Page 1: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS

Page 2: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

Pri. 115V

12

LINES

# 6# 2

# 5 # 1

# 2

AC

-

+

AC

Revised May, 2010

INDEX# 1 Up Contactor# 2 Down Contactor

Push Button

DownUp

AdjustableLimit Switch

# 1Contactor

Coils # 2

TransformerSec. 24V

# 1

# 4

# 8

# 4

# 3# 2

HoistMotor

115 Volts

BRAKE 24 V DC

# A401

# 1# 3

VULCAN ELECTRIC HOIST115 Volts 1 phase 60 Hz

24 Volt Controls Motor 115 or 230 Volts

Green Ground

FUSE

FUSE

Page 3: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

Revised May 2010

INDEX# 1 Up Contactor# 2 Down Contactor

# F501

Pri. 230V

BRAKE 24 V DC

# 6# 4

# 5 # 1

# 2

AC

-

+

AC

Push Button

DownUp

AdjustableLimit Switch

# 1Contactor

Coils # 2

TransformerSec. 24V

# 1

# 4

# 3# 2

HoistMotor

230 Volts

LINES# 8

# 1# 2

# 3

12

VULCAN ELECTRIC HOIST230Volts 1 phase 60 Hz

24 Volt Controls Motor 115 or 230 Volts

Green Ground

FUSE

FUSE

Page 4: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

Pri. 230V

12

LINES

# 5# 4

# 8 # 2

# 1

AC

-

+

AC

Revised May 2010

INDEX# 1 Up Contactor# 2 Down Contactor

Push Button

DownUp

AdjustableLimit Switch

# 1Contactor

Coils # 2

TransformerSec. 24V

# 1

# 4

# 6

# 3# 2

HoistMotor

230 Volts2HP Only

BRAKE 24 V DC

# F502

# 1

VULCAN ELECTRIC HOIST230 Volts 1 phase 60 Hz

24 Volt Controls 2 HP Motor 230 Volts Only

Green Ground

NC

NC

FUSE

FUSE

Page 5: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

VULCAN ELECTRIC HOIST230 Volts 3 phase 60 Hz

24 Volt Controls

Pri. 230V

123

LINES

# 1# 2

# 3 # 1

# 2

AC

-

+

AC

INDEX# 1 Up Contactor# 2 Down Contactor

Push Button

DownUp

AdjustableLimit Switch

# 1Contactor

Coils # 2

TransformerSec. 24V

# 1

# 2

# 4# 5# 6

# 7# 8

# 9

# 3# 4

HoistMotor

230 Volts

BRAKE 24 V DC

# H301

Green Ground

FUSE

FUSE

Revised April 2010

Page 6: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

Revised October 23rd, 2002

INDEX# 1 Up Contactor# 2 Down Contactor

VULCAN ELECTRIC HOIST460 Volts 3 phase 60 Hz

24 Volt Controls

# T201

Green Ground

Pri. 460V

BRAKE 24 V DC

123

# 1# 2

# 3 # 1

# 2

AC

-

+

AC

Push Button

DownUp

AdjustableLimit Switch

# 1Contactor

Coils # 2

