section a flex - noremak...pbl16 pbl25 pbl35 pbl50 pbl70 pbl95 pbl120--flexible power cables a5...
TRANSCRIPT
Noremak IndustriesGeneral Product Catalogue 2009-2010
Aflex Cables
Mining * Construction * Shipping * Manufacturing * Lighting & Entertainment
Power Cables*Festoon Systems*Conductor Systems*Connectors*Cable ReelersHigh Voltage Couplers*Spring Reels*Grounding Reels*Fixed Power Cables
Fibre Cables*Data Accessories*Glands*Manufactured Leads*Tools*Slip RingsConveyor Monitoring Equipment*Auto Cables*Gaffa Reels*VSD Cables
Noremak Industries Pty Ltd12 Princess Street Beverley SA 5009 PH: 08 8244 7288 Fax 08 8244 7299 email:[email protected]
Cables And Equipment
Nor
mak
e
Section A Flex Power Cables
Contents
Single Double Insulated 110 EPR/CPE Flexible 0.6/1kV
Single Double Insulated R 90 Elastomer 0.6/1kV
Single Double Insulated 110 EPR/CPE 1.9/3.3kV Tinned
Single Double Insulated R90 EPR/CPE 0.6/1kV Screened
Single Insulated 90 C 0.6/1kV Flexible Earth Cables
Single Insulated R180 C 0.6/1kV Tinned Silicon
Single Insulated V90 HT PVC 0.6-1Kv Tinned Conductor
Multi Core R 90C NBR/NBR 0.6/1kV And 300/500v
Multi Core R 90 C EPR/CPE 0.6/1kV And 300/500v Tinned Conductor
Multi Core X 90 C XLPE/NBR And EPR/CPE Screened VSD
Multi Core Control V 90 C PVC/NBR 300/500v (White Numbered Cores)
Multi Core Control V 90 C PVC/PVC 300/500v (Black Numbered Cores)
Multi Core Control V 90 C PVC/PVC 300/500v Screened (Black Numbered Cores)
Multi Core R 90 C NBR/NBR 0.6/1kV Steel Braided
Twin V75 C NBR/TPE 0.6/1kV Flex Figure 8
Multi Core R 90 C EPR/PUR 0.6/1kV And 300/500v
Technical Information
A1
A2
A3
A4
A5
A6
A7
A8, A9
A10, A11
A12
A13
A14
A15
A16
A17
A18, A19
A20 To A25
Nor
mak
e
Flexible Power Cables
A1
Part No
777500163OR777500253OR777500353OR777500503OR777500703OR777500953OR777501203OR777051503OR777501853OR777502403OR777503003OR777504003OR777505003OR
Sizemm
162535507095120150185240300400500
Stranding
470/0.20726/0.201040/0.201499/0.202165/0.202745/0.201544/0.301961/0.302331/0.303172/0.303965/0.305246/0.306588/0.30
OverallDia mm
9.3010.8012.1013.7015.5017.9019.8022.1024.4027.1029.9033.5037.20
WeightKg/Km
2022933905357258701205150018402350291538174805
BellmouthLug
* Hole Size
CL16-*BMCL25-*BMCL35-*BMCL50-*BMCL70-*BMCL95-*BMCL120-*BMCL150-*BMCL185-*BMCL240-*BMCL300-*BMCL400-*BM
-
BootlacePins
UninsulatedFerrules
PBL16PBL25PBL35PBL50PBL70PBL95
PBL120------
Quick Reference
Cable Technical Information Page 20-22Current Carrying Capacities Fixed Applications Page 24
Lugs Page F1Gland Options F8, F9 & F10
Cable Construction*
*
*
*
Conductors of extra fine wires to international standards to ensure maximum flexibility. Insulation allows conductor temperature of
110 degrees C and is extremely flexible Special jacket of outstanding toughness and
flexibility, resistance to acid, solvents and oil at extreme temperatures UV stabilised and flame retardant
HALOGEN FREE
Temperature Range:
Rated Voltage
Maximum Conductor Temperature:
Bending Radius Fixed:
Available Colors:
*-30 to + 110 degrees C static -20 to +90 degrees C flexible
:* 0.6/1Kv Relevant Standards: * VDE 0250, AS 3116, AS 1995, IEC 332-3
* 110 Degrees C
* 5 times diameter of the cable
***Orange***
Nominal Current Single
phase@ 40 Deg C
13017522026534042049057066079091010701250
Single, Double Insulated 110 DegFlexible Cable 0.6/1.0KvLOW SMOKE HALOGEN FREE
0
2
110 C RATED0
Nor
mak
ePart No
777500061777500101777500161777500251777500351777500501777500701777500951777501201777051501777501851777502401777503001777504001
CrossSectionalArea mm Square
610162535507095120150185240300400
ApproxNo: of Wires
Stranding
172/0.21304/0.21462/0.21742/0.21
1050/0.211482/0.212090/0.212812/0.211480/0.311887/0.312294/0.313034/0.313811/0.315246/0.31
MaxOverall
Dia mm
8.509.5010.8012.5013.5015.5017.5020.0022.0024.5027.0030.0034.0039.00
WeightKg/Km
1181722313504516058101075133216542060257632134200
BellmouthLug
* Hole Size
CL6-*BMCL10-*BMCL16-*BMCL25-*BMCL35-*BMCL50-*BMCL70-*BMCL95-*BMCL120-*BMCL150-*BMCL185-*BMCL240-*BMCL300-*BMCL400-*BM
BootlacePins
UninsulatedFerrules
PBL06PBL10PBL16PBL25PBL35PBL50PBL70PBL95
PBL120-----
Cable Construction*
*
*
*
Conductors of extra fine wires to international standards to ensure maximum flexibility. Insulation allows conductor temperature of
90 degrees C and is extremely flexible NBR Elastomer Special jacket of outstanding toughness and
flexibility, resistance to acid, solvents and oil at extreme temperatures [see detailed properties chart of NBR Elastomer] UV stabilised and flame retardant.
Temperature Range:
Rated Voltage
Maximum Conductor Temperature:
Bending Radius Fixed:
Available Colors:
*-30 to + 90 degrees C static -20 to +90 degrees C flexible
:* 0.6/1Kv Relevant Standards: * VDE 0250, AS 3116, AS 1995, IEC 332-3
* 90 Degrees C
* 5 times diameter of the cable
***Orange, Black, Red, & Blue ******Add to Part No When Ordering***
Nominal Current Single
phase@ 40 Deg C
5981110145180220280350410470550660770900
Single, Double InsulatedFlexible Cable 0.6/1.0Kv
Flexible Power Cables
A1 A2
Quick Reference
Cable Technical Information Page 20-22Current Carrying Capacities Fixed Applications Page 23
Lugs Page F1Gland Options F8, F9 & F10
90 C RATED0
Nor
mak
eSingle, Double InsulatedFlexible CableEPR/CPE 1.9/3.3Kv
Cable Construction
* Tinned Stranded Conductors According to VDE 0295 Class 5 * EPR Rubber Insulation Type 3G13 * CPE Rubber Outer Sheath * UV stablised and flame retardant. * Resistant to oil and abrasion * Submersible to 100 Mts
Temperature Range:
Rated Voltage:
Conductor Temperature:
Bending Radius:
Available Colours:
*-40 to + 110 degrees C static -20 to +90 degrees C flexible
* 1.9/3.3Kv Relevant Standards: * VDE 0250 Part 602, AS 3116, AS3008, AS1125 Maximim
* 110 Degrees C
* 4 times diameter of the cable Static 6 Times Flexing
* Black
TYPICAL USES:
Power
Automotive
Welding
Switchboards, flexible droppers from bus bars, generators, load banks or anywhere SingleDouble insulated flexible cables are recommended
Battery leads, wiring looms, battery chargers, electric fork lifts.
Leads, Earth & Power.
