sanitary layout legends water supply layout …

13
WATER SUPPLY LAYOUT SYMBOLS TEE 45 DEG ELBOW UNION WC LAV SHO WATER CLOSET LAVATORY SHOWER FD FLOOR DRAIN PU PD RISER (PIPE UP) RISER (PIPE DOWN) RISER (PIPE UP & DOWN) WATER SERVICE ENTRANCE 25 mm Ø PPR CWL PIPE 20 mm Ø PPR CWL PIPE 90 DEG ELBOW M GV CV WATER METER GATE VALVE CHECK VALVE HB HOSE BIBB 32 mm Ø PPR CWL PIPE SANITARY LAYOUT LEGENDS WYE SANITARY TEE 45 DEG ELBOW 90 DEG ELBOW 90 DEG ELBOW co WC LAV SHO WATER CLOSET LAVATORY SHOWER FD FLOOR DRAIN PU PD STACK (PIPE UP) STACK (PIPE DOWN) STACK (PIPE UP & DOWN) 75 mm Ø uPVC WASTE PIPE 50 mm Ø uPVC WASTE PIPE 75 mm Ø uPVC VENT PIPE 50 mm Ø uPVC VENT PIPE P - TRAP 75 mm Ø uPVC STORM DRAIN PIPE WS WASTE PIPE STACK VS VENT PIPE STACK DP DOWNSPOUT CB CATCH BASIN 63 mm Ø PPR CWL PIPE END CAP 20 mm Ø PPR HWL PIPE E. INDIRECT WASTE 1. NO EVAPORATIVE COOLER, OR SIMILAR AIR CONDITIONING EQUIPMENT SHALL HAVE ANY DRAIN PIPE IN CONNECTION THEREWITH, DIRECTLY CONNECTED TO ANY SOIL, WASTE AND VENT PIPE SUCH EQUIPMENT SHALL BE DRAINED BY MEANS OF INDIRECT WASTE PIPES AND ALL WASTES DRAINED BY THEM SHALL DISCHARGE THROUGH AN AIRBREAK INTO AN OPEN FLOOR SINK OR OTHER APPROVED TYPE RECEPTOR PROPERLY CONNECTED TO THE DRAINAGE SYSTEM. F. VENT PIPES 1. EACH PLUMBING FIXTURE TRAP, EXCEPT AS OTHERWISE PROVIDED IN THIS CODE, SHALL BE PROTECTED AGAINST SIPHONAGE AND BACK-PRESSURE, AIR CIRCULATION SHALL BE ASSURED THROUGHOUT ALL PARTS OF THE EXCRETA DRAINAGE SYSTEM BY MEANS OF VENT PIPES. 2. ALL VENT PIPES SHALL EXTEND UNDIMINISHED IN SIZE ABOVE THE ROOF SHALL BE RECONNECTED WITH THE SOIL OR WASTE STACK VENT OF PROPER SIZE AT A POINT BELOW THE ROOF, THE VENT THROUGH THE ROOF (VSTR) SHALL INCREASE ONE (1) PIPE SIZE ABOVE. G. STORM DRAINAGE 1. STORM DRAINAGE SHALL BE PROVIDED FOR ROOF AREAS, COURTS AND COURTYARDS TO COLLECT STORM WATER AND DISCHARGE THE STORMWATER TO AN APPROVED POINT OF DISPOSAL NOT IN CONFLICT WITH OTHER ORDINANCES OR REGULATIONS. H. HANGERS AND SUPPORT 1. PIPES SHALL BE SUPPORTED AT SUFFICIENTLY CLOSE INTERVALS TO KEEP THEM IN ALIGNMENT AND PREVENT SAGGING. MATERIAL SPECIFICATIONS COLD WATERLINE SHALL BE POLYPROPYLENE RANDOM CO-POLYMER TYPE 3 SEWERLINE/ SHALL BE UNPLASTICIZED POLYVINYL CHLORIDE (UPVC SERIES) VENT PIPES/ DOWNSPOUTS/ STORM DRAINAGE LABORATORY/ SHALL BE HIGH DENSITY POLYETHYLENE (HDPE PB16) PLUMBING GENERAL NOTES ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE PROVISION OF THE NATIONAL PLUMBING CODE OF THE PHILIPPINES AND THE LOCAL RULES AND REGULATION A. VERTICAL PIPING 1. PLASTIC PIPE - SHALL BE SUPPORTED AT EVERY - (1) METER INTERVAL B. HORIZONTAL PIPING 1. PLASTIC PIPE - SHALL BE SUPPORTED BY STIFF METAL BACKING HANGERS IN ITS ENTIRE LENGTH FOR SMALL SIZE TUBING UP TO 38mm DIAMETER AND WITHOUT BACKINGS BUT WITH SPACED METAL HANGERS AT APPROVED FOR LARGER-SIZE TUBING. C. PLUMBING FIXTURES 1. PLUMBING FIXTURE SHALL BE MANUFACTURED OF DENSE, DURABLE, NON-BORBENT MATERIALS AND HAVE SMOOTH, IMPERVIOUS SURFACES, FREE FROM UNNECESSARY CONCEALED FOULING SURFACES, EXCEPT AS PERMITTED ELSEWHERE IN THIS CODE, ALL FIXTURE SHALL CONFORM IN QUALITY AND NATIONAL RECOGNIZED APPLICABLE STANDARDS. WATER SUPPLY 1. EACH PLUMBING FIXTURE SHALL BE APPROVED WITH AN ADEQUATE SUPPLY OF POTABLE RUNNING WATER, SO ARRANGED AS TO FLUSH AND KEEP SAME IN CLEAN AND HEALTHFUL CONDITIONS WITHOUT DANGER OF BACKFLOW OR CROSS-CONNECTION. D. SEWERLINE 1. DRAINAGE PIPING SHALL BE PROVIDED WITH APPROVED INLET FITTINGS FOR FIXTURE CONNECTIONS, CORRECTLY LOCATED ACCORDING TO THE SIZE AND TYPE OF FIXTURE PROPOSED TO BE CONNECTED. 2. CHANGE IN DIRECTION OF DRAINAGE PIPING SHALL BE MADE BY THE APPROPRIATE USE OF APPROVED FITTINGS AND SHALL BE OF THE ANGLES PRESENTED BY A 22 1 2 DEGREES OR 1 18 BEND, 45 DEGREES OR 1 8 BEND AND 60 DEGREES OR 1 6 BEND OR OTHER APPROVED FITTINGS. SCALE 1 1 P NTS PLUMBING NOTES SCALE 1 2 P NTS PLUMBING LEGENDS P1 SHEET NO. APPROVED Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are the intellectual property and documents of the architect, whether the object for which they are made is executed or not. It shall be unlawful for any person to duplicate or make copies of said documents for use in the repetition of and for other projects or buildings, whether executed partly or in whole, without the written consent of the architect or author of said documents. RA 9266 SECTION 33 Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are the intellectual property and documents of the architect, whether the object for which they are made is executed or not. It shall be unlawful for any person to duplicate or make copies of said documents for use in the repetition of and for other projects or buildings, whether executed partly or in whole, without the written consent of the architect or author of said documents. RA 9266 SECTION 33 CONCURRED RECOMMENDING APPROVAL PROJECT TITLE LOCATION AS SHOWN PROPOSED RENOVATION OF BGHMC THREE-STOREY BUILDING FOR ISOLATION ROOMS BGHMC Compound, Baguio City Cordillera Administrative Region SHEET CONTENTS CHECKED RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESE Medical Center Chief II Baguio General Hospital & Medical Center RAY P. SUANDING, MD, FPCP, FPCCP Chief of Medical Professional Staff Baguio General Hospital & Medical Center VILMA O. MOLTIO, MPA Supervising Administrative Officer OIC,Chief Administrative Officer, HOPSS-BGHMC RICHIE RHEY R. DIRIGE, CE Engineer IV, Head EFMO - HOPSS Baguio General Hospital & Medical Center LENON S. BANA-E, CE, SE SANITARY ENGINEER BAGUIO GENERAL HOSPITAL AND MEDICAL CENTER REPUBLIC OF THE PHILIPPINES DEPARTMENT OF HEALTH BAGUIO CITY CORDILLERA ADMINISTRATIVE REGION 100 mm Ø uPVC WASTE PIPE 150 mm Ø uPVC WASTE PIPE

