self-healing multi-drop model fiber optic modem (dual channel) … · 2018-07-25 · solidly lit...

4
Self-Healing Multi-Drop Fiber Optic Modem (Dual Channel) Model TC2100 • Async Data Rates up to 38.4 Kbps • Protocol Transparent • All-Digital Design • Multiple Master Capability • Multimode (850/1300nm) or Single Mode (1300/1550nm) • RS-232, RS-422 or RS-485 (2/4-wire) • Local and Remote Loopback Tests • Optical Loop Integrity Test • Anti-Streaming (Anti-Jabber) • Local Dry Contact Alarm Relay • Hardened Temperature Versions (optional) • Hi-Temp2 Version Exceeds NEMA & Caltrans Traffic Control Specs he TC2100 Multi-Drop Fiber Optic Modem provides maximum reliability for linking monitoring devices (typically RTUs or PLCs) to a Host Controller or CPU. It is completely transparent to data or communications protocols. The TC2100 can be configured in Ring or Self-Healing Ring topologies. The Self-Healing Ring scheme is sophisticated, i.e. it detects upstream and downstream failures on both Tx and Rx, and automatically re-routes any cable or equipment failure. TC2100 master and TC2101 slave units are interchangeable by setting a dip switch. “Multiple master” units are optional. It supports asynchronous data rates up to 38.4 Kbps. Electrical interfaces are RS-232, RS-422 or RS-485. The RS-485 electrical port can be multi-dropped. There are two optional versions (Model TC2100T) for extreme temperature applications (-20°C to 70°C & -40°C to 80°C). Each unit comes standard with two pairs of fiber interfaces and either 2-Channel RS-232 or 1-Channel RS-422/RS-485 interfaces. The second channel on the RS-232 interface can be used for data, RTS/CTS handshaking signals or as a telephone extension with the Model TC1900 “Quick-Talk” phone adapter. Local and remote loopback is standard. Diagnostic LEDs are provided to help installation and troubleshooting. Dry contact alarms can be connected to RTUs/PLCs to indicate specifically where a fault has occurred. A test signal generator for verifying link integrity is provided to aid installation and troubleshooting. “Anti-streaming” capability is standard. The TC2100 is compatible with all popular types and sizes of fiber optic cable and is available multimode (850/1300nm) or single mode (1300/1550nm). Fiber optic connectors are ST or FC. Electrical connectors are DB25 female. Power is 12VDC; optional 24VDC, -48VDC, 125VDC or 115/230VAC with an external power cube. T Applications Renowned for its high reliability, the TC2100 Multi-Drop Modem is ideal for Ring or Self-Healing Ring communication links in SCADA, Traffic Control, Industrial Process Control and Security Networks. It is frequently used to interconnect Remote Terminal Units (RTUs) or Programmable Logic Controllers (PLCs) in Utility substation SCADA Networks. TC Communications, Inc. 17881 Cartwright Rd. Irvine, CA 92614 U.S.A. Tel: (949) 852-1972, Fax: (949) 852-1948 Sales: (800) 569-4736 Web Site: www.tccomm.com E-mail: [email protected] 2 X TC2100R (Housed in TCRM196 19” Wide, 1U High Rackmount Card Cage) TC2100S Standalone Unit

Upload: lykhuong

Post on 11-Jul-2019

214 views

Category:

Documents


0 download

TRANSCRIPT

Self-Healing Multi-DropFiber Optic Modem (Dual Channel)

Model TC2100

•AsyncDataRatesupto38.4Kbps

•ProtocolTransparent

•All-DigitalDesign

•MultipleMasterCapability

•Multimode(850/1300nm)orSingleMode(1300/1550nm)

•RS-232,RS-422orRS-485(2/4-wire)

•LocalandRemoteLoopbackTests

•OpticalLoopIntegrityTest

•Anti-Streaming(Anti-Jabber)

•LocalDryContactAlarmRelay

•HardenedTemperatureVersions(optional)

•Hi-Temp2VersionExceedsNEMA&CaltransTrafficControlSpecs

he TC2100 Multi-Drop Fiber Optic Modem provides maximumreliability for linking monitoring devices (typically RTUs or PLCs)

to a Host Controller or CPU. It is completely transparent to data orcommunicationsprotocols.