CrossSectionalArea mm Square
1.52.54.06.0
10.016.025.035.050.070.095.0
120.0150.0185.0240.0300.0400.0500.0
Part No
777633105777633205777633047776330677763310777633167776332577763335777633507776337077763395
777633120777633150777633185777633240777633300777633400777633500
ApproxNo: of Wires
Max Dia mm
30/0.2550/0.2556/0.3084/0.3080/0.40
126/0.40196/0.40276/0.40396/0.40540/0.40715/0.40920/0.401138/0.401390/0.401838/0.402275/0.403035/0.403795/.040
MaxOverall
Dia mm
6.06.26.77.38.6
10.112.313.015.016.819.720.823.625.727.631.434.443.2
Nominal Current Spaced
@ 40 Deg C
3143577399
130175220265340420490570660790910
10701250
WeightKg/km
658095
120180250350455610805
10551350165519752550323042225200
Bell MouthLug
Part No* Hole Size
---
CL6-*BMCL10-*BMCL16-*BMCL25-*BMCL35-*BMCL50-*BMCL70-*BMCL95-*BM
CL120-*BMCL150-*BMCL185-*BMCL240-*BMCL300-*BMCL400BM
BootlacePins
UninsulatedFerrules
PBL15PBL025PBL04PBL06PBL10PBL16PBL25PBL35PBL50PBL70PBL95
PBL120------
Quick Reference
Cable Technical Information Page 20-22Current Carrying Capacities Fixed Applications Page 24
Lugs Page F1Gland Options F8, F9 & F10
Flexible Power Cables
A3
110 C RATED0
Nor
mak
eScreened EPR/CPEVariable Speed DriveSDI Flexible
Cable Construction
*Flexible tinned annealed copperconductors, insulation EPR type IEP3 equivalent to 3G13 according to DIN VDE0207 Part 20.
*Tinned Copper Braid screened min 80%plus aluminium / mylar tape. Separatorpolyester tape. Outer Sheath CPEelastomer
*UV stabilised and flame retardant
Maximum Conductor Temperature
Temperature Range
Bending Radius
+90CShort Circuit 250C
-30C to +90C Flexing-40C to +90C Fixed
10 x Cable Dia Fixed12 x Cable Dia Flexing
Typical UsesThe cable is designed primarily for large Variable Speed Drives and because of the dual screening gives maximum EMV protection
CrossSectionalArea mm Square
120150185240
Part No
777801120SC777801150SC777801185SC777801240SC
ApproxNo: of WiresMax Dia mm
960/0.401200/0.401470/0.401870.0.40
MaxOverall
Dia mm
23.026.028.031.5
Nominal Current Spaced
@ 40 Deg C
410470550660
WeightKg/km
1460177421702798
Bell Mouth Lugs
* Hole Size
CL120-*BMCL150-*BMCL185-*BMCL240-*BM
EMCApproved
Metal Gland
MG40EMCLMG40EMCLMG50EMCLMG50EMCL
Quick Reference
Cable Technical Information Page 20-22Current Carrying Capacities Fixed Applications Page 23
Lugs Page F1Gland Options F8, F9 & F10
CABLE PROBLEMS?NOREMAK INDUSTRIES FOR:
CABLE SOLUTIONSPHONE:(08)8244 7288 FAX:(08)8244 7299
Flexible Power Cables
A1 A4
Nor
mak
eSingle Insulated FlexibleEarth CableTPE 0.6/1kV
Cable Construction
UV stabilised & flame retardant
* Conductors of extra fine wires to international standards to ensure maximum flexibility.
* Insulation allows conductor temperatures of 90 degree C & is extremely flexible special TPE compound.
*
Temperature Range
Typical Uses
Static - 30 to + 90 degree CFlexible -20 to + 90 degree C
Power: Switchboards, Flexible droppers from busbars flexible links, transformers, generators, load banks, or anywhere green/yellow flexible earth cables are to be used. Welding earth leads.
PartNo
7771000677710010777100167771002577710035777100507771007077710095777101207771015077710300
CrossSectionalarea mm square
610162535507095
120150300
ApproxNo of WiresMax Dia mm
84/0.30128/0.30196/0.30308/0.30434/0.30608/0.30874/0.301178/0.301480/0.301887/0.303811/0.30
Nominaloverall
Dia mm
4.86.47.79.5
10.612.514.817.018.521.029.7
WeightKg/Km
109155220325430590800
1040130015002950
Lugs
* Hole Size
CL6-*BMCL10-*BMCL16-*BMCL25-*BMCL35-*BMCL50-*BMCL70-*BMCL95-*BM
CL120-*BMCL150-*BMCL300-*BM
BootlacePins
UninsulatedFerrules
PBL06PBL10PBL16PBL25PBL35PBL50PBL70PBL95
PBL120--
Flexible Power Cables
A5
Quick Reference
Lugs Page F1Gland Options F8, F9 & F10
Nor
mak
eNoremakSingle Insulated V90 HTPVC Flexible Cables0.6-1Kv Rated Tinned CopperCores Cable Construction
* Tinned copper conductors
* Insulation V90 HT PVC
* Manufactured in accordancewith AS3191 Or AS3178
Max Conductor Temperature
Available Colours
+90 C
Red, Blue, Black, Yellow,White Brown, Violet, OrangePink, Grey, GreenGreen/Yellow Other Cables Available On Request
Typical Uses
Internal Wiring of Electronic equipment, SwitchboardsControl panels
PartNo
4271C16020**4271C24020**4271C32020**4271C30025**4271C50025**4271C56030**4271C84030**
CrossSectionalarea mm square
0.500.751.001.502.504.006.00
N minalooverall
Dia mm
.6022.803.003.203.905 40.5.50
ApproxNo of WiresMax Dia mm
16/0.2024/0.2032/0.2030/0.2550/0.2556/0.3084/0.30
iInsulat on Thickness
.0 800.80
80. 00.800.90
.1 001.00
aInsul tedi R ng
e mi lT r na* e Hol Size
RRD- DGT **TRRD- DG
T - DGRBU *TRBU-*DGT Y- DGR *TRY-*DGT Y- DGR *
-Insu at dUn l eRing
Term n li a Ho e S z* l i e
TRU0 -*D5 GR 07 *DGT U -
TRU1 -*D0 GTR 15 *DGU -TRU2 -*D5 GTR 4 * GU0 - DT U0 - DGR 6 *
Flexible Power Cables
A7
Quick Reference
Current Capacities Page A21Lug Options F4
0
Nor
mak
eSingle Insulated 180Silicon Flexible Cables
0
Cable Construction
* UV stabilised & Flame Retardant
* Tinned copper conductors, all Class 5 Stranding.
* Silicon Insulation tear and heat resistant Compound
Maximum Conductor Temperature
Temperature Range
Bending Radius
+180CShort Term 220C
Static - 60 to + 180 degree CFlexible -40 to + 180 degree CShort Term 220C
4 x Cable Dia Fixed
Typical UsesElectric signs and connectionsMotor AppliancesHeavy IndustryMedical AreasShip and Railway BuildingFoundry Switch Boards
PartNo
777S01075777S01010777S01015777S01025777S01040777S01060777S01010777S01016777S01250
CrossSectionalarea mm square
0.751.01.52.54.06.0
10.016.025.0
Nominaloverall
Dia mm
2.4.52
2.83 4.