Upload: others

Post on 17-Mar-2022

15 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

WATER SUPPLY LAYOUT SYMBOLSTEE

45 DEG ELBOW

UNION

WCLAVSHO

WATER CLOSET

LAVATORY

SHOWER

FDFLOOR DRAIN

PU

PD

RISER (PIPE UP)

RISER (PIPE DOWN)

RISER (PIPE UP & DOWN)

WATER SERVICE ENTRANCE

25 mm Ø PPR CWL PIPE

20 mm Ø PPR CWL PIPE

90 DEG ELBOW

MGV

CV

WATER METER

GATE VALVE

CHECK VALVE

HB HOSE BIBB

32 mm Ø PPR CWL PIPE

SANITARY LAYOUT LEGENDSWYE

SANITARY TEE

45 DEG ELBOW

90 DEG ELBOW

90 DEG ELBOWco

WCLAVSHO

WATER CLOSET

LAVATORY

SHOWER

FDFLOOR DRAIN

PU

PD

STACK (PIPE UP)

STACK (PIPE DOWN)

STACK (PIPE UP & DOWN)

75 mm Ø uPVC WASTE PIPE

50 mm Ø uPVC WASTE PIPE

75 mm Ø uPVC VENT PIPE

50 mm Ø uPVC VENT PIPE

P - TRAP

75 mm Ø uPVC STORM DRAIN PIPE

WS WASTE PIPE STACK

VS VENT PIPE STACK

DP DOWNSPOUT

CB CATCH BASIN

63 mm Ø PPR CWL PIPE

END CAP

20 mm Ø PPR HWL PIPE

E. INDIRECT WASTE

1. NO EVAPORATIVE COOLER, OR SIMILAR AIR CONDITIONING EQUIPMENT SHALL HAVE ANYDRAIN PIPE IN CONNECTION THEREWITH, DIRECTLY CONNECTED TO ANY SOIL, WASTE ANDVENT PIPE SUCH EQUIPMENT SHALL BE DRAINED BY MEANS OF INDIRECT WASTE PIPESAND ALL WASTES DRAINED BY THEM SHALL DISCHARGE THROUGH AN AIRBREAK INTO ANOPEN FLOOR SINK OR OTHER APPROVED TYPE RECEPTOR PROPERLY CONNECTED TO THEDRAINAGE SYSTEM.

F. VENT PIPES

1. EACH PLUMBING FIXTURE TRAP, EXCEPT AS OTHERWISE PROVIDED IN THIS CODE, SHALLBE PROTECTED AGAINST SIPHONAGE AND BACK-PRESSURE, AIR CIRCULATION SHALL BEASSURED THROUGHOUT ALL PARTS OF THE EXCRETA DRAINAGE SYSTEM BY MEANS OFVENT PIPES.

2. ALL VENT PIPES SHALL EXTEND UNDIMINISHED IN SIZE ABOVE THE ROOF SHALL BERECONNECTED WITH THE SOIL OR WASTE STACK VENT OF PROPER SIZE AT A POINTBELOW THE ROOF, THE VENT THROUGH THE ROOF (VSTR) SHALL INCREASE ONE (1) PIPESIZE ABOVE.

G. STORM DRAINAGE

1. STORM DRAINAGE SHALL BE PROVIDED FOR ROOF AREAS, COURTS AND COURTYARDS TOCOLLECT STORM WATER AND DISCHARGE THE STORMWATER TO AN APPROVED POINT OFDISPOSAL NOT IN CONFLICT WITH OTHER ORDINANCES OR REGULATIONS.

H. HANGERS AND SUPPORT

1. PIPES SHALL BE SUPPORTED AT SUFFICIENTLY CLOSE INTERVALS TO KEEP THEM INALIGNMENT AND PREVENT SAGGING.

MATERIAL SPECIFICATIONSCOLD WATERLINE SHALL BE POLYPROPYLENE RANDOM CO-POLYMER TYPE 3

SEWERLINE/ SHALL BE UNPLASTICIZED POLYVINYL CHLORIDE (UPVC SERIES)VENT PIPES/DOWNSPOUTS/STORM DRAINAGE

LABORATORY/ SHALL BE HIGH DENSITY POLYETHYLENE (HDPE PB16)

PLUMBING GENERAL NOTESALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TOTHE PROVISION OF THE NATIONAL PLUMBING CODE OF THE PHILIPPINES ANDTHE LOCAL RULES AND REGULATION

A. VERTICAL PIPING1. PLASTIC PIPE - SHALL BE SUPPORTED AT EVERY - (1) METER INTERVAL

B. HORIZONTAL PIPING1. PLASTIC PIPE - SHALL BE SUPPORTED BY STIFF METAL BACKING

HANGERS IN ITS ENTIRE LENGTH FOR SMALL SIZE TUBING UP TO 38mmDIAMETER AND WITHOUT BACKINGS BUT WITH SPACED METAL HANGERSAT APPROVED FOR LARGER-SIZE TUBING.

C. PLUMBING FIXTURES1. PLUMBING FIXTURE SHALL BE MANUFACTURED OF DENSE, DURABLE,

NON-BORBENT MATERIALS AND HAVE SMOOTH, IMPERVIOUS SURFACES,FREE FROM UNNECESSARY CONCEALED FOULING SURFACES, EXCEPT ASPERMITTED ELSEWHERE IN THIS CODE, ALL FIXTURE SHALL CONFORM INQUALITY AND NATIONAL RECOGNIZED APPLICABLE STANDARDS.

WATER SUPPLY

1. EACH PLUMBING FIXTURE SHALL BE APPROVED WITH AN ADEQUATESUPPLY OF POTABLE RUNNING WATER, SO ARRANGED AS TO FLUSH ANDKEEP SAME IN CLEAN AND HEALTHFUL CONDITIONS WITHOUT DANGER OFBACKFLOW OR CROSS-CONNECTION.

