Sampling Issues for Optimization in Radiotherapy

Michael C. FerrisR. Einarsson

Z. JiangD. Shepard

Page 2: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Conformal Radiotherapy

• Enhanced conformation allows for greater dosages of radiation to reach the target volume (conformal shaping) while minimizing the dose delivery to surrounding normal tissues (conformal avoidance)

Page 3: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Beam’s eye view

• Beam’s eye view at a given angle is determined based upon the beam source that intersects the tumor

• The view is constructed using a multi-leaf collimator

Page 4: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Delivery Plan

plus some integrality constraints

Page 5: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Mixed Integer Approach

Page 6: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Dose/Volume Constraints

• e.g. (Langer) no more than 5% of region R can receive more than U Gy

Page 7: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Alternative approaches

• Conditional Variance at Risk (CVAR)• Convex form that approximates

DVH constraints• Can use piecewise linearization and

adaptive penalty parameters• Alternatively use standard LP• P/L approach used in this work

Page 8: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Wedges• A metallic wedge

filter can be attached in front of the collimator.

• It attenuates the intensity of radiation in a linear fashion from one side to other.

• Particularly useful for a curved patient surface

• 5 positions considered: Open, North, East, South, and West.

Page 9: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Mixed Integer Approach

Page 10: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Conformal Therapy• Conventional treatment• Beam’s eye view (collimator shaping)• Multiple angles (choose subset)• Wedges (modify intensity over field)• Non-coplanar beams (choose which planes)• Avoidance (upper bounds)• Homogeneity, conformality• Dose/volume constraints

Page 11: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Assumptions/Setting• Dose calculation via Monte Carlo• Objective is “truth”; we really do

want to minimize it• Limit discussion to beam angle

selection; ideas are perfectly generalizable

• Limit “planning tool” to 3DCRT via MIP because we are nearby Europe

Page 12: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard
Page 13: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Remarks

• CPLEX 9.0 used, tight tolerances• Branch/Bound/Cut code• LP relaxation solved using dual

simplex (small samples) and barrier method (large samples)

• Terma may add sparsity, CPLEX removes dense columns in factor

Page 14: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Problems

• Large computational times• Large variance in computing times

• 5000-12500 sec (for 60,000 voxel case)

• Ineffective restarts (what if trials?)• Large amounts of data

• Try sampling of voxels (carefully)

Page 15: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

1% 3% 5% 7% 9% 11% 13% 15% 17% 19% 21%

0

200

400

600

800

1000

1200

1400

1600

Pelvis example: solution times for various sample rates;

Pro

cess

or

tim

e, [

sec]

Sampling rate

Page 16: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

1% 3% 5% 7% 9% 11% 13% 15% 17% 19% 21%

1.5

1.6

1.7

1.8

1.9

2

2.1

2.2

Pelvis example: objective values for various sample rates;

Ful

l o

bje

ctiv

e v

alu

e

Rate

Page 17: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Naïve sampling fails• Normal tissue

• Many more voxels available• Streaking effects• Use 5x sample on 2nd largest structure

• Small structures• Minimum sample size

• Homogeneity/min/max on PTV• 2x sample on PTV, rind sampling

• Large gradients on OAR’s• 2x sample on OAR’s

• Need adaptive mechanism

Page 18: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard
Page 19: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard
Page 20: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard
Page 21: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Time/quality tradeoff• Not really satisfactory• Split up problem into two phases

• Find a reduced set of angles at coarse sampling

• Optimize with reduced set of angles with finer sample

• Reduced angle problem much faster

• But doesn’t identify angle set well…

Page 22: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard
Page 23: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Multiple samples

• Generate K instances at very coarse sampling rate

• Use histogram information to suggest promising angles

• How many? (e.g. K=10)• How to select promising angles?

(frequency > 20%)

Page 24: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Full Objective Value• >20% scheme may lose best solution• Can calculate the objective function

with complete sample cheaply from solution of sampled problem

• Use extra information in 2 ways:1. Select only those angles that appear in the

best “full value” solutions2. Refine samples in organs where

discrepancies are greatest

Page 25: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

0.6 1.2 2.4 3.6 4.8 7.2 9.6 14.4 30 600

0.02

0.04

0.06

0.08

0.1

0.12

0.14

0.16

0.18

0.2

Sample size (*1000)

Error in objective components

Err

or

totptvblarecnor

Page 26: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Phase I• Must be very fast to be useful• LP relaxation much quicker

(allowing larger sample rates) and time variance much smaller

• But too many angles suggested…

• Utilize summed weight information to rank angles over complete set

Page 27: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Drawbacks• Weight values not necessarily

correlated to “usefulness”• Sample objective is underestimator,

and provides little information

• Utilize this procedure to do “gross reduction”, followed by Phase II to refine angles further

Page 28: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Sampling Process

• Determine initial sample size• Phase I: use all angles

• 10 sample LP’s solutions determine

• Phase II: use reduced set of angles• 10 sample MIP’s determine

• Phase III: use further reduced set • Increase sample rate, solve single MIP

Page 29: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Initial sample size• Choose trial sample size K• Solve LPrelax(K)• Double K until Time(LPrelax(2*K))

unacceptable• If

unacceptable, ERROR(more time) • Value(K) is full sample objective

value from sample size K optimization

Page 30: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Phase III

• Phase II may make all decisions so problem could be an LP for example

• Sample at fine enough rate to

satisfy industry requirements• Clean up phase!

Page 31: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Pelvis case

• 3K prostate, 1.5K bladder, 1K rectum, 557K normal

• Time for “full problem”: 12.5K secs• Time Phase I: 16 secs• Time Phase II: 100 secs• Time Phase III: 10 secs• Solution: 40, 80, 150, 240, 270, 300

Page 32: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard
Page 33: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard
Page 34: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Pancreas case

• 6K pancreas, 515 cord, 9K ltt, 6K rtt, 54K liver, 502K normal

• Time for “full problem”: 1200 secs• Time Phase I: 2 secs• Time Phase II: 12 secs• Time Phase III: 80 secs• Solution: 80, 290, 350 (+ wedges)

Page 35: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard
Page 36: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Breast case

• 39K ptv, 13K heart, 11K rind breast, 71K normal

• Time Phase I: 18 secs• Time Phase II: 11 secs• Time Phase III: 2 secs• Solution: 130, 290 (+ wedges)

Page 37: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard
Page 38: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard
Page 39: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Head/Neck case

• 2K ptv, 51K l/rcerebrum, 2K brainstm, 14K cerebellum, others (15-833)

• Time for “full problem”: 2542K secs• Time Phase I: 10 secs• Time Phase II: 22 secs• Time Phase III: 2 secs• Solution: 30, 140, 230 (+ wedges)

Page 40: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard
Page 41: Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard

Extensions

• Within 3DCRT• Wedges, energy levels, non-coplanar

beams all optimized concurrently

• Tomotherapy• IMAT• IMRT• Larger and more complex cases