10
SECTION 1: GENERAL DESCRIPTION (FIXTURE AND DRIVER) SECTION 2: CERTIFICATIONS MET Page 1 of 10 SECTION 3: LIGHT SOURCE DESCRIPTION (LED CHIP) SECTION 4: ENVIRONMENT SPEC LED UFO Highbay 00W 1) UL Listing : Underwriters Laboratory testing for dependable reliability and lifespan of fixture. 2) RoHS- Restriction of Hazardous Substances- Ensuring no toxic chemicals or materials are used in the manufacturing. 3) ISO 9001: Ensuring the manufacturer has the highest possible standards at the facility. 4) Food Grade Approved: Fixture is sealed, all parts double fastenened, ensuring safety for food manufacturing facilities,withstands heat. Model Number Voltage Power Leds Power Factor Light Output Beam Angle Correlated Colour Temperate (CCT) Fixture Lifespan Dimension Hue 300 Watts LUMILED SMD 3030 >0.9 45000 Lumens 105 Degrees 6000-6500K >50,000 Hours 400*174mm C/W VOL-UFO-300-CW AC 90-305V 1)LED Model 2)Number of LED 3)CRI SMD PHILIPS 3030 326 >80 4)POWER FACTOR 0.95 Operational Temperature Range Preservation Temperature Range Operational Humidity IP Rating Lifespan -40-55 Degrees Celcius 0-50 Degrees Celcius 95% RH or below (@-40 Degrees Celcius-55 Degrees Celcius) IP65 >50,000 hours

Upload: others

Post on 03-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SECTION 1: GENERAL DESCRIPTION (FIXTURE AND DRIVER)...Reflect2. 80 50 30 Lamp Probability Curve C Angle Range:0 - 180(Deg)

SECTION 1: GENERAL DESCRIPTION (FIXTURE AND DRIVER)

SECTION 2: CERTIFICATIONS MET

Page 1 of 10

SECTION 3: LIGHT SOURCE DESCRIPTION (LED CHIP)

SECTION 4: ENVIRONMENT SPEC

LED UFO Highbay 300W

1) UL Listing : Underwriters Laboratory testing for dependable reliability and lifespan of fixture.2) RoHS- Restriction of Hazardous Substances- Ensuring no toxic chemicals or materials are used in the manufacturing.3) ISO 9001: Ensuring the manufacturer has the highest possible standards at the facility.4) Food Grade Approved: Fixture is sealed, all parts double fastenened, ensuring safety for food manufacturing facilities,withstands heat.

Model NumberVoltagePowerLedsPower FactorLight OutputBeam AngleCorrelated Colour Temperate (CCT) Fixture LifespanDimension Hue

300 Watts LUMILED SMD 3030 >0.945000 Lumens 105 Degrees 6000-6500K>50,000 Hours 400*174mm C/W

VOL-UFO-300-CW AC 90-305V

1)LED Model2)Number of LED3)CRI

SMD PHILIPS 3030326 >80

4)POWER FACTOR 0.95

Operational Temperature RangePreservation Temperature RangeOperational HumidityIP RatingLifespan

-40-55 Degrees Celcius0-50 Degrees Celcius95% RH or below (@-40 Degrees Celcius-55 Degrees Celcius)IP65>50,000 hours

support3
Typewritten Text
Material
support3
Typewritten Text
AL + TG
support3
Typewritten Text
Page 2: SECTION 1: GENERAL DESCRIPTION (FIXTURE AND DRIVER)...Reflect2. 80 50 30 Lamp Probability Curve C Angle Range:0 - 180(Deg)

SECTION 5: COMPARABLE OLDER LIGHT SOURCE1000 Watt Metal Halide HighBay 300 Watt LED HighBay

1000 Watts of Power 300 Watts of Power8000 Hour Lifespan 50,000 Hour Lifespan

40% Lumen Depreciation after 1 Year 5% Lumen Depreciation after 1 Year2 Points of Failure (Ballast + Bulb) Does not use a Ballast

Carries no warranty Carries warrantyContains deadly mercury gas in Bulb RoHS certi ed for no toxic components

Takes 4-10 Minutes Start Up Time Instant StartTakes 6-15 Minutes Restrike Time Instant Restrike Time

Produces High Heat, Bulb can cause burns Slightly Warm to the Touch

Page 2 Of 10

Page 3: SECTION 1: GENERAL DESCRIPTION (FIXTURE AND DRIVER)...Reflect2. 80 50 30 Lamp Probability Curve C Angle Range:0 - 180(Deg)