TransformerSec. 24V

# 1

# 4

# 4# 7# 5

# 3# 2

# 8# 6

# 9

HoistMotor

460 VoltsLINES

FUSE

FUSE

Page 7: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

VULCAN ELECTRIC HOIST575 Volts 3 phase 60 Hz

24 Volt Controls

Revised May, 2010

INDEX# 1 Up Contactor# 2 Down Contactor

# V101

Green Ground

Pri. 575V

HoistMotor

575 Volts

BRAKE 24 V DC

123

LINES

# 1# 2# 3 # 1

# 2AC

-

+

AC

Push Button

DownUp

AdjustableLimit Switch

# 1Contactor

Coils # 2

TransformerSec. 24V

FUSE

FUSE

Page 8: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

VULCAN ELECTRIC HOIST 2 SPEEDS230 Volts 3 phase 60 Hz

24 Volt Controls

# H309

# 1 Up Contactor# 2 Down Contactor# 3 HS Contactor

INDEX

321+AC

- AC

Sec. 24VTransformerPri. 230V

# 3 N.O.N.O.N.O.# 2N.O.# 1

# 1# 2

# 3# 11

# 12# 13

LINES

HoistMotor

230 Volts

Green Ground 4

BRAKE 24 V DCCommon coils

HSCoil# 3

# 2Contactor

Coils# 1

AdjustableLimit SwitchUp Down

Push ButtonTwo ButtonTwo Speed

Fuse

Fuse

Down

Up

High Speed

Revised April 2010

Page 9: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

VULCAN ELECTRIC HOIST 2 SPEEDS460 Volts 3 phase 60 Hz

24 Volt Controls

Revised april 10, 2010

321

4

+AC

- AC

Sec. 24VTransformerPri. 460V

# 3 N.O.N.O.N.O.# 2N.O.# 1

# 1# 2

# 3# 11

# 12# 13

LINES

# 1 Up Contactor# 2 Down Contactor# 3 HS Contactor

INDEX

HoistMotor

460 Volts

Green Ground

# T209

BRAKE 24 V DCCommon coils

HSCoil# 3

# 2Contactor

Coils# 1

AdjustableLimit SwitchUp Down

FUSE

FUSE

Push ButtonTwo ButtonsTwo Speeds

Down

Up

High Speed

Page 10: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

VULCAN ELECTRIC HOIST 2 SPEEDS575 Volts 3 phase 60 Hz

24 Volt Controls

Revised May, 2010

# V109

321

4Green Ground

+AC

- AC

Sec. 24VTransformerPri. 575V

# 3 N.O.N.O.N.O.# 2N.O.# 1

# 1

HoistMotor

575 Volts# 2

# 3# 11

# 12# 13

LINES

# 1 Up Contactor# 2 Down Contactor# 3 HS Contactor

INDEXPush ButtonTwo ButtonsTwo Speeds

BRAKE 24 V DCCommon coils

HSCoil# 3

# 2Contactor

Coils# 1

AdjustableLimit SwitchUp Down

Down

Up High Speed

FUSE

FUSE

Page 11: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

Sec. 24V

INDEX# 1 Left Contactor# 2 Right Contactor# 3 Thermal Overload# 4 Terminal Block# 5 Main Line Contactor