D. SEWERLINE

1. DRAINAGE PIPING SHALL BE PROVIDED WITH APPROVED INLET FITTINGSFOR FIXTURE CONNECTIONS, CORRECTLY LOCATED ACCORDING TO THESIZE AND TYPE OF FIXTURE PROPOSED TO BE CONNECTED.

2. CHANGE IN DIRECTION OF DRAINAGE PIPING SHALL BE MADE BY THEAPPROPRIATE USE OF APPROVED FITTINGS AND SHALL BE OF THEANGLES PRESENTED BY A 22 1

2 DEGREES OR 118 BEND, 45 DEGREES OR 1

8BEND AND 60 DEGREES OR 16 BEND OR OTHER APPROVED FITTINGS.

SCALE1

1P NTS

PLUMBING NOTESSCALE1

2P NTS

PLUMBING LEGENDS

P1

SHEET NO.APPROVED Drawings and specifications andother contract documents duly signed,stamped or sealed, as instruments ofservice, are the intellectual propertyand documents of the architect,whether the object for which they aremade is executed or not. It shall beunlawful for any person to duplicateor make copies of said documents foruse in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said documents.

RA 9266 SECTION 33

Drawings and specifications andother contract documents duly signed,stamped or sealed, as instruments ofservice, are the intellectual propertyand documents of the architect,whether the object for which they aremade is executed or not. It shall beunlawful for any person to duplicateor make copies of said documents foruse in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said documents.

RA 9266 SECTION 33 CONCURREDRECOMMENDING APPROVALPROJECT TITLE

LOCATION AS SHOWN

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTS CHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LENON S. BANA-E, CE, SE

SANITARY ENGINEER

BAGUIO GENERAL HOSPITAL

AND MEDICAL CENTER

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

100 mm Ø uPVC WASTE PIPE

150 mm Ø uPVC WASTE PIPE

AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231
Page 2: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

SCALE2

1P 1:1,000 MTRS

SITE DEVELOPMENT PLANPARTIAL INDICATIVE BGHMC MASTER

10

17

OLD PS

A

C E F

6B

2

22

ST

GATE

H

J

G

1

23

24

VU

WATER TANK

1819

R

I

SHED

WATER TANK

P

Q3

BENECO POST

BENECO POST

W

AT

ER

TA

NK

OLD

BU

ILD

ING

25

13

14

27

STAIRS

K

L

STORE

26

W

MAIN ENTRANCE

MAIN EXIT

B G H M C D R I V E W A Y

TO BRGY. PHIL-AM

NORTHF L Y - O V E R

0 10 20 30 40 50 60 70 80 90 100m

0 10 000 50 000 100 000mm

PROJECT:PROPOSED RENOVATION OF

THREE-STOREY BUILDING FORISOLATION ROOMS

P2

SHEET NO.APPROVED Drawings and specifications andother contract documents duly signed,stamped or sealed, as instruments ofservice, are the intellectual propertyand documents of the architect,whether the object for which they aremade is executed or not. It shall beunlawful for any person to duplicateor make copies of said documents foruse in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said documents.

RA 9266 SECTION 33

Drawings and specifications andother contract documents duly signed,stamped or sealed, as instruments ofservice, are the intellectual propertyand documents of the architect,whether the object for which they aremade is executed or not. It shall beunlawful for any person to duplicateor make copies of said documents foruse in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said documents.

RA 9266 SECTION 33 CONCURREDRECOMMENDING APPROVALPROJECT TITLE

LOCATION AS SHOWN

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTS CHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LENON S. BANA-E, CE, SE

SANITARY ENGINEER

BAGUIO GENERAL HOSPITAL

AND MEDICAL CENTER

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

AutoCAD SHX Text
21
AutoCAD SHX Text
CUT- OFF
AutoCAD SHX Text
MILITARY
AutoCAD SHX Text
M
AutoCAD SHX Text
A
AutoCAD SHX Text
R
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
O
AutoCAD SHX Text
H
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
W
AutoCAD SHX Text
A
AutoCAD SHX Text
Y
AutoCAD SHX Text
K
AutoCAD SHX Text
E
AutoCAD SHX Text
O
AutoCAD SHX Text
N
AutoCAD SHX Text
N
AutoCAD SHX Text
R
AutoCAD SHX Text
O
AutoCAD SHX Text
A
AutoCAD SHX Text
D
AutoCAD SHX Text
LEGEND: 1. MAIN BUILDING (TWO STOREY) MAIN BUILDING (TWO STOREY) 2. FLAVIER BUILDING (6-STOREY) FLAVIER BUILDING (6-STOREY) 3. PAY WARD BUILDING (3-STOREY) PAY WARD BUILDING (3-STOREY) 4. OLD E.R. (2-STOREY) FOR DEMOLITION OLD E.R. (2-STOREY) FOR DEMOLITION 5. REPRODUCTIVE HEALTH REPRODUCTIVE HEALTH 6. INFECTIOUS DISEASE BUILDING INFECTIOUS DISEASE BUILDING 7. PSYCHIATRIC BUILDING PSYCHIATRIC BUILDING 8. UNDER 5 BUILDING (FOR DEMOLITION) UNDER 5 BUILDING (FOR DEMOLITION) 9. TB DOTS BUILDING FOR DEMOLITION) TB DOTS BUILDING FOR DEMOLITION) 10. CANCER CENTER BUILDING CANCER CENTER BUILDING 11. OUT PATIENT DEPARTMENT BUILDING OUT PATIENT DEPARTMENT BUILDING 12. ADMINISTRATION BUILDING (FOR DEMOLITION) ADMINISTRATION BUILDING (FOR DEMOLITION) 13. DOH-CAR BUILDING DOH-CAR BUILDING 14. DOH TRAINING CENTER DOH TRAINING CENTER 15. BGHMC DORMITORY BGHMC DORMITORY 16. OLD RESIDENTIAL BUILDING (FOR DEMOLITION) OLD RESIDENTIAL BUILDING (FOR DEMOLITION) 17. SECRETARY'S COTTAGE SECRETARY'S COTTAGE 18. GUEST HOUSE GUEST HOUSE 19. MEDICAL CENTER CHIEF COTTAGE MEDICAL CENTER CHIEF COTTAGE 20. RESCUE 911 (FOR DEMOLITION) RESCUE 911 (FOR DEMOLITION) (FOR DEMOLITION) 21. BGHMC COTTAGE BGHMC COTTAGE 22. MAINTENANCE & MOTORPOOL MAINTENANCE & MOTORPOOL 23. DOCTOR'S QUARTERS DOCTOR'S QUARTERS 24. TEMPORARY STORAGE BUILDING TEMPORARY STORAGE BUILDING 25. LAUNDRY BUILDING LAUNDRY BUILDING 26. DOH-CAR BUILDING (2-STOREY) DOH-CAR BUILDING (2-STOREY) 27. DOH-CAR MOTORPOOL & ADMIN BUILDING DOH-CAR MOTORPOOL & ADMIN BUILDING 28. BGHMC LIBRARY BUILDING (FOR DEMOLITION)BGHMC LIBRARY BUILDING (FOR DEMOLITION)
AutoCAD SHX Text
. A. RESIDENTIAL RESIDENTIAL B. RESIDENTIAL RESIDENTIAL C. CONCRETE WATER TANK CONCRETE WATER TANK D. WATER TREATMENT PLANT WATER TREATMENT PLANT E. PHARMACY BUILDING PHARMACY BUILDING F. LIQUID OXYGEN LIQUID OXYGEN G. CISTERN TANK CISTERN TANK H. CISTERN TANK CISTERN TANK I. WAITING SHED WAITING SHED J. FOOD COURT FOOD COURT K. CANTEEN CANTEEN L. GARRAGE GARRAGE M. GARBAGE BIN GARBAGE BIN N. WATER TANK WATER TANK O. WATER TANK WATER TANK P. BAGUIO WATER DISTRICT TANK BAGUIO WATER DISTRICT TANK Q. GARBAGE BIN GARBAGE BIN R. BODEGA / STORAGE BODEGA / STORAGE S. WASTE TANK WASTE TANK T. POWER HOUSE POWER HOUSE U. WATER TANK WATER TANK V. WATER TANK WATER TANK W. GENERATOR HOUSE GENERATOR HOUSE X. EXISTING BASKETBALL COURTEXISTING BASKETBALL COURT
AutoCAD SHX Text
PROPOSED COVERED CONNECTING LINK BRIDGE
AutoCAD SHX Text
PROPOSED RENAL CENTER
AutoCAD SHX Text
PROPOSED RENAL CENTER (ON-GOING)
AutoCAD SHX Text
PROPOSED MULTI-SPECIALTY CENTER (ON-GOING)
AutoCAD SHX Text
PARKING BUILDING
AutoCAD SHX Text
PROPOSED PSYCHIATRY COMPLEX (ON-GOING)
AutoCAD SHX Text
ODTRU
AutoCAD SHX Text
PROPOSED NEW LABORATORY BUILDING W/ NEW MOLECULAR LAB
AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231
Page 3: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

