Schneider Electric 1- Division - Name – Date
Schneider Electric Pre Fabricated Modular Data Center Overview & Discussion
Schneider Electric 2- Division - Name – Date
Schneider Electric is the Global Leader inPre Fabricated Modular Solutions
AST leads the pre-fabricated Modular Data Center Market (>20% market share)Over 600 Data Center projects successfully executed to dateProjects deployed in over 50 countriesFirst company to build a Tier 3 multi-Container Data CenterPioneered the manufacturing of high quality purpose built containerized data centers (2001)AST customers include IT leaders including IBM, HP, Dell, and Silicon Graphics
In January 2014 Schneider Electric acquired AST Modular the global leader in pre fabricated modular and containerized and modular Data Centers
Schneider Electric 3- Division - Name – Date
Schneider Has Deep Experience in Delivering Pre Fabricated Solutions
Schneider Electric 4- Division - Name – Date
Product Options
Schneider Electric 5- Division - Name – Date
SS Modular Rooms
Our Products Include a Wide Variety of Standard and Pre-fabricated IT Room Solutions
SS Standard ISO MDC – Non-ISO
20’ & 40’ ISO-All in one containers-Multi container parks
25’ & 45’ NON ISO-All in one modules-Contiguous IT rooms
Secure IT rooms -Indoor & Out Door -Secure and any size
Smart Shelter
Schneider Electric 6- Division - Name – Date
Compact ISO All-in-One (20ft Enclosure,7Racks, UPS, PDU, Overhead DX Cooling,
Standard ISO All-in-One (40ft Enclosure, up to 19 racks, PDU, overhead DX cooling
Ruggedized Solutions for Industrial (40ft Enclosure, up to 19 racks, PDU, overhead DX cooling, Ruggedized versions available
Multi-Bay IT Modules (25ft – 40ft enclosure, Non-ISO design for more space. Cooling options - In-Row CW Perimeter CW, Air Economizer Cooling, DCIM)
Modular Room (20 x 45ft Enclosure,24 Racks, PDU, 3 Perimeter CRACs CW cooling, DCIM)
AST IT Modules
3 Types of IT Modules for Different Applications
Schneider Electric 7- Division - Name – Date 7
Non-ISO design is wider, taller, deeper than container and engineered to provide a spacious, functional workspace for IT personnel
Efficient, scalable design allows for custom, multi-module configurations from 20 – 240 racks
Multiple cooling solutions for chilled water, DX and air economization (In-row, Perimeter, End-of-Row)
Robust frame design simplifies installation and ganging together
Best option for a complete configurable space.
IT Module – Non ISO ”Wide Tall & Comfortable”
Overview
Walk Through Our Demo Module Outside
Schneider Electric 8- Division - Name – Date
Multi Module Designs
IT Rooms are joined together to form an “open white space” IT room
Schneider Electric 9- Division - Name – Date
90kW All-in-One (40ft Enclosure,10 Racks, UPS, PDU, In-Row DX Cooling, DCIM)
110kW Single Module (40ft Enclosure, 10 racks, PDU, In-Row CW cooling, DCIM)
205kW Single Module (53ft Enclosure,14
racks, PDU, In-Row CW cooling, DCIM)
240kW Dual Module
(20 x 45ft Enclosure 22 Racks, PDU, In-Row
CW cooling, DCIM)
240kW Dual Module (20 x 45ft Enclosure,24 Racks, PDU, 3 Perimeter CRACs CW cooling, DCIM)
IT Room Modules
Base Designs – IT Modules
Schneider Electric 10- Division - Name – Date
90 kW All in One Pre Fabricated Data Center (Non ISO)
Schneider Electric 11- Division - Name – Date
10 Rack 90 kW N+1 “All in One” Wide Body” Pre Fabricated Data Center
Schneider Electric 12- Division - Name – Date
24 NetShelter Racks
240kW cooling capacity 415V distribution
@11kW per rack (2N) Power monitoring,
management and controls
Fire detection and suppression
Staging lobby for outside isolation In-Row
Cooling Units
Aisle Containment
415 Modular Power
Distribution
Staging Lobby and Electrical
Room
2 bay, 24 Rack In-Row, 240kW shown
IT Module Detail
Schneider Electric 13- Division - Name – Date
25’ 5 rack 30 kW N+1 “All in One”
Schneider Electric 14- Division - Name – Date
20’ 3 rack 30 kW N+1 Data Comm Room
Schneider Electric 15- Division - Name – Date
Smart Shelter™ Prefab Modular Room Example Phased Deployment View of (4)100 Rack IT Bays
Phase 1 100 Racks
Phase 2100 Racks
Phase 3
Phase 4
Gensets Chillers
Schneider Electric 16- Division - Name – Date
● Expandable rooms are secure, water, dust & fire proof thermally insulated modular IT rooms.
● Rooms are built sized to any requirement.
● Installed Indoors or outdoor.● Shelters can be disassembled &
relocated.● Rooms can expanded in a clean method.● No construction construction dust or
debris affecting expansion while operating.
● Visiting customers experience a “clean room” secure IT white space.