Revised April 2010

#H327

Green Ground

TrolleyMotor

230 Volts

# 1 # 2 # 3N.O. N.C.

Line # 1Line # 2Line # 3

# 1 # 2

ContactorCoils

# 1 # 2 # 3

Left Right

# 7# 6 # 4

CONNECT CABLE FROM HOIST NUMBER TO NUMBER

# 5

# 1 # 2 # 3 # 4 # 5

Push Button

Stop

Right

Left

Down

Up

Main LineContactor Coil

Pri. 230VTransformer

VULCAN ELECTRIC TROLLEY WITH THERMAL OVERLOADTO CONNECT WITH VULCAN ELECTRIC HOIST

230 Volts 3 phase 60 Hz24 Volt Controls

See Diagram # H327A

#5

#4#5#6

#7 #8 #9

Fuse

Fuse

Page 12: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

Pri. 230V

123

# 1# 2

# 3 # 1

# 2

AC

-

+

AC

VULCAN ELECTRIC HOISTTO CONNECT WITH VULCAN ELECTRIC TROLLEY

230 Volts 3 phase 60 Hz24 Volt Controls

Emergency stop, Push button in trolleySee diagram #H327

Revised April 2010

INDEX# 1 Up Contactor# 2 Down Contactor

DownUp

AdjustableLimit Switch

# 1Contactor

Coils # 2

TransformerSec. 24V

# 1

# 2

# 4# 5# 6

# 7# 8

# 9

# 3# 4

HoistMotor

230 Volts

456

Green Ground 7

White black stripeOrange

BlueRed

WhiteBlack

Blue # 4Orange # 5

# H327A

BRAKE 24 V DC

CABLE TOTROLLEY

Fuse

Fuse

Page 13: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

Revised April, 2010

INDEX# 1 Up Contactor# 2 Down Contactor

VULCAN ELECTRIC HOISTTO CONNECT WITH VULCAN ELECTRIC TROLLEY

460 Volts 3 phase 60 Hz24 Volt Control

Emergency stop, Push button in trolleySee diagram #T227A

# T227

CABLE TOTROLLEY

Pri. 460V

BRAKE 24 V DC

123

# 1# 2

# 3 # 1

# 2

AC

-

+

AC

DownUp

AdjustableLimit Switch

# 1Contactor

Coils # 2

TransformerSec. 24V

# 1

# 4

# 4# 7# 5

# 3# 2

# 8# 6

# 9

HoistMotor

460 Volts

Green Ground 7

456

BlackWhiteRedBlue

OrangeWhite black stripe

Blue # 4Orange # 5

FUSE

FUSE

Page 14: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

Revised May, 2010

INDEX# 1 Up Contactor# 2 Down Contactor

VULCAN ELECTRIC HOISTTO CONNECT WITH VULCAN ELECTRIC TROLLEY

575 Volts 3 phase 60 Hz24 Volt Controls

Emergency stop, Push button in trolley

# V127

CABLE TOTROLLEY

Pri. 575V

BRAKE 24 V DC

123

# 1# 2

# 3 # 1

# 2

AC

-

+

AC

DownUp

AdjustableLimit Switch

# 1Contactor

Coils # 2

TransformerSec. 24V

HoistMotor

575 Volts

Green Ground 7

456

BlackWhiteRedBlue

OrangeWhite black stripe

Blue # 4Orange # 5

FUSE

FUSE

Page 15: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

VULCAN ELECTRIC TROLLEY WITH THERMAL OVERLOADTO CONNECT WITH VULCAN ELECTRIC HOIST

460 Volts 3 phase 60 Hz24 Volt Controls

See Diagram # T227

INDEX# 1 Left Contactor# 2 Right Contactor# 3 Thermal Overload# 4 Terminal Block# 5 Main Line Contactor

Revised April, 2010

#T227A

Green Ground

TrolleyMotor

460 Volts

# 1 # 2 # 3N.O. N.C.

Line # 1Line # 2Line # 3

# 1 # 2

ContactorCoils

# 1 # 2 # 3

Left Right

# 7# 6 # 4

CONNECT CABLE FROM HOIST NUMBER TO NUMBER

# 5

# 1 # 2 # 3 # 4 # 5

Push Button

Stop

Right

Left

Down

Up

Main LineContactor Coil

Pri. 460V

Sec. 24V

Transformer

#5

#4#7

#5#8

#6#9

FUSE

FUSE

Page 16: SCHÉMAS ÉLECTRIQUES WIRING DIAGRAMS - Vulcan Hoist · VULCAN ELECTRIC HOIST 2 SPEEDS 575 Volts 3 phase 60 Hz 24 Volt Controls Revised May, 2010 # V109 3 2 1 Green Ground 4 AC +

VULCAN ELECTRIC TROLLEY WITH THERMAL OVERLOADTO CONNECT WITH VULCAN ELECTRIC HOIST

575 Volts 3 phase 60 Hz24 Volt Controls

See Diagram # V127

INDEX# 1 Left Contactor# 2 Right Contactor# 3 Thermal Overload# 4 Terminal Block# 5 Main Line Contactor

Revised May, 2010

#V127A

Green Ground

TrolleyMotor

575 Volts

# 1 # 2 # 3N.O. N.C.

Line # 1Line # 2Line # 3

# 1 # 2

ContactorCoils

# 1 # 2 # 3

Left Right

# 7# 6 # 4

CONNECT CABLE FROM HOIST NUMBER TO NUMBER

# 5

# 1 # 2 # 3 # 4 # 5

Push Button

Stop

Right

Left

Down

Up

Main LineContactor Coil

Pri. 575V

Sec. 24V

Transformer

#5

FUSE

FUSE