WS

WS

WSWS

WS

WS

WSWS

WS

WS

WSWS

WSWS WS

WS

WSWS

WS

WS

WS

WS

WC

WC

WC

WC

WC

WC

WC

WC

WC

WCWC

LAV

LAV

LAV

LAV

LAV

LAV LAV

LAV

LAV

SHO

SHO

SHO

SHO

SHO

SHO

SHO

SHO

EEW

EEW

SCALE3

1P 1:100 MTS

GROUND FLOOR WATERLINE LAYOUT

P3 SHEET NO.

APPROVED Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

CONCURREDRECOMMENDING APPROVAL

PROJECT TITLE

LOCATIONAS SHOW

N

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTSCHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LE

NO

N S

. B

AN

A-E

, C

E, S

E

SANITARY ENGINEER

BA

GU

IO

G

EN

ER

AL

H

OS

PIT

AL

AN

D M

ED

IC

AL

C

EN

TE

R

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

A B C E F G H J

1

2

3

4

5

6

7

8

9

D

1'

G'

10

11

12

13

14

AIRLOCK

Up

Ramp

Up

HALLWAY

HALL

WAY

Up

ACCESSGOING FROMDELTA E.R.

EMERGENCYEXIT

PERS

ONNE

L ACC

ESS

ENTRANCE

BEDELEVATOR

Dn

EXIT

Dn

250mm STRUCTURAL GAP

EXISTING INFECTIOUSDESEASE BUILDING

(PROPOSED DELTA E.R.)

Ramp Up

HOSPITAL ROAD

NORTH

Ramp Dn

200m

m ST

RUCT

URAL

GAP

2 938

1 412

1 725

22 750

2 200 6753 6254 2004 0003 0001 300 2503 500

41 80

0

3 750

3 750

3 750

3 750

1 850

2 950

6 075

200

4 800

1 275

350

3 050

3 275

3 325

2 700

1 500

1 775

2 100

2 475

1 500

41 80

0

200

2 575 1 725 6751 7501 875 7002 5001 0001 3002 700

15 00

0

3 750

3 750

3 750

3 750

1 850

1 500

6 075

1 825

1 500

6 075

26 80

0

2 950

3 050

3 275

1 825

1 500

4 575

2 2004 3004 2004 0004 300 2503 500

22 750

32 MM DIA CWL RISER (GF SUPPLY)

AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231
Page 4: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

WS

WS

WSWS

WS

WS

WSWS

WSWS

WSWS WS

WS

WSWS

WS

WS

WS

WS

WC

WC

WC

WC

WC

WC

WC

WC

WC

WCWC

LAV

LAV

LAV

LAV

LAV

LAV LAV

LAV

LAV

SHO

SHO

SHO

SHO

SHO

SHO

SHO

SHO

EEW

EEW

SCALE3a

1P 1:100 MTS

SECOND FLOOR WATERLINE LAYOUT

P3a

SHEET NO.APPROVED

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

CONCURREDRECOMMENDING APPROVAL

PROJECT TITLE

LOCATIONAS SHOW

N

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTSCHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LE

NO

N S

. B

AN

A-E

, C

E, S

E

SANITARY ENGINEER

BA

GU

IO

G

EN

ER

AL

H

OS

PIT

AL

AN

D M

ED

IC

AL

C

EN

TE

R

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

HALLWAY

HALL

WAY

Up

BEDELEVATOR

Up Dn

Dn

ROOF

ROOF

250mm STRUCTURAL GAP

NORTH

A B C E F G H J

1

2

3

4

5

6

7

8

9

D

1'

G'

10

11

12

13

14

EXISTING INFECTIOUSDESEASE BUILDING

(PROPOSED DELTA E.R.)

200m

m ST

RUCT

URAL

GAP

22 750

2 200 6753 6254 2004 0003 0001 300 2503 500

41 80

0

3 750

3 750

3 750

3 750

1 850

2 950

6 075

200

4 800

1 275

350

3 050

3 275

3 325

2 700

1 500

1 775

2 100

2 475

1 500

41 80

0

200

2 575 1 725 6751 7501 875 7002 5001 0001 3002 700

15 00

0

3 750

3 750

3 750

3 750

1 850

1 500

6 075

1 825

1 500

6 075

26 80

0

2 950

3 050

3 275

1 825

1 500

4 575

2 2004 3004 2004 0004 300 2503 500

22 750

WS WS

32 MM DIA CWL RISER (2F SUPPLY)

32 MM DIA CWL RISER (GF SUPPLY)

AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231
AutoCAD SHX Text
FW
AutoCAD SHX Text
5
Page 5: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

WS

WS

WSWS

WS

WS

WSWS

WSWS

WSWS WS

WS

WSWS

WS

WS

WS

WS

WC

WC

WC

WC

WC

WC

WC

WC

WC

WCWC

LAV

LAV

LAV

LAV

LAV

LAV LAV

LAV

LAV

SHO

SHO

SHO

SHO

SHO

SHO

SHO

SHO

EEW

EEW

SCALE3b

1P 1:100 MTS

THIRD FLOOR WATERLINE LAYOUT

P3b

SHEET NO.APPROVED

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

CONCURREDRECOMMENDING APPROVAL

PROJECT TITLE

LOCATIONAS SHOW

N

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTSCHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LE

NO

N S

. B

AN

A-E

, C

E, S

E

SANITARY ENGINEER

BA

GU

IO

G

EN

ER

AL

H

OS

PIT

AL

AN

D M

ED

IC

AL

C

EN

TE

R

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

HALLWAY

HALL

WAY

Up

BEDELEVATOR

Up Dn

Dn

ROOF

ROOF

250mm STRUCTURAL GAP

NORTH

A B C E F G H J

1

2

3

4

5

6

7

8

9

D

1'

G'

10

11

12

13

14

EXISTING INFECTIOUSDESEASE BUILDING

(PROPOSED DELTA E.R.)