Installation Manual

300W UFO LED Light

Option 3

• Pipe mounted

STEP 1.Fix the circular pipe to bracketSTEP 2.Fix screw on the ceillingSTEP 3.Connect circular pipe together with screw

Step 1

1

1

2

2

3

Step 2

White/blue cable for “ N ”

Black/Brown cable is for “ L ”

Green/Yellow for ground wire

※Note: If the lamp be used outside,please keep the connector water-proofIf the lamp be used outside,please keep the connector water-proof

N

L

Ground wireUS flex and plugEU flex and plug

Option 3

• Surface Mounted

Step 1 Step 2

Page 1 of 10

Page 4: SECTION 1: GENERAL DESCRIPTION (FIXTURE AND DRIVER)...Reflect2. 80 50 30 Lamp Probability Curve C Angle Range:0 - 180(Deg)

INTRODUCTION

INSTALLATION

SPECIFICATION

ACCESSORIES

• Aluminum alloy , super heat conductivity , good heat dissipation .

• Multiple power 300W .

• 3030 SMD LED Chip , High lumen 170lm/w .

• Waterproof IP65 , High thermal conductivity housing . Black and White

colour optional .

• Glass lens with transmittance up to 95% .

• Daylight sensor / Microware sensor + Dimmable available .

PRECAUTION

1.This lamp is UFO High Bay Light,and installation height is 12 feet above.Best operating environmental

temperature:0℃-30℃。

2.Avoid operating in the environments with strong magnetism,high voltage or thunder.

3.Wiring of the light should be firm and correct,to avoid fall-off accident or short circuit.

4.Clean the cover and heat sink of the high bay regularly,make sure its good heat dissipation.

5.Do not use highly corrosive solution to do the cleaning.Dry cleaning cloth is advise.

6.The device should be operated with the allowed input voltage only.

7.Switch off the power before connecting and wiring the device.

8.Installation of the light should be carried out by a qualified technician only.

9.Suitable for operation in ambient not exceeding 45℃。

APPLICATION:

Widely use in Workshop, Factory ,Warehouse, Stadium,Exhibition hall,Supermarket,Court,etc.

Power 300W

Input Voltage Range 90-305VAC/180-528VAC

Luminous Efficiency 170LM/W

Power Factor 0.95

Operating Temperature -49° F to 149°(-45°C to 65°)

Coolor Temperature 3000/ 4000K/ 5000K/ 6500K

Working Life-span 50000H

Protection Grade IP65

Warranty Three (3) Year

Power Cord Three Cord Cable

The color of the lamp shell Black/White Option 1

Option 2

• Suspended mounted

STEP 1.Fix hook on bracket STEP 2.Fix screw to the celling STEP 3.Connect chain to hook

Motion sensorAutomatic dimming when used in combination with 1-10V Built-in adjustable daylight sensor. widely use in warehouse area. Optional mounting brackets for different application.

360° CameraNetwork video playback and remote image capture,Support two-way voice intercom,Portable smart WIFI camcorder,1080P wide angle viewSupport Android and apple app software

Photocell dimmingProvide an energy saving without sacrificing visual comfort.With ambient light dependent control.Directly connected to 1-10V interface.Simple setting of the target light level by mean of potentiometer.

Step 1

1

2

3

Step 2

• Ceiling mounted

STEP 1.Fix the screw to the ceilingSTEP 2.Connect bracket together with scews on the ceilling

Step 1

1

2

Step 2

Page 5: SECTION 1: GENERAL DESCRIPTION (FIXTURE AND DRIVER)...Reflect2. 80 50 30 Lamp Probability Curve C Angle Range:0 - 180(Deg)

Lamp Photometric Data

300w UFO high bay

Measured Para U: 220.2V I: 1430.0mA P: 310.50W PF: 0.986 Test LM: 46790.04lm

Lamp Name: UFO high bay

Shape Size:

Sur(m^2):

Lamp Type: Normal Type

Lamp Spec: 300W

Manufactory:

Weight(kg): 7.0

Lamp ID:VOL-UFO-300-CW

Protect Angle(Deg): 105

Light Source Data Photometric Data

Model

Nominal P(w)

Rated Volt(v)

Rated Flux(lm)

Illuminant QTY

Peak Value(cd)

Total Flux(lm)

Dw Flux Rate(%) Down(C180-C360)

Efficiency(lm/w)

UP(C0-C180)

Down(C0-C180)

UP(C180-C360)