.245.26 4.8.010.0
WeightKg/Km
13.315.921.934.754.482.3
131.9209.1326.7
Un-InsulatedLugs
* Hole Size
-CL1.5-*CL1.5-*CL2.5-*CL4.0-*CL6.0-*CL10-*CL16-*CL25-*
InsulatedRing
Terminals* Hole Size
TRRD-*DGTRRD-*DGTRBU-*DGTRBU-*DGTRY-*DGTRY-*DG
---
Colours Available
0.75mm To 1.5mm:2.5mm4.0mm To 25.0mm
Earth, Black, Brown, Yellow, Grey, Blue, Orange, Red, Violet, White: Earth, Black, Blue, Red, White
: Red, Black
2
2
2
2
2
Flexible Power Cables
A1 A6
Quick Reference
Lugs Page F1 & F4Gland Options F8, F9 & F10
Nor
mak
e
Flexible Power Cables
A1 A8
NoremakPVC Flexible Multi Core CablesOrdinary And Heavy DutyV90-HT
PartNo
PVC2C75OD**PVC3C75OD**PVC4C75OD**PVC5C75OD**
PVC2C01OD**PVC3C01OD**PVC4C01OD**PVC5C01OD**
PVC2C15OD**PVC3C15OD**PVC4C15OD**PVC5C15OD**
PVC3C25OD**PVC4C25OD**PVC5C25OD**
PVC3C04OD**PVC4C04OD**PVC5C04OD**
PartNo
PVC2C75HD**PVC3C75HD**PVC4C75HD**PVC5C75HD**
PVC2C01HD**PVC3C01HD**PVC4C01HD**PVC5C01HD**
PVC3C15HD**PVC4C15HD**PVC5C15HD**
PVC3C25HD**PVC4C25HD**PVC5C25HD**
PVC3C04HD**PVC4C04HD**PVC5C04HD**
No: of Cores&
mm square
2 x 0.753 x 0.754 x 0.755 x 0.75
2 x 1.03 x 1.04 x 1.05 x 1.0
2 x 1.53 x 1.54 x 1.55 x 1.5
3 x 2.54 x 2.55 x 1.5
3 x 4.04 x 4.05 x 4.0
No: of Cores&
mm square
2 x 0.753 x 0.754 x 0.755 x 0.75
2 x 1.03 x 1.04 x 1.05 x 1.0
3 x 1.54 x 1.55 x 1.5
3 x 2.54 x 2.55 x 1.5
3 x 4.04 x 4.05 x 4.0
o n lN mi ao era lv la mDi m
6.406 8. 0. 07 3
8 2. 0
6.707.007.808 6. 0
7 7. 0. 08 1
9.100.21 0
0.001. 011 0. 012 4
11.402.501
13.80
mNo inaloverall
Dia mm
. 08 28.809.70
10.70
08.59.00
10.00011.0
10.001 01 . 0
12.20
12.0013.0041 .40
013.915.3017.00
Stranding
24/0.2024/0.2024/0.2024/0.20
32/0.2032/0.2032/0.2032/0.20
30/0.2530/0.2530/0.2530/0.25
50/0.2550/0.2550/0.25
56/0.3056/0.3056/0.30
Stranding
24/0.2024/0.2024/0.2024/0.20
32/0.2032/0.2032/0.2032/0.20
30/0.2530/0.2530/0.25
50/0.2550/0.2550/0.25
56/0.3056/0.3056/0.30
InsulationThickness
0.60.60.60.6
0.60.60.60.6
0.70.70.70.7
0.80.80.8
0.80.80.8
InsulationThickness
1.301.401.501.60
1.301.401.501.60
1.601.701.80
1.801.902.00
1.902.002.20
OD Multi Core Flex 250V/440V
HD Multi Core Flex 0.6/1Kv
Available Colours
Black, Red, Orange, WhiteGrey Blue
Available Colours **Add To Part No
Black, Red, Orange, WhiteGrey Blue
Voltage Rating250/440V
Voltage Rating0.6/1Kv
StandardsAS3191
StandardsAS3191
Nor
mak
e
Flexible Power Cables
A9
Silicon Multi CoreFlexible Cables
Low Smoke Halogen Free
Cable Construction
* Low Smoke Halogen Free
* Tinned copper conductors, all Class 5 stranding.
* Silicon Insulation tear and heat resistant compound
Working Temperature
Rated Voltage
-60 C To +180 C
450/750V
Typical Uses
Electric Motor ApplicationsPower SuppliesMedical AreasRailway And Shipping
0 0
PartNo
777S0375777S0475777S0201777S0301777S0401777S0501777S0315777S0415777S0515777S0715777S1215777S1915777S0325777S0425777S0525777S0404777S0406
No: of Cores&
mm square
3 X 0.754 X 0.752 X 1.03 X 1.04 X 1.05 X 1.03 X 1.54 X 1.55 X 1.57 X 1.5
12 X 1.519 X 1.53 X 2.54 X 2.55 X 2.54 X 4.04 X 6.0
n lNomi aoverall
Di a mm
6.8087. 0
.6 6047. 0
.8 1088. 0
.8 00808.
.9 601 40. 04 01 .6
1 07. 0.9 70
1 60. 0.611 0
1 23. 05.1 60
Stranding
24/0.2024/0.2032/0.2032/0.2032/0.2032/0.2030/0.2530/0.2530/0.2530/0.2530/0.2530/0.2550/0.2550/0.2550/0.2556/0.3084/0.30
CableWeightKg/Km
76.0101.076.093.0113.0133.0117.0145.0175.0220.0413.0591.0179.0222.0268.0346.0497.0
OD Multi Core Flex 250V/440V
Nor
mak
eNBR Rubber Elastomer Insulated and Sheathed High Flex Power and Control CablesHeavy Duty 0.6/1kV Ordinary Duty 250/440V
Cable Construction*Conductors: annealed fine wires of plain electrolytic copper stranded for high flexibility.*Insulation of special flame retardant NBR Elastomer compound formulated for high flexibility & durable operation in extreme temperatures.*Separator or bedding of extruded or taped NBR material. Silicated powder lubricant between cores & inner sheath to reduce friction.*NBR Elastomer for outstanding flexibility & durability in most hostile environments.*UV Stabilised & fire retardant.
Temperature Range
-30 to +90 degree C static-20 to +90 degree C flexible
Bending Radius5 times diameter - fixed6 times diameter - flexible
Rated VoltageO.D HD.250/440V 0.6/1kV
Maximum Conductor Temperature
Relevant Standards
Applications
90 degree C
AS3147, AS3191, IEC227, IEC332.1
In machine tools, construction & engineering equipment, conveyors & other industrial application where outstanding flexibility is required under tough climatic & mechanical conditions. Diesel powered generator sets, load banks, ship to shore cables.
AS3008.1.1 1998 Table 13 Fixed, Table 15 FlexingPages 31, 34
PartNo
77700201OR77700301OR77700315OR77700325OR77700401OR77700415OR77700425OR77700525OR
No: of Cores
&mm square
2 x 1.03 x 1.03 x 1.53 x 2.54 x 1.04 x 1.54 x 2.55 x 2.5
m alNo ino rave ll
Dia mm
.867.48 4.0.1 0
8.09 2.11.212 5.