200m

m ST

RUCT

URAL

GAP

22 750

2 200 6753 6254 2004 0003 0001 300 2503 500

41 80

0

3 750

3 750

3 750

3 750

1 850

2 950

6 075

200

4 800

1 275

350

3 050

3 275

3 325

2 700

1 500

1 775

2 100

2 475

1 500

41 80

0

200

2 575 1 725 6751 7501 875 7002 5001 0001 3002 700

15 00

0

3 750

3 750

3 750

3 750

1 850

1 500

6 075

1 825

1 500

6 075

26 80

0

2 950

3 050

3 275

1 825

1 500

4 575

2 2004 3004 2004 0004 300 2503 500

22 750

WS WS

32 MM DIA CWL RISER (2F SUPPLY)

32 MM DIA CWL RISER (GF SUPPLY)

32 MM DIA CWL RISER (3F SUPPLY)

AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231
AutoCAD SHX Text
FW
AutoCAD SHX Text
5
Page 6: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

PG PS

PRESSURETANK

GV CV

GV CV

GV CV

GV CVGV CV

FV

FV

GV

GV

GV

HB

WATERTANK 1

WATERTANK 2

P

SCALE3c

1P 1:100 MTS

ROOF WATERLINE LAYOUT

P3c

SHEET NO.APPROVED

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

CONCURREDRECOMMENDING APPROVAL

PROJECT TITLE

LOCATIONAS SHOW

N

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTSCHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LE

NO

N S

. B

AN

A-E

, C

E, S

E

SANITARY ENGINEER

BA

GU

IO

G

EN

ER

AL

H

OS

PIT

AL

AN

D M

ED

IC

AL

C

EN

TE

R

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

ROOFING

250mm STRUCTURAL GAP

NORTH

A B C E F G H J

1

2

3

4

5

6

7

8

9

D

1'

G'

10

11

12

13

14

22 750

3 500 250 4 300 4 000 4 200 4 300 2 200

4 575

1 500

1 825

3 275

3 050

2 950

26 80

0

6 075

1 500

1 825

6 075

1 500

1 850

3 750

3 750

3 750

3 750

15 00

0

2 700 1 300 1 000 2 500 700 1 875 1 750 6751 7252 575

200

41 80

0

1 500

2 475

2 100

2 700

3 325

3 275

3 050

350

1 275

4 800

200

6 075

2 950

1 850

3 750

3 750

3 750

3 750

41 80

0

3 500 250 1 300 3 000 4 000 4 200 3 625 675 2 200

22 750

EXISTING INFECTIOUSDESEASE BUILDING

(PROPOSED DELTA E.R.)

200m

m ST

RUCT

URAL

GAP

TAP TO EXISTING HOSPITAL WATER SUPPLY

32 MM DIA CWL RISER (2F SUPPLY)

32 MM DIA CWL RISER (GF SUPPLY)

32 MM DIA CWL RISER (3F SUPPLY)

AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231
Page 7: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

SEPTICTANK

CO CO

CO

CO

CO

CO

CO

CO CO

COCOCO

COCO

COCO

CO

CO

WCWC

WC

WC

WC

WC

WC

WC WC

WC

LAV

LAV

LAV

LAV

LAV

CO CO CO CO

COCO

CO

CO

COCO

CO

CO

CO

CO

FD

FD

FD

FD

FD

FDFD

FD

FD

FD

FD

CO

WS

WS

WS

WS

WS

WS WS

WS

WS

WS

LAV

LAV

LAVWS

WS

WS

WS

WS

WS

WS

WS

LAV LAVWS WS

FDFD

FDFD

FD

FD

FD

WS WS

WS

CO

COCOCO

CO

CO

TOSTP

FD

FD

FD

FD

FD

FD

FD

FD

100 MM DIA WASTE STACK

100 MM DIA WASTE STACK75 MM DIA VENT STACK

100 MM DIA WASTE STACK75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK100 MM DIA WASTE STACK

75mmØ DP

75mmØ DP 75mmØ DP 75mmØ DP75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

SCALE4

1P 1:100 MTS

GROUND FLOOR SEWER LINE LAYOUT

P4 SHEET NO.

APPROVED Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

CONCURREDRECOMMENDING APPROVAL

PROJECT TITLE

LOCATIONAS SHOW

N

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTSCHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LE

NO

N S

. B

AN

A-E

, C

E, S

E

SANITARY ENGINEER

BA

GU

IO

G

EN

ER

AL

H

OS

PIT

AL

AN

D M

ED

IC

AL

C

EN

TE

R

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

A B C E F G H J

1

2

3

4

5

6

7

8

9

D

1'

G'

10

11

12

13

14

AIRLOCK

Up

Ramp

Up

HALLWAY

HALL

WAY

Up

ACCESSGOING FROMDELTA E.R.

EMERGENCYEXIT

PERS

ONNE

L ACC

ESS

ENTRANCE

BEDELEVATOR

Dn

EXIT

Dn

250mm STRUCTURAL GAP

EXISTING INFECTIOUSDESEASE BUILDING

(PROPOSED DELTA E.R.)

Ramp Up

HOSPITAL ROAD

NORTH

Ramp Dn

200m

m ST

RUCT

URAL

GAP

2 938

1 412

1 725

22 750

2 200 6753 6254 2004 0003 0001 300 2503 500

41 80

0

3 750

3 750

3 750

3 750

1 850

2 950

6 075

200

4 800

1 275

350

3 050

3 275

3 325

2 700

1 500

1 775

2 100

2 475

1 500

41 80

0

200

2 575 1 725 6751 7501 875 7002 5001 0001 3002 700

15 00

0

3 750

3 750

3 750

3 750

1 850

1 500

6 075

1 825

1 500

6 075

26 80

0

2 950

3 050

3 275

1 825

1 500

4 575

2 2004 3004 2004 0004 300 2503 500

22 750

AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231
Page 8: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

