savo 15 dg collector · 2018-10-02 · european commission’s directive 2014/68/eu. savosolar is...

2
Savo 15 DG collector Key features Direct flow MPE absorber with optimal heat transfer Highly effective, selective PVD MEMO absorber coating applied to the complete absorber (patent pen- ding) High transmittance tempered glass Etched antireflective treatment of the glass, which does not degrade over time Double glazing which minimises heat losses from convection • Integrated connection hoses, minimi- sing heat losses and shadowing Self-supporting frame structure for loads up to 2500 Pa • PED module A2 certification accor- ding to the directive 2014/68/EU of the European commission The Savo 15 DG collector is characte- rised by a direct flow aluminium ab- sorber, which is manufactured from MPE profiles. This technology is adopted from the automotive industry, where it has do- minated heat exchanger designs the past 30 years, and has now been op- timised for solar heating by Savosolar. The absorber is coated with a highly selective PVD MEMO coating (patent pending) and the use of MPE profiles minimises the average distance bet- ween the coated surface and the heat transfer fluid. This leads to a uniform temperature distribution where conductive heat losses are minimised. Just as modern cars and aircraft are assembled with glue, Savosolar as- sembles its collectors by gluing the galvanised steel frames, molded cor- ner pieces and anti-reflective solar glass together. In combination with a protective membrane in the venting elements, this minimises condensation or dust contamination. The Savo 15 DG collector is tested and Solar Keymark certified according to ISO 9806:2013 by SPF in Switzer- land. Savo 15 DG collector Savosolar collector with Direct Flow MPE absorber

Upload: others

Post on 03-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Savo 15 DG collector · 2018-10-02 · European commission’s directive 2014/68/EU. Savosolar is the only producer of collectors for district heating and industrial applications

Savo 15 DG collector

Key features

• Direct flow MPE absorber withoptimal heat transfer

• Highly effective, selective PVDMEMO absorber coating applied tothe complete absorber (patent pen-

ding)

• High transmittance tempered glass

• Etched antireflective treatment ofthe glass, which does not degradeover time

• Double glazing which minimisesheat losses from convection

• Integrated connection hoses, minimi- sing heat losses and shadowing

• Self-supporting frame structure forloads up to 2500 Pa

• PED module A2 certification accor- ding to the directive 2014/68/EU of the European commission

The Savo 15 DG collector is characte-rised by a direct flow aluminium ab-sorber, which is manufactured fromMPE profiles.This technology is adopted from theautomotive industry, where it has do-minated heat exchanger designs thepast 30 years, and has now been op-timised for solar heating by Savosolar.

The absorber is coated with a highlyselective PVD MEMO coating (patentpending) and the use of MPE profilesminimises the average distance bet-ween the coated surface and the heattransfer fluid. This leads to a uniform temperaturedistribution where conductive heatlosses are minimised.

Just as modern cars and aircraft areassembled with glue, Savosolar as-sembles its collectors by gluing thegalvanised steel frames, molded cor-ner pieces and anti-reflective solarglass together. In combination with a protectivemembrane in the venting elements,this minimises condensation or dustcontamination.

The Savo 15 DG collector is testedand Solar Keymark certified accordingto ISO 9806:2013 by SPF in Switzer-land.

Savo 15 DG collectorSavosolar collector with Direct Flow MPE absorber

Page 2: Savo 15 DG collector · 2018-10-02 · European commission’s directive 2014/68/EU. Savosolar is the only producer of collectors for district heating and industrial applications

Product number SF500-15DG

External Dimensions 6158 x 2591 x 157 mm

Gross area 15,96 m2

Aperture area 14,83 m2

Efficiency acc. to Solar Keymark* n0 = 0.853 a1 = 2.71 a2 = 0.0046

Incident angle modifier K50 = 0.97

Stagnation temperature 250 oC

Absorber coating 3 layer highly selective MEMO

Coating absorption 96 +/- 2%

Coating emissivity 5 +/- 2%

Max. operating pressure 1000 kPa (10 bar)

Thermal insulation 80/35 mm mineral wool + double glass

GlassTempered solar safetyantireflective glass

Solar glass transmittance 95%

Liquid content 28,0 liters

Weight empty 590 kg

CE marking Yes

Savosolar Oyj | Insinöörinkatu 7 | 50150 Mikkeli | Finland

Tel. +358 1027 10810 | [email protected] |www.savosolar.com

Integrated connectionsSavosolar’s large area collector for district heating andindustrial installations has integrated connectionhoses within the collector which allows mountingwith no more than 40 mm distance between collector(patent pending).

This technology reduces heat loss since the connec-tion hoses are protected by the collector’s insulation.

Technical data Pressure drop

*Related to aperture area

QualitySavosolar has been ISO 9001 certified since 2013 and has also received PED module A2 certification for the production of its large area collectors according to the European commission’s directive 2014/68/EU. Savosolar is the only producer of collectors for district heating and industrial applications with PED module A2 certification.

Technical specifications and optical appearance may vary without prior notice due to constant product improvement.

Savo

15

DG te

chni

cal d

atas

heet

201

8-09

-21

EN