WeightKg/Km
7080
105160100130200240
Nominal Amps
Protected from Sun
1010152010152020
Nylon GlandPart No
NGM16NGM16NGM16NGM20NGM16NGM20NGM20NGM25
Stranding
32/0.2132/0.2148/0.2180/0.2132/0.2148/0.2180/0.2180/0.21
Metal GlandPart No
IP66
MG20-SMG20-SMG20-SMG20-SMG20-SMG20-SMG20MG20
OD Multi Core Flex Orange 250V/440V
IP68 Glands Also Available
Flexible Power Cables
A1 A10
Quick Reference
Current Capacities Page A21Gland Options F8, F9 & F10
Nor
mak
ePartNo
777003017770040177700501
7770031577700415777005157770071577701215
777003257770042577700525777007257770122577701825
7770020477700304777004047770050477700704
777003067770040677700506
777003107770041077700510
777003167770041677700516
No: of Cores
&mm square
3 x 1.04 x 1.05 x 1.0
3 x 1.54 x 1.55 x 1.57 x 1.5
12 x 1.5
3 x 2.54 x 2.55 x 2.57 x 2.5
12 x 2.518 x 2.5
2 x 43 x 44 x 45 x 47 x 4
3 x 64 x 65 x 6
3 x 104 x 105 x 10
3 x 164 x 165 x 16
NominalOverallDia mm
9.810.511.6
10.511.613.015.016.7
12.414.015.415.819.225.4
13.714.416.017.420.0
15.919.021.0
23.725.828.1
26.028.631.7
Weight Kg/Km
90100130
140170210268425
194239289365589785
275319394482600
406505619
8039751190
104012851590
NominalAmps
Protected fromSun
101010
1515151515
202020202020
2525252525
464646
636363
858585
Nylon GlandPart No
NGM20NGM20NGM20
NGM20NGM20NGM25NGM32NGM32
NGM25NGM25NGM25NGM25NGM32NGM40
NGM25NGM25NGM25NGM32NGM32
NGM25NGM32NGM32
NGM40NGM40NGM50
NGM40NGM50NGM50
Metal GlandPart No
IP66
MG20-SMG20-SMG20
MG20-SMG20MG20MG25MG25
MG20-SMG25MG25MG25MG25MG32
MG25MG25MG25MG25MG2
MG25MG32MG32
MG32MG32MG40
MG40MG40MG40
Stranding
32/0.2132/0.2132/0.21
48/0.2148/0.2148/0.2148/0.2148/0.21
80/0.2180/0.2180/0.8180/0.2180/0.2180/0.21
127/0.21127/0.21127/0.21127/0.21127/0.21
190/0.21190/0.21190/0.21
318/0.21318/0.21318/0.21
504/0.21504/0.21504/0.21
NBR Rubber Elastomer Insulated and Sheathed High Flex Power and Control CablesHeavy Duty 0.6/1kV Ordinary Duty 250/440V
Cable Technical Information Page A20, A21 & A22Gland Options F8, F9 & F10Voltage Drop Figures Page A22
Heavy Duty Multi Core Flex 0.6/1kV
IP68 Glands Also AvailableBlack Standard Orange Available On Request
Flexible Power Cables
A11
Nor
mak
eFlexible Submersible Harmonised Rubber Sheathed CablesVDE Approved
Cable Construction
Operating Temperature
Minimum Bending Radii
Properties
*Submersible to 100 Mtr
*Copper conductors [tinned up to 16 sq mm],acc.to VDE 0295, CLASS 5;*PETP-tape [only for sections above 16 sq,mm]*EPR rubber insulation type E14 acc. to HD22;*Elastomeric outer sheath type EM2 acc to HD222
*Minimum permissible ambient temperature - 40degrees Cel*Maximum permissible short circuit temperature250 degrees Cel*Minimum ambient temperature for optimum fullyflexible operations - 25 degrees C
The following minimum bending radius should be observed to ensure operating reliability.* For fixed installation - 4 x cable Diameter* When freely flexing - 5 x cable Diameter* For drag chains & reels - 10x cable Diameter
* Good tensile strength, tearing strength & abrasionresistance* Good elongation at breaks* Good dialectical properties * Acid resistant
Properties [cont]
Voltage Rating
Applications
Colour Code
* Oil resistant* Resistant to environmental factors like oxidation, ozone, sunlight* Flame retardant* Very good behavior to variations of outdoor temperature
* Rated Voltage UO/U = 0.6/1kv* Maximum operating voltages in: 3 phase AC Operation UO/U = 0.7/1.15kV DC operation UO/U=0.9/1.73kV * The cable is designated 450/750V with E14 insulation compound in accordance with VDE/IEC and meets or exceeds the Australian Standards AS3116 for the voltage rating of 0.6/1kV, R-EP-90
* For medium level mechanical loads, for use in dry & damp locations, for outdoor use or in locations subject to explosion hazards,* For industrial & workshop equipment* For connections of mobile machines & engines on construction sites,* As fixed installation, for example as installation on plaster in temporary buildings
* 2 conductors : Brown-Blue* 3 conductors : Brown-Blue-Green/Yellow* 4 conductors : Grey-Black-Brown-Green/Yellow* 5 conductors : Grey-Black-Brown-Blue-Green/Yellow
PartNo
77711275H0577711201H05777113G75H05777113G1H05777114G75H05
No Cores&
MM Square
2 x 0.752 x 1.0
3 x 0.753 x 1.0
4 x 0.75
Stranding
0.210.210.210.210.21
NominalOverall
Dia mm
6.47.17.08.58.8
WeightKg/Km
78949411490
Maximum Amps
Protected from Sun
1218121812
Nylon Gland
Part No
NGM16NGM16NGM16NGM16NGM16
Metal Gland IP66
MG20-16MG20-16MG20-16MG20-SMG20-S
Metal Gland IP68
MGS16MGS16MGS16MGS16MGS16
HO5RN-F 300/500v
Flexible Power Cables
A1 A12
Quick Reference
Current Capacities Page A21Gland Options Page F8, F9 And F10
Nor
mak
eFlexible Submersible Harmonised Rubber Sheathed CablesVDE Approved
PartNo
77711201777112157771122577711240777112607771121077711216
777113G1777113G15777113G25777113G4777113G6
777113G10777113G16
777113G025
777114G1777114G15777114G25777114G4777114G6
777114G10777114G16
777114G025777114G35777114G50777114G70777114G9577114G120
777115g1777115G15
777115G025777115G4777115G6
777115G10777115G16777115G25777115G35777115G50777115G70777115G95
777117G15777117G25777117G4777117G6
777117G10
777112G15777112G25
777118G15777118G25
7771127G157771127G257771137G15
No of cores& sizemm sq
2 x 1.02 x 1.52 x 2.52 x 4.02 x 6.0
2 x 10.02 x 16.0
3 x 1.03 x 1.53 x 2.53 x 4.03 x 6.0
3 x 10.03 x 16.03 x 25.0
4 x 1.04 x 1.54 x 2.54 x 4.04 x 6.0
4 x 10.04 x 16.04 x 25.04 x 35.04 x 50.04 x 70.04 x 95.0
4 x 120.0
5 x 1.05 x 1.55 x 2.55 x 4.05 x 6.0
5 x 10.05 x 16.05 x 25.05 x 35.05 x 50.05 x 70.05 x 95.0
7 x 1.57 x 2.57 x 4.07 x 6.07 x 10
12 x 1.512 x 2.5
18 x 1.518 x 2.5
27 x 1.527 x 2.537 x 1.5
Max Diaof Strands
mm
0.210.260.260.310.310.410.41
0.210.260.260.310.310.410.410.41
0.210.260.260.310.310.410.410.410.410.410.510.510.51
0.210.260.260.310.310.410.410.410.410.410.510.51
0.260.260.310.310.41
0.260.26
0.260.26
0.260.260.26
Overall Dia
9.49.411.513.014.519.522.0
9.1010.1012.014.015.521.024.029.0
10.011.5013.5015.5017.5023.026.032.035.040.045.051.056.0
11.512.515.017.019.025.029.035.039.045.050.056.6
16.018.5021.5024.8029.50
19.022.50
22.026.50
28.1033.5030.10
WeightKg/Km
100130190260350620850
125160230320425765
10601560
155200290400540930
1300195023303200420054907098
1902403505006701140161024402900400052506780
330470660956
1494
480690
6901010
110215211310
NylonGland
Part No
NGM16NGM16NGM20NGM25NGM25NGM32NGM32
NGM20NGM20NGM20NGM25NGM25NGM32NGM40NGM50
NGM20NGM20NGM25NGM25NGM32NGM40NGM40NGM50NGM63NGM63
---
NGM20NGM25NGM25NGM32NGM32NGM40NGM50NGM63NGM63
---
NGM25NGM32NGM32NGM40NGM50
NGM32NGM40
NGM32NGM40
NGM50NGM50NGM50
MetalGlandIP66
MG20-SMG20-SMG20MG25MG25MG32MG32
MG20-SMG20-SMG20MG25MG25MG32MG32MG40
MG20-SMG20MG25MG25MG25MG32MG40
MG50-SMG50-SMG50
MG63-SMG63MG63
MG20MG20MG25MG25MG25MG32MG40
MG50-SMG50
MG63SMG63
-
MG25MG25MG32MG32MG40
MG32MG32
MG32MG40
MG40MG50-SMG40
Metal GlandIP68
MGS20MGS20MGS20MGS25MGS25MGS32MGS40
MGS20MGS20MGS20MGS25MGS25MGS40MGS40MGS50
MGS20MGS20MGS25MGS25MGS32MGS40MGS40MGS50MGS63MGS63
--
MGS20MGS20MGS25MGS32MGS32MGS40MGS50MGS63MGS63
--
MGS32MGS32MGS40MGS40MGS50
MGS32MGS40
MGS40MGS40
MGS50MGS50MGS50
Max allowablecurrent under
permanent conditions40deg Cel
Amps
182434455778
105
182434455778
105140
16202838486688
120145180230285330
16202838486688
120145180230285
1318223141
1318
1318
131813
Flexible Power Cables
A13
HO7RN-F 0.6-1Kv
Nor
mak
eXLPE/NBR 90C 0.6/1KvScreened Flexible Variable Speed Drive Cable
Cable Construction
Insulation
Screening
Sheath
UV Stabilised and Flame Retardant
* Conductors of extra fine bare annealed copper wires.
