It only applies to DUT operating in bidirectional communication way. Two test setups are described depending on the test house available equipment.

Test setup 1: Anechoic chamber without spy antenna

Page 13: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

13

Test setup 2: Anechoic chamber with spy antenna

Test procedure:

• DUT is oriented in the position of max EIRP found in the TX EIRP test above

• DUT is activated in infinite loop RX GFSK test mode

• Generator is set in emission: o output power: -50dBm. Path loss and cable loss must be taken into

account o F1 frequency: downlink frequency is set according to RC test frequency o Modulation: GFSK. See full generator modulation parameters in

appendix B.

• Spectrum analyzer is set to the frequency F2=F1-50kHz corresponding to the packet sent by the DUT when receiving the GFSK signal

• Note that the DUT usually embeds a RX narrow filter. To find reception window, frequency must be shift by step of 1kHz. Once reception window found, it must be set to the center frequency between the 2 cutoff frequencies

• F2 frequency is tracked on the spectrum analyzer in span 0Hz and sweep time is adjusted to allow easy counting of the F2 frames

• Lower the signal generator level until the communication is lost (no packet sent from the device)

• Increase the generator level by 3dB and lower again by step of 0.1dB until the sensitivity test requirement is met

Page 14: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

14

APPENDIX A

Radiation pattern in both polarization Horizontal and Vertical

Radiation pattern in coordinate system anechoic chamber

Page 15: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

15

APPENDIX B

Signal Generator GFSK parameters:

o For SMIQ Signal Generator from R&S

DATA LIST: AA AA B2 27 1F 20 41 84 32 68 C5 BA 53 AE 79 E7 F6 DD 9B

o For SMBV100A Signal Generator from R&S

In « baseband », go to custom digital modulation and enter following parameters: - Adjsut freq and power level - Create a data_list with following pattern: AA AA B2 27 1F 20 41 84 32 68 C5 BA 53 AE 79 E7 F6 DD 9B - No control list - symbol rate = 600 symb/s - coding off - modulation type = 2FSK - deviation = 800 Hz - filter = Gauss(FSK) and B*T = 0.35

Page 16: September 17th SIGFOX RADIATED PERFORMANCE ......September 17th 2018 SIGFOX RADIATED PERFORMANCE TEST PLAN Public use 2 Revision History Revision Number Date Author Change description

16

APPENDIX C

CW test frequency versus RC:

RC CW test frequency in uplink

RC1 868.13MHz

RC2 902.2MHz

RC3a, RC3c 923.2MHz

RC4 920.8MHz

RC5 923.3MHz

RC6 865.2MHz