FD

FD

COWC

WC

LAV

LAV

FD

FD

FD

WS

WS

WS

LAV

CO

CO

CO

CO

CO

COCO

CO

CO

COCO

COCO

COCO

CO

CO

CO

CO

CO

COCO

COCO

WS

WS

WS

WSWS

WS

WSWS

WS WS WS

WSWS

WS

WS

WS

WS

WS

LAV

LAV

LAV

LAV LAV

FDFD

FD

FD

FD

FD

FDFD

FD

FD

FD

FD

FD

FD WC

WC

WC

WCWC

WC

WC

WC

WC

LAV

COCO

FD

LAV

FD

100 MM DIA WASTE STACK

100 MM DIA WASTE STACK

100 MM DIA WASTE STACK75 MM DIA VENT STACK

100 MM DIA WASTE STACK75 MM DIA VENT STACK

100 MM DIA WASTE STACK75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK75 MM DIA VENT STACK

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP 75mmØ DP 75mmØ DP 75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75 MM DIA VENT STACK100 MM DIA WASTE STACK

SCALE4a

1P 1:100 MTS

SECOND FLOOR SEWER LINE LAYOUT

P4a

SHEET NO.APPROVED

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

CONCURREDRECOMMENDING APPROVAL

PROJECT TITLE

LOCATIONAS SHOW

N

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTSCHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LE

NO

N S

. B

AN

A-E

, C

E, S

E

SANITARY ENGINEER

BA

GU

IO

G

EN

ER

AL

H

OS

PIT

AL

AN

D M

ED

IC

AL

C

EN

TE

R

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

HALLWAY

HALL

WAY

Up

BEDELEVATOR

Up Dn

Dn

ROOF

ROOF

250mm STRUCTURAL GAP

NORTH

A B C E F G H J

1

2

3

4

5

6

7

8

9

D

1'

G'

10

11

12

13

14

EXISTING INFECTIOUSDESEASE BUILDING

(PROPOSED DELTA E.R.)

200m

m ST

RUCT

URAL

GAP

22 750

2 200 6753 6254 2004 0003 0001 300 2503 500

41 80

0

3 750

3 750

3 750

3 750

1 850

2 950

6 075

200

4 800

1 275

350

3 050

3 275

3 325

2 700

1 500

1 775

2 100

2 475

1 500

41 80

0

200

2 575 1 725 6751 7501 875 7002 5001 0001 3002 700

15 00

0

3 750

3 750

3 750

3 750

1 850

1 500

6 075

1 825

1 500

6 075

26 80

0

2 950

3 050

3 275

1 825

1 500

4 575

2 2004 3004 2004 0004 300 2503 500

22 750

AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231
AutoCAD SHX Text
FW
AutoCAD SHX Text
5
Page 9: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

FD

FD

CO

COWC

WC

LAV

LAV

FD

FD

FD

WS

WS

WS

LAV

CO

CO

CO

CO

CO

COCO

CO

CO

COCO

COCO

COCO

CO

CO

CO

CO

CO

COCO

COCO

WS

WS

WS

WSWS

WS

WSWS

WS WS WS

WSWS

WS

WS

WS

WS

WS

LAV

LAV

LAV

LAV LAV

FDFD

FD

FD

FD

FD

FDFD

FD

FD

FD

FD

FD

FD WC

WC

WC

WCWC

WC

WC

WC

WC

LAV

COCO

FD

LAV

FD

100 MM DIA WASTE STACK

100 MM DIA WASTE STACK

100 MM DIA WASTE STACK75 MM DIA VENT STACK

100 MM DIA WASTE STACK75 MM DIA VENT STACK

100 MM DIA WASTE STACK75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK75 MM DIA VENT STACK

75mmØ DP

75mmØ DP 75mmØ DP 75mmØ DP 75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

SCALE4b

1P 1:100 MTS

THIRD FLOOR SEWER LINE LAYOUT

P4b

SHEET NO.APPROVED

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

CONCURREDRECOMMENDING APPROVAL

PROJECT TITLE

LOCATIONAS SHOW

N

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTSCHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LE

NO

N S

. B

AN

A-E

, C

E, S

E

SANITARY ENGINEER

BA

GU

IO

G

EN

ER

AL

H

OS

PIT

AL

AN

D M

ED

IC

AL

C

EN

TE

R

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

HALLWAY

HALL

WAY

Up

BEDELEVATOR

Up Dn

Dn

ROOF

ROOF

250mm STRUCTURAL GAP

NORTH

A B C E F G H J

1

2

3

4

5

6

7

8

9

D

1'

G'

10

11

12

13

14

EXISTING INFECTIOUSDESEASE BUILDING

(PROPOSED DELTA E.R.)

200m

m ST

RUCT

URAL

GAP

22 750

2 200 6753 6254 2004 0003 0001 300 2503 500

41 80

0

3 750

3 750

3 750

3 750

1 850

2 950

6 075

200

4 800

1 275

350

3 050

3 275

3 325

2 700

1 500

1 775

2 100

2 475

1 500

41 80

0

200

2 575 1 725 6751 7501 875 7002 5001 0001 3002 700

15 00

0

3 750

3 750

3 750

3 750

1 850

1 500

6 075

1 825

1 500

6 075

26 80

0

2 950

3 050

3 275

1 825

1 500

4 575

2 2004 3004 2004 0004 300 2503 500

22 750

AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231
AutoCAD SHX Text
FW
AutoCAD SHX Text
5
Page 10: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

75 MM DIA VENT STACK

75 MM DIA VTR

75 MM DIA VTR

75 MM DIA VTR75 MM DIA VTR

75mmØ DP

75mmØ DP75mmØ DP

75mmØ DP 75mmØ DP 75mmØ DP 75mmØ DP

75 MM DIA VTR

75mmØ DP 75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

SCALE4c

1P 1:100 MTS

ROOF SEWER LINE LAYOUT

P4c

SHEET NO.APPROVED

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

Drawings and specifications andother contract docum

ents duly signed,stam

ped or sealed, as instruments of

service, are the intellectual propertyand docum

ents of the architect,whether the object for which they arem

ade is executed or not. It shall beunlawful for any person to duplicateor m

ake copies of said documents for

use in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said docum

ents.

RA

9

26

6 S

EC

TIO

N 3

3

CONCURREDRECOMMENDING APPROVAL

PROJECT TITLE

LOCATIONAS SHOW

N

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTSCHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LE

NO

N S

. B

AN

A-E

, C

E, S

E

SANITARY ENGINEER

BA

GU

IO

G

EN

ER

AL

H

OS

PIT

AL

AN

D M

ED

IC

AL

C

EN

TE

R

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

ROOFING

250mm STRUCTURAL GAP

NORTH

A B C E F G H J

1

2

3

4

5

6

7

8

9

D

1'

G'

10

11

12

13

14

22 750

3 500 250 4 300 4 000 4 200 4 300 2 200

4 575

1 500

1 825

3 275

3 050

2 950

26 80

0

6 075

1 500

1 825

6 075

1 500

1 850

3 750

3 750

3 750

3 750

15 00

0

2 700 1 300 1 000 2 500 700 1 875 1 750 6751 7252 575

200

41 80

0

1 500

2 475

2 100

2 700

3 325

3 275

3 050

350

1 275

4 800

200

6 075

2 950

1 850

3 750

3 750

3 750

3 750

41 80

0

3 500 250 1 300 3 000 4 000 4 200 3 625 675 2 200

22 750

EXISTING INFECTIOUSDESEASE BUILDING

(PROPOSED DELTA E.R.)