XLPE 90 Deg C
Aluminium/Maylar tape plus tinned copper braid up to 4.0mm, above is tinned copper braid
Clear Sheath is TPE 1.5mm to 35.0mmBack Sheath NBR to 6.0mm and CPE10.0mm and above
Rated Voltage
Relevant Standards
Maximum Conductor Temperature
Colour
Bending Radius
0.6/1Kv
AS3147, IEC332-1
-30 to +90 degree C
Black / Clear To 35.0mmBlack Only Over 35.0mm
Fixed >20.0mm 7.5x diam<20.0mm 10x Cable diamFlexing>20.0mm 15xcable diam <20.0mm x 20 cable diam
PartNo
77780315SC77780325SC77780415SC77780425SC77780404SC77780406SC77780410SC77780416SC
777804025SC77780435SC77780450SC77780470SC77780495SC
777804120SC777804150SC77780525SC77780506SC
Amps Spaced
2434202838486688
1201451802302853303752848
EMC Compliant MetalGland
MG20EMCLMG25EMCLMG25EMCLMG25EMCLMG25EMCLMG32EMCLMG40EMCLMG40EMCLMG50EMCLMG50EMCLMG63EMCL
MG32EMCLMG40EMCL
CrossSectionalarea mm square
1.52.51.52.54.06.0
10.016.025.035.050.070.095.0
120.0150.0
2.56.0
EarthCores
1x1.51x2.51x1.51x2.51x4.03x1.53x1.53x2.53x4.03x6.0
3x10.03x10.03x16.03x16.03x25.01x2.51x6.0
PowerCores
2x1.52x2.53x1.53x2.53x4.03x6.0
3x10.03x16.03x25.03x35.03x50.03x70.03x95.0
3x120.03x150.0
4x2.54x6.0
Nominaloverall
Dia mm
12.513.513.514.516.519.521.523.528.532.040.043.348.751.358.518.721.0
WeightKg/Km
155195195245350445675955
1455220032113950512659257146533952
Please refer to Australian Standards for full conditions and notes which refer to this table
Please Refer to NoremakFor More Information On Larger Sizes And Options
AS 3008.1.1 1998 Table 13 Fixed Table 15 Flexing
Flexible Power Cables
A1 A14
Quick Reference
Current Capacities Page A21Gland Options Page F9
Nor
mak
eFlexible Control PVC/NBR 0.3/0.5kV
Cable Construction
Temperature Range
Rated Voltage
*Conductors annealed fine wires of plain electrolytic copper stranded for high flexibility.
PVC Insulated
Cores: white insulated with sequential black numbers, 1green/yellow
Protective sheath of flame retardant NBR Elastomer for outstanding flexibility & durability in most hostile environments.UV stabilised & flame retardant
Screening if applicable will be tinned copper braid. 85% minimum coverage. Suitable for protection against EMI Radiation
Static - 30 to + 80 degree CFlexing -5 to + 70 degree C
300/500 votls
Relevant Standards
Maximum Conductor Temperature
Bending Radius For flexing application:
Applications
VDE 0295 class 5 [ conductor] VDE 0812 [cores] IEC 332-1
90 degree C
15 times diameter unscreened20 times diameter screened
As power control or signal cables on machines, portable tools, conveying equipment & similar industrial applications.
PartNo
77720205777203057772040577720505777207057772120577721805777225057772300577724105
77720375777204757772057577720775777212757772187577722575
777203017772040177720501777207017772120177721801777225017772360177724101
777202157772031577720415777205157772071577721215777218157772191577722515777230157772371577725015
7772042577720725777212257772182577722725
No of Cores Section
mm square
2 x 0.53 x 0.54 x 0.55 x 0.57 x 0.5
12 x 0.518 x 0.525 x 0.530 x 0.541 x 0.5
3 x 0.754 x 0.755 x 0.757 x 0.75
12 x 0.7518 x 0.7525 x 0.75
3 x 1.04 x 1.05 x 1.07 x 1.0
12 x 1.018 x 1.025 x 1.036 x 1.041 x 1.0
2 x 1.53 x 1.54 x 1.55 x 1.57 x 1.5
12 x 1.518 x 1.519 x 1.525 x 1.530 x 1.537 x 1.550 x 1.5
4 x 2.57 x 2.5
12 x 2.518 x 2.527 x 2.5
Approx O.D. mm
4.85.15.76.67.09.411.112.413.316.6
6.06.27.17.6
10.612.214.3
6.06.57.68.011.113.415.418.218.8
8.56.78.39.19.7
13.416.216.519.520.522.026.0
11.013.017.521.025.0
Approx WeightKg/Km
3542546784
131192261304450
6688
100161247268465
6579
105131220315449620660
84117121144237393465542655750980
1224
192310524784900
Nylon Gland
NGM12NGM12NGM16NGM16NGM16NGM20NGM20NGM25NGM25NGM25
NGM16NGM16NGM16NGM16NGM20NGM25NGM25
NGM16NGM16NGM16NGM16NGM20NGM25NGM25NGM32NGM32
NGM16NGM16NGM16NGM20NGM20NGM25NGM25NGM32NGM32NGM32NGM40NGM40
NGM20NGM25NGM32NGM32NGM40
Metal GlandIP66
MG20-16MG20-16MG20-16MG20-16MG20-SMG20-SMG20MG20MG25MG25
MG20-16MG20-16MG20-16MG20-16MG20-SMG20MG25
MG20-16MG20-16MG20-16MG20-SMG20MG25MG25MG25MG25
MG20-SMG20-SMG20-SMG20-SMG20-SMG25MG25MG25MG32MG32MG32MG40
MG20MG25MG25MG32MG40
Flexible Power Cables
A15
Quick Reference
Current Capacities Page A20Multi Core Deratings A21
Gland Options Page F8, F9 And F10
Nor
mak
eFlexible Control PVC/PVC 0.3/0.5Kv
Cable Construction
Temperature Range
*Conductors annealed fine wires of plain electrolytic copper stranded for high flexibility.
*PVC Insulated
*Cores: Black insulated with sequential white numbers, Plus 1 green/yellow
*Protective sheath of flame retardant PVC for outstanding flexibility & durability in most hostile environments.