300W

1.0

1.0

45000.0

Planar Intensity Distribution Curve

1

18142.5

46790.037

100.0 47.2

150.7

0.0

52.8

0.0

Position 0.0,2.0

Up Flux Rate(%) 0.0

C0 Plane beam angle(50%):108.2 C90 Plane beam angle(50%):108.2

C0 Plane beam angle(50%)gfedcb C90 Plane beam angle(50%)gfedcb

0

30

60

90

120

150

180

210

240

270

300

330

18,140

14,512

10,884

7,256

3,628

0

C Angle Range:0 - 180(Deg)

Gama interval(Deg): 2 C interval(Deg): 45

Temperature(Deg): 26

Tester: TEST1

Test System: ZWL Goniophotometer System V3.0

Humidity(%): 52

Date: 2017-12-28

Gama Angle Range:-90 - 90(Deg)

Distance(m): 7.700 Remark:

Page 5 of 10

Page 6: SECTION 1: GENERAL DESCRIPTION (FIXTURE AND DRIVER)...Reflect2. 80 50 30 Lamp Probability Curve C Angle Range:0 - 180(Deg)

Lamp Photometric Data

Measured Para U: 220.2V I: 1430.0mA P: 310.50W PF: 0.986 Test LM: 46790.04lm

Lamp Name: UFO high bay

Shape Size:

Sur(m^2):

Lamp Type: Normal Type

Lamp Spec: 300W

Manufactory:

Weight(kg): 7.0

Lamp ID:VOL-UFO-300-CW

Protect Angle(Deg): 105

Imax=18142.5(cd)gfedcb

90% / 16328.3gfedcb

80% / 14514.0gfedcb

70% / 12699.8gfedcb

60% / 10885.5gfedcb

50% / 9071.3gfedcb

40% / 7257.0gfedcb

30% / 5442.8gfedcb

20% / 3628.5gfedcb

10% / 1814.3gfedcb

5% / 907.1gfedcb

Horizontal(DEG)9080706050403020100-10-20-30-40-50-60-70-80-90

Vertic

al(DEG)

90

80

70

60

50

40

30

20

10

0

-10

-20

-30

-40

-50

-60

-70

-80

-90

Planar IsoCandela Curve

C Angle Range:0 - 180(Deg)

Gama interval(Deg): 2 C interval(Deg): 45

Temperature(Deg): 26

Tester: TEST1

Test System: ZWL Goniophotometer System V3.0

Humidity(%): 52

Date: 2017-12-28

Gama Angle Range:-90 - 90(Deg)

Distance(m): 7.700 Remark:

Page 6 of 10

Page 7: SECTION 1: GENERAL DESCRIPTION (FIXTURE AND DRIVER)...Reflect2. 80 50 30 Lamp Probability Curve C Angle Range:0 - 180(Deg)

Lamp Photometric Data

Measured Para U: 220.2V I: 1430.0mA P: 310.50W PF: 0.986 Test LM: 46790.04lm

Lamp Name: UFO high bay

Shape Size:

Sur(m^2):

Lamp Type: Normal Type

Lamp Spec: 300W

Manufactory:

Weight(kg): 7.0

Lamp ID: VOL-UFO-300-CW

Protect Angle(Deg): 105

MH(m)

S(M)

10.0

14.0

18.0

22.0

26.0

30.0

34.0

38.0

42.0

46.0

50.040.0

9.1( 5%)18.1(10%)36.3(20%)54.4(30%)72.6(40%)

90.7(50%)108.9(60%)127.0(70%)145.1(80%)163.3(90%)

Spacial ISOLUX Curve Planar ISOLUX Curve

90

80

70

60

50

40

30

20

10

S(m) C(DEG)

0

0

1

2

3

907.1( 5%)1814.3(10%)3628.5(20%)5442.8(30%)7257.0(40%)

9071.3(50%)10885.5(60%)12699.8(70%)14514.0(80%)16328.3(90%)

C Angle Range:0 - 180(Deg)

Gama interval(Deg): 2 C interval(Deg): 45

Temperature(Deg): 26

Tester: TEST1

Test System: ZWL Goniophotometer System V3.0

Humidity(%): 52

Date: 2017-12-28

Gama Angle Range:-90 - 90(Deg)

Distance(m): 7.700 Remark:

Page 7 of 10

Page 8: SECTION 1: GENERAL DESCRIPTION (FIXTURE AND DRIVER)...Reflect2. 80 50 30 Lamp Probability Curve C Angle Range:0 - 180(Deg)

Lamp Photometric Data

Measured Para U: 220.2V I: 1430.0mA P: 310.50W PF: 0.986 Test LM: 46790.04lm

Lamp Name: UFO high bay

Shape Size:

