sampling and analysis of isocyanates used in paints robert p. streicher national institute for...

28
Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S. Government are within the public domain and therefore are not copyrighted.

Upload: elisabeth-webster

Post on 18-Jan-2016

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Sampling and Analysis of Isocyanates Used in Paints

Robert P. Streicher

National Institute for Occupational Safety and Health

Publications of the U.S. Government are within the public domain and therefore are not copyrighted.

Page 2: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Background

• Isocyanate compounds are major components of spray paints used in the aerospace industry

• Paints contain primarily polyisocyanates with low levels of isocyanate monomer

• Primarily aliphatic isocyanates

Page 3: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Commonly Used Aliphatic Isocyanate Monomers

NN

CO

CO

CH3NCH3

CH2

N C O

CO

H3C

HDI

IPDI

Page 4: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Polyisocyanate Species Found in Paints

CN

C

NC

N

N

N

N

OO

O

C O

CO C O

HDI Isocyanurate

Page 5: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Polyisocyanate Species Found in Paints (cont.)

CN

C

NH HN

N

N

N

OO

C O

CO C O

HDI Biuret

Page 6: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Polyisocyanate Species Found in Paints (cont.)

NC

NC

NN C OCO

O

O

HDI Uretidinedione Dimer

Page 7: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Complications in Total Isocyanate Determination

• Vapor and Aerosol

• Very reactive (unstable)

• Potentially numerous species for which no analytical standards are available

Page 8: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Six Steps in Sampling and Analytical Methods

• Collection

• Derivatization

• Sample Preparation

• Separation

• Identification

• Quantification

Page 9: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Collection Efficiency Problems

• Aspiration efficiency

• Internal losses

• Transmission losses

Page 10: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Collection• Particles

– Inhalable Sampler (e.g., IOM): all particles

– 37-mm filter: < 20 m– Impinger: 2 m < x < 20 m

• Vapor – may depend on derivatization

Page 11: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Overspray AerosolParticle Size

• Rudzinski (1995): 4.1 +/- 1.7 m 6.9 +/- 2.5 m

• Myer (1993): 10 - 15 m

• D’Arcy (1990): 2.9 - 9.7 m

Page 12: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Derivatization

• Capture (vapors on filters)

• Stabilization

• Detectability

Page 13: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Factors Affecting Derivatization Efficiency

• Inherent reagent reactivity

• Reagent concentration

• Reagent-isocyanate mixing

Page 14: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Impinger / Filter Comparisons• Most field comparisons have found

impingers to give higher results - Maitre (1996), Myer (1993), Czarnecki (1992)

• Rosenberg (1984) found filters to be higher

• Bello (2000) found IOM = impingers

Page 15: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Sampling Recommendations• Be flexible• Filter

– Used for:

- All particles < 2 m- Slow-cure particles > 2 m

– Extract filters in the field– High-boiling solvent on filters (?)

• Impingers– Used for fast-cure particles > 2 m

Page 16: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Sample Preparation• Extraction

• Sonication

• Filtration

• Solvent exchange

• Concentration

• Solid-phase extraction

Page 17: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Analytical Separation:

Reversed-Phase HPLC

Page 18: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Analytical Strategies

• Bulk product for calibration (Bayer)

• Monomer for calibration (MAP Method, MDHS 25/2, NIOSH 5522)

Page 19: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Bulk Product for Calibration

• Less demanding HPLC and detection

• Requires that isocyanate composition of calibrant matches composition of exposure

Page 20: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Monomer Calibration

• Demanding HPLC and detection requirements

• Does not require bulk product calibrant with composition matching exposure

• Bulk product used qualitatively

Page 21: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

HPLC:

Isocratic or Gradient Elution?

Page 22: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Advantages of Isocratic Elution

• Simple

• Compatible with EC detector

• Stable baseline

• Unvarying response factor

Page 23: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Advantages of Gradient Elution

• Powerful - wider range of compounds

• Faster

• Better peak shape

Page 24: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

HDI/IPDI Oligomer Bulk

Page 25: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Identification of Derivatized Isocyanates

• Monomers - Retention time

• Oligomers– Retention time– Two detectors - response ratio is

diagnostic– Multi-dimensional detector (mass

spectrometer, photodiode array)

Page 26: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Quantification

• Monomer and oligomer from monomer calibration curve

Page 27: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S

Conclusions

• Determination of isocyanates is complex

• Filter sampling of paints may be OK with short sampling times and field extraction

• Bulk product calibration or monomer calibration - choice depends on product variability, availability of product calibrants

Page 28: Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S