*UV stabilised & flame retardant
*Static - 30 to + 80 degree C*Flexing -5 to + 70 degree C
Relevant Standards
Maximum Conductor Temperature
Bending Radius For flexing application:
Applications
VDE 0295 class 5 [ conductor] VDE 0812 [cores] IEC 332-1
90 degree C
15 times diameter unscreened
As power control or signal cables on machines, portable tools, conveying equipment & similar industrial applications.
No of CoresSection
mm square
3 x 0.504 x 0.505 x 0.507 x 0.50
12 x 0.5018 x 0.5025 x 0.50
3 x 0.754 x 0.755 x 0.757 x 0.75
12 x 0.7518 x 0.7525 x 0.75
3 x 1.04 x 1.05 x 1.07 x 1.0
12 x 1.018 x 1.025 x 1.0
3 x 1.54 x 1.55 x 1.57 x 1.5
12 x 1.518 x 1.525 x 1.5
12 x 2.518 x 2.5
Part No
77720305P77720405P77720505P77720705P77721205P77721805P77722505P
77720375P77720475P77720575P77720775P77721275P77721875P77722575P
77720301P77720401P77720501P77720701P77721201P77721801P77722501P
77720315P77720415P77720515P77720715P77721215P77721815P77722515P
77721225P77721825P
Approx O.D. mm
5.15.76.26.78.9
10.512.5
5.76.26.77.310
11.813.8
6.06.57.18.0
10.512.714.7
6.77.28.19.012
14.417.0
17.521.0
Approx WeightKg/Km
42546381
131188261
556679
101171244337
657994
126205300408
84104128166279407560
445648
NylonGland
NGM12NGM16NGM16NGM16NGM16NGM20NGM20
NGM12NGM16NGM16NGM16NGM20NGM20NGM25
NGM16NGM16NGM16NGM16NGM20NGM25NGM25
NGM16NGM16NGM16NGM16NGM20NGM25NGM32
NGM32NGM32
Metal Gland IP66
MG20-16MG20-16MG20-16MG20-16MG20-SMG20-SMG20
MG20-16MG20-16MG20-16MG20-16MG20-SMG20MG25
MG20-16MG20-16MG20-16MG20-SMG20-SMG20MG25
MG20-16MG20-16MG20-SMG20-SMG20MG25MG25
MG25MG32
Flexible Power Cables
A1 A16
Quick Reference
Current Capacities Page A20Multi Core Deratings A21
Gland Options Page F8, F9 And F10
Nor
mak
eFlexible Control PVC Screened 0.3/0.5Kv
Cable Construction
Temperature Range
Rated Voltage
Conductor Stranding
*Fine wires Strands of bare copper wire, PVC core insulation, cores twisted in layers, black with consecutive numbering in white. One green yellow earth core. Outer sheath of PVC Compound
Static - 30 to + 70 degree CFlexing -5 to + 70 degree C
300/500 votlstest voltage 2000 V
Fine Wire to VDE0295 and IEC 60228
Part No
77720205SC77720305SC77720405SC77720505SC77720705SC77721205SC77721805SC77722505SC77723005SC
77720475SC77720575SC77720775SC77721275SC77721875SC77722575SC
77720301SC77720401SC77720501SC77720701SC77721201SC77721801SC77722501SC77723401SC77724101SC
77720215SC77720315SC77720415SC77720515SC77720715SC77721215SC77721815SC77722515SC77723415SC77725015SC
77720425SC77720725SC77721225SC
No of Cores Section mm
Square
2 x0.53 x 0.54 x 0.55 x 0.57 x 0.5
12 x 0.518 x 0.525 x 0.530 x 0.5
4 x 0.755 x 0.757 x 0.75
12 x 0.7518 x 0.7525 x 0.75
3 x 1.04 x 1.05 x 1.07 x 1.0
12 x 1.018 x 1.025 x 1.034 x 1.041 x 1.0
2 x 1.53 x 1.54 x 1.55 x 1.57 x 1.5
12 x 1.518 x 1.525 x 1.534 x 1.550 x 1.5
4 x 2.57 x 2.5
12 x 2.5
Approx O.D. mm
7.07.37.98.48.911.313.315.216.1
8.48.99.7
12.314.516.6
8.28.79.5
10.213.315.517.520.322.0
8.58.99.6
10.311.314.817.220.122.827.1
11.313.917.6
EMCCompliant
Gland
MG16EMCLMG16EMCLMG16EMCLMG16EMCLMG16EMCLMG20EMCLMG25EMCLMG25EMCLMG25EMCL
MG16EMCLMG16EMCLMG20EMCLMG20EMCLMG25EMCLMG25EMCL
MG16EMCLMG16EMCLMG20EMCLMG20EMCLMG25EMCLMG25EMCLMG32EMCLMG32EMCLMG40EMCL
MG16EMCLMG20EMCLMG20EMCLMG20EMCLMG20EMCLMG25EMCLMG32EMCLMG32EMCLMG40EMCLMG40EMCL
MG20EMCLMG25EMCLMG32EMCL
Flexible Power Cables
A17
Quick Reference
Current Capacities Page A20Multi Core De-ratings A21 Gland Options Page F9
Nor
mak
eFlexible Steel Braided Flexible Cable0.6/1kV
CABLE CONSTRUCTION
*Conductor fine wire strands of plain electrolytic copper wire for improved flexibility.
*Insulation made of NBR elastomer compound specially designed for resistance to migration & cold flexibility.
*Inner sheath of specially formulated PVC, resistant to migration & highly flexibile in sub-zero temperatures.
*Silicate powder lubricant between cores & inner sheath to reduce friction
TEMPERATURE RANGE:
RATED VOLTAGE
RELEVANT STANDARDS
BENDING RADIUS
APPLICATIONS
* - 30 TO + 90 Degree C static
* - 18 TO + 90 Degree C flexible
*0.6/1Kv
AS3147,IEC92-3,IEC92-353,IEC92-350,IEC332-3
15 X DIAMETER
As power, control or signal cable on inland waterway & sea-going vessels. On conveyors, machine tools, cranes, earth moving equipment & other industrial applications where extra mechanical protection is required. Also suitable for wiring in hazardous locations [i.e chemical plants]
PartNo
7777031577770415777705157777071577771215
777703257777042577770725
No of Cores xSection mm
square
3x1.54x1.55x1.57x1.5
12x1.5
3x2.54x2.57x2.5
Stranding
48/0.2148/0.2148/0.2148/0.2148/0.21
80/0.2180/0.2180/0.21
ApproxOuter Dia
mm
12.813.614.515.718.0
14.215.217.5
ApproxWeightKg/Km
220261271330504
260295448
Metal GlandSWA Type
MGSWA20-16MGSWA20-SMGSWA20-SMGSWA20MGSWA20
MGSWA20-SMGSWA20-SMGSWA20
Flexible Power Cables
A1 A18
Quick Reference
Current Capacities Page A21Gland Options Page F9-F10
Nor
mak
eParallel Twin Flexible Cable0.6/1kV
Cable Construction
*Conductors of fine strands of electrolytic copper wire for extra flexibility.
*Insulation of cores in red/black or Red/ Blue Aflex NBR elastomer
*Compound specially formulated for improved cold resistance.
*Sheathing of transparent PVC compound resistant to cold, abrasion, industrial oil and chemicals
*UV stabilised and flame retardant
Temperature Range:
Rated Voltage:
Relevant Standards:
Application:
*-30 to + 75 degrees C static -20 to +75 degrees C flexible
* 0.6/1Kv fixed wiring 450/750v for flexing
* VDE 0250, VDE472, AS3147, IEC 332-1
* Battery cable for use indoors and outdoors, in dry as well as wet locations on motorised vehicles, or battery powered equipment such as fork lifts, field conveyors etc. Also in high quality booster cables.