200m

m ST

RUCT

URAL

GAP

AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231
Page 11: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

SHEET NO.APPROVED Drawings and specifications andother contract documents duly signed,stamped or sealed, as instruments ofservice, are the intellectual propertyand documents of the architect,whether the object for which they aremade is executed or not. It shall beunlawful for any person to duplicateor make copies of said documents foruse in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said documents.

RA 9266 SECTION 33

Drawings and specifications andother contract documents duly signed,stamped or sealed, as instruments ofservice, are the intellectual propertyand documents of the architect,whether the object for which they aremade is executed or not. It shall beunlawful for any person to duplicateor make copies of said documents foruse in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said documents.

RA 9266 SECTION 33 CONCURREDRECOMMENDING APPROVALPROJECT TITLE

LOCATION AS SHOWN

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTS CHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LENON S. BANA-E, CE, SE

SANITARY ENGINEER

BAGUIO GENERAL HOSPITAL

AND MEDICAL CENTER

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

WS

WS

WS

WS

WS

WS

WS

WS

WSWS

WS

WSWS

WS

WS

WSWS

WSWS

WS

WS

WS

WC

WC

WC

WC

WC

WC

WC

WC

WC

WC

WC

LAVLAV

LAV

LAV

LAV

LAV

LAV

LAV

LAV

SHO

SHO

SHO

SHOSHO

SHO

SHO

SHOEEW

EEW

AB

C

E

F

G

HJ

1

23

4

56

78

9

D

1'

G'

10

11

12

13

14

AIRLOCK

Up Ramp Up

HALLWAY

HALLWAY

Up

ACCESS

GOING FROM

DELTA E.R.

EMERGENCY

EXIT

PERSONNEL ACCESS

ENTRANCE

BEDELEVATOR

Dn

EXIT

Dn

250mm STRUCTURAL GAP

EXISTING INFECTIOUS

DESEASE BUILDING

(PROPOSED DELTA E.R.)

Ramp Up

HOSPITAL ROAD

NORTH

Ramp Dn

200mm STRUCTURAL GAP2 938

1 412

1 725

22 750

2 200

675

3 625

4 200

4 000

3 000

1 300

250

3 500

41 800

3 750

3 750

3 750

3 750

1 850

2 950

6 075

200

4 800

1 275 350

3 050

3 275

3 325

2 700

1 5001 775

2 100

2 475

1 500

41 800 200

2 575

1 725

675

1 750

1 875

700

2 500

1 000

1 300

2 700

15 000

3 750

3 750

3 750

3 750

1 850

1 500

6 075

1 8251 500

6 075

26 800

2 950

3 050

3 275

1 8251 500

4 575

2 200

4 300

4 200

4 000

4 300

250

3 500

22 750

WS

WS

WS

WS

WS

WS

WS

WS

WS

WSWS

WS

WS

WSWS

WSWS

WS

WS

WS

WC

WC

WC

WC

WC

WC

WC

WC

WC

WC

WC

LAVLAV

LAV

LAV

LAV

LAV

LAV

LAV

LAV

SHO

SHO

SHO

SHOSHO

SHO

SHO

SHOEEW

EEW

WS WS

WS

WS

WS

WS

WS

WS

WS

WS

WS

WSWS

WS

WS

WSWS

WSWS

WS

WS

WS

WC

WC

WC

WC

WC

WC

WC

WC

WC

WC

WC

LAVLAV

LAV

LAV

LAV

LAV

LAV

LAV

LAV

SHO

SHO

SHO

SHOSHO

SHO

SHO

SHOEEW

EEW

WS WS

PGPS

PRESSURE

TANK

GV CV GV CV

GV CVGV CVGV CV

FV

FVGV

GV

GV

HB

WATERTANK 1

WATERTANK 2

P

TAP TO EXISTING HOSPITAL WATER SUPPLY

32 MM DIA CWL RISER (2F SUPPLY)

32 MM DIA CWL RISER (GF SUPPLY)

32 MM DIA CWL RISER (3F SUPPLY)

SCALE5

1P 1:120 MTRS

WATERLINE ISOMETRY

P5

AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231
Page 12: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

SHEET NO.APPROVED Drawings and specifications andother contract documents duly signed,stamped or sealed, as instruments ofservice, are the intellectual propertyand documents of the architect,whether the object for which they aremade is executed or not. It shall beunlawful for any person to duplicateor make copies of said documents foruse in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said documents.

RA 9266 SECTION 33

Drawings and specifications andother contract documents duly signed,stamped or sealed, as instruments ofservice, are the intellectual propertyand documents of the architect,whether the object for which they aremade is executed or not. It shall beunlawful for any person to duplicateor make copies of said documents foruse in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said documents.

RA 9266 SECTION 33 CONCURREDRECOMMENDING APPROVALPROJECT TITLE

LOCATION AS SHOWN

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTS CHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LENON S. BANA-E, CE, SE

SANITARY ENGINEER

BAGUIO GENERAL HOSPITAL

AND MEDICAL CENTER

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

SEPTICTANK

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

COCO

COCOWC

WC

WC

WC

WC

WC

WC

WC

WC

WC

LAVLAV LAV

LAV

LAV

COCO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

FDFD

FD

FD

FD FDFD

FD

FD

FD

FD

COWS

WS

WS WS

WS

WSWS

WS

WS

WS

LAV

LAV

LAV

WS

WS

WS

WSWS

WSWS

WS

LAV

LAV

WS

WSFD

FD

FD

FD

FD

FD

FD

WS

WS

WS

COCO

COCO

CO

CO

TO STP

FD

FDFD

FD

FD

FD

FD

FD

100 MM DIA WASTE STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP 75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

AB

C

E

F

G

HJ

1

23

4

56

78

9

D

1'

G'

10

11

12

13

14

AIRLOCK

Up Ramp Up

HALLWAY

HALLWAY

Up

ACCESS

GOING FROM

DELTA E.R.

EMERGENCY

EXIT

PERSONNEL ACCESS

ENTRANCE

BEDELEVATOR

Dn

EXIT

Dn

250mm STRUCTURAL GAP

EXISTING INFECTIOUS

DESEASE BUILDING

(PROPOSED DELTA E.R.)