Sur(m^2):

Lamp Type: Normal Type

Lamp Spec: 300W

Manufactory:

Weight(kg): 7.0

Lamp ID:VOL-UFO-300-CW

Protect Angle(Deg): 105

Aver Luminance(cd/m*m) Gm(Deg) C0 C90

45 50 55 60 65 70 75 80 85

GlareGlare Class Illuminance(lx) 1.15 A 2000 1000 500 <=300 1.5 B 2000 1000 500 <=300 1.85 C 2000 1000 500 <=300 2.2 D 2000 1000 500 <=300 2.55 E 2000 1000 500 <=300

a b c d e f g h

Luminance Limit CurveGama(Deg)85

75

65

55

458 41000 2 3 4 5 6 8 10000 2 3

a b c d e f g h

C0/180 C90/270 Aver Luminance(cd/m*m)

108106.3 91804.3 72868.9 59168.2 44847.0 23924.3 9727.6 4126.1 1072.6108316.3 91650.8 72497.3 58546.2 44199.1 23193.2 9389.1 3893.5 998.3

Luminance Limit Curve

C Angle Range:0 - 180(Deg)

Gama interval(Deg): 2 C interval(Deg): 45

Temperature(Deg): 26

Tester: TEST1

Test System: ZWL Goniophotometer System V3.0

Humidity(%): 52

Date: 2017-12-28

Gama Angle Range:-90 - 90(Deg)

Distance(m): 7.700 Remark:

Page 8 of 10

Page 9: SECTION 1: GENERAL DESCRIPTION (FIXTURE AND DRIVER)...Reflect2. 80 50 30 Lamp Probability Curve C Angle Range:0 - 180(Deg)

Lamp Photometric Data

Measured Para U: 220.2V I: 1430.0mA P: 310.50W PF: 0.986 Test LM: 46790.04lm

Lamp Name: UFO high bay

Shape Size:

Sur(m^2):

Lamp Type: Normal Type

Lamp Spec: 300W

Manufactory:

Weight(kg): 7.0

Lamp ID:VOL-UFO-300-CW

Protect Angle(Deg): 105

1m276.29cm5934.59/ 18142.52Lx Ec=18053.34Lx

2m552.58cm1483.65/ 4535.63Lx Ec=4513.33Lx

3m828.87cm659.40/ 2015.84Lx Ec=2005.93Lx

4m1105.16cm370.91/ 1133.91Lx Ec=1128.33Lx

5m1381.45cm237.38/ 725.70Lx Ec=722.13Lx

Height Eavg/Emax Plane beam angle:108.2 Deg Spot Diameter

output lm: 35580.17lm

Average Illumination

C Angle Range:0 - 180(Deg)

Gama interval(Deg): 2 C interval(Deg): 45

Temperature(Deg): 26

Tester: TEST1

Test System: ZWL Goniophotometer System V3.0

Humidity(%): 52

Date: 2017-12-28

Gama Angle Range:-90 - 90(Deg)

Distance(m): 7.700 Remark:

Page 9 of 10

Page 10: SECTION 1: GENERAL DESCRIPTION (FIXTURE AND DRIVER)...Reflect2. 80 50 30 Lamp Probability Curve C Angle Range:0 - 180(Deg)

Lamp Photometric Data

Measured Para U: 220.2V I: 1430.0mA P: 310.50W PF: 0.986 Test LM: 46790.04lm

Lamp Name: UFO high bay

Shape Size:

Sur(m^2):

Lamp Type: Normal Type

Lamp Spec: 300W

Manufactory:

Weight(kg): 7.0

Lamp ID:VOL-UFO-300-CW

Protect Angle(Deg): 105

10 20 30 40 50 70 100 200 300 500 700 1K 2K 3K 4K 5K 7KArea(m*m)

1

2

3

4

5

6

7

8910

20

30

40

50

Num(N)

Lamp Probability Curve

Flux(lm) 46790.0

Factor(MF) 0.7

Aver Lux(lx) 100

Hwork(M) 0

CeilingWall Floor

Reflect1. 80 50 30

Reflect2. 80 50 30

Lamp Probability Curve

C Angle Range:0 - 180(Deg)

Gama interval(Deg): 2 C interval(Deg): 45

Temperature(Deg): 26

Tester: TEST1

Test System: ZWL Goniophotometer System V3.0

Humidity(%): 52

Date: 2017-12-28

Gama Angle Range:-90 - 90(Deg)