PartNo
777602257776020477760206777602107776021677760225777602357776025077760270
No Of Cores x mm Sq
2x 2.5mm2 x 4.0mm2 x 6.0mm
2 x 10.0mm2 x 16.0mm2 x 25.0mm2 x 35.0mm2 x 50.0mm2 x70.0mm
Stranding
80/0.21127/0.21190/0.21318/0.21504/0.21770/0.21
1083/0.211558/0.212204/0.21
ApproxOverallDia. mm
5.5x126.0x136.5x148.0x179.0x1911.0x2312.5x2614.5x3016.0x33
BootlacePins Uninsulated
Ferrules
PBL025PBL04PBL06PBL10PBL16PBL25PBL35PBL50PBL70
BellmouthLug
* Hole Size
CL025-*CL6-*
CL6-*BMCL10-*BMCL16-*BMCL25-*BMCL35-*BMCL50-*BMCL70-*BM
Flexible Power Cables
A19
Quick Reference
Current Capacities Page A21Gland Options Page F8, F9, F10
Nor
mak
eSubmersible EPR/PUR Flexible Cables
Construction
Insulation:
Outer Sheath;
Core Colour
* Copper Conductor: Flexible, tinned up to 16mmsq Flexible, bare from 25mmsq upwards [acc. to IEC 228 Class 5 resp. Class 6 for single -core cables]
EPDM, compound type Ei6 ass. to HD 22.1 S2* Filling sheath: Halogen-free filling compound [except single-core cables]
Halogen free polyurethane, compound type TMPU acc. to HD 22.10 S1* Screening if applicable will be tinned copper braid. Pilot cores will be 1.5 mmsq Sheath colour * Orange [similar to RAL 2003]
*2 core : brown, blue*3 Core : brown, blue green/yellow*4 Core : black, blue, brown, green/yellow*5 Core : black,blue brown,blackgreen/yellowFrom 7Core-: black with numbers,green-yellow
Test voltage
Temperature range
Special characteristics
* 300/500V : 2000 V,50 Hz, 5'* 0.6/1Kv : 2500 V,50 Hz, 5'
* -40 up to +90 degree Cel
* Extreme mechanical resistance [Abrasion-,tearing,-notch-,pressure & wear resistant]* Good reversed bending strength [min. 30000 reversed bendings under current acc. to VDE 0472, Part 603, Test H]* Good chemical resistance [against fuels, oils, grease, chemicals & sewage]* Resistant against enviromental factors[as ozone, UV, humidity, water]* Resistant against important temperature fluctuations* Flame retardant, halogen-free* Submersible down to 500m* Microbe & hydrolysis resistant
PartNo
777302757773021077733g7577733g1077734g7577734g1077735g7577735g10
No ofCores
x-sectionmm sq
2 x 0.752 x 1.0
3 x 0.753 x 1.0
4 x 0.754 x 1.0
5 x 0.755 x 1.0
MaxDia Wires
mm
0.210.210.210.210.210.210.210.21
Approx OverallDia mm
7.07.57.58.08.08.59.09.5
ApproxWeightKg/Km
6578789191
108113137
Maximum Amps
Protected from Sun
1218121812181218
NylonGland
Part No
NGM16NGM16NGM16NGM16NGM16NGM16NGM20NGM20
MetalGlandIP66
MG20-16MG20-16MG20-16MG20-SMG20-SMG20-SMG20-SMG20-S
MetalGlandIP68
MGS16MGS16MGS16MGS16MGS16MGS16MGS20MGS20
H05 BQ-F 300/500 V R-EP-90 Relvent Standard AS3191
HO5 BQ-F 300/500VAccording to CENELEC HD 22.10 S1
07 BQ-F AS3116 0.6/1KvAdapted to CENELEC HD22.10 S1
Flexible Power Cables
A1 A20
Quick Reference
Current Capacities Page A21Gland Options Page F8, F9, F10
Nor
mak
eSubmersible EPR/PUR Flexible Cables
PartNo
7773021577733G1577733G2577733G4
77734G1577734G2577734G477734G6
77735G1577735G2577735G477735G6
77735G1077735G16
77735G02577735G3577735G50
77737G1577737G25
No ofCores
x-sectionmm sq
2 x 1.53 x 1.53 x 2.53 x 4
4 x 1.54 x 2.54 x 44 x 6
5 x 1.55 x 2.55 x 45 x 6
5 x 105 x 165 x 255 x 355 x 50
7 x 1.57 x 2.5
MaxDia
Strandsmm
0.260.260.260.31
0.260.260.310.31
0.260.260.310.310.410.410.410.410.41
0.260.26
Approx OverallDia mm
9.09.511.013.0
10.512.514.014.0
11.513.516.018.023.126.533.538.043.5
14.016.5
ApproxWeightKg/Km
111130191266
162238331453
195291411559951
1351216929233945
291431
Maximum Amps
Protected from Sun
24243445
20283848
202838486688
120145180
1318
Nylon Gland
Part No
NGM16NGM20NGM20NGM25
NGM20NGM25NGM25NGM25
NGM20NGM25NGM25NGM32NGM40NGM40NGM50NGM63
-
NGM25NGM32
Metal GlandIP66
MG20-SMG20-SMG20MG20
MG20MG20MG25MG25
MG20MG25MG25MG25MG32MG40
MG50-SMG50MG50
MG25MG25
Metal Gland IP68
MGS20MGS20MGS20MGS25
MGS20MGS20MGS25MGS25
MGS20MGS25MGS32MGS32MGS40MGS40MGS50MGS63
-
MGS25MGS32
H07 BQ-F R-EP-90 Relevent Standard AS3191, AS3116 0.6/1Kv
HO5 BQ-F 300/500VAccording to CENELEC HD 22.10 S1
07 BQ-F AS3116 0.6/1KvAdapted to CENELEC HD22.10 S1
Flexible Power Cables
A21
Nor
mak
eTechnical Information
For Flexible Cables
Limiting Temperatures For Insulated Cables
Insulation Types
Thermoplastic
Elastomer
Cross Linked Polyethylene (XLPE)
Conductor Size mm
0.500.751.00
1.502.504.00
Conductor
Size mm
6.010.016.0
25.035.050.0
70.095.0
120.0
150.0185.0240.0*
446081
110135160
205240280
320360425
547499
135165195
250290340
390440510
344660
8095110
140160185
215240275
435877
105125145
185210245
280315365
Number Of Layers
1
2
3
4
Current Carrying Capacity Amps
3.0 (Conditions Apply)7.5
10.0
15.020.025.0
Derating Factor
0.76
0.58
0.47
0.40
Insulation Types
V-75 and HFI-75-TPV-90 and HFI-90-TP (AS 3008.1.1 For Conditions)
V90 HT (AS 3008.1.1 For Conditions)
R-EP-90, R-CPE-90, R-HF-90 and R-CSP-90R-HF-110 and R-E-110
X-90 and X-HF-90X-HF-110
Normal Use
757575
90110
90110
Flexible Power Cables
A1 A22
Max Permissible
7590
105
90110
90110
Operating Temperatures Of Conductors C
0
Current Carrying Capacities Of Flexible Cords Derating For Cords Wound On a Drum 0.5-4.0mm
2
2
Single And 2 Core
V75, V90
Single And 2 Core
R-EP-90R-CSP-90
Single And 2 Core
V75, V90
Single And 2 Core
R-EP-90R-CSP-90
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Current Carrying Capacities of 0.6/1 kV Flexible CablesProtected From Sun Exposed To Sun
Based On Ambient Air Temperature of 25 C0
2
Ratings and Capacities are based on Flexible Cables used In Flexing Applications and NOT Flexible Cables usedfor Fixed wiring applications. Refer to Australian Standards for these ratings AS 3008.1.1
S3
1 1
5A
00
8.1
.9
98
Ta
ble
1
S3
01
19
9T
6A
08
.1.