TheTC2100canbeconfiguredinRingorSelf-HealingRingtopologies.TheSelf-HealingRingschemeissophisticated, i.e. itdetectsupstreamanddownstreamfailuresonbothTxandRx,andautomaticallyre-routesanycableorequipmentfailure.TC2100masterandTC2101slaveunitsareinterchangeablebysettingadipswitch.“Multiplemaster”unitsareoptional.

It supports asynchronous data rates up to 38.4 Kbps. ElectricalinterfacesareRS-232,RS-422orRS-485.TheRS-485electricalportcanbemulti-dropped.Therearetwooptionalversions(ModelTC2100T)forextremetemperatureapplications(-20°Cto70°C&-40°Cto80°C).

Each unit comes standard with two pairs of fiber interfaces andeither 2-Channel RS-232 or 1-Channel RS-422/RS-485 interfaces. ThesecondchannelontheRS-232interfacecanbeusedfordata,RTS/CTShandshakingsignalsorasatelephoneextensionwiththeModelTC1900“Quick-Talk”phoneadapter.

Localandremoteloopbackisstandard.DiagnosticLEDsareprovidedto help installation and troubleshooting. Dry contact alarms can beconnected to RTUs/PLCs to indicate specifically where a fault hasoccurred.Atestsignalgeneratorforverifyinglinkintegrityisprovidedtoaid installationandtroubleshooting.“Anti-streaming”capability isstandard.

The TC2100 is compatiblewith all popular types and sizes offiberoptic cable and is availablemultimode (850/1300nm) or singlemode(1300/1550nm).FiberopticconnectorsareSTorFC.ElectricalconnectorsareDB25female.Poweris12VDC;optional24VDC,-48VDC,125VDCor115/230VACwithanexternalpowercube.

T

Applications

Renownedforitshighreliability,theTC2100Multi-DropModemisidealforRingorSelf-HealingRingcommunicationlinksinSCADA,TrafficControl,IndustrialProcessControlandSecurityNetworks.ItisfrequentlyusedtointerconnectRemoteTerminalUnits(RTUs)orProgrammableLogicControllers(PLCs)inUtilitysubstationSCADANetworks.

TC Communications, Inc.17881 Cartwright Rd. Irvine, CA 92614 U.S.A.

Tel: (949) 852-1972, Fax: (949) 852-1948Sales: (800) 569-4736

Web Site: www.tccomm.comE-mail: [email protected]

2XTC2100R(HousedinTCRM19619”Wide,1UHighRackmountCardCage)

TC2100SStandaloneUnit

SCADAMASTER

Ch. 1

Ch. 2

Ch. 1 Ch. 2

Ch. 2

RS-232

Ch.1 Ch. 2

RS-232

RS-232

Ch. 1Ch. 2

AMRMASTER

Self-HealingFiber Optic Ring(SCADA & AMR)

Fiber

Copper

MeterM

MM

M

M

TC2101

TC2101

TC2100(Master)

Sample Application #1

TC2101

TC2101

RS-232

RS-232

Ch. 1

CENTRALCOMPUTER

Ch. 1

Ch. 1

Ch. 1 RS-232

RS-232

Ch. 2

Ch. 2

RS-232

2-wire

2-wire

POTS

POTSCh. 1

RS-232

RS-232

RS-232

PBXorKEY

SYSTEM

FiberCopper

TC1900

TC1900

TC2101

TC2101

TC2100(Master)

PUBLICSWITCH

TELEPHONENETWORK

Ch. 1

Sample Application #2

Self-HealingFiber Optic Ring

(Traffic Control & Voice)

TC2101

TC2101

Typical SCADA and AMR Application Using TC2100 “ Self-Healing” Fiber Modems In a Utility Substation Environment

Typical Poll Response Application Using TC2100 “Self-Healing” Fiber Modems In a Traffic Control Environment

What Makes the TC2100 Self-Healing Ring Different from Other Vendors?

