sandeep bhat systems bioimaging lab, ucsb presentation for engr 103, nov 20, 2008
DESCRIPTION
Blind Source-Separation for Heart Wall and Erythrocyte Motion Estimation in the Beating Embryonic Heart. Sandeep Bhat Systems Bioimaging Lab, UCSB Presentation for ENGR 103, Nov 20, 2008 [email protected]. Agenda. Motivation Problem Setup Algorithm stages Results Conclusion. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Sandeep Bhat Systems Bioimaging Lab, UCSB Presentation for ENGR 103, Nov 20, 2008](https://reader035.vdocuments.mx/reader035/viewer/2022062807/568151a2550346895dbfd2d2/html5/thumbnails/1.jpg)
Blind Source-Separation for Heart Wall and Erythrocyte Motion Estimation in the Beating Embryonic Heart
Sandeep BhatSystems Bioimaging Lab, UCSBPresentation for ENGR 103, Nov 20, 2008
![Page 2: Sandeep Bhat Systems Bioimaging Lab, UCSB Presentation for ENGR 103, Nov 20, 2008](https://reader035.vdocuments.mx/reader035/viewer/2022062807/568151a2550346895dbfd2d2/html5/thumbnails/2.jpg)
2
Agenda
• Motivation• Problem Setup• Algorithm stages• Results• Conclusion
![Page 3: Sandeep Bhat Systems Bioimaging Lab, UCSB Presentation for ENGR 103, Nov 20, 2008](https://reader035.vdocuments.mx/reader035/viewer/2022062807/568151a2550346895dbfd2d2/html5/thumbnails/3.jpg)
3
Motivation
• Study of model organisms
– Embryonic development, toxicology, specific gene function.
– Zebrafish embryo is transparent
• Live imaging of embryos.
– Fluorescence microscopy (FM)
– Bright field microscopy (BFM)
• The algorithm aids BFM imaging of developing zebrafish heart.
![Page 4: Sandeep Bhat Systems Bioimaging Lab, UCSB Presentation for ENGR 103, Nov 20, 2008](https://reader035.vdocuments.mx/reader035/viewer/2022062807/568151a2550346895dbfd2d2/html5/thumbnails/4.jpg)
4
Problem Setup
• Input: BFM image sequence
– Spanning several cardiac cycles.
• Desired output: Two image sequences
– Spanning one period (cardiac cycle)
– One showing only the heart morphology
– The other with only the transient structures (Red Blood Cells)
![Page 5: Sandeep Bhat Systems Bioimaging Lab, UCSB Presentation for ENGR 103, Nov 20, 2008](https://reader035.vdocuments.mx/reader035/viewer/2022062807/568151a2550346895dbfd2d2/html5/thumbnails/5.jpg)
5
Algorithm Stages
• Three stages:
– Pre-processing
– Separation algorithm
– Post-processing
![Page 6: Sandeep Bhat Systems Bioimaging Lab, UCSB Presentation for ENGR 103, Nov 20, 2008](https://reader035.vdocuments.mx/reader035/viewer/2022062807/568151a2550346895dbfd2d2/html5/thumbnails/6.jpg)
6
Separation Algorithm
• Temporal alignment
• Heart-wall:
– “Periodic”
– Mean/Median filtering
• Red Blood Cells:
– Not periodic
– Subtraction/Variance
![Page 7: Sandeep Bhat Systems Bioimaging Lab, UCSB Presentation for ENGR 103, Nov 20, 2008](https://reader035.vdocuments.mx/reader035/viewer/2022062807/568151a2550346895dbfd2d2/html5/thumbnails/7.jpg)
7
• Flow analysis using FlowJ
Post-processing
![Page 8: Sandeep Bhat Systems Bioimaging Lab, UCSB Presentation for ENGR 103, Nov 20, 2008](https://reader035.vdocuments.mx/reader035/viewer/2022062807/568151a2550346895dbfd2d2/html5/thumbnails/8.jpg)
8
Results• frequency components. • Testing with synthetically generated data.• Testing with synthetically generated data.
• (a) Mean+Subtraction (b) Mean+Variance
• (c) Median+Subtraction (d) Median+Variance
![Page 9: Sandeep Bhat Systems Bioimaging Lab, UCSB Presentation for ENGR 103, Nov 20, 2008](https://reader035.vdocuments.mx/reader035/viewer/2022062807/568151a2550346895dbfd2d2/html5/thumbnails/9.jpg)
9
Results (contd.)• BFM images of zebrafish heart
![Page 10: Sandeep Bhat Systems Bioimaging Lab, UCSB Presentation for ENGR 103, Nov 20, 2008](https://reader035.vdocuments.mx/reader035/viewer/2022062807/568151a2550346895dbfd2d2/html5/thumbnails/10.jpg)
10
Conclusion