8
ab
le1
AS
30
08
.1.1
19
98
Ta
ble
1
Nor
mak
e
Flexible Power Cables
A23
Technical InformationFor Flexible Cables
Conductor
Size mm
6.010.016.0
25.035.050.0
70.095.0
120.0
150.0185.0240.0*
Conductor
Size mm
0.500.751.001.502.504.006.00
10.0016.0025.0035.00
385270
95115140
175205240
280315370
19242837506787
120165215265
466385
115140165
215250290
335380445
1520232838506790119160194
293951
688196
120140160
185205235
15202431435874
105140185230
375066
88105125
155180210
240270310
131619243242557699
135163
2
2
3 And 4 Core
V75, V90
3 And 4 Core
R-EP-90R-CSP-90
3 And 4 Core
V75, V90
3 And 4 Core
R-EP-90R-CSP-90
Exposed To SunProtected From Sun
Current Carrying Capacities of 0.6/1 kV Flexible Cables
Current Carrying Capacities of R-S-150 Flexible Cords
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Two Single Core Or One 2 CoreThree or Four Single Core
or 3 or 4 core
Number Of Cores
57
101419244061
Laying In air
0.750.650.550.500.450.400.350.30
Laying In Ground
0.700.600.500.450.400.350.300.25
AC Derating Factors For Multi Core Cables Greater Than 5 Core 1.5 To 10.0 mm
2
S3
1 1
5A
00
8.1
.9
98
Ta
ble
1S
1 1
7A
30
08
.1.
99
8 T
ab
le1
Nor
mak
eTechnical Information
For Flexible Cables
Flexible Power Cables
A1 A24
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
0.8 p.f
----------------
0.2740.2330.2030.1740.161
0.8 p.f
-----------–----
0.2490.2140.1880.1640.153
0.8 p.f
----------------
0.2660.2260.1980.1710.158
0.50.751.01.52.54.06.0
10.016.025.035.050.070.095.0
120.0150.0185.0240.0300.0400.0600.0
2 Conductor Temperature C Conductor Temperature C
Max
74.249.537.125.315.29.426.283.772.311.401.03
0.7810.5290.4250.3420.2830.2490.2140.1920.1730.165
Max
82.254.841.128.016.810.46.954.172.551.551.14
0.8620.5810.4650.3710.3050.2660.2260.2000.1780.168
Max
78.252.139.126.716.09.926.623.972.431.471.09
0.8220.5550.4450.3570.2940.2580.2200.1960.1750.166
Max
86.157.443.129.417.610.97.294.382.681.621.19
0.9020.6080.4850.3870.3170.2750.2330.2050.1800.170
0.8 p.f
----------------
0.2580.2200.1930.1680.156
45 60 75 90
Three Phase Voltage Drop At 50 Hz, mV/A.m0 0
Three-Phase Voltage Drop At 50 Hz Of Multicore Flexible Cables And CordsWith Copper Conductors
Conductor Size mm
49.733.224.917.010.26.314.212.521.54
0.9320.6840.5130.3400.2660.2070.1630.1350.106
0.08470.0648
45.130.122.615.49.235.733.822.291.40
0.8460.6210.4660.3090.2420.1880.1470.122
0.09550.07640.0583
45.130.122.615.49.235.733.822.291.40
0.8460.6210.4660.3090.2420.1880.1480.123
0.09650.07760.0598
Conductor Size mm
0.50.751.01.52.54.06.0
10.016.025.035.050.070.095.0
120.0150.0185.0240.0300.0400.0
2Conductor Temperature C Conductor Temperature C
42.828.621.414.68.765.443.622.171.33
0.8030.5890.4420.2930.2290.1780.1400.116
0.09090.07290.0558
42.828.621.414.68.765.443.622.171.33
0.8030.5890.4420.2930.2300.1790.1410.117
0.09190.07410.0573
47.431.623.716.29.706.024.012.411.47
0.8890.6520.4890.3240.2540.1970.1550.1280.100
0.08000.0609
47.431.623.716.29.706.024.012.411.47
0.8890.6520.4900.3250.2540.1980.1550.1290.1010.08110.0623
49.733.224.917.010.26.314.212.521.54
0.9320.6840.5130.3400.2660.2060.1620.1340.105
0.08360.0634
45 4560 6075 7590 90
Single Core Cables Multi Core Cables
0 0
AC Resistance At 50 Hz Of Flexible Cables And Cords With Copper Conductors
For AC Resistance Of Tinned Copper Conductors Multiply Copper Value By 1.01
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Nor
mak
e
Flexible Power Cables
A25
Technical InformationFor Flexible Cables
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Current Carrying Capacities of 3 Single Core 0.6/1 kV Flexible Cables R-EP-90 InsulationAs Per AS/NZS 3008.1.1:1998 Table 7
Single Double Insulated Cables InFixed Application
ConductorSize mm
11.52.546
10162535507095
120150185240300400
Spaced
192535465981110145180220280350410470550660770900
Spaced from
Surface
16213040506992
125155190240300350405470560650760
Touching
16202837476586115145175225280325375435520600700
Non-metallic wiring
enclosure in air
14182533425878110125155190230270310355420485560
Please refer to Australian Standards for full conditions and notes which refer to this table
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Nor
mak
eConductorSize mm
11.52.546
10162535507095
120150185240300400
Spaced
243143577399
130175220265340420490570660790910
1070
Spaced from
Surface
212738506386115155190230290365420485560670780910
Touching
202536475981
105145175215270340395455530630730850
Non-metallic wiring
enclosure in air
17223241517193
125150180235285335380450550630720
Current Carrying Capacities of 3 Single Core 0.6/1 kV Flexible Cables R-E-110 InsulationAs Per AS/NZS 3008.1.1:1998 Table 8
Single Double Insulated Cables InFixed Application
Please refer to Australian Standards for full conditions and notes which refer to this table
Technical InformationFor Flexible Cables
Flexible Power Cables
A1 A26
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Nor
mak
e
Flexible Power Cables
A27
Technical InformationFor Flexible Cables
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Application: Touching Mounted to Tray etc
ConductorSize mm
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
(1)V75, V90
13
16
23
31
40
54
72
97
120
145
185
230
265
310
355
425
490
570
(2)R-EP-90
16
20
28
37
47
65
86
115
145
175
225
280
325
375
435
520
600
700
(3)R-E-110
20
25
36
47
59
81
105
145
175
215
270
340
395
455
530
630
730
850
Please refer to Australian Standards for full conditions and information for the above ratings
Comparison of Current Ratings for Sheath Types As Per Australian Standards
Nor
mak
eThis catalogue only covers the standard range of cables supplied by Noremak Industries. Noremak can have cables manufactured custom cables for the Australian electronics industry with many of theseproducts being used locally and exported on a world wide
Noremak is capable of having products and cables manufactured to AS9002 and to Australian Standards including Austel, and can provide cables to UL approval for those cables involved in export manufacturing.
Noremak Industries has a close relationship with many cable manufacturesin Australia and overseas and is able to have special purpose cablesmanufactured to requirements and specialises in small run quantities.
These cables can be composed of any mixtures of conductors, pairs,coaxial cables and a variety of strength members and other elementsdepending on application
A few of examples which can be supplied
UNDER WATER VIDEO CAMERA CABLES
SEWER INSPECTION CABLES
MOBILE PHONE SYSTEM CABLES
DENTAL CABLES
METAL DETECTOR CABLES
Please contact Noremak Industries for your cable requirements for Power and Data applications. Noremak can have cables produced toyour requirements in surprisingly short runs and in surprisingly quickturn around times. We can also have leads and special applicationplugs manufacturing capabilities.
Noremak Industries Pty Ltd12 Princess Street
Beverley SA 5009Phone 08 8244 7288 Fax 08 8244 7299
email: [email protected]
Flexible Power Cables
A1 A28