ManyoftheTC2100’sfeaturesarecriticaltonetworkoperation;someareuniqueforaproductofthistype.Itisimportanttonotethattheterm“Self-HealingRing”meansdifferentthingstodifferentvendors.BecausethereisnoindustrystandardforSelf-HealingRings,vendorofferingsvarygreatlyintermsoffunction,featuresandsophis-tication.

TheTC2100SelfHealingRingdiffersfromcompetitorofferingsinitssophistication.Thissophisticationenablesittobuildinavarietyofuserbenefitsoftennotavailablewithmanyothervendor’sSelf-HealingRings.

Thesebenefitsinclude:

•The TC2101 Slave Unit Provides Loop Monitor Signal LEDs that Detect if any Incorrect Fiber Cables are Con-nected.

SolidlylitgreenLPA(Loop“A”)andLPB(Loop“B”)LEDsindicateanormalsystem;blinkinggreenLEDsin-dicatethatthefibercableshavebeencross-connected.

Somevendorsdonotofferanysimplemeanstoverifythatthefiberopticcablesarecross-connectedatre-motenodes.

Thisisabsolutelycritical!Forexample,ifatechnicianin-advertentlycross-connectstheRingAandRingBcablestoamodem,thenetworkwillappeartofunctionnor-mally,buttheSelf-Healingportionwillnotbeoperable.Techniciansmusthavespecificdiagnosticstopinpointwheretheerrantcablecross-connecthasoccurred.

•The TC2100 can Detect Faults Both Upstream and Downstream from Each Unit.

TheTC2100candetectcablebreakageatbothtransmitandreceivingsides.Somevendor’sSHRproductsdetectcablebreakageonlyatthereceivingside.Unlessthedevicecandetectfailuresatthetransmitside,thereisnowaytoknowifthenextdeviceisreceivingthesignal(seeadjacentdiagram).

•The TC2100 Prevents any Type of Echo Effect.

Somevendorsofferaself-healingschemethatdoesn’tseparatebroadcastandreceivechannels.Thisoftenresultsinan“Echo”effectthatcandisablenetworkcommunications.(”Echo”happenswhenthedatasignaltransmittedintotheMasterunit,andaroundthering,isreceivedbackattheMasterunit’sport).

•Each TC2101 (Slave) Includes a Dry Contact Alarm which Enables Pinpointing any Fault.

Techniciansmustbeabletopinpointexactlywhereafaulthasoccurred.Adryalarmcontactonthemodem’smasterunitindicateswhenself-healinghasoccurredsomewhereonthering.Dryalarmcontactsfromthemodemslaveunitsoneithersideofafaulteffectivelypinpointthelocationofthebreakorfailure(seedia-gram).

•The TC2100 Offers a Multiple-Master Self-Healing Ring Topology.

Thisinnovativeconfigurationvirtuallydoublesthereli-abilityofasingleMasterbecauseitcanrecoverfaultsorfailuresinbothringsAandBintwodifferentplaces(Seediagramonpage4).SystemintegrityismaintainedbecausebothMasterunitspolltheSlavesatthesametime,butthroughdifferent“half”rings.

•The TC2100 Provides Two Channels for Data, Con-trols or a Telephone Link (via the TC1900 Telephone Adapter)

UsetwochannelsforRS-232oroneforRS-422orRS-485.YoucanalsoaddtelephoneservicebyusingtheTC1900RS-232TelephoneExtender.TheTC1900iscompatiblewithmostanalogPBXsandenablesdial-uptelephoneextensionstobepluggedintoRS-232circuits.