Ramp Up

HOSPITAL ROAD

NORTH

Ramp Dn

200mm STRUCTURAL GAP2 938

1 412

1 725

22 750

2 200

675

3 625

4 200

4 000

3 000

1 300

250

3 500

41 800

3 750

3 750

3 750

3 750

1 850

2 950

6 075

200

4 800

1 275 350

3 050

3 275

3 325

2 700

1 5001 775

2 100

2 475

1 500

41 800 200

2 575

1 725

675

1 750

1 875

700

2 500

1 000

1 300

2 700

15 000

3 750

3 750

3 750

3 750

1 850

1 500

6 075

1 8251 500

6 075

26 800

2 950

3 050

3 275

1 8251 500

4 575

2 200

4 300

4 200

4 000

4 300

250

3 500

22 750

FD

FD

CO

WC

WC

LAVLAV FD

FD

FD

WS

WS

WS

LAV

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

WS

WS

WSWS

WS

WS

WS

WSWS

WS

WS

WS

WS

WS

WSWS

WS

WS

LAV

LAV

LAV

LAV

LAVFD

FD

FD

FD

FD

FD

FDFD

FD

FD

FD

FD

FD

FD WC

WC

WC

WC

WC

WC

WC

WCWC

LAV

CO

CO

FD

LAV

FD

100 MM DIA WASTE STACK

100 MM DIA WASTE STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

75 MM DIA VENT STACK

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

FD

FD

CO

WC

WC

LAVLAV FD

FD

FD

WS

WS

WS

LAV

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

WS

WS

WSWS

WS

WS

WS

WSWS

WS

WS

WS

WS

WS

WSWS

WS

WS

LAV

LAV

LAV

LAV

LAVFD

FD

FD

FD

FD

FD

FDFD

FD

FD

FD

FD

FD

FD WC

WC

WC

WC

WC

WC

WC

WCWC

LAV

CO

CO

FD

LAV

FD

100 MM DIA WASTE STACK

100 MM DIA WASTE STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

75 MM DIA VENT STACK

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75 MM DIA VENT STACK

100 MM DIA WASTE STACK

75 MM DIA VENT STACK

75 MM DIA VTR

75 MM DIA VTR

75 MM DIA VTR

75 MM DIA VTR

75mmØ DP75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75 MM DIA VTR

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

75mmØ DP

SCALE5a

1P 1:120 MTRS

SEWER LINE ISOMETRY

P5a

AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231
Page 13: SANITARY LAYOUT LEGENDS WATER SUPPLY LAYOUT …

FFL

50mm DIA. PVC WASTE STACK

PPR WATER SUPPLY PIPE

2"DIA. P TRAP W/ CLEAN-OUT

ESCUTCHEON

20mm DIA. PPR AIR CHAMBER

20mm DIA. PPR END CAP

HORIZONTAL PVC PIPE

444m

m

535m

m

800m

m

STAINLESS STEEL (SUS304)

WALL ANGLE VALVE

20MM DIA. PPR PIPE AIR CHAMBER20MM DIA. PPR PIPE WATER SUPPLY

ESCUTCHEONSUS304 TWO-WAYANGLE VALVE

FFL

TOILET

LAVATORY

AIR CHAMBER

PIPE SIZE

OUTLET

INLET

DC

38.10mm

38.10mm

PIPE SIZE

ø60mm

ø75mm

101.60mm

127.00mm

FLOOR DRAIN DETAIL;

50.80mmø150mm 155.80mm

44mm 152.40mmø100mm

D

FLR. LEVELC

PIPE SIZE

D

450mm

300mm

ø20mm

ø20mm

PIPE SIZEAIR CHAMBER DETAIL

50mm DIA. PVC VENT STACK

450m

m400m

m

600m

m

4

5

0

m

m

100m

m

STAINLESS STEEL SINK

(SUS) 3MM THK

STAINLESS STEEL

GOOSENECK FAUCET

SHEET NO.APPROVED Drawings and specifications andother contract documents duly signed,stamped or sealed, as instruments ofservice, are the intellectual propertyand documents of the architect,whether the object for which they aremade is executed or not. It shall beunlawful for any person to duplicateor make copies of said documents foruse in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said documents.

RA 9266 SECTION 33

Drawings and specifications andother contract documents duly signed,stamped or sealed, as instruments ofservice, are the intellectual propertyand documents of the architect,whether the object for which they aremade is executed or not. It shall beunlawful for any person to duplicateor make copies of said documents foruse in the repetition of and for otherprojects or buildings, whetherexecuted partly or in whole, withoutthe written consent of the architect orauthor of said documents.

RA 9266 SECTION 33 CONCURREDRECOMMENDING APPROVALPROJECT TITLE

LOCATION AS SHOWN

PROPOSED RENOVATION OF BGHMCTHREE-STOREY BUILDING FOR

ISOLATION ROOMS

BGHMC Compound, Baguio CityCordillera Administrative Region

SHEET CONTENTS CHECKED

RICARDO B. RUNEZ JR. MD, FPCS, MHA, CESEMedical Center Chief II

Baguio General Hospital & Medical Center

RAY P. SUANDING, MD, FPCP, FPCCPChief of Medical Professional Staff

Baguio General Hospital & Medical Center

VILMA O. MOLTIO, MPASupervising Administrative Officer

OIC,Chief Administrative Officer, HOPSS-BGHMC

RICHIE RHEY R. DIRIGE, CEEngineer IV, Head EFMO - HOPSS

Baguio General Hospital & Medical Center

LENON S. BANA-E, CE, SE

SANITARY ENGINEER

BAGUIO GENERAL HOSPITAL

AND MEDICAL CENTER

REPUBLIC OF THE PHILIPPINESDEPARTMENT OF HEALTH

BAGUIO CITYCORDILLERA ADMINISTRATIVE REGION

P6

MAN HOLE

MAN HOLE

MAN HOLE

200 3000 200 1000 200

200

W =

3000

200

200

1400

200

1400

200

D =

1800

300

150

250

D +

450

1:25 METERS50mm THK. LEAN CONCRETE

WATER LEVEL

100mmINLET

c.o. c.o. c.o.

c.o.

c.o.

c.o.

150mmINLET

100mmINLET

DIGESTIVE CHAMBER

LEACHING CHAMBER 1

LEACHING CHAMBER 2

DIGESTIVE CHAMBER

WATER LEVEL

LEACHING CHAMBER

PLAN

SECTION

75mm INLET FROMNEUTRALIZATION TANK

100mmINLET

10mmØ DEF. BARS SPACED

@ 100mm O.C.B.W.

c.o.

c.o.

10mmØ DEF. BARS SPACED

@ 150mm O.C.B.W.

10mmØ DEF. BARS SPACED

@ 100mm O.C.B.W.

10mmØ HOR.DEF. BARS SPACED

EVERY 3 LAYERS

150mm THK. CHBWALL PLASTERED

@ BOTH SIDES

12mm Ø SPACED@ 300mm .O.C

100mmOUTLET

12mmØ VERT.DEF. BARS SPACED

@ 800mm O.C.

12mm Ø SPACED@ 300mm B.W.O.C

4-PCS 12mm ØCONT. BARS

SLOPE SLOPE

SCALE6

1P NTS

TYPICAL FIXTURE DETAILSSCALE6

3P NTS

FLOOR DRAIN &AIR CHAMBER DETAIL

SCALE6

4P NTS

SEPTIC TANK DETAILS

SCALE6

2P NTS

WASH SINK DETAIL

AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
101.60
AutoCAD SHX Text
VERIFY
AutoCAD SHX Text
CADD By : LSB
AutoCAD SHX Text
Checked By : RRRD
AutoCAD SHX Text
Date :
AutoCAD SHX Text
Date :
AutoCAD SHX Text
TIN : 709-792-740-000
AutoCAD SHX Text
Validity:
AutoCAD SHX Text
PTR No.:
AutoCAD SHX Text
Place : BAGUIO CITY
AutoCAD SHX Text
PRC REG. No.: 003231