Smart Shelter™ Secure Prefab Modular Rooms
Schneider Electric 17- Division - Name – Date
Sliding Rail System
Seismic Rack Mount
Echain cable managemen
t
IT Module – ISO Shipping Container
Schneider specific features
Schneider Electric 18- Division - Name – Date
250kW 20ft Enclosure with UPS, Switchgear, cooling, DCIM
500kW 40ft Enclosure with UPS, Switchgear, cooling, DCIM
1.2 MW Skid mounted, UPS, Switchgear, DCIM
Power Modules
Base Designs - Power Modules
Schneider Electric 19- Division - Name – Date
Critical Output
Switchboard
Air Conditioners
500kW Symmetra
PX UPS
Primary Switchboard
Fire Suppression System
Symmetra N+1 UPS(250/500kW)
5 min Runtime Switchboard w/ integrated
ATS Power monitoring,
management and controls Environmental cooling Fire Suppression UL Listed
500kW Module
Enclosed Power Modules
Schneider Electric 20- Division - Name – Date
1.2 MW Skid Shown
Allows for quick deployment within an existing building that is scalable for larger data centers.
N+1 UPS MW UPS 5 min Runtime Switchboard w/ integrated ATS Power monitoring, management and controls
Skid Mounted Power Module
Schneider Electric 21- Division - Name – Date
500kW Hydronics Modules (Support 3-250kW Chillers)
1000kW Hydronics Modules (Support 3-500kW Chillers)
Chiller Skids & Enclosures Packaged Chiller, pump, and Tank with connecting piping
250kW – 1.2 MW Packaged Air Cooled Chillers - Options with and without free cooling
Ecobreeze ISO frame 50kW increments up to 400kW of total cooling capacity (DCIM)
Cooling Modules
Cooling Modules
Schneider Electric 22- Division - Name – Date
AST Cooling Offer – CW & DX (Pending UL Certification)
AST added Capability
Chilled Water Block Unit – CWB 100 kW
Chilled water room cooling for prefabricated IT modules without raised floors
● Fits both ISO and Non-ISO prefab modules● Designed to operate at higher water temperatures (15C)● Top return with front supply air discharge● Humidifier and electric reheat control options
Hot Corridor Heat Exchanger– HCX 20 kW - 40 kW
Overhead cooling for prefabricated ISO IT modules
● Chilled Water or Direct Expansion● No floor space - located over the racks and hot aisle/corridor● Maintenance all done from hot aisle/corridor● Requires chilled water plant or remote condensing unit
Schneider Electric 23- Division - Name – Date
AST Cooling Offer – Air Economizer
Natural Free Cooling Unit – NFC 50 kWIndirect Free Cooling for small or constrained data center spaces
● Independent operating unit● Heat Pipe heat exchanger isolating indoor and outdoor air● Chilled Water, Direct Expansion, Humidity Control and Evaporative Cooling
Options● Flexibility to have external heat rejection for mechanical cooling as required
- Chilled Water Plant or External Condensing Units
Direct Free Cooling Unit – DFC 75 kWDirect Free Cooling for small or constrained data center spaces
● Uses air directly from outside for free cooling● Chilled Water, Direct Expansion, Humidity Control and Evaporative Cooling
Options● Flexibility to have external heat rejection for mechanical cooling as required
- Chilled Water Plant or External Condensing Units
Schneider Electric 24- Division - Name – Date
Utility - Australia
Healthcare - Italy Military - Europe
Education - Canada
Global References
Schneider Electric 25- Division - Name – Date
IT Software Company Government Customer – US
Global Bank – Denmark Cloud Service Provider – Iceland
Global References
Schneider Electric 26- Division - Name – Date
Mission-Critical Services
● Consulting and Planning – Assessment, analysis, strategic planning and O&M program development services.
● Design and Construction– Engineering, design-build and construction project management of facility expansions and new facility projects.
● Commissioning – Data center and LEED commissioning from project inception to integrating testing.
● Operations and Maintenance – Managed Services and on-site Critical Facility Management.
● Energy Management– Energy assessments, system optimization, and efficiency improvement projects.
● Alarm and Incident Management – 24x7 remote monitoring services through the Schneider International Operations Center (NOC).
Lifecycle Service Solutions
Schneider Electric 27- Division - Name – Date
Design-Build Benefits
2/2012 12/2013 Schneider Design Build Outcomes
Singular Accountability/Project Ownership
Fully Integrated Project Delivery
Speed to Market – Reduced Project Timelines
Fewer Change Orders – Less Cost Overruns
Continuous Project Budgeting and Scheduling
Datacenter/Mission Critical Specific Team Skill Set
Competitively Bid All Major Cost Items
28
Discussion, Questions and Answers
Scott FlemingPre Fabricated Data Center [email protected](925) 963 5468
Thank you
Schneider Electric 29- Division - Name – Date 29
ISO shipping container is defined to 8ft wide and lengths of 10ft, 20ft, 40ft, and 53ft in U.S.
Containers are designed to be strong, rugged, environmentally sound and easily transportable anywhere in the world
8ft width limits usable space for hot and cold aisles. Height is also limited
Schneider has unique solutions for slide racks and flexible cable trays to allow full access to front and rear of racks to overcome space limitations
Overhead cooling units (DX and CW) are available to maximize rack space
IT Module – ISO Shipping Container
Overview
Schneider Electric 30- Division - Name – Date
Pow
erIT
Spa
ceC
oolin
gOne-Size Does Not Fit All
200kW – 1.2MW
5 Racks – 200 Racks
DX – Chilled Water – Direct Air – Indirect Air