•The TC2100 Provides a Built-In Test Signal Generator to Verify Optical Loop Integrity

Abuilt-intestsignalgeneratorprovidesasimpleandeffectivemethodforaselftestverifyinglinkintegrity.

FiberCopper

Tra�cController

TC21011tluaF2tluaF

4tluaF3tluaF

TxA

RxBTxB

RxA

XX XX

Fiber breakage

RS-232

SCADAMASTER

RTU/PLC

RTU/PLC

RTU/PLC

RTU/PLC

TC2101

TC2101

TC2101

dry contact

dry contact

TC2101

TC2100(Master)

X

RS-232

dry contacts CLOSE

Data RatesAsyncRS-232,RS-422,RS-485..............................................upto38.4Kbps*

OpticalTransmitter............LED/ELED/LASER*Receiver...............................PINDiodeWavelength..................850/1300nm Multimode..............1300/1550nmSingleMode

FiberOpticConnectors....................................ST,OptionalFCLossBudget*-850/1300/[email protected]/125μm20dB...........SingleMode@9/125μm

ElectricalConnector......................DB25FemaleInterface............(DCEorDTE)RS-232,............RS-422,orRS-485(2or4-wire)

SystemBitErrorRate.............1in109orbetter

Diagnostic Functions..............Local & Remote Loopback,......SignalGenerator,DisableAlarm,......................................LoopMonitor

Visual Indicators........MSTR,SLAV,Sync-A,Sync-B,Vcc,............PWRA,PWRB,ALARM,BRD-1,............BRD-2,RSP-1,RSP-2,LPA,LPB,..............................................A2B,B2A

AlarmDryContact....................NormalOPEN

PowerStandard...................12VDC @300mAOptional.....24VDC,−48VDC,125VDC,..........or115/230VACw/power cube

TemperatureOperating ...................−10°C to 50°CHi-Temp1 (optional)...−20°C to 70°CHi-Temp2 (optional)...−40°C to 80°CStorage .......................−40°C to 90°CHumidity ........95% non-condensing

Physical (Standalone Unit)Height..........................(3.53cm)1.39”Width.........................(18.13cm)7.14”Depth.........................(16.59cm)6.53”Weight.......................(567gm)1.25lbs

*Contactfactoryforhigherrequirements(LASER)

Note: Information contained in this data sheet is subject to change without prior notice.

TC Communications, Inc. 17881 Cartwright Road

Irvine, CA 92614 U.S.A.Factory Tel: (949) 852-1972

Fax: (949) 852-1948

Sales OfficeU.S.A. Domestic International:

(800) 569-4736 (949) 852-1973

Web Site: www.tccomm.comE-mail: [email protected]

®

#1045959

Self-healing function is activated on bothupstream and downstream TC2101 Slaves

TC2101 Unit Fails Fiber Cable Breaks

Dual MasterSelf-Healing Fiber Ring(Multimode or Single Mode)

Master #2

Master #1

TC2101

TC2100

TC2100

SCADAMASTER #1

SCADAMASTER #2

TC2101

TC2101

TC2101

TC2101

Amultiplemastertopology(seediagramatleft)providesmaximumreliability.ItcanmaintainRingintegritydespitefaultsorfailuresinbothringsinseveraldifferentplaces,dependingonthenumberofmasterunits.

ASelf-HealingRingconsistsoftwodatapaths,RingAandRingB,witheachdatapathrunninginanoppositedirectiontotheother.Undernormaloperationonlytheprimarydatapath(RingA)isused.

DTS-21000-01-04Rev.070213

TC2100 Self-Healing Ring with Multiple Masters

Whenthereisfault(cableorfaileddevice),thedatapathwillturnaroundbeforeitreachesthefaultorfailedunitandusethesecondarydatapathtocompletethelink.Inthismanner,thedata/communicationpathremainsintact.